40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 8 of 171  Not logged in ELOG logo
Entry  Thu Apr 17 15:00:59 2008, steve, Update, VAC, vac controller computer to be replaced 
Now that Rosalba is up and running someone should step forward to volunteer for this job.

Old desk top at the Vacuum Rack should be replaced by a functional less old computer so
Entry  Thu Apr 17 20:17:37 2008, Andrey, Update, PEM, Two issues with our weather station 

I encountered two difficulties working with the "Weather Station".
Entry  Fri Apr 18 16:48:13 2008, Andrey, Update, PEM, Rain collector of weather station DSC_0520--before.JPGDSC_0537--after.JPG

Today the rain collector of our weather station was cleaned. As a result, we checked that the rain indication on the weather monitor and on the MEDM screens
is alive and working properly. I am adding some details about the roof sensors to the wiki-40 page about the weather station. See especially the link "More
Entry  Sun Apr 20 18:23:27 2008, rana, Summary, LSC, locking attempts quix.png
I noticed that the adaptive FF for the MC had stopped doing anything; this turned out 
to be that the MC lost lock and the mcdown script turned off the FF path to MC1.
Entry  Fri Apr 18 19:46:08 2008, rana, Update, ASS, check adaptive 0052_xray_thm45.jpg
I restarted the adaptive code today using 'startass' and 'upass'. 
I moved them into the scripts/ASS/ subdirectory.
    Reply  Mon Apr 21 12:58:42 2008, rob, Update, ASS, check adaptive 
[quote]

Caryn Palatchi (a Caltech undergrad who just started working with us)
Entry  Sun Apr 20 20:29:46 2008, rana, Update, Computer Scripts / Programs, tdsread bugs 
[COLOR=darkred]There seems to be a problem with reading the C1:IOO-MASTER_OVERFLOW field 
when it is read in as part of an array. The only way for me to describe it
is to just attach the terminal output in this entry...this is mainly [B]for
    Reply  Mon Apr 21 13:12:21 2008, rob, Update, Computer Scripts / Programs, tdsread bugs 
[quote][COLOR=darkred]There seems to be a problem with reading the C1:IOO-MASTER_OVERFLOW field 
when it is read in as part of an array. The only way for me to describe it
is to just attach the terminal output in this entry...this is mainly [B]for
Entry  Tue Apr 22 08:34:22 2008, josephb, Configuration, Cameras, Current Network Diagram Network.pdf
The attached network diagram has also been added to the 40m Wiki at http://lhocds.ligo-wa.caltech.edu:8000/40m/Image_Processing_with_GigE_Cameras
Entry  Sun Apr 20 23:39:57 2008, rana, Summary, SUS, MC1 electronics busted mcwfs.jpg
I spent some time trying to fix the utter programming fiasco which was our MCWFS diagonalization script.

However, it still didn't work. Loops unstable. Using the matrix in the screen snapshot is OK, however.
    Reply  Tue Apr 22 10:59:24 2008, rob, Update, SUS, MC1 electronics busted 
[quote]I spent some time trying to fix the utter programming fiasco which was our MCWFS diagonalization script.

However, it still didn't work. Loops unstable. Using the matrix in the screen snapshot is OK, however.
Entry  Fri Apr 18 16:02:58 2008, alex, Update, SUS, end station sus front-end bug fix 
installed and started new susEtmx.o and susEtmy.o to fix a problem with ETMY optical lever variables.
    Reply  Fri Apr 18 16:27:04 2008, rob, Update, SUS, end station sus front-end bug fix 
[quote]installed and started new susEtmx.o and susEtmy.o to fix a problem with ETMY optical lever variables.[/quote]

But where is the code?
    Reply  Tue Apr 22 16:17:48 2008, rob, Update, SUS, end station sus front-end bug fix 
[quote]installed and started new susEtmx.o and susEtmy.o to fix a problem with ETMY optical lever variables.[/quote]

What Alex means is that the EPICS values for the ETMY optical levers were being clobbered in the RFM.  The calculations were being done correctly in the
Entry  Tue Apr 22 17:08:04 2008, Caryn, Update, IOO, no signal for C1:IOO-MC_L  
C1:IOO-MC_L signal was at zero for the past few days
Entry  Tue Apr 22 22:19:02 2008, rob, Metaphysics, lore, jiggling sliders 

