  13872   Mon May 21 14:17:28 2018 KiraUpdatePEMtest setup with seismometerI have attached the graph for the seismometer
temperature fluctuations over 3 days. As
we can see, there is a noticeable fluctuation
 seis-temp.png 
  13877   Tue May 22 14:49:03 2018 KiraUpdatePEMtest setup with seismometerIt appears that one of the wires was disconnected
overnight or this morning so I wasn't
able to gather data over a full 24 hour period.
 seis-temp-2.png 
  13882   Wed May 23 14:50:33 2018 KiraUpdatePEMtest setup with seismometerThis time the test went without issue.
The first attachment is the data for the
past 24 hours and the second attachment is
 seis-temp-3.pngseis-temp-full-2.png 
  13887   Thu May 24 15:18:12 2018 KiraUpdatePEMPID loop restartedRana said that it wasn't necessary
to gather more data on the temperature fluctuations
so I have reconnected the heater circuit
  
  13888   Thu May 24 16:08:12 2018 KiraUpdatePEMparts listWe will need to order a few things for
our final setup.


1U box to place the heater
 front_panels.zip 
  13894   Tue May 29 16:22:43 2018 KiraUpdatePEMparts listI've updated the parts list to be an
excel document and included every single
part we will need. This is ony a first draft
 parts_list_-_Sheet1.pdf1U-panel-2.fpdEX-can-panel.fpd 
  13903   Thu May 31 15:48:16 2018 KiraUpdatePEMrunning PID script with seismometerI have attached the result of running the
PID script on the seismometer with the can
on. The daily fluctuations are no more than
 can-on-pid.png 
  13922   Wed Jun 6 15:12:29 2018 KiraUpdatePEMparts from labGot this 1U box from the Y arm that we
could potentially use (attachment 1). It
doesn't have handles on the front but
 IMG_20180606_141149.jpgIMG_20180606_141851.jpgIMG_20180606_141912.jpg 
  13979   Mon Jun 18 11:12:23 2018 KiraSummaryPEMfinishing up work at the labSince I am finishing my job at the lab,
I have stored all my electronics in a box
(attachment 1) and placed it under the table
 IMG_20180618_101640.jpgIMG_20180618_093920.jpgIMG_20180618_093932.jpg 
  1326   Thu Feb 19 22:40:33 2009 KiwamuUpdateElectronicsPSL angle QPDI checked a broken QPD, which was placed
for PSL angle monitor, and finally I cocluded
one segment of the quadrant diode was
  
  1363   Fri Mar 6 01:04:49 2009 Kiwamu IZUMIConfigurationIOO!! lock-in amp disconnected !!The power supply of a lock-in amp, which
is on the Y-arm side of PSL clean room, was
pulled out by my mistake.
  
  3540   Tue Sep 7 23:34:15 2010 Kiwamu, SanjitConfigurationComputerse-loge-log was repeatedly hanging and several
attempts to start the daemon failed.
problem was solved after clearing
  
  10682   Thu Nov 6 14:41:49 2014 KoijUpdateLSC3F RFPD RF spectraThat's not what I'm asking.
Also
additional cables are left connected to the
  
  556   Tue Jun 24 10:24:43 2008 KojiUpdateGeneralAbs. Len. Meas. ~ Cavity Swing Measurement (2)At the entry 555, Alberto reported the results
of the cavity length measurement using cavity
sweeping.
 armlength.pngarmlength2.png 
  561   Wed Jun 25 00:35:40 2008 KojiSummaryGeneralOptical Layout on the AP tableI have visited the AP table in order to investigate
where we are going to put the optical setup
for the abs. length meas. 
 optical_layout_ap_table.pngoptical_layout_ap_table.pdf 
  567   Wed Jun 25 13:38:22 2008 KojiUpdateGeneralAbs. Len. Meas. ~ Placement of the 700mW NPRO on the AP tableThis morning I have put the 700mW NPRO on
the AP table for the abs length measurement.
 NPRO700mW_placement.jpg 
  590   Sun Jun 29 02:33:28 2008 KojiUpdateGeneralAbs. Len. Meas. ~ Optical setup (I)I have constructed the beam injection optics
for the abs length measurement.
 optical_configuration.pngoptical_layout_ap_table2.pngoptical_layout_ap_table2.pdf 
  599   Mon Jun 30 05:33:38 2008 KojiUpdateGeneralAbs. Len. Meas. ~ Optical setup (II)o The position of the iris was adjusted so
as not to disturub the beam for OMCR CCD.
  
