40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 8 of 344  Not logged in ELOG logo
Entry  Thu Sep 25 14:03:08 2008, josephb, Configuration, Computers,  
[quote]
We (Joe) need to buy a GigE card for linux1 and to also set up conlog and conlogger to run on Nodus.
[/quote]
Entry  Thu Sep 25 17:14:31 2008, rana, Configuration, General, new sitemap vegemite.png
 
Entry  Fri Sep 26 14:10:21 2008, Yoichi, Configuration, Computers, Lab laptops maintenance 
The linux laptops were unable to write to the NFS mounted directories. 
That was because the UID of the controls account on those compters was different from linux1 and other control room computers.
I changed the UID of the controls account on the laptops. Of course it required not only editing /etc/password but also dealing with
Entry  Fri Sep 26 19:08:43 2008, rana, Configuration, PSL, Refcav Trans: PD + Camera + Dumps 
I went out to improve the Refcav trans path.

I removed all ND filters to get rid of the fringing. 
Entry  Mon Sep 29 13:33:39 2008, josephb, Configuration, Computers, Gigabit network finished and conlog available on Nodus 
The last 100 Mb unmounted hub has been removed (or at least of the ones I could find).  We should be on a fully gigabit network with Cat6 cables and lots
and lots of labels.
Entry  Wed Oct 1 12:05:58 2008, Alberto, Configuration, Computers, "StochMon" added to the Alarm Handler 
John, Alberto,

we added the four channels of the RF Amplitude Monitor (aka StochMon) to the Alarm HAndler. First we modified the 40m.alh file just copying some lines
    Reply  Wed Oct 1 12:09:25 2008, Alberto, Configuration, Computers, "StochMon" added to the Alarm Handler 
[quote]John, Alberto,

we added the four channels of the RF Amplitude Monitor (aka StochMon) to the Alarm HAndler. So far I used just test values for the thresholds of green,
Entry  Wed Oct 1 23:21:03 2008, Yoichi, Configuration, PSL, Reference cavity reflection camera 
I re-centered the reference cavity reflection camera, which has been mis-aligned for a while.
I also tweaked an input steering mirror to make the alignment better. This resulted in the increase of the transmission PD voltage
from 8V to 9V.
Entry  Fri Oct 3 12:15:21 2008, Alberto, Configuration, IOO, C1iool0 rebooted 
This morning, in order to update the threshold values of the alarm handler for the StochMon, I rebooted the C1iool0 computer following the procedure in
the wiki, that is telnetting on it and typing CTRL+X. Apparently everything went well in the process.
Entry  Tue Oct 7 12:17:57 2008, Alberto, Configuration, Computers, Time reset on MEDM 
Yoichi, Alberto

I noticed the MEDM screen time was about 7 minutes ahead of the right time. The time on MEDM is read on channel C0:TIM-PACIFIC_STRING which takes it from
Entry  Wed Oct 8 12:35:56 2008, josephb, Configuration, Computers, New Network diagram for the 40m 40m_network_10-07-08.pdf
Attached is a pdf of the new network diagram for the 40m after having removed all of the old hubs.
Entry  Wed Oct 8 19:17:55 2008, Yoichi, Configuration, PSL, Laser power is slowly recovering 
This afternoon we (rich, steve, yoichi) shutdown the laser for the DC-DC converter installation. 
(we decided not to do so. Detail will be posted soon.)
After we turned on the laser again,the laser power has been recovering but very slowly.
Entry  Wed Oct 8 22:23:43 2008, Yoichi, Configuration, Electronics, Electronics work bench cleanup Cleanup.jpg
Yesterday, I cleaned up the electronics work bench. I figured that keeping the work bench
in order has larger effect on the work efficiency than buying expensive soldering stations. 
Whoever works there should clean up the table after the work to the state shown on 
Entry  Fri Oct 10 20:03:35 2008, Yoichi, Configuration, Computers, medm, dataviewer, dtt on 64 bit linux 
I compiled EPICS (base, medm and ezca) and dataviewer for 64 bit linux.
These are installed in /cvs/cds/caltech/apps/linux64/.
I also configured cshrc.40m to make it possible to run the 32bit dtt on 64bit machines.
Entry  Mon Oct 13 13:51:49 2008, pete, Configuration, PSL, attempt to measure FSS ref phase 
On Friday I began a measurement of the FSS reference phase.  The setup involves the following:
  + turn off the 166 MHz LO (top signal generator on 1Y2 rack)
  + bring FSS LO 21.5 MHz to the 166 MHz delay line phase shifter, and back out the phase shifter with a second length of cable
Entry  Tue Oct 14 14:19:36 2008, pete, Configuration, PSL, FSS ref phase 
Today I made several measurements which should yield the optimized phase for the FSS 21.5 MHz reference.  I made two sets of measurements, using the 166
MHz phase delay shifter.  For each phase value I made 5 measurements of a 500 kHz injection into test2 at 1 Vpp,  with the 4195 spectrum analyzer on in1
with the high impedance probe, 51 points, a 10 kHz range.  It was surprisingly noisy.  I will make plots using matlab to find the maximum, and hope for
Entry  Tue Oct 14 19:24:34 2008, Yoichi, Configuration, PSL, FSS light power reduced 
Rana, Yoichi

