40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 8 of 335  Not logged in ELOG logo
ID Dateup Author Type Category Subject Text Attachments
  356   Tue Mar 4 19:14:09 2008 ranaConfigurationCDSTDS & SVN[COLOR=purple][I]Matt, Rob, Rana[/I][/COLOR]

[B][COLOR=chocolate]Today we added the TDS
  
  357   Tue Mar 4 20:14:02 2008 ranaConfigurationIOOMC AlignmentThe MC alignment was pretty far off. We were
getting TEM01 mode locks only. 
Rather than inspect what happened I just
  
  358   Tue Mar 4 23:22:32 2008 robDAQComputersc1susvme1&2 rebooted
I found that some channels from c1susvme1
and c1susvme2 were not being recording by
  
  359   Wed Mar 5 12:35:09 2008 JohnSummaryComputer Scripts / ProgramsPlot photodiode responses in MatLabA matlab function to plot the responses of
photodiodes. There's still plenty of room
for improvement but it should work for all
 PD6DeltaT.jpgPD6.jpgPDbw.jpg 
  360   Wed Mar 5 12:51:48 2008 JohnSummaryLSCInitial Ligo Arm finesse versus lambdaI've taken the coating recipes for the initial
ligo arm cavity from Rana's web page (ligo.caltech/edu/~rana/mat/)
and plotted the finesse as a function of
 FofLambdaLIGOI.jpg 
  361   Wed Mar 5 17:35:24 2008 ranaUpdateIOORFAM during MC lockI used an ezcaservo command to adjust the
offsets for Alberto's StochMon channels.
They [B][COLOR=green]are all
 rfam.pdf 
  362   Thu Mar 6 00:17:37 2008 robUpdateLockingDD handoff workingGot the DD (double demod) handoff scripts
working tonight, with just the DRMI.  So,
now acquisition with the single demod signals
  
  363   Fri Mar 7 00:47:54 2008 ranaConfigurationPEMRanger SS-1Yesterday evening around 7:30 PM, I changed
the Ranger seismometer from a 
vertical to a horizontal seismometer. To
 ss1.pdf 
  364   Fri Mar 7 17:10:01 2008 Max JonesUpdateComputersNoise Budget workNoise budget has been moved to the svn system.
A checked out copy is in the directory caltech.
From now on, I will try to use the work cycle
  
  365   Fri Mar 7 19:04:39 2008 steveOmnistructurePSLlaser pointerGreen laser pointer was found in my desk.
I blamed Rana for not returning it to me
after a conference talk.
  
  366   Mon Mar 10 02:05:08 2008 robUpdateLockingDRMI+2ARMs working better
Some encouraging progress on the locking
front tonight.  After the work on the DRM
  
  367   Mon Mar 10 20:46:41 2008 JohnConfigurationLSCETMY Trans PD & QPDI've placed a 10% reflector in the path from
ETMY to the trans and quadrant photodiodes.
  
  368   Tue Mar 11 23:14:01 2008 ranaConfigurationPEMAccelerometer and Seismometer movementsSteve and Matt moved the accelerometers and
seismometers today. 
The accelerometers are now placed around
 Acc.pdf 
  369   Wed Mar 12 00:36:52 2008 ranaConfigurationPEMAccelerometer and Seismometer movementsI used the MISO FIR Wiener matlab code to
see how well we might do in principle.
 finished.pdf 
  370   Wed Mar 12 00:40:35 2008 ranaConfigurationPEMAccelerometer and Seismometer movementsSame as above but with 2048 taps and a 128
Hz sample rate. Does much better at the 16
Hz bounce mode.
 mc2048-128.pdf 
  371   Wed Mar 12 00:47:26 2008 ranaConfigurationPEMAccelerometer and Seismometer movementsAnd this is a [COLOR=blue]cool snapshot[/COLOR]
showing how this operation used [B][COLOR=red]16
cores[/COLOR][/B] on [SIZE=5][B][COLOR=purple]menkar
 Screenshot.png 
  372   Wed Mar 12 23:05:44 2008 ranaUpdateIOOMC WFSthey are bad, somewhat

please fix
  
  373   Thu Mar 13 02:52:06 2008 LisaConfigurationLSCLocking with 3fToday we have tried to use the reflected signal
demodulated at 3*f1 ~ 99 MHz ([COLOR=chocolate][B]REFL31[/B][/COLOR])
for length control.
  
  374   Thu Mar 13 03:07:19 2008 LisaMetaphysicsEnvironmentCoolness at the 40mMy first (and hopefully not last) week at
the [COLOR=orange]40m lab[/COLOR] is ending
:(
  
  375   Thu Mar 13 12:11:58 2008 aivanovUpdateComputer Scripts / Programsrouting PEM -> ASS -> SUS_MCL
on ASS RFM 1 has PEM signals at
  
  376   Thu Mar 13 13:15:09 2008 aivanovUpdateComputer Scripts / Programsnew sfotware intall, backup filesNew:
op440m:40m>ls -alt /cvs/cds/caltech/target/c1susvme[12]/*.o
-rw-r--r--    1 controls staff       57920
  
  377   Thu Mar 13 18:20:29 2008 JohnUpdateGeneralNew Focus 4003 EOM 29.489MHzI measured the modulation index as a function
of drive power using an OSA. Agrees well
with spec of 0.2 rad/V.
 4003.jpg 
  378   Fri Mar 14 12:06:29 2008 josephbConfigurationCamerasGC750 looking at ETMX while lockedThe GC750 (CMOS) is currently looking at the
front of ETMX.  Unfortunately, its being
routed through a 10Mbit connection (which
 ETMX_zoom_exp_10000_750.tiff 
  379   Fri Mar 14 14:59:51 2008 josephbConfigurationCamerasComparison between GC650 (CCD) and GC750 (CMOS) looking at ETMXAttached are images taken of ETMX while locked.

