40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 93 of 344  Not logged in ELOG logo
ID Date Author Typeup Category Subject Text Attachments
  1675   Tue Jun 16 02:09:31 2009 robUpdateLockingDD handoff finally workingI had trouble getting the SRC handoff from
SD to DD to work.  I tried different
gains, flipping the PD7 & 8 demod phases
  
  1676   Tue Jun 16 03:43:04 2009 robUpdateLockingsame troublesLock is still being lost, right at the
end of the process when trying to reduce
the CARM offset to zero.
  
  1678   Tue Jun 16 14:02:16 2009 robUpdateLockinglockedThe IFO is locked, at the operating point
(zero CARM offset).  The problem with
reducing the residual CARM offset in the
  
  1679   Tue Jun 16 16:10:01 2009 peteUpdateLockinginput matrix experimentsLast night Rob ran senseDRM and loadDRMImatrixData
and came up with the following for the input
matrix:
  
  1680   Tue Jun 16 17:38:35 2009 robUpdateLockingDeWhites ONWith the common mode servo bandwidth above
30kHz and the BOOST on (1), I was able to
switch on the test mass dewhitening. 
  
  1681   Tue Jun 16 20:03:41 2009 AlbertoUpdateElectronicsRequirements on Wenzel MultiplierFor
the 40m Upgrade, we plan to 
 SummaryOfResult.pdf 
  1683   Wed Jun 17 01:09:47 2009 robUpdateComputers/cvs/cds 91% fullIn /cvs/cds/caltech
 
  
  1684   Thu Jun 18 23:08:46 2009 robUpdateLockingspectrumHere's a noise spectrum of the RSE interferometer,
in anti-spring mode, with RF readout. 
I'd say the calibration is "loose."
 DARMnoise_929352240.pngDARMnoise_929352240.pdf 
  1687   Fri Jun 19 13:39:29 2009 AidanUpdateGeneralUpper limit measurement of the scatter from the eLIGO beam dumps. 
 D0900095_ELIGO_35_WATT_AIR_COOLED_BEAM_DUMP_3INCH_P.POL-3.PDFbeam_dump_expt.pngscatter_measurement1.pdfBRDF1.pdfIMG_0308.JPG 
  1690   Tue Jun 23 10:06:03 2009 steveUpdateVACnew maglev RGA scan at day6The Maglev is running for 10 days with
V1 closed.  The pressure at the RGA-region
is  at 2e-9 torr on CC4 cold cathode
 newmagscand6.jpgnmagpresd10.jpg 
  1694   Wed Jun 24 10:53:34 2009 Chris ZimmermanUpdateGeneralWeek 1/2 UpdateI've spent most of the last week doing
background reading; fourier transforms, shm,
e&m, and other physics that I didn't
  
  1695   Wed Jun 24 11:20:40 2009 StephanieUpdateGeneralMultiply Resonant EOM UpdateI have created the attached EOM circuit
with resonances at 11 MHz, 29.5 MHz, and
55 MHz (the magnitude and phase of the voltage
 EOM_CktDiagram.JPGEOM_VoltagePlot.JPG 
  1696   Wed Jun 24 12:04:00 2009 ClaraUpdatePEMaccelerometer clarificationWhen I said "MC1/MC2 accelerometers,"
I meant the entire three-axis accelerometer
set at each point.
  
  1697   Wed Jun 24 12:04:22 2009 ZachUpdateCamerasSURF entryThis week, I've been reading some literature
concerning PLL and familiarizing myself with
LINUX, MATLAB, and high-pass filter circuits. 
  
  1698   Wed Jun 24 12:09:24 2009 ClaraUpdatePEMWeek 1(ish)I spent the week reading up on filter algorithm
theory, particularly Wiener filtering. I
have also learned how to get data from specific
  
  1699   Wed Jun 24 14:43:19 2009 robUpdateComputerstdsresp on linux => pzresp 
tdsresp is broken on our linux control
room machines.  I made a little perl
  
  1702   Thu Jun 25 17:27:42 2009 ranaUpdateComputerstdsresp on linux I downloaded the tdsresp.pl from LLO and put
it into the various TDS/bin paths. Also updated
the LLO specific path stuff. It runs.
  
