40m QIL Cryo_Lab CTN SUS_Lab CAML OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 88 of 355  Not logged in ELOG logo
ID Date Author Typeup Category Subject Text Attachments
  972   Fri Sep 19 09:49:42 2008 YoichiUpdateComputerssvn is oldThe problem below is fixed now.
The cause was .svn/entries and .svn/format
had wrong version number "9" where it had
  
  974   Fri Sep 19 11:48:14 2008 steveUpdateComputers old hubs can make one happyJoseph finds a XIX century bottle neck hub:
CentreCOM 3624TR 10Base-T 
and happily replaces it with Netgear GS724T
 P1020934.jpg 
  975   Mon Sep 22 12:06:58 2008 robUpdateSUSITMY UL OSEM

Last week I found the ITMY UL OSEM dead.
  
  978   Mon Sep 22 18:54:54 2008 JenneUpdatePSLPMC transfer functions with various brick-on-top configurationsAttached below is a graphical summary of different
things that I have tried putting on the PMC
to reduce the noise in the loop.  The motivation
 PMC_OLG_100Hz_to_100kHz.pngPMC_OLG_5kHz_to_30kHz.png 
  979   Mon Sep 22 20:00:35 2008 AlbertoUpdateGeneralABSL: running measurementI'm leaving the X arm locked on the TEm01
mode while a measurement is running. Just
please wait for 40 minute if you need the
  
  981   Mon Sep 22 21:54:05 2008 ranaUpdateASSNew Wiener result with x10 gain in ACCThe 2 attached PDF files show the performance
of the Wiener filter code on 2 hours of data
with a 4000 tap filter on 64 Hz data. All
 f.pdf 
  984   Tue Sep 23 11:17:59 2008 steveUpdatePSLPMC scattering spotThe PMC output side has a new madly scattering
spot at chamfer 2 o'clock position
 rainbow.pngpmcclip.png 
  985   Tue Sep 23 13:25:07 2008 robUpdateLockinga bit betterI've been spending time working on the short
DOF loops (PRC,MICH,SRC) in an attempt to
make the 
  
  987   Wed Sep 24 17:57:04 2008 AlbertoUpdateGeneralABSL: FSS Slow Actuator ControlRana, Alberto

Today when I started working with the PLL
  
  991   Thu Sep 25 10:48:29 2008 YoichiUpdatePSLFSS calibration againI did a calibration of the FSS error signal
again with a different method.
This time, I swept the laser frequency with
 PDTrans.pngPDHsignal.png 
  993   Thu Sep 25 15:24:05 2008 YoichiUpdateIOOMC_F VCO calibrationI calibrated the VCO driving the AOM for the
AO path of the MC feedback.
 VCO_Cal.png 
  995   Fri Sep 26 00:19:54 2008 JenneUpdatePSLFilter-action with the PMCWritten, but not posted on 24Sept2008:

 
  
  996   Fri Sep 26 09:05:47 2008 steveUpdateSUSMC2 damping restoredThe MC2 sus damping was restored.   
  998   Fri Sep 26 16:08:39 2008 robUpdateLockingsome progressThere's been good progress in locking the
last couple of nights.  A lot of time was
wasted before I found that
  
  999   Fri Sep 26 16:13:57 2008 ranaUpdateIOOMC_L / MC_F crossoverWe were trying to understand why the FAST_F
signal had such large excursions (~1V ~ 5
MHz).
 mcx.png 
  1000   Fri Sep 26 18:35:17 2008 JenneUpdatePSLPMC filter is out for tuningThe PMC's new Pomona Box filter is out for
tuning.  I'd like to get the notch right
on the 18.3kHz, rather than being off in
  
  1002   Fri Sep 26 19:18:39 2008 JenneUpdateIOOMC2 is having a bad dayAs Steve mentioned earlier in today's elog,
MC2 keeps ringing up for no clear reason.
 It is definitely only MC2 that is ringing
  
