40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 95 of 344  Not logged in ELOG logo
ID Date Author Type Category Subjectup Text Attachments
  136   Wed Nov 28 19:44:18 2007 tobinUpdatePSLHEPAI found the HEPA turned off completely.  I
turned it on.
  
  6674   Thu May 24 13:28:38 2012 DenUpdatePEMHEPAHEPA filter was running at 90% of max.
I reduced it to 20%. Acoustic noise moved
down
 psl_acoustic.pngmcl_90.pngmcl_20.png 
  15568   Thu Sep 10 15:56:08 2020 KojiUpdateGeneralHEPA & Particle Level Status15:30
- PSL HEPA was running
at 33% and 
  
  15630   Thu Oct 15 20:00:23 2020 KojiSummaryGeneralHEPA AC cord replacementThe AC cord from the PSL HEPA variac
to the junction box was replaced.
Now the HEPA is running at 70%
 P_20201015_200732.jpgP_20201015_200752.jpgP_20201015_202615.jpgP_20201015_204234.jpg 
  15989   Thu Apr 1 23:55:33 2021 KojiSummaryGeneralHEPA AC cord replacementI think
the PSL HEPA (both 2 units) are not running.
The switches were on. And the variac was
  
  15992   Fri Apr 2 15:17:23 2021 gautamSummaryGeneralHEPA AC cord replacementFrom the last failure, I had ordered 2
extra capacitors (they are placed on top
of the PSL enclosure above where the capacitors
  
  15597   Tue Sep 22 23:16:54 2020 KojiUpdateGeneralHEPA InspectionGautam reported that the PSL HEPA stopped
running (ELOG
15592). So I came in today and started
 11x 
  15598   Tue Sep 22 23:17:51 2020 KojiUpdateGeneralHEPA InspectionDimensions / Specs

- HEPA unit dimentions
- HEPA unit manufacturer
 6x 
  17214   Tue Oct 25 22:24:46 2022 KojiUpdateIOOHEPA OFF / WFS OFFTurned HEPA OFF / Lab Lights OFF / WFS
Input Gain switched off for the IMC WFS signal
tests.
  
  17215   Wed Oct 26 10:28:05 2022 PacoUpdateIOOHEPA ON / WFS ONTurned HEPA ON this morning at 10:28 local
(pacific time) or gpstime
  
  5943   Fri Nov 18 08:29:35 2011 SureshUpdateIOOHEPA air-flow effect on WFS.[Koji, Suresh]
    We investigated
the effect of airflow from the HEPA filters
 WFS_err_HEPA.pngWFS_err_mc2t_effect.png 
  15604   Wed Sep 30 17:12:24 2020 gautamUpdateGeneralHEPA blower startup capacitor replacement[JV, GV]

The HEPAs work again. After running
  
  15605   Wed Sep 30 19:45:56 2020 ranaUpdateGeneralHEPA blower startup capacitor replacementit would be a good idea for us to have
an auto-reminder to have us check the flow
of all the HEPAs in the lab and elog it once
  
  12312   Tue Jul 19 15:30:08 2016 SteveUpdateGeneralHEPA dryer and dustI set up a simple HEPA filter dryer to
dry your clean room garment before 
you can put it away into your storage box.
 HEPAdryer.jpg 
  524   Fri Jun 6 16:10:51 2008 steveUpdatePSLHEPA filters are running at 100%The psl HEPA filters were turned up to run
at 100% to accommodate beam trap work on
Tuesday, June 3, 2008
  
  5931   Thu Nov 17 21:12:09 2011 KojiUpdatePSLHEPA setting changed[Koji, Suresh]
8:50PM HEPA@100% for the test
8:55PM HEPA@0%
  
  16082   Fri Apr 23 18:00:02 2021 gautamUpdatePSLHEPA speed loweredI will upload some plots later - but in
summary, I set the HEPA speed to ~40%. I
used (i)IMC transmission RIN, (ii) Arm cavity
 HEPAdiag.pdf 
  16083   Fri Apr 23 19:26:58 2021 KojiUpdatePSLHEPA speed loweredI believe that there is an internal setting
for the minimum flow, so the flow is not
linear ("0%" is not zero), but
  
  16141   Fri May 14 17:45:05 2021 ranaUpdatePSLHEPA speed raisedThe PSL was too hot, so I turned on the
south HEPA on the PSL. The north one was
on and the south one was off (or so slow
  
  16144   Tue May 18 00:52:38 2021 ranaUpdatePSLHEPA speed raisedLooks like the fan lowered the temperature
as expected. Need to get a few more days
of data to see if its stabilized, or if that's
 Untitled.png 
  16145   Tue May 18 20:26:11 2021 ranaUpdatePSLHEPA speed raisedFluke. Temp fluctuations
are as usual, but the overall temperature
is still lower. We ought to put some temperature
  
  5922   Thu Nov 17 11:27:58 2011 JenneUpdatePSLHEPA turned downI was measuring things to see how big my
adapter plate needs to be, and I decided
that we'd had enough days of the HEPA being
  
  646   Tue Jul 8 10:20:10 2008 steveUpdatePEMHEPA turned onIt is specially important to run the PSL-HEPA
filters when inside counts is peaking at
30,000 counts
 hepa.jpg 
  10429   Mon Aug 25 15:49:44 2014 SteveUpdatePSLHEPA turned onThe PSL HEPA was off. It was turned on
and it is running at 30VAC now.
  
