40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 8 of 344  Not logged in ELOG logo
    Reply  Mon Feb 8 15:01:46 2010, rob, Update, ABSL, Suddenly a much better alignment of PRC 


    
        
            Quote:
        
        
            
            I just aligned PRM and locked PRC and I noticed that SPOB is much higehr than it used to be. It's now about 1800,
    Reply  Mon Feb 8 15:41:51 2010, Alberto, Update, ABSL, Suddenly a much better alignment of PRC 


    
        
            Quote:
        
        
            
            
            
    
    Reply  Tue Feb 9 09:07:06 2010, Alberto, Update, ABSL, PLL Characterization 2010-02-08_PRCtransmissivity_EntireFreqRange_VsFit.png


    
        
            Quote:
        
        
            
            Lately I've been trying to improve the PLL for the AbsL experiment so that it could handle larger frequency steps
Entry  Tue Feb 9 10:10:58 2010, Alberto, Update, ABSL, back to analog 
I want to try to do the measurement with the network analyzer used as local oscillator, instead of the Marconis that I'm using now. Tha could give me
better noise rejection. It would also give me information about the phase.
Also I wouldn't dislike abandoning the GPIB interfaces to acquire data.
Entry  Thu Mar 18 10:46:51 2010, Koji, Update, ABSL, PLL reconstructed 
Last night (Mar 17) I checked the PLL setup as Mott have had some difficulty to get a clean lock of the PLL setting.

    I firstly found that the NPRO beam is not going through the Faraday isolator well. This was fixed by aligning the steering mirrors before
the Faraday.
    Reply  Thu Mar 18 12:27:56 2010, Alberto, Update, ABSL, PLL reconstructed 


    
        
            Quote:
        
        
            
            Last night (Mar 17) I checked the PLL setup as Mott had some difficulty to get a clean lock of the PLL setting.
    Reply  Thu Mar 18 13:40:35 2010, Koji, Update, ABSL, PLL reconstructed 
We use the current PLL just now, but the renewal of the components are not immediate as it will take some time. Even so we need steady steps towards
the better PLL. I appreciate your taking care of it.


    
        
            
    Reply  Thu Mar 18 21:42:26 2010, Koji, Update, ABSL, PLL reconstructed 
I checked the setup further more.

    I replaced the PD from NewFocus 1GHz one to Thorlabs PDA255.
    I macthed the power level of the each beam.

Now
I have significant fraction of beating (30%) and have huge amplitude (~9dBm). 
    Reply  Mon Mar 22 22:11:26 2010, Mott, Update, ABSL, PLL reconstructed IMG_0150.JPG
 
 It looks like the PLL drifted alot over the weekend, and we couldn't get it back to 9 dBm.  We switched back to the new focus wideband
PD to make it easier to find the beat signal.  I replaced all the electronics with the newly fixed UPDH box (#17) and we aligned it to the biggest
    Reply  Mon Mar 22 23:37:32 2010, Mott, Update, ABSL, PLL reconstructed 2010-03-22_23.14.00.jpg2010-03-22_23.24.50.jpg
 
We have managed to lock the PLL to reasonable stability. The RF input is attenuated by 26 dBm and the beat signal locks very close to the carrier
of the marconi (the steps on the markers of the spectrum analyzer are coarse).  We can use the marconi and the local boost of the pdh box to catch
    Reply  Tue Mar 23 18:44:46 2010, Mott, Update, ABSL, PLL reconstructed NPRO_PLL_freqresp.png
 