  1703   Thu Jun 25 21:00:30 2009 ClaraUpdatePEMMC1 Accelerator set moved again; new XLR cablesI moved the MC1 set of accelerators. Might
have bumped things. If things aren't working,
look around the MC1 chamber.
  
  1704   Fri Jun 26 15:22:28 2009 ClaraUpdatePEMXLR cables tested and labeledWe now have two 80-foot, female-to-female
XLR cables for our pretty new microphones,
one yellow and one purple. They have been
 NC3FXX-EMC.pdfCat11_p35.pdf 
  1705   Fri Jun 26 18:00:36 2009 JenneUpdatePEMNew PEM channels for the fancy-pants new microphones[ Jenne, Clara ]
We made new channels for the microphones
which came in this week, by editing C1ADCU_PEM.ini
  
  1706   Fri Jun 26 19:14:04 2009 ranaUpdateEnvironmentseisBLRMS for the past 3 weeks[COLOR=chocolate][SIZE=2]Restarted the seisBLRMS.m
on mafalda (running a term on op540m). Don't
know why it stopped - the
  
  1707   Sat Jun 27 02:48:09 2009 ClaraUpdatePEMI moved accelerometers and made some pretty picturesI have been working on finding the best
spots to put the accelerometer sets in order
to best subtract out noise (seismometers
 6x 
  1708   Sat Jun 27 03:16:16 2009 ClaraUpdatePEMExciting microphone things!So, I'm double-posting, but I figured the
last post was long enough as it was, and
this is about something different. After
 mic_voltage_out.pngvoltage_dividers.pngvoltage_divider_sketch.png 
  1709   Tue Jun 30 23:09:40 2009 AlbertoUpdateLockingchronicles of some locking attemptsTonight I tried to lock the interferometer.
At the first attempts the arm power didn't
go above about 4. The mode cleaner seemed
  
  1710   Wed Jul 1 10:56:42 2009 Chris ZimmermanUpdateGeneralWeek 2/3 UpdateI spent the last week working a lot with
the differences between a basic Michelson
readout and the new one as a displacement
  
  1711   Wed Jul 1 11:00:52 2009 StephanieUpdateGeneralMultiply Resonant EOM UpdateSince last week, I have come up with a
new circuit, which is shown in the attached
figure. The magnitude (solid) and phase (dashed)
 EOMCKT.pngPR1_VoltagePlot.pdf 
  1712   Wed Jul 1 11:04:27 2009 ZachUpdateCamerasGigE Phase CameraThis past week, I have building a sine
wave rectifier and trying to write a simple
program that displays a ccd image to familiarize
 trigger.jpgfig1b.pdf 
  1713   Thu Jul 2 05:27:12 2009 ClaraUpdatePEMVoltage Divider OopsI tested the voltage dividers and was getting
up to about 3V. I retested the mic w/o the
voltage divider in place, and, lo and behold,
 voltage_divider_diagram.png 
  1714   Thu Jul 2 06:31:35 2009 ClaraUpdatePEMFirst mic in place and connectedI clamped Bonnie (microphone) to the top
of a chamber near the vertex of the arms
and placed Clyde (pre-amp) on the table right
 bonnieandclyde.JPG 
  1715   Thu Jul 2 16:45:06 2009 ClaraUpdatePEMBonnie and Clyde are officially in operation! (Butch Cassidy and the Sundance Kid are in temp position)I hooked up Bonnie and Clyde last night
and tested it today. First I tried some loud
noises to make sure I could identify them
 bonnie_test_marked.pngbonnie_test2_marked.pngbonniebutch_2sbeat_marked.png 
  1716   Thu Jul 2 17:37:36 2009 steveUpdateVACV1 interlock testJoe, Alberto and Steve
We tested gate valve V1 interlock
by :
  
  1718   Tue Jul 7 16:06:59 2009 ClaraUpdateComputer Scripts / ProgramsDTT synchronization errors, help would be appreciatedI am attempting to use the DTT program
to look at the coherence of the individual
accelerometer signals with the MC_L signal.
  
