  2998   Thu May 27 08:22:57 2010 AidanUpdateComputersRestarted the elog this morning    
  3061   Wed Jun 9 21:05:44 2010 ranaSummaryComputersop540m is not to be usedThis is a reminder (mainly for Steve, who somehow   
  3080   Wed Jun 16 11:31:19 2010 josephbSummaryComputersRemoved scaling fonts from medm on AllegraBecause it was driving me crazy while working
on the new medm screens for the simulated
plant, I went and removed the aliased font
  
  3081   Wed Jun 16 18:12:16 2010 nancyConfigurationComputers40MARSi added my laptop's mac address to teh
martian at port 13 today.
 
  
  3083   Wed Jun 16 18:44:07 2010 AlbertoConfigurationComputers40MARS


   
        
            
  
  3106   Wed Jun 23 15:15:53 2010 josephbSummaryComputers40m computer security issue from last night and this morningThe following is not 100% accurate, but
represents my understanding of the events
currently.  I'm trying to get a full
  
  3115   Thu Jun 24 13:02:59 2010 JenneUpdateComputersSome lunchtime reboots[Jenne, Megan, Frank]
We rebooted c1iovme, c1susvme1, and
c1susvme2 during lunch.  Frank is going
  
  3120   Fri Jun 25 12:09:27 2010 kiwamuUpdateComputersGPIB controller of HP8591EI've
just stolen a GPIB controller, an yellow
small box, from the spectrum analyzer HP8591E.
  
  3159   Tue Jul 6 17:05:30 2010 Megan and JoeUpdateComputersc1iovme rebootWe rebooted c1iovme because the lines stopped
responding to inputs on C1:I00-MC_DRUM1.
This fixed the problem.
  
  3172   Wed Jul 7 22:22:49 2010 JenneUpdateComputersSome channels not being recorded!!![Rana, Jenne]
We discovered
  
  3176   Thu Jul 8 14:11:16 2010 josephbUpdateComputersSome channels not being recorded!!!This has been fixed,
thanks to some help from Alex.  It doesn't
  
  3178   Thu Jul 8 15:19:27 2010 josephb, kojiConfigurationComputersAdded Zonet camera to IP table on linux1We gave the Zonet camera the IP 192.168.113.26
and the name Zonet1.
We did this by modifying the /var/named/chroot/var/named/113.168.192.in-addr.arpa.zone
  
  3179   Thu Jul 8 15:43:58 2010 ranaUpdateComputersSome channels not being recorded!!!

    
        
 3-monkeys-ComicPosition.gif 
  3185   Fri Jul 9 11:09:14 2010 josephbUpdateComputersFb40m and a few other machines turned off briefly just before 11amI turned off fb40m2 and fb40m temporarily
while we added an extra power strip 
to the (new) 1X6 rack at the bottom in the
  
  3226   Thu Jul 15 11:58:50 2010 josephbUpdateComputersAdded channel to ADCU_PEM (C0DCU1)I modified the C1ADCU_PEM.ini file in /cvs/cds/caltech/chans/daq/
(after making a backup), and added a temporary
channel called C1:PEM-TEMP_9, the 9 corresponding
  
  3237   Fri Jul 16 15:57:19 2010 josephb,kiwamuUpdateComputersNew X end FE and IO chassis workWe finished setting up the new X end front
end machine (still temporarily called c1scx),
and attached it to its IO chassis. 
  
  3238   Fri Jul 16 16:07:14 2010 josephbUpdateComputersPossible solution for the last ADC After talking with Jenne, I realized the
ADC card in the c1ass machine was currently
going unused.  As we are short an ADC
  
  3239   Fri Jul 16 16:12:31 2010 AlbertoConfigurationComputersc1susvme1/2 rebootedToday I noticed that the FE SYNC counters
of c1susvme1/2 on the RFM network screen
were stuck at 16384. I tried to reboot the
  
  3257   Wed Jul 21 12:20:29 2010 josephb, kiwamuUpdateComputersMegatron temporarily disconnected, c1iscex firewalled, green FE testWe are moving towards a first test of getting
Kiwamu's green locking signals into the new
front end at the new X end, as well as sending
  
  3308   Wed Jul 28 12:53:32 2010 channaUpdateComputersnds data listenerFor the sake of writing it down: /cvs/cds/caltech/apps/linux64/rockNDS   
  3310   Wed Jul 28 14:34:29 2010 channaUpdateComputersinstallation on allegraI have done the following on allegra and
rosalba:
[root@allegra caltech]# yum install
  
  3419   Fri Aug 13 09:41:00 2010 nancyOmnistructureComputersCharger for dell laptop I have taken the charger for the
dark gray dell laptop from its station, and
have labelled the information there too.
  
  3433   Wed Aug 18 12:02:29 2010 AlastairConfigurationComputerselog had crashed again......I restarted it.   
  3441   Thu Aug 19 09:52:51 2010 AlastairUpdateComputersElog down I restarted it using start-elog-nodus
and this worked out fine - even though I
did it from Pete's on my phone ;-)
  
  3442   Thu Aug 19 11:38:48 2010 AlastairUpdateComputersATF wikiThe ATF wiki page doesn't seem to be working
any more.  Does anyone know where this
is held so we can try to get it back online? 
  
