40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 87 of 341  Not logged in ELOG logo
ID Date Author Typeup Category Subject Text Attachments
  1298   Thu Feb 12 17:43:33 2009 YoichiUpdateLSCSRC strangeness solvedI found the problem with the DRMI lock I had
last night was caused by the zero gain in
the PD11_I filter.
  
  1300   Fri Feb 13 08:38:03 2009 steveUpdateIOOMC2 damping restored    
  1301   Fri Feb 13 13:35:38 2009 YoichiUpdateLSCLocking statusYoichi, Jenne, Alberto, Rob

Last night, the locking proceeded until the
  
  1304   Sat Feb 14 16:53:26 2009 robUpdateLSCLocking status[quote]Yoichi, Jenne, Alberto, Rob

Last night, the locking proceeded until the
  
  1305   Sun Feb 15 09:35:00 2009 YoichiUpdateLSCLocking status[quote]
I found a '$<' in the offloadMCF script.
 I don't know precisely what that construct
  
  1306   Sun Feb 15 15:53:21 2009 RobUpdateLSCLocking status[quote]
  I didn't get a chance to do much testing
since the sus controller (susvme1) went nuts.
  
  1307   Mon Feb 16 00:43:46 2009 ranaUpdateComputersmedm directory wiped on nodus[COLOR=red][B]I accidentally did an 'rm -rf'
on the medm directory in nodus[/B][/COLOR],
instead of on my laptop as was intended.
  
  1308   Mon Feb 16 10:18:13 2009 AlbertoUpdateLSCFE system rebooted[quote][quote]
  I didn't get a chance to do much testing
since the sus controller (susvme1) went nuts.
  
  1309   Mon Feb 16 14:12:21 2009 YoichiUpdateLSCFE system rebooted[quote]
I can't restart the MC autolocker on c1susvme2
because it doesn't let me ssh in. I tried
  
  1310   Mon Feb 16 15:54:07 2009 YoichiUpdateComputersmedm directory wiped on nodus[quote][COLOR=red][B]I accidentally did an
'rm -rf' on the medm directory in nodus[/B][/COLOR],
instead of on my laptop as was intended.
  
  1311   Mon Feb 16 16:26:29 2009 robUpdateComputersmedm directory wiped on nodus[quote][quote][COLOR=red][B]I accidentally
did an 'rm -rf' on the medm directory in
nodus[/B][/COLOR], instead of on my laptop
  
  1313   Mon Feb 16 21:49:06 2009 Kakeru, RanaUpdateIOOWFSWe centerd the input of WFS QPD.   
  1315   Mon Feb 16 23:09:52 2009 ranaUpdateElectronicsMC Servo Board offset gone bad!The attached plot shows that someone broke
the MC_SUM_MON channel around 10:30 AM this
past Wednesday the 11th. This is the EPICS
 mcoff.png 
  1316   Tue Feb 17 05:20:11 2009 YoichiUpdateLSCLockingSince we excluded *.snap and *.req files from
the svn control in the medm directory and
these were not restored by the svn co, the
  
  1317   Wed Feb 18 03:17:40 2009 YoichiUpdateLSCLocking Yoichi, Kakeru,

Last night, the cm_step script failed at
  
  1318   Wed Feb 18 03:25:25 2009 YoichiUpdateComputersmedm directory backI restored the medm directory from the backup
on the tape.
The directory had an svn property svn:ignore
  
  1321   Wed Feb 18 21:03:22 2009 ranaUpdateCamerasETMY Camera work not elogged!The control room video is showing us a
false ETMY image. Who worked on the ETMY
camera or video today??!!
  
  1322   Wed Feb 18 21:10:21 2009 ranaUpdateIOOMC Drumhead mode lost againIn early December, Caryn and I noticed that
the MC Drumhead mode was visible at the Qmon
point of
  
  1323   Thu Feb 19 04:16:17 2009 YoichiUpdateLSCLocking statusRob, Yoichi

We checked the CM-MC cross over just before
  
  1324   Thu Feb 19 11:51:56 2009 steveUpdateMOPAHTEMP variation is too muchThe C1:PSL-MOPA_HTEMP variation is more
than 0.5 C daily
Normally this
temp stays well within 0.1 C
This
 80dhtemp.jpg 
  1325   Thu Feb 19 16:29:43 2009 YoichiUpdateComputersMartian wireless router badThe Martian wireless router is dead.
I rebooted it several times, but it hangs
up in a minute.
  
  1326   Thu Feb 19 22:40:33 2009 KiwamuUpdateElectronicsPSL angle QPDI checked a broken QPD, which was placed
for PSL angle monitor, and finally I cocluded
one segment of the quadrant diode was
  
  1327   Thu Feb 19 23:50:31 2009 peteUpdateLockingaligned pd's on AP tableYoichi, Peter
While continuing our efforts to lock,
we noticed the procedure failed at a point
  
  1328   Fri Feb 20 01:54:18 2009 KakeruUpdateComputer Scripts / Programstdsdata might have a bugI found a strange jump of value in my data
taken with tdsdata.
I couldn't find same jump in
 jumped_data.png 
  1329   Fri Feb 20 03:52:23 2009 YoichiUpdateLockingLocking TonightYoichi, Peter

Tonight, we had a problem with the DD hand
  
  1330   Fri Feb 20 19:31:16 2009 YoichiUpdateLSCMICH low gain problemLast night, we found that MICH UGF was too
low. Even after re-aligning the PDs, it was
still too low.
  