In the interests of tacit communication of scientific knowledge, I here reveal a nugget of knowledge which may or may not prove useful to new LIGOites:
sometimes when front-end machines are rebooted, the hardware they control can wind up in a state which is not accurately represented by the EPICS values
Entry  Tue Apr 22 22:51:30 2008, rana, Configuration, IOO, McWFS Status 
I've been working a little on the MC WFS in the last few days. I have made many 
changes to the sensing matrix script and also to the MCWFSanalyze.m script.
Entry  Wed Apr 23 22:39:54 2008, Andrey, DAQ, Computer Scripts / Programs, Problem with "get_data" and slow PEM channels 

It turns out that I cannot read minute trends for the slow weather channels for more than 1000 seconds back (roughly more than 15 minutes ago) using "get_data"
script.
Entry  Thu Apr 24 11:50:10 2008, josephb, Summary, Computer Scripts / Programs, Useful tidbits learned while tracking the network setup 
In process of understanding the network setup I've learned several things:

1) The status lights on C0DAQ_RFMNETWORK.adl are controlled by the fiber network, as opposed to the ethernet network.  However, even if everything is working
Entry  Thu Apr 24 14:10:26 2008, rob, Update, Locking, locking work 
[I]Rob, Johnnie[/I]

We made some progress on locking last night (Wed night), namely that we were able to handoff (briefly) the CARM-MCL path the REFL-DC error signal.  We
Entry  Thu Apr 24 15:57:53 2008, steve, Configuration, SAFETY, Safety at AP-ISCT P1020197.JPGmcrefl3.JPG
I measured the output power of the psl after the mechanical shutter.

It was 1.1 W with Ophir power meter, than unlocked the MC and measured
Entry  Thu Apr 24 22:06:47 2008, Andrey, Summary, Computers, Ethernet Cables and Hubs 
Today in the morning (between 8.30AM and noon) Joe and I were working on understanding which ethernet cables connect "processors controlling the work of
equipment in the interferometer room" and "Internet hub in the computer room".
Entry  Thu Apr 24 23:27:48 2008, rana, Update, PEM, acoustic noise in MC_F 
I looked at the [COLOR=darkblue][FONT=Comic Sans MS][SIZE=3]coherence between the Microphone in the PSL (PEM-AS_MIC) and the MC_F[/SIZE][/FONT][/COLOR]
channel.
Entry  Thu Apr 24 23:50:10 2008, rana, Update, General, Syringes in George the Freezer 
There are some packets of syringes in the freezer which are labeled as belonging to an S. Waldman.
Thu Apr 24 23:48:55 2008 
Entry  Fri Apr 25 11:33:40 2008, Andrey, Configuration, Computers, Computer controlling vaccum equipment 

[COLOR=blue]Old computer[/COLOR] (located in the south-end end of the interferometer room) that was almost unable to fulfill his duties of controlling
vacuum equipment [COLOR=blue]has been replaced to "Linux-3"[/COLOR]. MEDM runs on "Linux-3". 
Entry  Fri Apr 25 13:20:04 2008, Andrey, Update, PEM, Microphone test Microphone.png
In response to Rana's request, I tested the microphone (if it is alive or not) by clapping my hands and speaking aloud nearby.

The microphone is alive, see the attached "Full Data" for 5 minutes from Dataviewer.
Entry  Fri Apr 25 15:44:21 2008, steve, Update, PSL, scattering measurments 6x
In pursuit of a low back scattering, high power beam dump we looked at materials such:
polished copper, polished aluminum, diamond cut aluminum, variety of polished & heat treated stainless steel and shades of black glasses.
Black glass is ideal at low power. Superpolished SS 304 #8 is the only material that measures close to bg
Entry  Fri Apr 25 20:53:02 2008, rana, Configuration, IOO, MC WFS with more gain 
Quick update: we found that the reason for the MC WFS instability was that the digital anti-whitening was one but not the analog whitening.

We turned off the digital filters and were able to increase the gain by a factor of ~30. It is left like this, but if it hampers IFO locking then best
Entry  Sat Apr 26 01:45:38 2008, Andrey, Summary, PEM, Weather Station enhancement Matlab_Weather_Trends.png
Two more things concerning weather monitoring have been done during this week.

1) A Dataviewer template was created, so that it allows to see "real-time" information from weather channels immediately, without adding many channels
Entry  Sat Apr 26 11:21:15 2008, ajw, Omnistructure, Computers, backup of /cvs/cds restarted 
The backup of /cvs/cds (which runs as a cron job on fb40m; see /cvs/cds/caltech/scripts/backup/000README.txt) 
has been down since fb40m was rebooted on March 3.
I was unable to start it because of conflicting ssh keys in /home/controls/.ssh .
Entry  Sun Apr 27 02:11:11 2008, rana, Configuration, IOO, MC WFS Notes 
As noted in the elog from Friday, the WFS has been bad ever since someone switched on the digital whitening filters (FM1 & FM2)
in the MC WFS I&Q filter banks.
Entry  Sun Apr 27 05:09:30 2008, rana, Configuration, IOO, MC WFS Whitening turned on mcnoise.png
I [B]hardwired on the MC WFS whitening[/B] filters.

