  17049   Sat Jul 30 10:38:12 2022 AnchalUpdatePSLFSSSlow/MCAutolocker issue (docker)The FSSSlow script was not properly documented
and it was not working, so I had to use one
that I knew worked from CTN. This scripts
  
  17050   Sat Jul 30 12:48:18 2022 KojiUpdatePSLFSSSlow/MCAutolocker issue (docker)> it only starts working when C1:IOO-MC_LOCK
is 1 and C1:PSL-FSS_SLOWLOOP is 1.

- OK. Your new MCAutolocker does
  
  17057   Thu Aug 4 11:28:22 2022 AnchalUpdatePSLFSSSlow/MCAutolocker issue (docker)Added C1:IOO-MC_LOCK
to ALConfigMC.yml which solved the isse
with FSS Slow. We should tune the FSS Slow
  
  17065   Mon Aug 8 14:47:10 2022 ranaUpdatePSLFSSSlow/MCAutolocker issue (docker)can't we just go back to the old python
script that was working for many years, and
tested? I imagine that as soon as someone
  
  17201   Thu Oct 20 14:13:42 2022 yutaSummaryPSLPMC and IMC sideband frequencies measuredI measured the sideband frequencies for
PMC and IMC lock (to use it for Mariner PMC
and IMC design).
 IMC.JPGPMC.JPG 
  17271   Wed Nov 16 11:56:21 2022 RadhikaUpdatePSLPMC input beam aligned again, IMC [Yuta, JC, Radhika]

PMC input beam was aligned again,
bringing transmission from 0.70 to ~0.75.
 Screen_Shot_2022-11-16_at_12.04.18_PM.png 
  17290   Mon Nov 21 09:13:31 2022 JCUpdatePSLPMC input beam aligned again, IMC [JC, Paco]

I attempted to align PMC Beam from
a transmission of 0.72. I failed to do so
  
  17297   Tue Nov 22 08:56:27 2022 JCUpdatePSLPMC input beam alignment[Paco, Anchal, JC]

C1:PSL-PMC_PMCTRANSPD ~ 0.715 this
morning, this was increased to ~0.730. There
 Screenshot_from_2022-11-22_08-58-45.png 
  17   Fri Oct 26 09:10:17 2007 steveRoutinePEMPEM &PSL trendThe fires are out, lab particle counts are
up.
Psl HEPAs are at 100% and mobel HEPAs are
 counts&psl.jpg5dcounts.jpg 
  83   Thu Nov 8 11:40:21 2007 steveUpdatePEMparticle counts are upI turned up the psl HEPA filter to 100%
This 4 days plot shows why
 pslhepaon.jpg 
  114   Mon Nov 19 14:19:25 2007 steveOmnistructurePEMjackhammerThe construction personal successfully jackhemmered
a fence around the "Drever's parking slot"
There is no parking space available close
 jackhammer.jpgjackhammer2.jpg 
  151   Fri Nov 30 20:17:26 2007 AndreyConfigurationPEMAccelerometers and alum.plates for themAll 6 accelerometers which were located near
the ITMX are turned off and disconnected
from the power cords.
 Scheme_Aluminum_Piece-inches.pdf 
  152   Fri Nov 30 21:27:24 2007 ranaDAQPEMweather / stacis / c1pem1I was trying to add some Seis BLRMS channels
to the c1pem1 processor so that we could
have DMT trends.
  
  161   Mon Dec 3 19:44:58 2007 Accelerometers on new mountsConfigurationPEMAndrey
I (Andrey) continued today working with new
accelerometer mounting. (see entry #151 about
 DSC_0194.JPGDSC_0195.JPGDSC_0196.JPG 
  172   Wed Dec 5 23:19:03 2007 AndreyConfigurationPEMAccelerometers are turned on
All accelerometers have been turned on, as
Alan asked during Wednesday meeting.
 7x 
  189   Wed Dec 12 22:24:48 2007 tobinFrogsPEMweather stationI poked at the weather station briefly this
evening.
  
