  2618   Fri Feb 19 15:29:14 2010 kiwamuUpdateCOCGluing dumbbells and magnetsJenne and kiwamu
We have
  
  12305   Fri Jul 15 16:23:51 2016 ericq UpdateGeneralGluing setbacks[ericq, Lydia]

Here is a picture of the ETMX guide
rod post-gluing. There is unfortunately a
 IMG_2768.JPGIMG_2771.JPG 
  5850   Wed Nov 9 16:03:21 2011 kiwamuSummaryGeneralGoal this weekGoal of this week : 
ALS on the Y arm
  
  5885   Mon Nov 14 11:32:02 2011 kiwamuSummaryGeneralGoal this weekGoal of this week : Noise
budgeting on the Y arm ALS
  
  3651   Tue Oct 5 14:11:09 2010 josephb, alexUpdateCDSGoing to from rtlinux to Gentoo requires front end code clean outApparently when updating front end codes
from rtlinux to the patched Gentoo, certain
files don't get deleted when running make
  
  13304   Fri Sep 8 12:08:32 2017 GabrieleSummaryLSCGood reconstruction of PRMI degrees of freedom with deep learningIntroduction

This is an update
of my previous reports on applications of
deep learning to the reconstruction of PRMI
 full_real_data_2017_09_06b_100x4_4000_300_20_free_swinging_time_domain.png.pngfull_real_data_2017_09_06b_100x4_4000_300_20_free_swinging_free_swinging_histograms2d.png.pnggru_2017_08_13a_100x4_4000_300_20_free_swinging_simulation_reference.png.png 
  14044   Sun Jul 8 12:20:12 2018 JonSummaryAUXGouy Phase Measurements from AUX-Laser ScansThis note reports analysis of cavity scans
made by directly sweeping the AUX laser carrier
frequency (no sidebands). The measurement
 yarm_aux_carrier_trans.pdfprmi_aux_carrier_trans.pdfdrmi_aux_carrier_trans.pdf 
  Draft   Wed Jul 11 18:13:19 2018 keerthanaSummaryAUXGouy Phase Measurements from AUX-Laser ScansFrom the Measurement Jon made, FSR is 3.967
MHz and the Gouy phase is 52 degrees. From
this, the length of the Y-arm cavity
  
  14822   Thu Aug 1 13:55:34 2019 DuoBureaucracyEquipment loanGpib module taken to QIL labvanna --> QIL.

gautam
20190804: The GPIB module + power supply
  
  4433   Wed Mar 23 14:19:35 2011 KojiSummaryGeneralGrand PlanThis is the grand plan we talked about
in the beginning of the meeting.

    (Kiwamu) X-end Green cleaning
  
  3018   Sun May 30 22:18:49 2010 ranaUpdatePEMGranite slab w/ lead balls is so far a flopThe seismometers showed an increased
noise in the Y-direction when put on top
of the granite slab. By tapping the slab,
  
  3022   Mon May 31 22:52:57 2010 ranaUpdatePEMGranite slab w/ lead balls is so far a flopThis plot shows the noise with the box
on, but no granite. We're still pretty far
off from the Guralp data sheet.
 Untitled.pnghuddlez.pnghuddlez.png 
  8414   Thu Apr 4 13:39:12 2013 Max HortonUpdateSummary PagesGraph LimitsGraph Limits: The limits on graphs
have been problematic.  They often reflect
too large of a range of values, usually because
  
  3418   Fri Aug 13 01:53:12 2010 GopalUpdateOptic StacksGravity Implementation ConfirmedTime Domain
Analysis on a Driven, Damped Simple Pendulum
 Pendulum_Length.pngPendulum_Length.pngPendulum_Length.png 
  15062   Tue Dec 3 00:03:57 2019 gautamUpdateLSCGreen ALS also shows elevated noise with high arm buildupSummary:  ALSnoiseIncrease_greenBeat.pdf 
  15058   Mon Dec 2 00:27:20 2019 gautamUpdateALSGreen ALS resurrectionAttachment
#1 -
 ALSnoiseComparison.pdfALS_TR_RIN.pdfGreemAM.pdf 
  9406   Tue Nov 19 00:18:30 2013 JenneUpdateLSCGreen ALS wishlistEricQ said that he's going to start hanging
out at the 40m a bit, and I was thinking
about what I can have him help me with. 
  