  619   Tue Jul 1 21:54:05 2008 KojiUpdateGeneralRe: Abs. Length Meas. setupI tried to look for the beating in the signal
from the PD but I couldn't find. I had the
temperature of the laser initially set to
  
  628   Thu Jul 3 11:53:30 2008 KojiUpdateGeneralStatus of the alignment of the NPRO beam for the Absolute Length MeasurementThe method itself looked fine.

Use of the one arm configuration will make
  
  635   Thu Jul 3 22:54:45 2008 KojiUpdateGeneralBeats of the two lasers in the absolute length measurement observed Great! Conguraturation! I wish if I could
see it! It's nice if you can put the photo
or anything of the RF spectrum analyzer.
  
  638   Mon Jul 7 13:06:38 2008 KojiUpdateGeneralBeats of the two lasers in the absolute length measurement observed One may need an RF filter after the mixer.
I expect the SR560 does work for this purpose.
If it does not, a passive LPF can be used.
  
  666   Mon Jul 14 10:57:00 2008 KojiFrogsEnvironmentSomeone at 40M sent LHO water of lifeSomeone at the 40m sent Mike@LHO a pound of
peets coffee with the name of Koji Arai.
It was a good surprise! Thanks, we will enjoy
  
  730   Thu Jul 24 01:27:00 2008 KojiUpdateLSCArm cavity g-factor measurement[quote]I locked the Y-arm and mis-aligned
the end mirror in Yaw until the transmission
power gets half.
  
  738   Fri Jul 25 10:48:13 2008 KojiUpdateGeneralAbs. Len. Meas. ~ Realignment / beating / PLL trialAlberto and Koji

o We worked for the abs length measurement
  
  748   Mon Jul 28 15:54:04 2008 KojiUpdateGeneralAbs. Len. Meas. ~ More on the beat / the PLL setupAlberto and Koji,

Last Friday evening, Koji found that the
 PLL_setup.pngbeat_at_8MHz.jpg 
  753   Tue Jul 29 09:12:43 2008 KojiConfigurationIOOMC length measurementI found that the prev modulation freq had
been determined with a same kind of measurement
by Osamu, which also looked accurate.
  
  759   Tue Jul 29 19:53:19 2008 KojiUpdateSUSPRM photos from the south windowSteve and Koji

We took some photos of PRM from the south
 PRM_from_South_Window1.jpgPRM_from_South_Window2.jpg 
  768   Wed Jul 30 13:14:03 2008 KojiSummaryIOOHistory of the MC abs lengthI was notified by Rob and Rana that there
were many measurements of the MC abs length
(i.e. modulation 
 MC_length.png 
  774   Thu Jul 31 10:24:32 2008 KojiUpdateGeneralIFO statusLast night I used the Y-arm for the abs length
measurement. The Yarm was aligned by the
script. 
  
  776   Thu Jul 31 11:19:30 2008 KojiUpdateGeneralAbs. Len. Meas. ~ Resonance search trialLast night, I tried to find the resonance
of Yarm by sweeping the frequency of the
injection beam.
  
