  1365   Fri Mar 6 15:23:39 2009 YoichiUpdateLockingLocking distracted by the QPD whitenning problem againBy looking at the time series of DARM signal
at the time of a lock loss, the oscillation
frequency was about 3.5kHz (see the attm1
 lockLoss3.pdflockLoss3-zoom.pdf 
  1366   Fri Mar 6 18:14:58 2009 YoichiUpdateComputersawg not workingStarting from this afternoon, the awg is not
working.
I rebooted FE computers, c0daqawg as well
  
  1369   Sat Mar 7 16:50:25 2009 YoichiUpdateComputersNot even data retrieval workingNow our digital system is really in trouble.
We can't even get data from tp channels.
  
  1370   Sun Mar 8 23:09:26 2009 ranaUpdateComputersNot even data retrieval workingAlthough getting the regular DAQ data works,
we can't get any testpoints.
  
  1371   Sun Mar 8 23:14:52 2009 ranaUpdateComputer Scripts / Programstdsdata doesn't workMatt logged in and rebuilt the
TDS stuff for us on Mafalda in /cvs/cds/caltech/apps/linux/tds_090304.
  
  1373   Mon Mar 9 11:09:33 2009 AlbertoUpdateComputersRe: Not even data retrieval working[quote]Although getting the regular DAQ data
works, we can't get any testpoints.
  
  1374   Mon Mar 9 12:04:18 2009 YoichiUpdateComputersTPs and AWG are backI had to do one more reboot of tpman and daqd
to get the TPs working.
I confirmed the alignment scripts run fine.
  
  1375   Mon Mar 9 14:57:30 2009 KakeruUpdateComputer Scripts / Programstdsdata doesn't workI tested new tdsdata and found it was working
well.
I excited C1:SUS-ITMY_SUSPIT_EXC
 oldtds.pngnewtds.png 
  1376   Mon Mar 9 16:54:52 2009 Kakeru, RanaUpdateComputer Scripts / Programstdsdata doesn't workWe confirmed that new tds(/cvs/cds/caltech/apps/linux/tds_090304/)
works well on linux 64, and replaced it to
/cvs/cds/caltech/apps/linux/tds/
  
  1379   Mon Mar 9 19:33:10 2009 ranaUpdateDMFseisBLRMS in temp conditionThe seisBLRMS has been running on megatron
via an open terminal ssh'd into there from
allegra with matlab running. This
 Untitled.png 
  1380   Mon Mar 9 23:13:22 2009 YoichiUpdateComputer Scripts / Programstdsdata doesn't work


   
        
            
  
  1382   Tue Mar 10 04:55:41 2009 YoichiUpdateLockingLocking: 3.7kHz large oscillationYoichi, Jenne, Alberto,

As I reported on the last Thursday, there
 CARM_DARM_Spectra.pdfPODC_Spe_AOPath_Engaged.pngPODC_Spe_before_PODC_handoff.pngAOGain3.pngAOGain2.png 
  1386   Wed Mar 11 14:51:01 2009 Kakeru, Joe, RobUpdateIOOMC alignmentThis morning, MC alignment was gone and
MC wasn't lock.
We checked old value of pitch, yaw,
  
  1387   Wed Mar 11 16:41:22 2009 steveUpdateMOPAspare NPRO power The spare M126N-1064-700,  sn 5519
of Dec 2006 rebuilt  NPRO's power output
 measured   750mW
  
  1388   Wed Mar 11 16:53:48 2009 YoichiUpdateLockingJunks in around kHzRana, Yoichi

Last night, we tried to find out the source
 MC_F-XARM.pdfold-xarm.pdf 
  1389   Wed Mar 11 21:03:51 2009 Kakeru and KiwamuUpdateIOOPSL angle QPDKakeru and Kiwamu
We placed a QPD on the PSL bench
for PSL angle monitor.
  