To change the gain distribution in the FSS, Rana reduced the VCO power for the AOM to reduce the light incident to the reference cavity.
Entry  Wed Oct 15 22:07:52 2008, pete, Configuration, PSL, FSS ref phase measurements phasedelay.png
Optimizing the FSS LO/RF phase at 500 kHz, above the servo band, proved to be noisy and those measurements were useless.  Today I repeated
the measurement at 35 kHz and got good signal to noise.  I've attached a plot of the 35 kHz peak in dBm as measured at IN2 by SR785, with 
an injection into TEST2 at 35 kHz with 0.2 Vpp, as a function of delay in ns given by the delay phase shifter normally used by the 166 MHz.  
    Reply  Thu Oct 16 09:47:49 2008, Yoichi, Configuration, PSL, FSS ref phase measurements 
[quote] I fit the bottom (quadratic) portion of this curve, and found an optimum delay of 25.8 ns, which can be implemented as 25.81 ns on the phase shift
box (25 + 1/2 + 1/4 + 1/16). [/quote]
Entry  Thu Oct 16 13:12:58 2008, pete, Configuration, PSL, phase between FSS reference outputs 
I verified the phase between the FSS reference outputs (used for LO and RF) using matched BNC cables.  I measured 0.95 degree (average of 12 scope measurements).
Entry  Thu Oct 16 16:26:26 2008, pete, Configuration, PSL, FSS phase matching cable installed 
RG 405 cable has a solid teflon dielectric, and a velocity factor of 0.69.  To get the 8.2 degrees of additional phase on the LO output at 21.5 MHz then
requires 22 cm of cable.  I made a cable that ended up being 21 cm long after I'd gained some experience putting on the connector.  It gives a phase difference
between LO and RF of about 10 degrees.  It is currently installed.
Entry  Fri Oct 17 16:43:10 2008, Yoichi, Configuration, Computers, mcup/down scripts on linux 
I made some changes to /cvs/cds/caltech/medm/c1/ioo/cmd/medmMCup and medmMCdown so that those can be run from medm on linux machines.
Entry  Mon Oct 20 15:02:00 2008, Yoichi, Configuration, Computers, /cvs/cds restored 
I moved missing files in /cvs/cds restored by Alan and Stuart to the original locations.
I confirmed autoburt runs, and dtt, which had also been having trouble running, runs ok now.
    Reply  Mon Oct 20 16:18:00 2008, Alan, Configuration, Computers, /cvs/cds restored 
[quote]I moved missing files in /cvs/cds restored by Alan and Stuart to the original locations.
I confirmed autoburt runs, and dtt, which had also been having trouble running, runs ok now.
Entry  Mon Oct 20 20:50:09 2008, Yoichi, Configuration, PSL, FSS board chip replacement 
A quick update.