  16845   Wed May 11 15:49:42 2022 JCUpdateOPLEV TablesGreen Beam OPLEV Alignment[Paco, JC]

Paco and I began aligning the Green
Beam in the BS Oplev Table. while aligning
 IMG_0770.jpeg 
  2907   Mon May 10 20:03:22 2010 KevinUpdateGreen LockingGreen Laser Beam ProfileKiwamu and Kevin measured the beam profile
of the green laser by the south arm ETM.
The following measurements were made
 vbp.jpgvbp_residuals.jpghbp.jpghbp_residuals.jpg 
  2909   Mon May 10 22:25:03 2010 KojiUpdateGreen LockingGreen Laser Beam ProfileHey, what a quick work!
But,
wait...
  
  2910   Tue May 11 14:39:17 2010 AidanUpdateGreen LockingGreen Laser Beam Profile 
 Here's a photo of the set-up
used. The beam profile is measured relative
 P5110057_beams.jpg 
  2912   Tue May 11 17:02:43 2010 KevinUpdateGreen LockingGreen Laser Beam Profile 

 vbp.jpgvbp_residuals.jpghbp.jpghbp_residuals.jpg 
  2916   Wed May 12 03:42:38 2010 KojiUpdateGreen LockingGreen Laser Beam ProfileStrange.
I thought the new  result became twice of
the first result. i.e. w0=32um or so. 
  
  2933   Fri May 14 16:14:37 2010 KevinUpdateGreen LockingGreen Laser Beam Profile

    
        
 profile.pngresiduals.png 
  9442   Wed Dec 4 21:41:09 2013 ericqUpdateGreen LockingGreen PDH Characterization My job right now is to characterize
the green PDH loops on each arm. Today, Jenne
took me around and pointed at the optics
  
  9447   Fri Dec 6 12:45:51 2013 ericqUpdateGreen LockingGreen PDH CharacterizationYesterday, made a slew of measurements
on the X-arm when locked on green. By tweaking
the temperature loop offset and the green
 LoopTF.pdfServoTF.pdfMixerOutput.pdfServoOutput.pdf 
  10446   Wed Sep 3 18:42:43 2014 JenneUpdateLSCGreen PDH box boostsFrom EricQ's simulations reported in elog
10390, we want to transition from ALS
 BoostCartoon.pdf 
  10448   Thu Sep 4 00:56:44 2014 JenneUpdateLSCGreen PDH box boostsOkay, went back to the drawing board with
Rana and Koji on PDH box stuff.
Currently (at least for the Yend),
 TFstage_newDesign_3Sept2014.pngBoostNoBoost_newDesign_3Sept2014.pngBoostOnly_newDesign_3Sept2014.pngD0901351-v1_3Sept2014.pdf 
  10450   Thu Sep 4 03:12:55 2014 ericqUpdateLSCGreen PDH box boostsJenne made her board modifications, and
the measured TF agreed with the design. Alas,
the green would not lock to the arm in this
 boostedTF.pdfgain.jpg 
  10452   Thu Sep 4 16:45:10 2014 JenneUpdateLSCGreen PDH box boostsAs EricQ mentioned in last night's elog,
the modifications were made to the Yend (SN
17) uPDH board.
 IMG_1712.JPGIMG_1714.JPG 
  10458   Fri Sep 5 05:32:57 2014 JenneUpdateLSCGreen PDH box boosts[Rana, Jenne, EricQ]
* Too much gain overall on Yend box,
needed attenuator on output to get lock. 
 TRX_TRY_ALSvsIR_4Sept2014.pdf 
  12097   Thu Apr 28 15:23:11 2016 ericqUpdateLSCGreen PDH demod lowpassThe 2F product out of the mixer is a natural
concern when demodulating. However, I think
this isn't so big of a deal in our green
  
  12098   Thu Apr 28 18:53:05 2016 ranaUpdateLSCGreen PDH demod lowpassOK - but give us a circuit diagram and
the expected before/after loop plots. Got
to make sure we keep the right impedance
  