  782   Sat Aug 2 12:53:43 2008 KojiUpdateGeneralAbs. Len. Meas. ~ New PLL at the PSL table[B]Report of the work last night:[/B]
The new heterodyne interferometer on the
PSL table was built.
 yarm_dc.png 
  783   Sat Aug 2 13:07:23 2008 KojiConfigurationGeneralThe AP table cleanedDuring the construction of the independent
PLL I cleaned up some of the unused optics
from the AP table. Essentially this should
  
  787   Mon Aug 4 00:37:58 2008 KojiUpdateGeneralAbs. Len. Meas. ~ RF PD at the Y end / Manual frequency scan[B]Work log on August 2nd[/B]

o Just remind you:
 YEND_LAYOUT.png4th_FSR1.png4th_FSR2.png 
  788   Mon Aug 4 00:56:07 2008 KojiHowToGeneralAbs. Len. Meas. ~ Auto freq scanner with GPIB[B]Work log on August 3rd  - Part1[/B]

o Yesterday I was too much tired of changing
 freq_scan.png 
  789   Mon Aug 4 05:23:57 2008 KojiUpdateGeneralAbs. Len. Meas. ~ Measurement for Y-arm completedFinally, I have completed the abs length and
g-factor measurements for Y-arm.
[COLOR=green][B]>>>GO FOR THE VENT<<<[/B][/COLOR]
  
  793   Mon Aug 4 21:48:24 2008 KojiUpdateGeneralAbs. Len. Meas. ~ Scan for TEM00/01/10[B]Work log on August 3rd  - Part2[/B]

o I tried to measure the frequency of the
 TEM00.pngTEM01.pngknife_edge.png 
  794   Mon Aug 4 22:31:10 2008 KojiUpdateGeneralAbs. Len. Meas. ~ Simple Test for TEM01/10 split[B]Work log on August 3rd - Part3[/B]

[B]Question:[/B]
 TEM01_10.png 
  795   Tue Aug 5 00:05:57 2008 KojiUpdateGeneralAbs. Len. Meas. ~ IFR2023A calibration[B]Work log on August 4th[/B]

o IFR2023A (Marconi) was calibrated by the
  
  796   Tue Aug 5 02:39:55 2008 KojiConfigurationGeneralAbs. Len. Meas. ~ Optical Layout on the AP / PSL table 2008-Aug-05Here are the PDF and the PNG of the AP and
PSL table layouts.
After this photo, the squeezing setup at
 optical_layout_ap_table3.pngoptical_layout_ap_table3.pdfoptical_layout_PSL_table1.pngoptical_layout_PSL_table1.pdf 
  801   Wed Aug 6 11:10:34 2008 KojiUpdateGeneralAbs. Len. Meas. ~ analysis of the TEM00 scan[B]Analysis of the data on August 3th ~ Part
1[/B]
 TEM00fit.pngTEM00FSRfit.png 
  802   Wed Aug 6 11:43:52 2008 KojiUpdateGeneralAbs. Len. Meas. ~ analysis of the TEM01 scan[B]Analysis of the data on August 3th ~ Part
2[/B]
 TEM01fit.png 
  838   Thu Aug 14 21:52:51 2008 KojiSummaryGeneralAbs. Len. Meas. ~ summary of my SummerI have made the summary of the absolute length
measurement.
It is attached here. The file is a bit big
 mode_spacing_measurement_080816_v2.pdf 
  1026   Sat Oct 4 07:23:42 2008 KojiMetaphysicsEnvironmentThe GatekeeperHi, this is Koji from Japan.

I am afraid that this is a poisonous spider,
  
  1717   Tue Jul 7 15:08:49 2009 KojiSummaryPhotos40 high school students visited 40MAlan and Alberto conducted a tour of 40
high-school students.
It may be the same tour that Rana
 IMG_1848.jpg 
  1753   Wed Jul 15 18:22:15 2009 KojiUpdateCamerasRe: GigE Phase Camera


   
        
            
  
  1789   Sat Jul 25 13:34:58 2009 KojiUpdateGeneralWeek 5/6 Update


   
        
            
  
  1790   Sat Jul 25 13:49:28 2009 KojiUpdateGeneralMultiply Resonant EOM Update


   
        
            
  
  1792   Sat Jul 25 19:04:01 2009 KojiUpdatePSLAligning the beam to the Faraday


   
        
            
 MC2_Cam.jpg 
  1799   Mon Jul 27 19:55:19 2009 KojiHowToIOOLens selection: plano-convex? or bi-convex?Q. When should we use plano-convex lenses,
and when should we use bi-convex?
As I had the same question from Jenne
  