The first two are 300,000 microsecond exposure
 ETMX_z2_exp_300000_650.tiffETMX_z2_exp_300000_750.tiffETMX_z2_exp_30000_650.tiffETMX_z2_exp_30000_750.tiff 
  380   Fri Mar 14 15:06:24 2008 robUpdateComputer Scripts / Programsrouting PEM -> ASS -> SUS_MCL[quote]
on ASS RFM 1 has PEM signals at
  
  381   Fri Mar 14 15:52:07 2008 robConfigurationLSCLSC code change
I've edited the LSC code to send different
signals to the ASS box.  Now, instead of
  
  382   Fri Mar 14 16:56:03 2008 DmassBureaucracyComputersNew 40m control machine.I priced out a new control machine from Dell
and had Steve buy it.
  
  383   Sun Mar 16 17:03:32 2008 robConfigurationCDSASS code change
I've updated the ass.mdl file in the directory:
  
  384   Mon Mar 17 18:30:48 2008 mevansConfigurationPEMAdaptive FilteringIt seems that adaptive filtering can achieve
results similar to those of the MISO FIR
Wiener (entry 369).  The adaptive code simulates
 mcacc_adaptive.png 
  385   Thu Mar 20 15:28:20 2008 steveUpdateVACtp2 's drypump replacedThe fore pump of tp2 was replaced at fore
line pressure 998m Torr
  
  386   Thu Mar 20 16:06:27 2008 robConfigurationLSCLSC code change
I changed the LSC code again.  I noticed
that when turning off the LSC (e.g., going
  
  387   Thu Mar 20 17:45:36 2008 ranaSummaryASSAdaptive Filtering in the ASS systemOver the past couple weeks we (Matt, Alex,
Rob, me) have worked on getting an adaptive
filter
  
  388   Fri Mar 21 09:02:03 2008 steveUpdateVACtp 2 failedSmall turbo #2 is the forepump of the maglev.
It failed last night, shut down the  maglev
and interlock closed V1
  
  389   Fri Mar 21 11:54:38 2008 robUpdateVACtp 2 failed[quote]Small turbo #2 is the forepump of the
maglev.
It failed last night, shut down the  maglev
  
  390   Fri Mar 21 17:01:21 2008 ranaConfigurationDMFLocale change on Mafalda & seisBLRMS restartEver since we moved the accelerometers to
be around the MC and changed their names,
the seisBLRMS
  
  391   Fri Mar 21 23:15:11 2008 ranaConfigurationPEMRanger SS-1: New SetupThe Ranger seismometer has been in a bad state.
Its output had been sent into a SR560 without
any termination.
  
  392   Fri Mar 21 23:17:47 2008 ranaConfigurationDMFseisBLRMS restartedI updated the seisBLRMS par file with the
new channel names of the accelerometers and
the seismometer and then
  
  394   Sat Mar 22 22:39:02 2008 mevansSummaryCDSDirect Form 2 filters are badHere I show a comparison between the filter
algorithm currently used in LIGO (Direct
Form II), and an alternative algorithm designed
 low-noise_filtering.pnglow-noise_zoom.pngFiltRT.zip 
  395   Sun Mar 23 00:43:08 2008 mevansHowToGeneralOnline Adaptive FilteringI wrote a short document about the OAF running
on the ASS.  Since there is no BURT setup,
I put a script in /cvs/cds/caltech/scripts
 OnlineAdaptiveFilter.pdf 
  396   Sun Mar 23 00:56:42 2008 JohnUpdateLSCMore on 3f We ended our last attempt at 3f locking concerned
about the beam size on PD6. I investigated
tonight. The beam was not obviously overfilling
  
  397   Sun Mar 23 10:42:54 2008 ValeraSummaryElectronicsRFAM of the RF stabilization box is measuredI reconstructed Tobin's setup to measure the
RFAM after the RF stabilization box in the
166 MHz modulation path.
 RFAM.zipamplitudenoise.pdf 
  398   Mon Mar 24 13:03:54 2008 robUpdateElectronicsHP4195A is back

[quote]The swept sine output looks totally
  
  399   Mon Mar 24 20:15:03 2008 JohnSummaryComputersc1susvme2c1susvme2 isn't behaving itself. It keeps
getting out of sync and/or giving a red status
light.
  
  400   Tue Mar 25 10:44:24 2008 robUpdateComputersc1susvme2[quote]c1susvme2 isn't behaving itself. It
keeps getting out of sync and/or giving a
red status light.
  
  401   Tue Mar 25 13:21:25 2008 AndreyUpdateComputersc1susvme2 is not behaving itself again    
  402   Tue Mar 25 15:56:09 2008 JohnUpdateTreasureAssorted picturesSome pictures scavenged from the D40.  D40.pdf 
  403   Tue Mar 25 16:34:47 2008 robUpdateComputersc1susvme2[quote][quote]c1susvme2 isn't behaving itself.
It keeps getting out of sync and/or giving
a red status light.
  
  404   Wed Mar 26 13:41:53 2008 AndreyHowToSUSModification of ''C1DRIFT_MONITOR''I learned how to modify the drift-monitor
 in MEDM so that values on it change colors
from green to yellow to red depending how
  
  405   Wed Mar 26 22:26:15 2008 JohnUpdateComputersc1susvmeI removed the fan and tweaked the timing cables
to see if they were the source of our problems.
I saw no effect. I'm leaving the fan off
  
  406   Fri Mar 28 16:18:18 2008 robUpdateComputersc1susvme2 statusc1susvme2 is getting worse and worse.  it
won't run for more than ~45 minutes without
fatally de-syncing.  for now I've turned
  
ELOG V3.1.3-