  6000   Thu Nov 24 14:05:10 2011 KojiUpdatePSLHEPA@50%I left the HEPA at the 50% level @5AM,
Nov 24
  
  2165   Fri Oct 30 10:52:56 2009 JenneUpdatePSLHEPAsZach found the HEPA switch on the PSL table
OFF.  He turned them on.
  
  15592   Mon Sep 21 16:40:52 2020 gautamUpdatePSLHEPAs are no longer runningThe HEPA filters on the PSL enclosure are
no longer running. I tried cycling the power
switch on the NW corner of the enclosure,
  
  1848   Thu Aug 6 19:54:04 2009 StephanieUpdatePSLHEPAs back to normal


   
        
            
  
  15   Thu Oct 25 22:02:58 2007 robRoutinePSLHEPAs maxedIn light of the SoCal fires, I turned the
PSL HEPAs up to 100%.
  
  12461   Thu Sep 1 15:40:52 2016 SteveUpdateSUSHEPAs on each chamber doorThis is an option to isolate the vacuum
chamber from the dusty 40m lab: 4x8 HEPA
unit or
 chamberDoorHepaEA.pdf 
  1844   Thu Aug 6 17:45:37 2009 JenneUpdatePSLHEPAs on highStephanie has needed the doors to the PSL
open all day, and still has them open, so
I just turned the HEPAs on high. 
  
  690   Thu Jul 17 13:08:37 2008 JohnSummaryLSCHOM resonances in the armsOn Tuesday night we attempted to lock the
full DRFPMI in the optical spring configuration
with the +f2 sideband resonant in the SRC.
 HOMresonances.png 
  206   Thu Dec 20 19:05:34 2007 waldmanHowToOMCHOWTO build front endsFor instance,  to build the TPT front end
code.
  
  8352   Tue Mar 26 11:33:55 2013 JamieUpdateOpticsHOWTO calculate effective RoC of flipped TTIn case anyone is curious how I got the
numbers for the effective radius of curvature
of the flipped TT mirrors, I include the
 mirror.mtransmission.mTTflipped.mM2Reff.m 
  1104   Sun Nov 2 20:21:58 2008 ranaConfigurationloreHP 5550dtn (Grazia) set up on allegraI set up printing to grazia from allegra.
The CUPS interface was not as straightforward
as Tobin had made it seem in the Wiki. I
  
  1217   Thu Jan 8 16:49:37 2009 ranaConfigurationloreHP 5550dtn (Grazia) set up on allegra[quote]I set up printing to grazia from allegra.
The CUPS interface was not as straightforward
as Tobin had made it seem in the Wiki. I
  
  9837   Mon Apr 21 23:33:57 2014 ranaSummaryGreen LockingHP 8591E reads low by 140 Hz out of 10 MHzTo
check the basolute frequency stability of
the old monochrome HP 8591E RF Spectrum analyzer
  
  328   Thu Feb 21 18:29:28 2008 JohnSummaryGeneralHP Network Analyser AnalyzerThe HP 4195A network analyser may be broken,
measurements below 150MHz are not reliable.
Above 150MHz everything looks normal. This
  
  827   Tue Aug 12 12:05:36 2008 YoichiUpdateComputersHP color printer is backI restarted the HP printer server (a little
box connected to the HP color laser) so that
we can use the HP LaserJet 2550.
  
  3831   Sun Oct 31 00:19:35 2010 ranaSummaryComputer Scripts / ProgramsHP3563A netGPIB functionI've wheeled the old HP audio frequency
signal analyzer into the control room to
debug the GPIB/python interface. The wireless
  
  3792   Wed Oct 27 09:02:29 2010 steveUpdateElectronicsHP4195A is NOT fixedwww.avalontest.com has fixed the 25MHz
oscillation.  Contact: Jim Burnham 760-536-0191
  
  398   Mon Mar 24 13:03:54 2008 robUpdateElectronicsHP4195A is back

[quote]The swept sine output looks totally
  
  1445   Mon Mar 30 15:51:27 2009 steveUpdateElectronicsHP4291A left the lab to be repairedEric Gustafson is handling the old HP4291A
rehabilitation. Tarac picked both units up
today.
  
  10210   Wed Jul 16 01:27:01 2014 NichinHowToComputer Scripts / ProgramsHP8591E spectrum analyzer remote scanThe script for running continuous scans
on HP 8591E spectrum analyzer is located
at scripts/general/netgpibdata
 HP8591E_View.pdf 
  10217   Wed Jul 16 17:06:41 2014 NichinUpdateComputer Scripts / ProgramsHP8591E spectrum analyzer remote scanUpdated script does the following:
1) Gets the highest 2 peaks
2) Puts a marker on the peaks. Now
 HP8591E_View.pdf 
  10381   Wed Aug 13 23:58:49 2014 ranaHowToComputer Scripts / ProgramsHP8591E spectrum analyzer remote scan

    

       
            
 HP8591E_View.pdf 
  1324   Thu Feb 19 11:51:56 2009 steveUpdateMOPAHTEMP variation is too muchThe C1:PSL-MOPA_HTEMP variation is more
than 0.5 C daily
Normally this
temp stays well within 0.1 C
This
 80dhtemp.jpg 
  16033   Wed Apr 14 23:55:34 2021 gautamUpdateElectronicsHV Coil driver assemblyI've occcupied the southernmost electronics
bench for assembling the 4 production version
HV coil driver chassis. I estimate it will
  
  16140   Fri May 14 03:29:50 2021 KojiUpdateElectronicsHV Driver noise test with the new HV power supply from MatsusadaI believe I did the identical test with
the one in [40m
ELOG 15786]. The + input of PA95 was
 HV_Driver_PSD.pdf 
  15773   Wed Jan 20 10:13:06 2021 gautamUpdateElectronicsHV Power supply bypassingSummary:

Installing 10uF bypass capacitors
on the High
 bypassCaps.pdfIMG_9079.jpgIMG_9078.jpgHVampNoise_driven_chassis.pdfprintCoilCurrents.pdf 
ELOG V3.1.3-