  1390   Wed Mar 11 22:57:48 2009 YoichiUpdateLockingCalibrated XARM error signal spectrumI did a rough calibration of the XARM error
spectrum.
See the attached calibrated spectrum.
 XarmErrorSpeCalibrated.pdf 
  1391   Wed Mar 11 23:41:33 2009 Kakeru, YoichiUpdateIOOWFS centering We found the MC reflection was distorted
. And WFC beam went to upward of QPD
We recentered WFC beam and these
  
  1393   Thu Mar 12 02:18:42 2009 YoichiUpdateLockingMC_I spectra (RF_AM)I took several spectra of MC_I signal (see
attm1).
 MC_I_Spe.pngMC_I-Xarm.png 
  1394   Thu Mar 12 15:57:53 2009 YoichiUpdateIOOMC drift is terribleYoichi, Osamu,

Last night's locking work was totally interrupted
 MC_Drift-1.pdfMC_Drift-2.pdf 
  1395   Thu Mar 12 18:44:02 2009 YoichiUpdatePSLMZ alignedThe MC lost the alignment somehow this afternoon.
So I thought it was good time to touch the
MZ because I had to align the MC using the
  
  1396   Thu Mar 12 18:48:37 2009 YoichiUpdateIOOMC aligned but ...After the MZ alignment, I aligned the MC with
the periscope mirrors.
It looked like the MC mis-alignment was mainly
  
  1397   Thu Mar 12 19:11:27 2009 ranaUpdateIOOMC drift is terribleKakeru, Rana, Yoichi

We used the [SIZE=4][COLOR=purple][B]SUS
  
  1398   Thu Mar 12 20:59:04 2009 KakeruUpdateIOOMC drift is terribleAfter Rana went for his dinner, I aligned
periscope to make the MC output 3.2 (Attachment
1).
 MCtrans090312.png 
  1399   Fri Mar 13 05:16:21 2009 YoichiUpdateLockingLocking updateYoichi, Osamu,

With adjustments of the loop gains during
 AOTF2.pngAOTF2-zoom.png 
  1400   Fri Mar 13 19:26:09 2009 YoichiUpdateDMFseisBLRMS compiled I compiled seisBLRMS.
The tricks were the following:
(1) Don't add path in a deployed
  
  1401   Fri Mar 13 20:23:37 2009 YoichiUpdateLSCAO path transfer function with X-arm lockedI measured the AO path transfer function while
the X-arm is locked with the POX PDH signal.
The POX-I signal was already connected to
 AOPath-Xarm.png 
  1402   Fri Mar 13 22:07:14 2009 YoichiUpdateLockingCalibrated XARM error signal spectrumOf course I made a mistake.
I put a pole at 1525Hz whereas it should
have been a zero.
 XarmErrorSpeCalibrated.pdf 
  1403   Sat Mar 14 22:53:12 2009 KakeruUpdateoplevsarm cavity oplev calibrationI finished a calibration of optical levers.

To calibrate oplevs, I locked appropriate
 oplev.pdf 
  1404   Sun Mar 15 21:50:29 2009 Kakeru, Kiwamu, OsamuUpdateComputersSome computers are rebooted We found c1lsc, c1iscex, c1iscey, c1susvme,
c1asc and c1sosvme are dead.
We  turned off all watchdogs
  
  1411   Fri Mar 20 11:01:02 2009 steveUpdatePEMparticle counts are highThe outside particle counts for 0.5 micron
are 3 million this morning at 9am. Low clouds,
foggy condition with low inversion layer.
 particles32d.jpg 
  1413   Fri Mar 20 15:37:58 2009 KakeruUpdateoplevsarm cavity oplev calibration
I calibrated several oplevs with OSEM signal
as a confirmation of my fitting method the
  
  1416   Sun Mar 22 22:47:58 2009 ranaUpdateDMFseisBLRMS compiled but still dyingLooks like seisBLRMS was restarted ~1 AM Friday
morning but only lasted for 5 hours. I just
restarted it on megatron;
  
  1419   Tue Mar 24 03:05:25 2009 YoichiUpdateLockingLocking tonightMC1 issue:
The MC1 seems to be drifting still. I found
it was off from the SUS drift-mon reference
  
  1420   Tue Mar 24 09:04:02 2009 steveUpdateSUS4.8 mag earthquakeSRM, ITMX, ETMX, ITMY and ETMY lost damping
at 4:55am this morning from 4.8 magnitude
earthquake.
  