  1334   Tue Feb 24 02:23:40 2009 YoichiUpdateLockingLocking - MC board badRob, Yoichi, Alberto, Kiwamu, Kakeru

We found that the OMC alignment feedback
  
  1335   Tue Feb 24 18:42:15 2009 peteUpdateLockingmc board repairPeter, Yoichi
Last night:
  
  1336   Wed Feb 25 03:10:24 2009 YoichiUpdateLockingLocking statusRob, Yoichi, Kakeru, Kiwamu

Tonight, CARM -> MCL hand off was not stable.
  
  1337   Wed Feb 25 11:48:02 2009 JenneUpdatePEMWiener filtering update - work on filtering some S5 DARM_CTRL dataQuick update on my wiener filtering status:
Joe has been helping me get on the
GRID, so I now have  a grid certificate,
 h1_DARM_64s_4seis_25Feb09.pngh1_DARM_3600s_4seis_25Feb09.png 
  1339   Thu Feb 26 01:24:44 2009 YoichiUpdateComputersMartian wireless is backToday, a new wireless router arrived.
I configured and installed it. Now the martian
wireless network is back.
  
  1341   Thu Feb 26 19:59:23 2009 YoichiUpdateLockingDaytime lockingOsamu, Yoichi

We tried locking today from about 2PM.
 CM1.pngCM2.pngCM3.png 
  1343   Fri Feb 27 13:49:19 2009 robUpdateLockingthurs nightCould not get past arm power of ~11 or
so.  I was suspicious of the transmon
high-gain/low-gain PD handover, so I ran
  
  1344   Mon Mar 2 03:57:44 2009 YoichiUpdateLockingSunday night lockingTonight's locking started with a boot fest
of the FE computers which were all red when
I came in.
  
  1346   Mon Mar 2 21:16:32 2009 YoichiUpdateLockingLow-gain High-gain PD switching may not be working wellOsamu, Yoichi

This afternoon, I run the locking script
  
  1347   Tue Mar 3 08:44:31 2009 steveUpdatePEMair cond. maintenance todayIFO room 104 air conditions will be shut
down for maintenance today.
This
should be finished by noon.
The
  
  1348   Tue Mar 3 10:39:07 2009 AlbertoUpdateLSCc1lsc discontinued functioningThe c1lsc has been unstable since last
night. Its status on the DAQ screen was oscillating
from green to red every minute.
  
  1350   Tue Mar 3 19:26:44 2009 YoichiUpdateLockingLow-gain High-gain PD switching may not be working wellI checked the switching of the QPDX from high
gain to low gain.
Switching happens as expected, but the low
  
  1351   Tue Mar 3 23:59:26 2009 YoichiUpdateLockingLow-gain High-gain PD switching may not be working well[quote]I checked the switching of the QPDX
from high gain to low gain.
Switching happens as expected, but the low
  
  1352   Wed Mar 4 03:37:51 2009 YoichiUpdateLockingLow-gain High-gain PD switching may not be working well[quote]
This sounds like the QPD whitening gain sliders
may be stuck.  The slider twiddling script
  
  1353   Wed Mar 4 03:50:17 2009 YoichiUpdateLockingStill won't go above arm power 10Yoichi, Kentaro

The IFO still loses lock at around arm power
 lockLoss1.pnglockLoss2.pnglockLoss3.png 
  1354   Wed Mar 4 12:38:07 2009 AlbertoUpdateComputer Scripts / Programs3f locking simulationsI simulated the REFL signals demodulated
at the differential frequencies of the sidebands
(f2-f1), at their summed frequencies (f2+f1).
 23_3f_40mOld_DDplots.pdf59_3f40m_Upgrade_DDplots.pdf20_3f_AdvL_DDplots.pdf 
  1355   Wed Mar 4 17:20:04 2009 josephbUpdateCamerasCamera code upgradesI've updated the digital camera python
code as well as changed the network topology.
At the moment, both cameras are connected
  
  1358   Thu Mar 5 00:06:32 2009 Kakeru, RanaUpdateIOOWFS centeringWe found that the MC REFL image was no longer
round and that the MCWFS DC quadrant spots
were mostly
 IOO_graph.jpg 
  1359   Thu Mar 5 01:09:29 2009 rana, albertoUpdateDMFstill not workingWe tried to run DMF on mafalda, but it didn't
work. I tried to compile it using Rob's elog
instructions.
  
  1361   Thu Mar 5 05:07:09 2009 YoichiUpdateLockingWednesday night lockingTonight, I was having a problem with the PO_DC
hand-off.
It fails most of the time.
 lockLoss5.pnglockLoss5-zoom.png 
  1364   Fri Mar 6 05:44:14 2009 YoichiUpdateLockingLocking distracted by the QPD whitenning problem againTonight, I was able to ramp up the arm power
to around 20. Then the DARM loop started
to oscillate and the IFO lost lock in a few
  
  1365   Fri Mar 6 15:23:39 2009 YoichiUpdateLockingLocking distracted by the QPD whitenning problem againBy looking at the time series of DARM signal
at the time of a lock loss, the oscillation
frequency was about 3.5kHz (see the attm1
 lockLoss3.pdflockLoss3-zoom.pdf 
  1366   Fri Mar 6 18:14:58 2009 YoichiUpdateComputersawg not workingStarting from this afternoon, the awg is not
working.
I rebooted FE computers, c0daqawg as well
  
  1369   Sat Mar 7 16:50:25 2009 YoichiUpdateComputersNot even data retrieval workingNow our digital system is really in trouble.
We can't even get data from tp channels.
  
ELOG V3.1.3-