 After realigning and getting the lock today, I tried to add in the SR785 to measure the transfer function.  As soon as I turn on the
piezo input on the PDH box, however, the lock breaks and I cannot reacquire it.  We are using an SR650 to add in the signal from the network analyzer
Entry  Fri Jun 17 16:05:07 2011, kiwamu, Update, ABSL, LightWave out of MOPA box DSC_3139_small.png
[Suresh / Kiwamu]
 We did the following things :
   - Took the LightWave NPRO out from the MOPA box
    Reply  Mon Jun 20 11:38:49 2011, kiwamu, Update, ABSL, I-P curve of LightWave M126-1064-700 IP_curve.png
The I-P curve of the LightWave NPRO (M126-1064-700), which was taken out from the MOPA box, was measured. It looks healthy.
 The output power can go up to about 1 W, but I guess we
    Reply  Mon Jun 20 13:48:25 2011, Koji, Update, ABSL, I-P curve of LightWave M126-1064-700 
Hmm. Was the current within the operating range? (i.e. Is it a 700mW laser or a 1W one?)
You can obtain the nominal operating current from the old EPICS values (or some elog entries).
Note that NPROs are designed to be healthy only at around the nominal pumping power 
    Reply  Mon Jun 20 16:44:02 2011, steve, Update, ABSL, I-P curve of LightWave M126-1064-700 
 
 Put the serial numbers into the elog. So we can identify the laser and controller in the future.
The old days the NPRO ( inside the MOPA ) was running ~1.7A  500 mW
Entry  Wed Jun 22 15:24:10 2011, kiwamu, Update, ABSL, got a laser controller for LightWave DSC_3150.JPGDSC_3153.JPG
Peter King came over to the 40m with a laser controller and gave it to us.
We will test it out with the LightWave NPRO, which was used for MOPA.
    Reply  Thu Jun 23 22:59:45 2011, kiwamu, Update, ABSL, I-P curve of LWE IP_curve_small.png
 The I-P curve was measured again,
but this time in a lower current range of 1.0-1.9 [A].
The plot below is the latest I-P curve.
Entry  Fri Jun 24 00:13:24 2011, kiwamu, Update, ABSL, beam profile measurement of LWE beam_profile.png
The beam profile of the LWE (LightWave Electronics) NPRO was measured.
Mode matching telescopes will be designed and setup soon based on the result of the measurements.
 
    Reply  Fri Jun 24 07:49:23 2011, steve, Update, ABSL, I-P curve of LWE with serial numbers 


    
        
            Quote:
        
        
            

            The I-P curve was
Entry  Thu Jun 30 03:26:40 2011, kiwamu, Update, ABSL, status update 
Status update of the absolute length (ABSL) measurement:
 - To accommodate the ABSL stuff, the AS path was relocated on the AP table.
     (In this evening Jenne was able to lock MICH with AS55, so it's working fine.)
    Reply  Thu Jun 30 14:11:55 2011, kiwamu, Update, ABSL, a photo of ABSL setup on the AP table ABSLsetup.png
Here is a picture of the latest ABSL setup at the east part of the AP table.
    Reply  Thu Jun 30 21:00:20 2011, kiwamu, Update, ABSL, fine alignment done 
(Just a quick report)
The fine alignment of the ABSL laser injection was successfully done.
I was able to see the DRMI fringings at the AS camera. The ABSL beam is injected from the AS port, therefore what I saw on the camera was the reflection
    Reply  Tue Jul 5 16:09:54 2011, kiwamu, Update, ABSL, some photos for ABSL setup APtable.pngPSLtable.png
Here I show two photos of the latest ABSL (ABSolute Length measurement) setup. 
Entry  Tue Jul 5 17:38:46 2011, kiwamu, Update, ABSL, ABSL laser frequency-locked RFsetup.png
In this past weekend the ABSL laser was successfully frequency-locked to the
PSL laser with a frequency offset of about 100 MHz.
In the current setup a mixer-based frequency discriminator is used for
Entry  Mon Aug 1 04:08:24 2011, kiwamu, Update, ABSL, Arm length measurement : cavity kick technique ETMY_kick.png
I made some attempts to measure the current length of the arm cavities by
using the mass-kicking technique.
However unfortunately I am running out my energy to complete the measurement,
    Reply  Tue Aug 2 16:55:21 2011, rana, Update, ABSL, Arm length measurement : cavity kick technique L.png


    
        
            Quote:
        
        
            

