  1120   Fri Nov 7 08:08:00 2008 steveUpdatePEMAC turned off in IFO roomAll [COLOR=red]tree[/COLOR] AC units in IFO
room 104 switched off at 7:45am
I'm looking for the periodic thump signal
  
  1121   Fri Nov 7 10:52:57 2008 steveUpdatePEMAC is back onThe 20 minutes and 6 sec thumps are not related
to the 40m ac units
This period is precisely right on so it is
 acf.jpgacc_mc1.jpgtest.jpg 
  1122   Fri Nov 7 15:58:10 2008 ranaUpdatePEMAC is back onI'll bet Steve a dollar that it is mechanical.
The attached PDF compares all of the accelerometers
from right now.
 mc-acc.pdfmc-acc-quad.pdf 
  1126   Mon Nov 10 11:32:49 2008 robUpdateComputersc1iscex rebooted
it was running a few cycles late
  
  1127   Mon Nov 10 16:44:14 2008 steveUpdatePEMparticle counter at MC2The particle counter was moved to MC2 table
temporarily.
It is clamped to the table at the south west
  
  1129   Mon Nov 10 19:39:40 2008 steveUpdatePEMthump noise from particle counterThe particle counter is back on the IOOC location
on a piece of  FOAM 
It needs this isolation, so when the pump
 partcfm.jpg 
  1131   Wed Nov 12 11:36:13 2008 JenneUpdatePEMGuralp Breakout Box is ~50% hooked upThe Guralp box is about halfway hooked up
now.  The seismometer is under the BSC, and
the long cable from the seismometer to the
  
  1134   Fri Nov 14 11:33:19 2008 steveUpdateVACSRS-RGA installedOld Dycor rga is removed and new SRS-RGA200
installed.
It is pumped down and ready for hooking up
  
  1136   Fri Nov 14 19:20:42 2008 YoichiUpdatePSLReference cavity ring downThanks to Bob making the high-voltage BNC
cables for the HV pulse generator, I was
able to operate the EOM in front of
 RingDown.png 
  1137   Fri Nov 14 20:35:47 2008 ranaUpdatePSLReference cavity ring downTo make the DEI pulser make a fast pulse on
the EO shutter EOMs, we had to make sure:
  
  1138   Fri Nov 14 22:40:51 2008 YoichiUpdatePSLReference cavity ring down[quote]
To make the DEI pulser make a fast pulse
on the EO shutter EOMs, we had to make sure:
  
  1140   Mon Nov 17 15:07:06 2008 YoichiUpdatePSLReference cavity ring downI used MATLAB's system identification tool
box to estimate the response of the reference
cavity, i.e. cavity pole.
 Fit.png 
  1141   Mon Nov 17 16:59:22 2008 JenneUpdatePEMSeismometer hooked up, reading channels on DataViewerAlberto, Jenne

The Guralp Seismometer is (finally) hooked
  
  1144   Tue Nov 18 19:37:23 2008 YoichiUpdateIOOMC1 OSEM signals sign flipped and c1susvme1 restart problemAround 2PM, MC1 started to swing crazily.

The damping feedback was not working and
  
  1145   Tue Nov 18 19:44:53 2008 AlbertoUpdateGeneralX Arm Cavity "Negative" FSRs MeasuredPrevious measurements on the X arm cavity
revealed a shift of the frequencies of the
cavity resonances from where one would expect
 2008-11-17_Linear_Fit.pdf 
  1149   Thu Nov 20 09:37:39 2008 steveUpdatePSLMZ vs tempThis 12 days plot shows that it can hold lock
if the daily temp variation is not more than
3/4 of a degree C
 mztemp.jpg 
  1151   Fri Nov 21 16:11:26 2008 rana, alberto, robUpdatePSLMach Zender alignmentThe Mach Zender's dark port DC voltage had
gone up too high (~0.5 V)and was turning
yellow
 PB210051-1.JPG 
  1152   Fri Nov 21 16:52:48 2008 JenneUpdatePEMGuralp seismometer's Channel Problems are solvedPROBLEM noticed earlier this week:  It looked
like one of the seismometer channels (VERT-1)
wasn't working, no matter how I put which
  
