40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 94 of 344  Not logged in ELOG logo
ID Dateup Author Type Category Subject Text Attachments
  4687   Wed May 11 11:24:59 2011 steveUpdateSUSSRM-oplev qpd is back

    

       
            
 srm-prm_oplevs.jpg 
  4688   Wed May 11 11:44:52 2011 kiwamuUpdateSUSf2p filters installed on ITMYNew f2p
filters were installed on 
 f2p_itmy.png 
  4689   Wed May 11 13:54:32 2011 steveUpdateLSCLSC power suppliesAux- rack _1Y2 is just behind 1Y3 
It contains Kepco Analoge DC power supplies
for +- 5, 15 and 24V
 P1070679.JPG 
  4690   Wed May 11 16:04:36 2011 Larisa ThorneConfigurationElectronicsJenne-Seismometer LPF projectThe schematic for the seismometer box from
this last
time  has been updated...
 STS2diagram2.png 
  4691   Wed May 11 17:10:04 2011 kiwamuConfigurationElectronicsfixed : MC3 LL PD has no signal[Valera / Kiwamu]
It was because of a loose connection.
Pushing the connector solved the issue.
 looseconnectionMC3.png 
  4692   Wed May 11 17:20:24 2011 kiwamuConfigurationIOOloop diabled on PZT2[Valera / Kiwamu]
 
  
  4693   Wed May 11 21:58:30 2011 ranaUpdateSUSETMX_OPLEV : He-Ne replaced

    
        
  
  4694   Wed May 11 22:52:55 2011 kiwamuUpdateLSCstatus update and planRana forced
me to write this entry for summary because
  
  4695   Wed May 11 22:54:53 2011 JenneUpdateTreasureETMY trans QPD installedI put the ETMY trans QPD in. 
The ETMY trans beam was already going
toward the TRY DC PD, and a CCD camera. 
  
  4696   Wed May 11 23:02:52 2011 valeraUpdateASSDither angular stabilizitaion system updateThis is what was done in past two days:
- The ETMY and ITMY pitch and yaw
dofs are modulated at 40, 44, 42, 46 Hz respectively
  
  4697   Thu May 12 00:59:45 2011 ryan, ranaUpdatePSLReturn of the PSL temperature boxThe PSL temperature box has returned to
service, with some circuit modifications.
The 1k resistors on all the temp. sensor
  
  4698   Thu May 12 02:31:07 2011 SureshUpdateRF Systeminstallation of RF splitters in Demod boards[Jamie, Koji, Suresh]
We replaced splitters in several
demod boards as per the table given below:
  
  4699   Thu May 12 05:25:26 2011 kiwamuUpdateIOOIP_POS disconnectedA
cable for IP_POS has been disconnected at
the LSC rack, 1Y2. Due to it currently no
  
  4700   Thu May 12 08:54:11 2011 steveUpdateIOOIP_POS cable found

    

       
            
  
  4701   Thu May 12 09:00:23 2011 steveUpdateGeneraloptical table covers must be usedI found ITMX-ISCT and BS-ISCT ( IFO sensing-control
table)  not covered this morning. Please
do not leave tables open.
  
  4702   Thu May 12 10:27:02 2011 ranaUpdateRF Systeminstallation of RF splitters in Demod boards

    

       
            
  
  4703   Thu May 12 16:50:22 2011 SureshUpdateRF Systeminstallation of RF splitters in Demod boardsWe have no plan to change the AS11 PD.
 I was referring to the AS11 Demod board
which currently has the "Demodulator
  
  4704   Thu May 12 18:21:19 2011 kiwamuUpdateIOOwelcome back IP_POSIP_POS
is back.  
  
  4705   Thu May 12 22:54:20 2011 ranaUpdateDAQInput Beam Naming change (no more IP) We decided to rename the Input Beam
channels (while keeping temporary backwards
compatible aliases) as:
  
  4706   Thu May 12 23:12:40 2011 kiwamuUpdateCDSc1lsc crashedThis
is my third time to crash a real-time machine.
This time I crashed c1lsc.
  
  4707   Thu May 12 23:41:47 2011 ranaUpdateCDSMEDM Snapshots not workingLooks like 2 different MEDM Snapshot
functiions (at least) are broken.
The regular update of the screens
  
  4708   Thu May 12 23:50:10 2011 SureshUpdateRF SystemPOY55_Demod board Hardware change completedThe Demod board with S. No. 022 (being
used earlier as REFL11) has been modified. 
It now has SCLF-65 as its input LP filter
  
  4709   Fri May 13 00:39:53 2011 valeraUpdateASSc1ass updateHere the status of the dither alignment
or c1ass:
- Both pitch and yaw centering on
 c1assqpds.jpg 
  4710   Fri May 13 01:42:35 2011 kiwamuUpdateLSCready for Schnupp asymmetry measurement[Valera / Kiwamu]
 We are able to lock each arm
  
  4711   Fri May 13 01:51:56 2011 SureshUpdateRF SystemRF Status updateI have posted the attached RF status update
and 1Y2 rack layout to the svn.
 1Y2_Rack_Layout.pdfRF_Work_Status.pdf 
  4712   Fri May 13 14:54:20 2011 Leo SingerUpdateComputersDiaggui fixed on pianosaI fixed diaggui on pianosa.  Previously,
it was not able to start because it depended
on libreadline5, whereas Ubuntu distributed
  
  4713   Fri May 13 17:20:48 2011 Leo SingerConfigurationSUSTuned bounce and roll mode of ETMY suspensionI tuned the bounce and roll mode bandstops
for ETMY, although it was difficult for me
to tell if there was improvement with the
  
  4714   Fri May 13 22:45:37 2011 SureshUpdateRF SystemThe full set of 8 Demod boards is ready for testingWe have Completed the hardware changes
to the full set of 8 demod boards. 
The last one completed today is AS11. 
  
