  1173   Wed Dec 3 20:36:07 2008 Jenne, RanaUpdatePEMComparing Wiener subtraction with different seismometersThe Ranger has now been moved over to sit
underneath the MC2 tank (it was previously
close to the PSL rack). It
 d.pdfsco.pngfly.pdf 
  1174   Thu Dec 4 13:49:39 2008 JenneUpdatePEMMore of: Comparing Wiener subtraction using different sensorsHere is another version of the same type plot
I put in the elog yesterday.  This plot is
looking at the 7200 seconds after 04Dec2008
 Dec042008_c1wino_seisCombos.png 
  1219   Fri Jan 9 09:14:17 2009 steveUpdatePEMifo is recovered after eqThere is no obvious damage from last night
earth quake.
All sus dampings were turned on, MC locked
 eq4.5sb.jpg 
  1337   Wed Feb 25 11:48:02 2009 JenneUpdatePEMWiener filtering update - work on filtering some S5 DARM_CTRL dataQuick update on my wiener filtering status:
Joe has been helping me get on the
GRID, so I now have  a grid certificate,
 h1_DARM_64s_4seis_25Feb09.pngh1_DARM_3600s_4seis_25Feb09.png 
  1347   Tue Mar 3 08:44:31 2009 steveUpdatePEMair cond. maintenance todayIFO room 104 air conditions will be shut
down for maintenance today.
This
should be finished by noon.
The
  
  1411   Fri Mar 20 11:01:02 2009 steveUpdatePEMparticle counts are highThe outside particle counts for 0.5 micron
are 3 million this morning at 9am. Low clouds,
foggy condition with low inversion layer.
 particles32d.jpg 
  1447   Tue Mar 31 09:42:32 2009 steveUpdatePEMETMY sus damping restored againThe Caltech gasoline storage tank is being
upgraded.
They are jack hammering and digging
  
  1453   Fri Apr 3 14:52:38 2009 JenneOmnistructurePEMGuralp is finally back!After many, many "it'll be there in
2 weeks" from the Guralp people, our
seismometer is finally back!
  
  1455   Mon Apr 6 19:09:15 2009 JenneUpdatePEMOld Guralp is hooked back up to the ADCOld Guralp is hooked back up, the new one
is sitting next to it, disconnected for now.
  
  1528   Tue Apr 28 12:55:57 2009 CarynDAQPEMUnplugged Guralp channelsFor the purpose of testing out the temperature
sensors, I stole the PEM-SEIS_MC1X,Y,Z channels.
I unplugged Guralp NS1b, Guralp Vert1b,
  
  1540   Sat May 2 16:34:31 2009 carynDAQPEMGuralp channels plugged back in I plugged the Guralp cables back into the
PEM ADCU
      
  
  1546   Tue May 5 09:22:46 2009 carynUpdatePEMzerosFor several of the channels on the PEM
ADCU, zeros are occuring at the same time.
Does anyone know why that might happen or
 zerotest2.pngzerotest.png 
  1566   Fri May 8 16:03:31 2009 JenneUpdatePEMUpdate on Jenne's Filtering StuffTo include the plots that I've been working
on in some form other than on my computer,
here they are:
 H1S5OneMonthWienerCompBLACK.pngH1S5BandLimitedTimePlot.png 
  1571   Sun May 10 13:34:32 2009 carynUpdatePEMUnplugged Guralp channelsI unplugged Guralp EW1b and Guralp Vert1b
and plugged in temp sensors temporarily.
Guralp NS1b is still plugged in.
  