  1422   Tue Mar 24 13:54:49 2009 JenneUpdateSUSOp Levs CenteredITMX, ITMY, BS, SRM, PRM op levs were all
recentered.  ETM's looked okay enough
to leave as-is. 
  
  1423   Tue Mar 24 19:55:24 2009 JenneUpdateLSCNew PO DC[Rana, Jamie, Jenne]
SPOB DC hasn't been so good lately,
so we installed a new PO DC PD on the PO
  
  1424   Tue Mar 24 23:23:05 2009 ranaUpdateLSCNew PO DCWe also found that the SPOB RF cable was going
through a splitter before going into the
SPOB demod board. The other
  
  1426   Wed Mar 25 04:18:28 2009 YoichiUpdateLockingTuesday LockingAfter the new PO_DC PD was installed, I tweaked
several gains to make the locking scripts
work right.
 AO-Loop-p9.png 
  1427   Wed Mar 25 09:55:45 2009 steveUpdateIOOglitching sensors of MCSUS-MC1_SENSOR_SIDE and SUS-MC2_SENSOR_UL
are glitching
Yesterday's 4.8mag earthquake at
 glitchesofMC.jpg 
  1428   Wed Mar 25 17:22:58 2009 YoichiUpdateIOOMC lock without FSSI made 40k:4k passive filter in a POMONA box
and connected it to IN1 (not TEST IN1) of
the FSS box.
 MC-loop-gain.png 
  1429   Wed Mar 25 20:41:43 2009 JenneUpdateIOOMode Cleaner Servo Board Transfer Functions (to be updated)When all things fail (netgpibdata.py is
giving me weird data.  When I plot the
data it has saved from the 4395A, it's some
 MCwithBoxsmall.JPGMCnoBoxsmall.JPGPomonaBoxforMCsmall.JPG 
  1430   Thu Mar 26 00:45:24 2009 JenneUpdateIOOMode Cleaner Servo Board Transfer Functions (to be updated)


   
        
            
 MCwithandwithoutfilter25Mar2009.pngPomonaBoxMCfilter25Mar2009.pngMCServoData25Mar2009.tar.gz 
  1431   Thu Mar 26 04:01:24 2009 YoichiUpdatePSLFSS Open Loop GainYoichi, Peter, Jenne

Attached is the open loop transfer function
 OpenLoopTF.png 
  1432   Thu Mar 26 04:09:38 2009 YoichiUpdateIOOSingle X arm lock spectra with different MC lock schemesThe attached plots show MC_F, FSS_FAST_F and
XARM IN/OUT spectra with different MC locking
modes.
 XarmSpectra.pdfXarmSpectraZoom.pdf 
  1433   Thu Mar 26 04:27:26 2009 YoichiUpdateLocking3.8kHz peak as a function of the arm powerDuring the power ramp-up, I actuated CARM
using ETMs and measured the transfer functions
to the PO_DC at several arm powers.
 CARM-PODC.pdf 
  1434   Thu Mar 26 09:08:18 2009 KakeruUpdateoplevsarm cavity oplev calibrationI uploaded a document about my oplev calibration.
/cvs/cds/caltech/users/kakeru/oplev_calibration/oplev.pdf
  
  1436   Fri Mar 27 02:50:54 2009 YoichiUpdateLockingDD demodulation phase suspiciousI noticed that the gain of PD6_Q (before the
phase rotation) was 0 whereas PD6_I gain
was 15.
  
  1437   Fri Mar 27 15:05:42 2009 YoichiUpdateIOOMC glitch investigationAttached plots are the result of the
MC1 trend measurement.
See the
attachment #1. The first two plots show the
 MC1_Drift.pdfMC2_Drift.pdf 
  1438   Fri Mar 27 17:52:16 2009 YoichiUpdateIOOMC glitch investigationPer Rob's suggestion, I put the probes
across the output resistors of the bias current
buffers instead of measuring the output voltage
  
ELOG V3.1.3-