The MAX333A switches which choose between whitening and bypass on that board were in the bypass position
Entry  Sun Apr 27 18:11:58 2008, rob, DAQ, Computers, br40m? 

The testpoint manager (which runs on fb40m) crashed this afternoon.  Upon re-starting it, I found there was a rogue dtt process on op440m and also a daqd
daemon running on br40m.  One or both of these caused the tpman to crash.  br40m is the frame broadcaster, which is never used here as we don't run DMT.
    Reply  Sun Apr 27 22:57:15 2008, ajw, DAQ, Computers, br40m? 
[quote]
The testpoint manager (which runs on fb40m) crashed this afternoon.  Upon re-starting it, I found there was a rogue dtt process on op440m and also a daqd
daemon running on br40m.  One or both of these caused the tpman to crash.  br40m is the frame broadcaster, which is never used here as we don't run DMT.
Entry  Mon Apr 28 23:44:33 2008, Andrey, Update, Computer Scripts / Programs, Weather.db 

I was trying to figure out how to modify the file "Weather.db" so that the atm.pressure would be recalculated from Pa to bar before appearing in the EPICS
screen, but so far I did not succeed. [COLOR=blue]I restarted processor "c1pem1" several times.[/COLOR] I will continue this tomorrow, and also I will
Entry  Tue Apr 29 21:09:12 2008, rana, DAQ, CDS, FE Filters fefilters.jpgfefilters.txt
These are new FE filters for downsampling and upsampling. We will be going from native hardware sampling rates of 64k down to 32k, 16k, and 2k.

The attached plot shows these filters. They are 3dB ripple, 40 dB stopband, 4th order elliptic filters in which I have moved the zeros around
Entry  Tue Apr 29 21:30:49 2008, Andrey, Update, PEM, In the process of renaming channels for Weather Station 

I startted renaming channels for the weather station, and I will continue this tomorrow, on Wednesday.
Entry  Wed Apr 30 20:48:58 2008, Andrey, Summary, PEM, New Weather Channels April30-5hours.png

I created the new channels for the weather station, all letters are capital ones. They are of the form "C1 : PEM-WS_PARAMETER" where "PARAMETER" is temperature,
pressure, wind,... characteristics (names are self-obvious).
Entry  Thu May 1 08:31:51 2008, steve, Update, SUS, earthquake trips etmy & mc1 
Earthquake at Lake Isabel magnitude 4.4 at 1am today shakes the 40m
ETMY and MC1 watchdogs tripped.
Sus damping restored.
Entry  Thu May 1 12:46:02 2008, josephb, Configuration, Computers, Nodus gateway is up 
The computer Nodus is now acting as a gateway machine between the GC network and the martian network in the 40m.  It has the same passwords as the rana
gateway machine.
Entry  Fri Apr 25 13:53:11 2008, josephb, Summary, Computers, Network setup 40m_network_90.pdf
This is the promised more in detail summary from Andrey's log ID 444.

What we did was go around to each hub, one at a time, unplug the network connection, and figure out which light on which hub went out.  We then, went back
    Reply  Mon May 5 11:04:30 2008, rob, Omnistructure, Computers, Network setup 

Mafalda was not connected to the network, and so our DMF-based seisBLRMS has not been running for ~1 week.  I traced this to a broken ethernet cable connecting
mafalda to the network switch in the rack next to the B&W printer.  This cable has a broken connector at the switch side, which means it can't stay connected
Entry  Mon May 5 15:53:14 2008, steve, Update, VAC, drypump replaced & readbacks are out 
The small turbo pump of the annulus system is tp3
It's drypump was replaced at 1.4 Torr after 8 months of operation.
The rebuilding cost of this SH100 drypump is getting ridiculously high $1349.
Entry  Tue May 6 17:28:39 2008, rob, Configuration, LSC, AP33 -> POX33 