I changed two AD797s on the FSS board to AD829s to mitigate the 50MHz oscillation, which I plan to report later.
Entry  Tue Oct 21 18:19:42 2008, Yoichi, Configuration, Computers, LISO and Eagle installed FSS_PC_Path.pdfAD829Stability.pngAD797Stability.pngFreqNoiseByAD829.png
I installed LISO, a circuit simulation software, into the control room linux machines.
I also installed a PCB CAD called Eagle to serve as a graphical editor for LISO.
I put a brief explanation in the wiki.
Entry  Thu Oct 23 20:47:28 2008, pete, Configuration, PSL, FSS LO calibration for MEDM fss_lo_calibration.png
Today I took a quick series of measurements to calibrate the FSS LO power measurement in the MEDM.  This was done by using the spec.an. to measure the 21.5
MHz peak in dBm at the LO input to the FSS box on the PSL table, and recording the MEDM value, for attenuations applied at the FSS REF box output ranging
from -5 dBm to -30 dBm.  
Entry  Fri Oct 24 10:06:16 2008, Yoichi, Configuration, IOO, MC gain and FSS gain changed 
Following the measurements of MC and FSS loop gains, I modified mcup script to set the MC VCO gain to 2dB (it was -4dB before).
I also changed the normal value of the FSS common gain to 7dB. The open loop transfer functions posted in the previous two entries
were measured with those settings.
Entry  Fri Oct 24 11:21:26 2008, pete, Configuration, PSL, FSS LO input calibrated in dBm 
Based on the measurements described in my previous elog, I created a new calc record in the file /cvs/cds/caltech/target/c1psl/psl.db
 
[CODE]grecord(calc, "C1:PSL-FSS_LOCALC")
Entry  Fri Oct 24 20:54:41 2008, rana, Configuration, Computers, linux2 
I have removed linux2 and its cables from the control room and put it into 1Y3 along with op340m.

When Joe next comes in we can ask him to Cat6 it to the rest of the world, although it already
Entry  Fri Oct 24 21:49:15 2008, Jenne, Configuration, PEM, Short Seismometer Cable 
Bad news regarding the cable that goes between the Guralp seismometer and the box that I've been working on:  it's too short by about a factor of 2.  Dang
it.  I've placed the seismometer underneath the Beam Splitter Chamber (where it needs to go), and started running the cable toward the ADC rack where box
was planned to go, and as Rana guessed earlier tonight, the cable isn't nearly long enough.  We have some options:  the seismometer can go back into the
Entry  Mon Oct 27 11:16:23 2008, Alberto, Configuration, IOO, StochMon Calibration 
I implemented the calibration for the four channels of the StochMon in the ioo EPICS database. Now the output of those channels, as shown in the medm screen,
gives the peak-to-peak amplitude in voltage of each frequency from the RFAMPD at the transmission of the MC, normalized by the DC output from the same
photodiode.
Entry  Mon Oct 27 14:48:27 2008, Yoichi, Configuration, PSL, EO shutter installed to the reference cavity 
I'm now preparing for cavity ring down measurements of the reference cavity.
An EOM for polarization rotation is installed between the two steering mirrors for the reference cavity.
The location is before the polarized beam splitter (used to pick-up the reflected light from the cavity) and 
    Reply  Tue Oct 28 12:01:01 2008, josephb, Configuration, Computers, linux2 
[quote]I have removed linux2 and its cables from the control room and put it into 1Y3 along with op340m.

When Joe next comes in we can ask him to Cat6 it to the rest of the world, although it already
Entry  Wed Oct 29 12:23:04 2008, Yoichi, Configuration, PSL, MZ alignment touched and the alarm level changed 
Since the MZ reflection is alarming all the time, I tried to improve the MZ alignment by touching the folding mirror.
I locked the X-arm and monitored the transmitted light power while tweaking the mirror alignment to ensure that the output beam pointing is not changed.
I changed the alignment only a little, almost like just touching the knob.
Entry  Thu Oct 30 20:39:47 2008, caryn, Configuration, PEM, temperature sensor  
We attached the temperature sensor box to the MC1/MC3 chamber with a C-clamp. We connected the temp sensor to a 2nd box with a short BNC. Bob set up a power
cable coming from the X-end towards the MC1/MC3 chamber(Thanks, Bob!) We soldered the end of Bob's power cable to a plug and attached it to the 2nd box
(The power supply enters through the 2nd box). A ~20ft BNC cable connects the output signal of the 2nd box to the tall thing by the PSL where all the signals
Entry  Sun Nov 2 20:21:58 2008, rana, Configuration, lore, HP 5550dtn (Grazia) set up on allegra 
I set up printing to grazia from allegra. The CUPS interface was not as straightforward as Tobin had made it seem in the Wiki. I had to type in the IP address
and port number by hand.
Entry  Mon Nov 3 19:18:47 2008, Alberto, Configuration, General, new elog 
Phil Ehrens kindly poured our elog's content in a CD that now is here at the 40m.
I've been trying to install the 2.7.5 version of the elog on Nodus, a Sun machine, but the installing procedure is different from linux and I dont' know
it. I tried to recompile the elog from the source code but the way gcc is called must be wrong because I get this error message:
    Reply  Mon Nov 3 21:38:32 2008, Yoichi, Configuration, General, new elog 
[quote]I tried to recompile the elog from the source code but the way gcc is called must be wrong because I get this error message:

nodus:elog-2.7.5>make
    Reply  Thu Nov 6 22:07:56 2008, rana, Configuration, Computers, ELOG compile on Solaris 
From the ELOG web pages:

Solaris:
Entry  Thu Nov 13 15:50:44 2008, Alberto, Configuration, General, GPS 10MHz clock rackstuff.pdf
The schematic of the 1Y7 rack that Alan pointed out (see attachment) don't represent anymore the actual rack.
First, with Yoichi we found that the GPS receiver for the 10 MHz is in a different position, 
on the other side of the VME computer. It seems to output 1 kHz, which also appears in some modulated way.
Entry  Wed Nov 19 10:32:11 2008, Alberto, Configuration, Electronics, All the Marconi Set to the Rubidium Frequency Standard 
I placed the SRS Rubidium FS275 over the PSL rack, next to the frequency counter. This one and the Marconi on the PSL rack have been connected to the 10MHz
output of the frequency standard. I set also the first Marconi, the one that used to drive the others, to external, direct frequency reference. [I]Now
[SIZE=3]it reads 166981718 Hz versus 166981725 Hz[/SIZE] measured by the frequency counter[/I]: 8 Hz difference.
    Reply  Wed Nov 19 18:02:18 2008, rana, Configuration, Electronics, All the Marconi Set to the Rubidium Frequency Standard 
Not sure what was going on before. I changed the frequency counter to use an AC coupled input, and had it average
for 50 seconds. The output now agrees with the Marconi front panel to less than 1 Hz. Its still not 0.000 Hz,
but not bad.
    Reply  Wed Nov 19 18:12:35 2008, rana, Configuration, IOO, new channel for MC drum modes 
I set up the lockin to take the MC Demod Board's Qmon signal, demodulate it at 27.5 kHz, and
put the output into a DAQ channel (I think its either MC_DRUM1 or MC1_TEMPS). However,
the MC_DRUM channel doesn't look like its getting anything in the DTT although it looked fine
Entry  Sat Nov 22 10:55:51 2008, Caryn, Configuration, IOO, Drum modes Lock-In settings changed 
I unhooked the MC Demod Board's Qmon signal from the Lock-In. Set the demodulation frequency to 31.11Hz with 1V amplitude, and
put the output into MC_DRUM1. DTT showed a ~30Hz peak. Dataviewer showed signal with amplitude ~20,000. 
Otherwise the settings were as Rana had them: Time Constant-100us,24dB/Sensitivity-200us/Low Noise
Entry  Mon Nov 24 16:43:34 2008, rana, Configuration, Computers, Alex and Jay took away some computers from the racks 
I was over at Wilson house and saw Jay and Alex bring in 3 rackmount computers. One was a Sun 4600 and
then there were 2 3U black boxes. I got the impression that these were the data concentrators or
data collectors or framebuilder test boxes. They said that they got these from the 40m and no one was 
Entry  Mon Nov 24 19:15:16 2008, rana, alberto, john, Configuration, Environment, temperature 
The PSL Room Temperature was alarming because it had gone above 23 C. This set off an unfortunate chain of events:

We found that the PSL HEPA was set low (20%). This is a fine setting for when no one is working in there but it
    Reply  Tue Nov 25 19:29:15 2008, rana, alberto, john, Configuration, Environment, temperature 
[quote]The PSL Room Temperature was alarming because it had gone above 23 C. This set off an unfortunate chain of events:

We found that the PSL HEPA was set low (20%). This is a fine setting for when no one is working in there but it
    Reply  Thu Nov 27 22:56:42 2008, rana, Configuration, Environment, temperature mc.png
8-)
Entry  Tue Dec 2 17:56:56 2008, Alberto, Rana, Configuration, PSL, MC Alignment 
In the attempt to maximize the Mode Cleaner transmission and minimize the reflection from the steering mirrors of the MC periscope, we could not get more
~2 V at the MC Trans PD and ~ 0.5 V at MC REFL_DC. As it turned out from the SUS Drift Monitor, the reason was that the MC optics had been somehow displaced
from the optimal position. 
ELOG V3.1.3-