  1004   Mon Sep 29 11:17:14 2008 steveUpdateSAFETYhorizontal viewports are protected with lexanThe four horizontal viewports of arms are
protected 
by 3/8" thick, 8.5" OD Lexan disk of MR10
  
  1007   Mon Sep 29 15:09:36 2008 steveUpdatePSLalmost 4 yrs plot of power & tempsThe water chiller is normally running 1.5
C warmer than the laser head temp.
When control room temp is stable and PEM-count_temp
 3.5y.jpg 
  1008   Mon Sep 29 17:53:33 2008 YoichiUpdatePSLISS updateISS has been saturating easily.
Today I opened the PSL enclosure to inspect
the ISS box. Then I found that the sensor
 IMG_1671.JPG 
  1009   Tue Sep 30 13:43:43 2008 robUpdateLockinglast nightSteady progress again in locking again last
night.  Initial acquisition of DRMI+2ARMs
was working well.
  
  1010   Tue Sep 30 19:50:27 2008 JenneUpdatePSLQuicky Summary - more details laterQuicky summary for now, more details later
tonight / tomorrow morning:
 mcf.png 
  1011   Wed Oct 1 00:24:54 2008 ranaUpdateLockinglast nightI had mistakenly left the MC boost off during
my FAST investigations. The script is now
restored.
  
  1012   Wed Oct 1 02:10:03 2008 ranaUpdateIOOMZ is going badHere's a 2 day trend of the MZ. You can see
that there is something bad with ERR - it
should really be going to zero.
 Untitled.pngUntitled.png 
  1013   Wed Oct 1 02:47:53 2008 ranaUpdatePSLPSL ERR & LODET: Too much offsetLooks like there is an anomolous mixer offset
correlated with the increase in the LO level.
This may be leading to crazy offset locking
 Untitled.png 
  1014   Wed Oct 1 02:54:03 2008 robUpdateLockingbad
Tried the spring-y side tonight with a discouraging
lack of progress.  There were several locks
  
  1017   Wed Oct 1 23:05:14 2008 YoichiUpdatePSLISS RIN spectraStefan, Yoichi

We took relative intensity noise (RIN) spectra
 RIN.pngOPLTF.png 
  1019   Thu Oct 2 02:45:50 2008 robUpdateLockingmarginally betterLocking the DRMI with the +f2 sideband was
marginally better tonight.  I was able to
get it lock stably enough to take transfer
  
  1023   Fri Oct 3 15:09:58 2008 robUpdatePSLFAST/SLOW
Last night during locking, for no apparent
reason (no common mode), the PSL FAST/SLOW
 FASTSLOW.png 
  1024   Fri Oct 3 15:57:05 2008 robUpdateLockinglast night, againLast night was basically a repeat of the night
before--marginally better locking with the
DRMI resonating the +f2
  
  1027   Mon Oct 6 10:00:49 2008 steveUpdateMOPAMOPA_HTEMP is upMonday morning conditions:

The laser head temp is up to 20.5 C
 htup.jpg 
  1030   Tue Oct 7 10:49:29 2008 AlbertoUpdateGeneralDisplaced PhotodiodeThis morning I found that the photodidode
of the PLL in the PSL table was not aligned
to the beam anymore. The PD support was not
  
  1032   Tue Oct 7 21:19:40 2008 YoichiUpdateIOOMC_F calibrated spectrum[COLOR=darkred]I updated the plots because
I did not take into account the double path
AOM effect, which doubles the frequency actuation
 MC_F-spectrum.pngVCO_VoverMC_F.pngPSL_FoverMC_F.png 
  1035   Wed Oct 8 21:26:20 2008 YoichiUpdatePSLAttempt to replace the DC-DC converter (aborted)Rich, Steve, Yoichi