  200   Wed Dec 19 11:31:01 2007 steveOmnistructurePEMaircond filter maintenanceJeff is working on all air condiontion units
of the 40m lab
This we do every six months.
 acfilters6m.jpg 
  204   Wed Dec 19 20:28:27 2007 AndreyDAQPEMNames for all 6 accelerometers have been changed
I eventually [COLOR=red]changed the names
for all 6 accelerometers[/COLOR] (see my
  
  255   Wed Jan 23 11:41:06 2008 steveUpdatePEMsulfur smell in 40mLed - acid car batteries were overcharged
in the machine shop next door
and sulfuric acid smell is coming over to
  
  258   Thu Jan 24 11:52:56 2008 steveUpdatePEMthe mud is cleaned up & MOPA shutter is openedSafety glasses are required again!

I have just opened the mopa shutter.
  
  264   Fri Jan 25 09:22:21 2008 steveUpdatePEMburned toast award goes toDYM for  collaborating with the enemy. 

In order to minimize the number of ants visiting
  
  283   Mon Jan 28 19:35:55 2008 ranaSummaryPEMAccelerometer and Seismometer Coherences[FONT=Arial][COLOR=purple]The attached PDF
shows that there is some strange behavior
at low frequencies.[/COLOR][/FONT]
 Acc.pdf 
  295   Sun Feb 3 05:02:41 2008 ranaUpdatePEMSeism 4 day   Screenshot.png 
  298   Tue Feb 5 17:39:05 2008 jweinerConfigurationPEMPEM-AS_MIC taken down from AS table, will put in PSL enclosure soonI took down the microphone that Andrey hung
above the AS table his first week in lab.
I want to hang the microphone above the PMC
  
  299   Wed Feb 6 09:17:31 2008 steveUpdatePEMIST building construction continouesThe bulldosers at work  seismic8d.jpgseisioo.jpg 
  303   Fri Feb 8 17:55:53 2008 joshConfigurationPEMPEM-AS_MIC now in PSL enclosureI have moved the microphone to the PSL enclosure,
hanging near the south (Y) side from a support
rod for the overhanging storage area so that
  
  308   Mon Feb 11 14:24:19 2008 steveUpdatePEMmore earthquakesITMX and ITMY sus damping restored after Baja
earthquake 5.1 mag at 10:29 this morning.
 eqfeb11.jpg 
  324   Tue Feb 19 18:28:41 2008 JohnUpdatePEMMore seismic in Baja CaliforniaSteve spotted more activity from the same
quake. 
  
  330   Fri Feb 22 02:51:20 2008 AndreyUpdatePEMAccelerometer ITMX seems to be broken
As people probably know,
 Accelerom-EYMX-Feb22.jpgAccelerom-ITMX-Feb22.jpg 
  336   Fri Feb 22 15:16:33 2008 AndreyUpdatePEMITMX Accelerometer is NOT broken
As I wrote in message 330, there was a bad
signal from ITMX accelerometer. I have found
 Accelerom-ITMX-Feb23.jpgAccelerom-ETMX-Feb23.jpg 
  363   Fri Mar 7 00:47:54 2008 ranaConfigurationPEMRanger SS-1Yesterday evening around 7:30 PM, I changed
the Ranger seismometer from a 
vertical to a horizontal seismometer. To
 ss1.pdf 
  368   Tue Mar 11 23:14:01 2008 ranaConfigurationPEMAccelerometer and Seismometer movementsSteve and Matt moved the accelerometers and
seismometers today. 
The accelerometers are now placed around
 Acc.pdf 
  369   Wed Mar 12 00:36:52 2008 ranaConfigurationPEMAccelerometer and Seismometer movementsI used the MISO FIR Wiener matlab code to
see how well we might do in principle.
 finished.pdf 
  370   Wed Mar 12 00:40:35 2008 ranaConfigurationPEMAccelerometer and Seismometer movementsSame as above but with 2048 taps and a 128
Hz sample rate. Does much better at the 16
Hz bounce mode.
 mc2048-128.pdf 
  371   Wed Mar 12 00:47:26 2008 ranaConfigurationPEMAccelerometer and Seismometer movementsAnd this is a [COLOR=blue]cool snapshot[/COLOR]
showing how this operation used [B][COLOR=red]16
cores[/COLOR][/B] on [SIZE=5][B][COLOR=purple]menkar
 Screenshot.png 
  384   Mon Mar 17 18:30:48 2008 mevansConfigurationPEMAdaptive FilteringIt seems that adaptive filtering can achieve
results similar to those of the MISO FIR
Wiener (entry 369).  The adaptive code simulates
 mcacc_adaptive.png 
  391   Fri Mar 21 23:15:11 2008 ranaConfigurationPEMRanger SS-1: New SetupThe Ranger seismometer has been in a bad state.
Its output had been sent into a SR560 without
any termination.
  