  1719   Wed Jul 8 10:56:04 2009 StephanieUpdateGeneralMultiply Resonant EOM UpdateThis week, I've been working on adapting
the last week's circuit to make it buildable.
Mostly this has involved picking components
 DSC_0566.JPGInitialBuiltCkt.pdfBuiltCkt_ExpectedResponse.png 
  1720   Wed Jul 8 11:05:40 2009 Chris ZimmermanUpdateGeneralWeek 3/4 UpdateThe last week I've spent mostly working
on calculating shot noise and other sensitivities
in three michelson sensor setups, the standard
 NSD_Displacement.png 
  1721   Wed Jul 8 11:08:43 2009 ZachUpdateCamerasGigE Phase CameraThe plan for the optical setup has been
corrected after it was realized that it would
be impossible to isolate a 29.501 MHz frequency
 fig1.pdffig2.pdf 
  1723   Wed Jul 8 12:36:15 2009 ClaraUpdatePEMCoherences and thingsAfter setting up the microphones last week,
I modified the Wiener filtering programs
so as to include the microphone signals.
 7x 
  1725   Wed Jul 8 19:13:19 2009 AlbertoUpdatePSLPSL beam aligned to the Mode CleanerToday I tuned the periscope on the PSL
table to align the beam to the Mode Cleaner.
With the Wave Front Sensor control off, I
  
  1726   Wed Jul 8 19:42:37 2009 ClaraUpdatePEMBonnie moved to PSL, getting some coherence with the PMC_ERR channelIn her position overlooking whichever table
it is that is next to the PSL, Bonnie drummed
up some decent coherence with the PSL-PMC_ERR
 DSC_0567.JPGbonnie2_pmcerr.pdfbonnie_PSL.pdf 
  1727   Thu Jul 9 02:18:09 2009 ranaUpdatePEMBonnie moved to PSL, getting some coherence with the PMC_ERR channelMy guess is that we need a different acoustic
strategy. The microphones are mainly for
high frequencies, 
  
  1728   Thu Jul 9 19:05:32 2009 ClaraUpdatePEMmore mic position changes; mics not picking up high frequenciesBonnie has been strung up on bungees in
the PSL so that her position/orientation
can be adjusted however we like. She is now
 6x 
  1729   Thu Jul 9 19:24:50 2009 ranaUpdatePEMmore mic position changes; mics not picking up high frequenciesMight be the insidious 850 Hz AA filters in
the black AA box which precedes the ADC.
  
  1730   Fri Jul 10 17:32:08 2009 ranaUpdateEnvironmentseisBLRMS & mafalda restartedRana, Alberto

Mafalda's ethernet cable had fallen out of
  
  1737   Mon Jul 13 15:14:57 2009 AlbertoUpdateComputersDAQAWGToday Alex came over, performed his magic
rituals on the DAQAWG computer and fixed
it. Now it's up and running again.
  
  1739   Mon Jul 13 16:59:10 2009 ZachUpdate GigE Phase CameraToday, I moved the router from on top of
the PSL into the control room in order to
perform dark field tests on the GC650 (which
  
  1742   Tue Jul 14 00:57:11 2009 AlbertoUpdateLockingphotodiode alignment checkSince lately the alignment of the input
beam to the interferometer has changed, I
went checking the alignment of the beam on
  
  1744   Tue Jul 14 16:31:46 2009 ClaraUpdatePEMFrequency Response of Microphone (Bonnie)So, I actually took these measurements
last week, but I didn't get around to making
nice plots and things until now. I figured
 Bonnie_fres_regplot.pdfBonnie_fres_logplot.pdf 
  1746   Wed Jul 15 08:59:30 2009 steveUpdateComputersfb40m The fb40m just went out of order with status
indicator number 8
It recovered on its own five minutes
  
  1747   Wed Jul 15 11:38:31 2009 robUpdateLockingMC_F channel deadIt's railed.  This is what halted
locking progess on Monday night, as this
channel is used for the offloadMCF script,
 mcfdead.png 
  1748   Wed Jul 15 12:11:17 2009 StephanieUpdateGeneralMultiply Resonant EOM UpdateThis week I've been working on testing
the first version of the prototype circuit.
Initially, I tested the circuit that I built
 MeasuredTransferFunction_R.jpgBuiltCkt_ExpectedResponse.pngMeasuredTransferFunction.jpg 
  1749   Wed Jul 15 12:14:08 2009 AlbertoUpdateLockingphotodiode alignment check


   
        
            
 2009-07-15_PD9spectrumPDF.pdf 
ELOG V3.1.3-