  1597   Mon May 18 01:54:35 2009 ranaUpdatePEMUnplugged Guralp channelsTo see if Caryn's data dropouts were happening,
I looked at a trend of all of our temperature
channels. Looks OK now.
 Untitled.png 
  1599   Mon May 18 10:06:56 2009 carynUpdatePEMTemp sensor[quote]To see if Caryn's data dropouts were
happening, I looked at a trend of all of
our temperature channels. Looks OK now.
 datadropout.pngcoolerpic1.jpgcoolerpic2.jpg 
  1600   Mon May 18 15:31:11 2009 ranaUpdatePEMTemp sensor[quote]Picture of cooler for posterity is
attached[/quote]
 Untitled.png 
  1606   Tue May 19 15:54:29 2009 JenneUpdatePEMMore Plots for the S5 H1:DARM Wiener Filtering....Even more plots for the Wiener filtering!
We have a set of spectrograms, which
show (in color) the amplitude spectrum, at
 6x 
  1612   Wed May 20 09:55:18 2009 steveUpdatePEMoplev servos turned offAll oplevs servos turned off to protect
our suspentions from vibration due to drilling
and pounding in CES high bay area.
 ACpart6m.jpg 
  1624   Mon May 25 21:31:47 2009 carynUpdatePEMplugged in Guralp channelsGuralp Vert1b and Guralp EW1b are plugged
back in to PEM ADCU #10 and #12 respectively.
Guralp NS1b remains plugged in. So, 
  
  1647   Wed Jun 3 11:28:01 2009 carynUpdatePEMUnplugged Guralp channels     
  1648   Wed Jun 3 12:31:13 2009 carynUpdatePEMplugged in guralp channels    
  1653   Thu Jun 4 23:39:23 2009 peteUpdatePEM5 days, 20 days of accelerometersLooks like yesterday was particularly noisy. 
It's unclear to me why diurnal variation
much more visible in MC1_Y, and why the floor
 acc_5day.pngacc_20days.png 
  1665   Wed Jun 10 09:06:12 2009 steveUpdatePEMparticle counts and turbulanceI moved the mobile HEPA filter from ITMX's
north door to ITMX-ISCT and covered it up
with a merostate tent to accommodate the
 parturbulnc.jpg 
  1692   Tue Jun 23 23:14:36 2009 ClaraConfigurationPEMAccelerometers relocatedBoth accelerometers have been moved in
an attempt to optimize their positions. The
MC1 accelerometer was moved from one green
  
  1696   Wed Jun 24 12:04:00 2009 ClaraUpdatePEMaccelerometer clarificationWhen I said "MC1/MC2 accelerometers,"
I meant the entire three-axis accelerometer
set at each point.
  
  1698   Wed Jun 24 12:09:24 2009 ClaraUpdatePEMWeek 1(ish)I spent the week reading up on filter algorithm
theory, particularly Wiener filtering. I
have also learned how to get data from specific
  
  1703   Thu Jun 25 21:00:30 2009 ClaraUpdatePEMMC1 Accelerator set moved again; new XLR cablesI moved the MC1 set of accelerators. Might
have bumped things. If things aren't working,
look around the MC1 chamber.
  
  1704   Fri Jun 26 15:22:28 2009 ClaraUpdatePEMXLR cables tested and labeledWe now have two 80-foot, female-to-female
XLR cables for our pretty new microphones,
one yellow and one purple. They have been
 NC3FXX-EMC.pdfCat11_p35.pdf 
  1705   Fri Jun 26 18:00:36 2009 JenneUpdatePEMNew PEM channels for the fancy-pants new microphones[ Jenne, Clara ]
We made new channels for the microphones
which came in this week, by editing C1ADCU_PEM.ini
  
  1707   Sat Jun 27 02:48:09 2009 ClaraUpdatePEMI moved accelerometers and made some pretty picturesI have been working on finding the best
spots to put the accelerometer sets in order
to best subtract out noise (seismometers
 6x 
  1708   Sat Jun 27 03:16:16 2009 ClaraUpdatePEMExciting microphone things!So, I'm double-posting, but I figured the
last post was long enough as it was, and
this is about something different. After
 mic_voltage_out.pngvoltage_dividers.pngvoltage_divider_sketch.png 
  1713   Thu Jul 2 05:27:12 2009 ClaraUpdatePEMVoltage Divider OopsI tested the voltage dividers and was getting
up to about 3V. I retested the mic w/o the
voltage divider in place, and, lo and behold,
 voltage_divider_diagram.png 
  1714   Thu Jul 2 06:31:35 2009 ClaraUpdatePEMFirst mic in place and connectedI clamped Bonnie (microphone) to the top
of a chamber near the vertex of the arms
and placed Clyde (pre-amp) on the table right
 bonnieandclyde.JPG 
  1715   Thu Jul 2 16:45:06 2009 ClaraUpdatePEMBonnie and Clyde are officially in operation! (Butch Cassidy and the Sundance Kid are in temp position)I hooked up Bonnie and Clyde last night
and tested it today. First I tried some loud
noises to make sure I could identify them
 bonnie_test_marked.pngbonnie_test2_marked.pngbonniebutch_2sbeat_marked.png 
  1723   Wed Jul 8 12:36:15 2009 ClaraUpdatePEMCoherences and thingsAfter setting up the microphones last week,
I modified the Wiener filtering programs
so as to include the microphone signals.
 7x 
  1726   Wed Jul 8 19:42:37 2009 ClaraUpdatePEMBonnie moved to PSL, getting some coherence with the PMC_ERR channelIn her position overlooking whichever table
it is that is next to the PSL, Bonnie drummed
up some decent coherence with the PSL-PMC_ERR
 DSC_0567.JPGbonnie2_pmcerr.pdfbonnie_PSL.pdf 
  1727   Thu Jul 9 02:18:09 2009 ranaUpdatePEMBonnie moved to PSL, getting some coherence with the PMC_ERR channelMy guess is that we need a different acoustic
strategy. The microphones are mainly for
high frequencies, 
  