           I made some attempts to measure the current length of the arm
Entry  Thu Aug 4 09:42:19 2011, Koji, Update, ABSL, ABSL Laser shutter closed 
The shutter of the ABSL laser is closed for the vent work.
Entry  Fri Mar 8 12:57:57 2013, Annalisa, Update, ABSL, BS installed on ITMY table 
 Sendhil and I installed the S polarized BS on the ITMY table to steer the NPRO beam through the AR wedge and align it to the POY beam. 
We took a shutter from the BSPRM table (which was not used) and a beam dump from the AS table (which was used by the auxiliary laser already removed
and installed on the ITMY).
    Reply  Fri Mar 8 13:42:35 2013, Jenne, Update, ABSL, BS installed on ITMY table 
Re:  POY beam reduction.
We are able to lock the Yarm with the beam / gain as it is.  I had thought we might need to increase the DC gain in the whitening board by
a factor of 2, but so far it's fine.
Entry  Mon Mar 18 12:02:12 2013, Annalisa, Configuration, ABSL, ABSL setup for g-factor measurement of PRC 
Motivations
The ABSL technique has been already used in the past to measure the absolute length of the interferometer's optical cavities
by means of  an auxiliary laser source, as described in LIGO-P1200048-v3 and in Alberto Stochino
Entry  Wed Mar 27 21:53:21 2013, Annalisa, Update, ABSL, Beat note of ATF auxiliary laser 
After measuring the beat note, the "Alberto" NPRO auxiliary laser has been moved from the PSL table to the POY table. Its beam profile is going
to be measured. It's going to be used as green laser on the END table, in place of the broken one.
The auxiliary laser borrowed form ATF lab (which will be used for the ABSL measurement) has been set on the PSL table to make a measurement of
    Reply  Thu Mar 28 23:00:30 2013, Annalisa, Update, ABSL, Beat note of ATF auxiliary laser found 
 
The beat note for the ATF lab laser has been found. 
The measurement has been carried out in the same way as described in elog 8368.
Entry  Fri Apr 26 10:50:07 2013, Annalisa, Update, ABSL, ATF laser on PSL 
The ATF NPRO auxiliary laser has been moved on the PSL table. All the optics for beat note measurement are in place and alignment has been done.
The setup for this measurement is the same as described in elog 8333.
Entry  Wed Jul 16 09:27:17 2008, steve, Update, ALARM, PSL-FSS_RMTEMP alarm is false frmtemp2y.jpg
Morning alarm sound is good for people who does not drink coffee.
Our 40m alarm is on every morning.
Those whom are not here in the morning thinks that this beeping sound is inspirational.
Entry  Thu May 21 12:58:32 2009, rob, Configuration, ALARM, PEM count-half disabled 
I've disabled the alarm for PEM_count_half, using the mask in the 40m.alhConfig file.  We can't do anything about it, and it's just annoying.
Entry  Tue Jan 26 20:18:32 2010, rana, Configuration, ALARM, op540m: alarms and BLRMS and StripTool restored 
I turned the StripTool and ALARMS and BLRMS back on on op540m. Looks like it has been rebooted 5 days ago and no one turned these back on. Also, there
was a bunch of junk strewn around its keyboard which I restrained myself from throwing in the trash.
The BLRMS trends should be active now.
Entry  Thu Apr 23 23:07:23 2015, Dugolini, Frogs, ALARM, laptops warning popeye-and-spinach.jpg
Please!



Don't put laptops on the ISC Tables!
Entry  Sun Dec 20 23:23:54 2015, ericq, Update, ALARM, Rats. 
A small rat / large mouse just ran through the control room. Ugh.
Entry  Wed Dec 23 16:15:47 2015, rana, Omnistructure, ALARM, fire alarm 
Fire alarm went off several minutes ago. Talked to security and they said there was no fire. It beeped twice again just now. No one has been working
on the IFO today.
    Reply  Mon Jun 27 15:26:03 2016, Steve, Omnistructure, ALARM, fire alarm test fireAlarmTest.png
The fire alarm came on around 15:05  for about 2-3 minutes. We all  left the lab and counted heads.  I called Paul Mackel x2646 (cell
626/ 890- 3259) at Fire Protection Services. He said that this alarm test was planned and we should of got an email notice. Perhaps I missed that notes.