  3443   Thu Aug 19 12:06:07 2010 AlastairUpdateComputersATF wiki


   
        
            
  
  3476   Fri Aug 27 11:24:13 2010 JenneOmnistructureComputersop540m deadI think op540m
has finally bitten the dust. 
  
  3485   Sun Aug 29 21:18:00 2010 ranaUpdateComputerskallo -> rossaWe changed the name of the new control
room computer from kallo to rossa (since
its red).
  
  3486   Mon Aug 30 11:41:34 2010 kiwamuUpdateComputersdisable sendmail and isdn {Rana and Kiwamu}
Yesterday we disabled the sendmail
daemon and the isdn daemon on allegra because
  
  3517   Thu Sep 2 21:22:31 2010 Sanjit, KojiConfigurationComputersrossa nvidia driver and dual monitor configuration 
Simple steps (but don't try these
on a working computer without getting some
  
  3518   Thu Sep 2 23:35:33 2010 ranaConfigurationComputersrossa nvidia driver and dual monitor configurationWhy are we running CentOS 4.8 instead of
5.5 ?    What runs at LLO?    
What runs in Downs?
  
  3521   Fri Sep 3 11:23:16 2010 josephbConfigurationComputersrossa nvidia driver and dual monitor configurationAt LLO the machines are running Centos 5.5.
 A quick login confirms this.  Specifically
the release is 2.6.18-194.3.1.el5.



  
  3524   Sun Sep 5 21:35:41 2010 ranaConfigurationComputersrossa notes**** Deleted
apps/emacs
apps/linux64/firefoxold
  
  3526   Mon Sep 6 10:08:10 2010 AlbertoConfigurationComputersNetgear Network Switch fan broken.The Netgear Network Switch in the top shelf
of Nodus' rack has a broken fan. It is the
one interfaced to the Martian network.
  
  3531   Tue Sep 7 10:50:53 2010 josephbConfigurationComputersrossa notesThe controls group is user id 500 by default
on most new machines.  Unfortunately, the
user ID used across the already existing
  
  3535   Tue Sep 7 15:57:07 2010 AlbertoConfigurationComputersNodus connection not working. Fixed[Joe, Alberto]
The Nodus connection to the Martian
network stopped working after someone switched
  
  3537   Tue Sep 7 22:21:17 2010 AlbertoConfigurationComputerselog restarted    
  3539   Tue Sep 7 23:17:45 2010 sanjitConfigurationComputersrossa notes

    

       
            
  
  3540   Tue Sep 7 23:34:15 2010 Kiwamu, SanjitConfigurationComputerse-loge-log was repeatedly hanging and several
attempts to start the daemon failed.
problem was solved after clearing
  
  3541   Tue Sep 7 23:49:08 2010 sanjitConfigurationComputersaldabella network configuration 
added name server 192.169.113.20
as the first entry in /etc/resolv.conf
  
  3557   Sat Sep 11 03:16:51 2010 ranaConfigurationComputersrossa notesI wiped out the old CentOS install on rossa
and installed CentOS 5.5 on there. The DVDs
are on a spindle in the control room; there
  
  3559   Sun Sep 12 22:36:03 2010 ranaConfigurationComputersrossa notesI found Sanjit's instructions for doing
the Nvidia settings too complicated and so
I followed these instructions from Facebook:
  
  3588   Mon Sep 20 10:33:21 2010 josephbBureaucracyComputersLarry stopped by - GC machine had conflicting IPLarry stopped by today and had to disconnect
the m25 machine (this is the 1st GC machine
on the left as you walk into the control
  
  3595   Wed Sep 22 22:22:12 2010 KojiConfigurationComputersNetgear Network Switch fan broken.Net switch mumbo-jumbo:
Although Rana is going to buy a replacement
for the Netgear Switch for martian, I opened
  
  3597   Thu Sep 23 02:45:30 2010 KojiSummaryComputersnodus gracefully rebootedZach> Nodus seemed to be working fine
again, and I was browsing the elog with no
  
  3598   Thu Sep 23 10:34:20 2010 ranaFrogsComputersnodus gracefully rebootedSVN down
mafalda down 
I am guessing that the NFS file system
  
  3599   Thu Sep 23 11:15:20 2010 KojiFrogsComputersnodus gracefully rebootedsvn is back after starting apache on nodus.
http://lhocds.ligo-wa.caltech.edu:8000/40m/ApacheOnNodus

  
  3601   Thu Sep 23 13:16:57 2010 KojiFrogsComputersnodus gracefully rebootedmafalda is up now.
I found that the cable for mafalda
(the sole red cable) had a broken latch.
  
  3623   Wed Sep 29 18:28:32 2010 yutaUpdateComputersaldabella connects to the wireless networkBackground:
 We need laptops that connect
to the wireless network to use them in the
  
  3627   Thu Sep 30 14:09:33 2010 yutaUpdateComputersmariabella connects to the wireless networkBackground:
 We need laptops that connect
to the wireless network to use them in the
  