  1728   Thu Jul 9 19:05:32 2009 ClaraUpdatePEMmore mic position changes; mics not picking up high frequenciesBonnie has been strung up on bungees in
the PSL so that her position/orientation
can be adjusted however we like. She is now
 6x 
  1729   Thu Jul 9 19:24:50 2009 ranaUpdatePEMmore mic position changes; mics not picking up high frequenciesMight be the insidious 850 Hz AA filters in
the black AA box which precedes the ADC.
  
  1744   Tue Jul 14 16:31:46 2009 ClaraUpdatePEMFrequency Response of Microphone (Bonnie)So, I actually took these measurements
last week, but I didn't get around to making
nice plots and things until now. I figured
 Bonnie_fres_regplot.pdfBonnie_fres_logplot.pdf 
  1757   Thu Jul 16 10:52:58 2009 ClaraUpdatePEMSingle Channel TRS-RNC CableI made and tested a female-to-female TRS(audio)-RNC
cable. It only has a single channel, so it
won't work for stereo speakers or anything,
  
  1760   Fri Jul 17 18:04:54 2009 ClaraUpdatePEMGuralp Box FailI've been trying for most of the week to
get noise measurements on the output of the
Guralp box as well as scross the AD640 chip.
 VERT2_missing_resistors.pngresistors_diagram.pngresistors_board.png 
  1761   Sat Jul 18 19:49:48 2009 ranaUpdatePEMGuralp Box FailThat's terrible: R5 & R8 should definitely
be 100 Ohm and not 100kOhm. 100k would make
it a noise disaster. They should also be
 Picture_1.pngPicture_2.pngAD620.pdf 
  1765   Mon Jul 20 17:06:29 2009 JenneUpdatePEMGuralp Box Fail[quote]That's terrible: R5 & R8 should definitely
be 100 Ohm and not 100kOhm. 100k would make
it a noise disaster. They should also be
 AD620noise_BenAbbott.pdf 
  1767   Tue Jul 21 13:55:08 2009 ClaraUpdatePEMGuralp Box Success!There managed to be just enough 100 kOhm
resistors to stuff all the "2"
channels (VERT2, N/S2, E/W2) with the fancy
  
  1800   Tue Jul 28 16:03:14 2009 ClaraUpdatePEMGuralp Seismometer cable pin diagramI mapped out the corresponding pins on
both ends of the Guralp seismometer cable.
Here is the diagram:
 guralp_pin_diagram.png 
  1806   Wed Jul 29 13:15:35 2009 ClaraUpdatePEMDents = Bad??I was in the lab last night accelerometerizing
and noticed some dents on the tubes that
stick out horizontally from the MC2 optical
 small_dent.pngbig_dent1.pngbig_dent2.png 
  1808   Wed Jul 29 14:56:44 2009 JenneUpdatePEMMiniEarthquakes due to constructionThe construction people next door seem
to be getting pretty excited about pounding
things lately.  At my desk the floor
  
  1811   Wed Jul 29 19:46:04 2009 rana, albertoUpdatePEMDents = Bad??[B]It looks like the MC2 chamber and/or stack
has been jarred and shifted. Please be careful
and use much less force and speed around
  