  418   Tue Apr 8 09:08:54 2008 steveConfigurationPEMweather station disconnectedWe can not leave cables in the walkways and
go on vacation.
I disconnected the weather station from the
 toast.jpg 
  420   Wed Apr 16 09:47:35 2008 AndreySummaryPEMWeather Station The weather station is functional again.

The long ethernet Cat5 cable connecting 'WeatherLink'
 Weather-FullData_3hrs.pngWeather_Trend_15hrs.png 
  424   Thu Apr 17 20:17:37 2008 AndreyUpdatePEMTwo issues with our weather station
I encountered two difficulties working with
the "Weather Station".
  
  427   Fri Apr 18 16:48:13 2008 AndreyUpdatePEMRain collector of weather station
Today the rain collector of our weather station
was cleaned. As a result, we checked that
 DSC_0520--before.JPGDSC_0537--after.JPG 
  445   Thu Apr 24 23:27:48 2008 ranaUpdatePEMacoustic noise in MC_FI looked at the [COLOR=darkblue][FONT=Comic
Sans MS][SIZE=3]coherence between the Microphone
in the PSL (PEM-AS_MIC) and the MC_F[/SIZE][/FONT][/COLOR]
  
  448   Fri Apr 25 13:20:04 2008 AndreyUpdatePEMMicrophone testIn response to Rana's request, I tested the
microphone (if it is alive or not) by clapping
my hands and speaking aloud nearby.
 Microphone.png 
  452   Sat Apr 26 01:45:38 2008 AndreySummaryPEMWeather Station enhancementTwo more things concerning weather monitoring
have been done during this week.
 Matlab_Weather_Trends.png 
  460   Tue Apr 29 21:30:49 2008 AndreyUpdatePEMIn the process of renaming channels for Weather Station
I startted renaming channels for the weather
station, and I will continue this tomorrow,
  
  461   Wed Apr 30 20:48:58 2008 AndreySummaryPEMNew Weather Channels
I created the new channels for the weather
station, all letters are capital ones. They
 April30-5hours.png 
  480   Thu May 15 14:39:33 2008 CarynSummaryPEMfiltering mode cleaner with micTried filtering for mode cleaner data(C1:IOO-MC_L)
using a siso-firwiener filter and microphone
data(C1:PEM-AS_MIC) for noise input. The
 MC_L_with_PEM-AS_MIC_filter.pdfMC_L_with_PEM-ACC_MC1_X_filter.pdf 
  518   Wed Jun 4 16:25:06 2008 CarynSummaryPEMmicrophone movedThe microphone 'C1:PEM-AS_MIC' has been moved
right a bit. This change didn't seem to have
much effect on filtering the 'C1:IOO-MC_L'
 1_MC_L.pdf 
  522   Fri Jun 6 11:19:13 2008 CarynSummaryPEMFiltering MC_L and MC_F with PEM:ACC and microphoneTried to filter MC_L and MC_F with acc/seis
data and microphone data using wiener filter
(levinson)
 8x 
  547   Fri Jun 20 01:38:55 2008 ranaUpdatePEM20 day WeatherYoichi showed me that its possible to make
PNG images from PS using GS:
 test.png 