  4715   Fri May 13 23:04:58 2011 SureshUpdateRF SystemDC power supply on RF distribution box has been replaced.[Steve, Koji, Suresh]
   We shifted two Sorensen
power supplies from the Auxiliary rack next
 P5130120.JPG 
  4716   Sat May 14 14:12:16 2011 KojiUpdateRF SystemDC power supply on RF distribution box has been replaced.Key
points of the power supply installation


    We
 sorensen.png 
  4717   Sat May 14 14:50:21 2011 KojiUpdateLSC1Y2 5V Blown Fuse found -> FixedIncidentally,
a blown fuse on 5V line at 1Y2 rack was found
during the intallation of Sorensens.
 1Y2_5V_Fuse.JPG 
  4718   Sun May 15 03:58:19 2011 ranaUpdateCDSdiagonalization of MC input matrixThere has been some input matrix diagonalization
in the past by
Yuta and Kiwamu, but I find the automation
 mc1.png 
  4719   Sun May 15 12:42:29 2011 kiwamuUpdateSUSf2p ratio adjutment done for all the suspensionsThe f2p adjustment
for all the suspensions are done
 f2p_summary.pdf 
  4720   Sun May 15 14:01:56 2011 kiwamuUpdateIOOwiring diagram for IP-POSHere is a wiring diagram which shows how
IP-POS (new official name is IB_POS)
is connected.
 ip_pos.png 
  4721   Sun May 15 19:10:12 2011 kiwamuUpdateLSCCalibration of actuators : BS, ITMX and ITMYThe AC
response of the actuators on BS, ITMX and
 oltf.pngcalib_actuators.png 
  4722   Sun May 15 19:55:15 2011 kiwamuUpdatePhotosETMY optical benchJust for a record. This is the latest picture
of the ETMY optical bench.
I will upload this picture on the
 ETMY_ss.jpg 
  4723   Sun May 15 21:27:51 2011 JenneUpdatePhotosETMY optical benchI didn't notice it the other day when I
was working on putting in the trans QPD,
but do we need to 
  
  4724   Mon May 16 10:05:02 2011 kiwamuUpdatePhotosRe:ETMY optical benchYou are right. We should change or rotate
the mirror mount.  
Actually when Suresh and I were putting
  
  4725   Mon May 16 11:14:36 2011 ranaUpdateIOOwiring diagram for IP-POSJust FYI, the 3113 is a 12-bit ADC, so
we won't get very good resolution out of
these. We should get one of those purple
  
  4726   Mon May 16 11:47:59 2011 kiwamuUpdateASSc1ass update part IIThe medm screen for c1ass started being
modified to be more user-friendly.
The modification is still 
 c1ass.png 
  4727   Mon May 16 15:46:05 2011 KojiUpdateGeneraloptical layout viewable on the online version of autocadI have made my own AutoCAD WS account and
put the latest 40m layout.
AutoCAD WS is a free cloud service
  
  4728   Mon May 16 17:11:28 2011 steveUpdateElectronicsstrain relieved 1X11X1 is strain relieved in the back. I will
use similar approach on the rest of the racks
.
 P1070724.JPG 
  4729   Tue May 17 01:05:56 2011 kiwamuUpdateLSCAsymmetry measurement prep : recentering worksI
re-centered beams on several PDs and a camera
including :
  
  4730   Tue May 17 11:45:20 2011 JamieConfigurationCDSpurged non-c1 site files from rtcds checkout of cds_user_appsI purged all of the working copy checkouts
of site files for all sites that are not
c1 from the rtcds cds_user_apps working directory
  
  4731   Tue May 17 16:53:22 2011 kiwamuUpdateSUSoplev sign was wrong on ETMYLast
night I found that the sign of the oplev
control of PITCH on ETMY was wrong.
  
  4732   Tue May 17 17:01:22 2011 jamieConfigurationCDSUpdate LSC channels from _DAQ to _DQAs of RCG version 2.1, recorded channels
use the suffix "_DQ", instead of
"_DAQ".  I just rebuilt and
  
  4733   Tue May 17 18:09:13 2011 Jamie, KiwamuConfigurationCDSc1sus and c1auxey crashed, rebootedc1sus and
c1auxey crashed, required hard reboot
  
  4734   Tue May 17 19:38:32 2011 kiwamuUpdateSUSwrong connection on 1X5Today Steve was working around the 1X5
rack to strain relief the cable jungles and
the
 wrong.pngcorrect.png 
  4735   Tue May 17 22:50:00 2011 JamieConfigurationLSCNew digital lockin added to LSC model/screenI added a lockin to the LSC model, and
added it's corresponding control to the LSC
screen.  Here's is what I added to the
 lsc-mdl-lockin.pnglsc-screen-lockin.pnglsc-lockin-screen.png 
  4736   Wed May 18 07:13:00 2011 SureshUpdateRF SystemDemod board measurementsI measured the amplitude and phase imbalances
of the demod boards which have been modified. 
This is just a basic health check. 
 Demod_Board_measurements.pngDemod_Board_measurements.png 
ELOG V3.1.3-