  12101   Fri Apr 29 16:13:36 2016 ericqUpdateLSCGreen PDH demod lowpassWe can get
as much, if not more, attenuation of the
1F line in the mixer output that we get from
 IMG_3186.jpgpdh_lpf.pngelp_liso.zip 
  12110   Fri May 6 16:42:12 2016 ericqUpdateLSCGreen PDH demod lowpassI've build the filter, and it seems
to have the desired TF shape.

 pdh_lpf.pngAUX_X_PDH_OLG_May6.png 
  12111   Fri May 6 19:08:52 2016 ranaUpdateLSCGreen PDH demod lowpassSeems weird to design a PD lowpass with
a corner at the modulation frequency. Recall
what our strategy is with the other photodetectors
  
  12112   Sat May 7 09:40:40 2016 ericqUpdateLSCGreen PDH demod lowpassAs I was looking at filter designs, it
seemed difficult to get 40dB of supression
at 2F with a bandpass without going to a
  
  12113   Sun May 8 08:39:21 2016 ranaUpdateLSCGreen PDH demod lowpassIndeed. This is why the LSC PDs have a
2f notch in addition to the 1f resonance.
In recent versions, we also put a 2f notch
  
  10462   Fri Sep 5 21:13:57 2014 JenneUpdateLSCGreen PDH out of loopI locked the arms with IR, and measured
the beatnote spectra to get the out of loop
noise for the PDH boxes. 
 ALS_XY_outOfLoop_5Sept2014.pdf 
  10296   Wed Jul 30 10:16:54 2014 AndresUpdate40m Xend Table upgradeGreen Steering Mirror Upgrade completedGreen Steering Mirror Update
Yesterday,
Nick and I completed the green steering mirrors
upgrade. I attached the file that contained
 XarmUpgrade.pdfdWaistSize_dlensVsdWaistPosition_dlens.pngXarmNewOpticalSetup.PNG 
  4267   Thu Feb 10 00:23:25 2011 JenneUpdateGreen LockingGreen TRX DC PD installed on PSLUsing a stray beam that is generated as
the transmitted green beam from the Xarm
goes through the viewport to the PSL table,
  
  6855   Fri Jun 22 17:51:04 2012 JenneUpdateCamerasGreen Trans camera repositioning attempt[Yuta, Jenne]
We tried to find a different place,
not in the main green transmitted beam path,
  
  16844   Tue May 10 18:25:43 2022 PacoUpdateBHDGreen Transmission path[Yuta, Paco]

We installed GRX_SM1,
GRX_SM2, and finished aligning
  
  12090   Tue Apr 26 23:19:42 2016 gautamUpdateendtable upgradeGreen aligned to arm - high order mode flashes seenAttachment #1

Layout as of today. Most of the
green path is done. The Green REFL PD + PZT
 IMG_2219.JPGIMG_2220.JPG 
  7347   Thu Sep 6 02:51:47 2012 KojiUpdateGeneralGreen beam roughtly aligned (Re: Yarm aligned to IR incident beam)The Y-End green beam was roughly aligned
by the steering mirrors for the green beam.
I couldn't understand the Y-End green
 green_y.png 
  11887   Wed Dec 16 18:34:40 2015 gautamUpdateGreen LockingGreen beat channels temporarily set up as IR beat channelsSince there
are a few hours to go before the locking
efforts tonight, I've temporarily borrowed
  
  11888   Wed Dec 16 23:15:28 2015 ericqUpdateGreen LockingGreen beat channels temporarily set up as IR beat channelsWith the IR beats going to the nominal
ALS channels as Gautam left them, we're
able to measure the free running frequency
 2015-12-16_AUXfreerunning.pdf 
  4480   Thu Mar 31 20:46:11 2011 AidanSummaryGreen LockingGreen beat note PD DC responseI measured the DC response of the Green
PD
  
  12603   Mon Nov 7 17:24:12 2016 gautamUpdateGreen LockingGreen beat setup on PSL tableI've been trying to understand the
green beat setup on the PSL table to see
if I can explain the abysmal mode-matching
 CurrentX.pdfCurrentY.pdfProposedShift_copy.pdf 
  12609   Wed Nov 9 23:21:44 2016 gautamUpdateGreen LockingGreen beat setup on PSL tableI tried to realize an improvement in the
mode matching onto the BBPDs by moving the
lens mentioned in the previous elog in this
  