I am in the process of switching the POX166 and AP33 photodetectors, so that they become POX33 and AP166.  The IFO_CONFIGURE buttons won't work until I
finish.
    Reply  Wed May 7 15:25:41 2008, rob, Configuration, LSC, AP33 -> POX33 
[quote]
I am in the process of switching the POX166 and AP33 photodetectors, so that they become POX33 and AP166.  The IFO_CONFIGURE buttons won't work until I
finish.[/quote]
Entry  Thu May 8 01:07:24 2008, rana, Summary, LSC, Frequency Noise test: MC Trans Backscatter 
[COLOR=purple][SIZE=4][FONT=Arial]There is a wandering hump in the MC_F spectrum.[/FONT][/SIZE][/COLOR] It can move around on the time 
scale of seconds between 40 and 200 Hz. It has an amplitude ~5-50x above the background spectrum. This seems new; I don't remember it 
from a year ago. It is there in the IFO unlocked as well as the IFO locked as well as the locked + CM mode.
Entry  Thu May 8 01:50:25 2008, rana, Summary, ASC, Arm Cavity HOM Resonances 
Nothing new, but I calculated the frequencies of the first 22 higher order transverse modes and thought I might as well list them here.

To do this I took formula (23) from page 762 of Siegmans book and put it into this form:
Entry  Thu May 8 02:06:13 2008, rana, Summary, COC, Thermal Lensing in the ITMs and BS may be a problem 
The iLIGO interferometers start to see thermal lensing effects with ~2W into the MC, a recycling
gain of ~50, and a beam waist on the ITMs of ~3.5 cm.
Entry  Thu May 8 16:40:36 2008, josephb, Configuration, Cameras, Gige Camera currently on PSL table 
Andrey and myself were working on the PSL table today, using a pickoff of a pickoff of the main beam (adding a microscope slide to pickoff ~4% of the original
pickoff) to the GC750 GigeCam.
Entry  Fri May 9 08:40:24 2008, steve, Update, SUS, ETMY sus damping restored 
ETMY lost damping at 19:10 last night.
There was no seismic event than.
Sus damping was restored this morning. 
Entry  Fri May 9 10:15:36 2008, josephb, Update, Computers, Nodus has moved 
Steve and myself moved Nodus from under the table in the control room, to just above the Rana computer in the control room rack.
Entry  Tue May 13 10:15:52 2008, steve, Update, SUS, restored damping of BS & PRM 
I think our janitor was cleaning too heavy handedly.
The BS and PRM sus damping were lost.
They were restored.
Entry  Tue May 13 10:38:28 2008, steve, Update, Computers, rfm network is down 
The RFM network went down yesterday around 5pm
Only c1susvme1 is alive but it's timing is off.
Andrey is bringing the network up.
Entry  Wed May 14 13:14:19 2008, Andrey, Summary, Computers, Reflective Memory Network is restored 

[COLOR=blue]Reflective Memory Network is restored, all watchdogs and oplevs are returned to the "enabled" state.[/COLOR]
Entry  Wed May 14 14:05:40 2008, Andrey, Update, Computers, Computer Linux-2, MEDM screen "Watchdogs" 

Computer "Linux-2", MEDM screen "C1SUS_Watchdogs.adl": there is no indication for ETMY watchdogs, everything is white. There is information on that screen
"C1SUS_Watchdogs.adl" about all other systems (MC, ETMX,...), but something is wrong with indicators for ETMY on that particular control computer.
Entry  Thu May 15 10:40:21 2008, steve, HowTo, General, Lisa Goggin, PhD lisa.JPG
Lisa Goggin successfully defended her thesis on May, 13 2008

"A Search For Gravitational Waves from Perturbed Black Hole Ringdowns in Ligo Data"
Entry  Thu May 15 12:05:49 2008, josephb, Configuration, PSL, Path to PSL Position QPD 
The 50/50 beamsplitter that was being used as the last turning mirror to the PSL Position QPD has been replaced with a Y1-1037-45-S plate.  This turning
mirror was also moved 4" farther along the beam path, so as to produce as small (few microwatts) transmission through the plate.  The lensing optics were
also shifted so as to maintain a focused beam on the photodiode.  Lastly, the rotating ND filter was increased from 1.5 to 2.0 to reduce the incident power
Entry  Thu May 15 14:39:33 2008, Caryn, Summary, PEM, filtering mode cleaner with mic MC_L_with_PEM-AS_MIC_filter.pdfMC_L_with_PEM-ACC_MC1_X_filter.pdf
Tried filtering for mode cleaner data(C1:IOO-MC_L) using a siso-firwiener filter and microphone data(C1:PEM-AS_MIC) for noise input. The noise reduction
in mode cleaner data using the microphone-filter is comparable to the noise reduction when an accelerometer(C1:PEM-ACC_MC1_X) filter is used. See attached
graphs. 
ELOG V3.1.3-