We opened the MOPA box and inspected our
 DCDC.JPGNPRO.JPG 
  1037   Wed Oct 8 23:18:23 2008 YoichiUpdatePSLCorrelation between the Sorensen switching noise and the FSS error signalI took some spectra and coherence function
of the FSS error signal and the +24V Sorensen
power line.
 PowerLineSpe.pngCoherence.png 
  1042   Mon Oct 13 11:32:50 2008 YoixhiUpdatePSLMOPA is in trouble nowSteve, Alberto, Yoichi

A quick update.
 powerdrop.png 
  1044   Mon Oct 13 13:56:03 2008 YoichiUpdatePSLMOPA is not that much in trouble nowThe problem was found to be all to do with
the shutter.
The shutter started to work again, after
  
  1045   Mon Oct 13 18:59:39 2008 YoichiUpdatePSLNPRO EMI and FSS error signal correlationI made a simple loop antenna to measure the
electro-magnetic inteference (EMI) around
the master oscillator NPRO.
 IMG_1692.JPGSpectrum.pngSpectrumFar.pngCoherence.png 
  1047   Tue Oct 14 19:18:18 2008 YoichiUpdateComputersBootFestRana, Yoichi

Most of the FE computers failed around the
  
  1049   Wed Oct 15 17:40:50 2008 ranaUpdatePSLPMC Offset adjustedI set the PMC servo input offset: closed the
MOPA shutter, zeroed the mixer output with
the offset slider, 
  
  1051   Thu Oct 16 09:44:49 2008 YoichiUpdatePSLBad cable for FSSYesterday arount 1:30PM, we lost the LO signal
for the FSS.
I found it was caused by a bad cable connecting
  
  1056   Fri Oct 17 21:41:09 2008 YoichiUpdateComputer Scripts / Programsburtwb missing on Solaris but installed on linux64c1lsc stalled this evening, so I powercycled
it.
After that, I tried to lock arms to confirm
  
  1057   Mon Oct 20 09:45:56 2008 steveUpdatePEMPSL HEPA onThe PSL HEPA filter was turned on.
It should be running all times.
The 0.5 micron particle count is up to 20,000
  
  1058   Mon Oct 20 12:18:38 2008 AlanUpdateComputer Scripts / Programsburtwb missing on Solaris but installed on linux64[quote]c1lsc stalled this evening, so I powercycled
it.
After that, I tried to lock arms to confirm
  
  1062   Tue Oct 21 16:14:42 2008 steveUpdateGeneraldivergence of He Ne 1035PThe ITM oplevs laser diodes are noisy.
They will be replaced by JDS 1035P
SN T8093307 was measured with the beamscanner.
 1035p_divergence.png 
  1063   Tue Oct 21 16:17:45 2008 YoichiUpdatePSLAD797 Oscillation in the FSS boardI checked each op-amp's output in the FSS
board to see if any indication of slew-rate
saturation can be found.
  
  1067   Wed Oct 22 12:37:47 2008 josephbUpdateComputersNetwork spreadsheetAttached in open office format as well as
excel format is spreadsheet containing all
the devices with IP addresses at the 40m.
 40m_network_10-15-08.ods40m_network_10-15-08.xls 
  1069   Wed Oct 22 17:48:58 2008 YoichiUpdateGeneralLenses for focusing the optical lever laser (Re:divergence of He Ne 1035P)Steve had difficulty in finding lenses for
focusing the HeNe laser for the ITM op-lev.
Following his measurement of the beam divergence,
 BeamProfile.pngBeamPropagation.pngBeamPropagation.zip 
  1072   Thu Oct 23 15:27:19 2008 AlbertoUpdateGeneralAbs lengthHere are the measurements I've got yesterday.
The plot shows the transmitted power after
the X arm while sweeping the frequency of
 TRX_aplot_03_04_05_together.png 
  1073   Thu Oct 23 18:23:47 2008 AlbertoUpdateGeneralAbs length[quote]Here are the measurements I've got
yesterday. The plot shows the transmitted
power after the X arm while sweeping the
 TRX_plot_06_07_08_together.png 
ELOG V3.1.3-