Entry  Wed Nov 14 14:35:38 2018, Steve, Update, ALARM, emergency calling list for 40m Lab  
It is posted at the 40m wiki with Gautam' help. Printed copies posted around doors
also.
Entry  Fri Sep 6 16:38:24 2019, aaron, Update, ALARM, Alarm noise from smart-ups machine under workstation? 
There was an alarm sound from the Smart-UPS 2200 sitting under the workstation. I see that the 'replace battery' light is red, and this
elog tells me that these batteries are replaced every ~1-4 years; the last replacement was march 2016. Holding down the 'test' button for 2-3
seconds results in the alarm sound and does not clear the replace battery indicator.
Entry  Tue Aug 1 19:23:06 2017, rana, Update, ALS, X - arm alignment 
Rana, Naomi

We dither locked the X arm and then aligned the green beam to it using the PZTs. Everything looks ready for us to do a mode scan tomorrow.

We got buildup for Red and Green, but saw no beat in the control room.
Entry  Wed Aug 9 12:35:47 2017, gautam, Update, ALS, Fiber ALS IMG_3942.JPG
Last week, we were talking about reviving the Fiber ALS box. Right now, it's not in great shape. Some changes to be made:


Supply power to the PDs (Menlo FPD310) via
a power regulator board. The datasheet says the current consumption per PD is 250 mA. So we need 500mA. We have the D1000217
Entry  Wed Aug 9 19:21:18 2017, gautam, Update, ALS, ALS recovery ALS_oolSpec.pdf
Summary:

Between frequent MC1 excursions, I worked on ALS recovery today. Attachment #1 shows the out-of-loop ALS noise as of
today evening (taken with arms locked to IR) - I have yet to check loop shapes of the ALS servos, looks like there is some tuning to be done.
    Reply  Mon Aug 14 16:24:09 2017, gautam, Update, ALS, Fiber ALS IMG_7471.JPGIMG_7472.JPGIMG_7473.JPGIMG_7474.JPG
Today, I borrowed the fiber microscope from Johannes and took a look at the fibers coupled to the PDs. The PD labelled "BEAT
PD AUX Y" has an end that seems scratched
(Attachments #1 and #2). The scratch seems to be on (or at least very close to) the core. The other PD (Attachments
    Reply  Wed Aug 16 20:24:23 2017, gautam, Update, ALS, Fiber ALS IMG_7476.JPGIMG_7477.JPGIMG_7478.JPGIMG_7479.JPG
Today, with Johannes' help, I cleaned the fiber tips of the photodiodes. The effect of the cleaning was dramatic - see Attachments #1-4, which are
X Beat PD, axial illumination, X Beat PD, oblique illumination, Y beat PD, axial illumination, Y beat PD, oblique illumination. They look much cleaner
now, and the feature that looked like a scratch has vanished.
Entry  Fri Aug 18 23:59:53 2017, gautam, Update, ALS, X Arm ALS lock 
[ericq, gautam]


I was just getting the IFO aligned, and single arm lock going, when EricQ came in and asked if we could get some ALS data.
ALS
beats seemed fine, in particular the X-Arm. The broad hump around ~70Hz that was present in my previous
    Reply  Sat Aug 19 01:35:08 2017, ericq, Update, ALS, X Arm ALS lock ALS_comparison.pdf
My motivation tonight was to get an up-to-date spectrum of a calibrated measurement of the out-of-loop displacement of an arm locked on ALS (using
the PDH signal as the out-of-loop sensor) to compare the performance of ALS control noise with the Izumi et al green locking paper. 

I was able to fish out the PSD from the paper from the 40m svn, but the comparison as plotted looks kind of fishy. I don't see why the noise
    Reply  Mon Aug 21 23:38:55 2017, gautam, Update, ALS, ALS out-of-loop noise ALS_21082017.pdf
I worked a little bit on the Y arm ALS today. 


Started by locking the Y arm to IR with POY, and then ran the dither alignment script to maximize Y arm transmission.
Green
TRY DC monitor was around 0.16, whereas I have seen ~0.45 when we were doing DRFPMI locking.
So I went to the Y end table and tweaked the steering
ELOG V3.1.3-