  1153   Fri Nov 21 17:27:47 2008 JenneUpdatePEMGuralp noise measurementHere is the data from the Guralp Seismometer
for the past day or so, before I fixed the
VERT-1 channel.  The NS and EW show what's
 guralp_vert_shorted.jpg 
  1154   Fri Nov 21 19:47:26 2008 ranaUpdatePEMGuralp noise measurementand here's the spectra with them connected
- from the coherences, it looks like it needs
to be rotated by 90 deg.
 a.png 
  1155   Fri Nov 21 20:29:43 2008 rana, alberto, robUpdatePSLMach Zender alignment[quote] So now the MZ alignment seems good;
Alberto is on the MC periscope alignment
like a cheap suit.[/quote]
  
  1156   Fri Nov 21 21:20:24 2008 ranaUpdatePEMGuralp noise measurementThis is the spectra and time series of the
Guralp channels along with the Ranger (MC2).
Looks like we could reduce the gain
 a.png 
  1160   Mon Nov 24 17:14:44 2008 ranaUpdatePSLMach Zender trendsIt looks like the MZ has gotten less drifty
after the alignment on Friday.
 Untitled.png 
  1162   Tue Nov 25 18:38:03 2008 Alberto, RobUpdatePSLMC Periscope AlignmentThis morning when I came in I found the MC
cleaner unlocked and the autolocker script
could not lock it. The reflected beam was
  
  1165   Mon Dec 1 15:09:27 2008 robUpdatePEMhalf-micron particle count is alarming    
  1168   Tue Dec 2 19:51:32 2008 ranaUpdatePEMhalf-micron particle count is alarmingThe 0.5 micron dust monitor count is now pretty
high (36000). I wandered around the lab to
see if there was anything
 Untitled.pngdust.png 
  1169   Wed Dec 3 11:58:10 2008 AlbertoUpdatePSLMC AlignmentRana, Alberto,

more details on the MC alignment we did yesterday.
  
  1170   Wed Dec 3 12:49:11 2008 jenneUpdateComputerssomething sketchy with NDS ... or something[SIZE=2][COLOR=green]Never mind...I had forgotten
that you have to run mdv_config every time
you open matlab, not just every time you
  
  1172   Wed Dec 3 20:10:09 2008 Jenne, RanaUpdatePEMComparing Wiener subtraction with different seismometersAttached is a plot of MC_L, and then the residual
MC_L after static Wiener filtering, using
different combinations of our accelerometers
 Dec032008_c1wino_seisCombos.png 
  1173   Wed Dec 3 20:36:07 2008 Jenne, RanaUpdatePEMComparing Wiener subtraction with different seismometersThe Ranger has now been moved over to sit
underneath the MC2 tank (it was previously
close to the PSL rack). It
 d.pdfsco.pngfly.pdf 
  1174   Thu Dec 4 13:49:39 2008 JenneUpdatePEMMore of: Comparing Wiener subtraction using different sensorsHere is another version of the same type plot
I put in the elog yesterday.  This plot is
looking at the 7200 seconds after 04Dec2008
 Dec042008_c1wino_seisCombos.png 
  1176   Thu Dec 4 17:42:23 2008 carynUpdateIOOdrum modes observable without excitationSo, the mode cleaner was evidently aligned
better and now the drum modes are observable
using DTT. 
 drum_modes.pdfdrum_modes2.pdf 
  1179   Fri Dec 5 09:29:59 2008 ranaUpdateIOOdrum modes observable without excitationNot sure what the y-scale is since there aren't
any y axis labels in the plot, but it seems
like we
  
  1182   Fri Dec 5 21:31:11 2008 YoichiUpdateIOOdrum modes observable without excitationThe calibration of the MC_F feedback is posted
in elog:1032.
I'm not sure where Caryn took MC signal,
  
  1183   Sun Dec 7 16:02:46 2008 ranaUpdateGeneralMag 5.1 EQ halfway to VegasThere was a [URL=http://earthquake.usgs.gov/eqcenter/recenteqsww/Quakes/ci14408052.php#details]Mag
5.1 EQ[/URL] Friday night at 8:18 PM.
 g.pngUntitled.png 
  1184   Sun Dec 7 16:12:53 2008 ranaUpdateDAQbooted awg[SIZE=3]because it was [COLOR=red]red[/COLOR][/SIZE]   
  1187   Mon Dec 8 11:54:27 2008 YoichiUpdateGeneralIFO mirrors alignedThis morning, I re-aligned the IFO mirrors
to see if they were badly moved by the earthquake.
The both arms locked just by the restoring
  
  1188   Mon Dec 8 17:50:21 2008 YoichiUpdateSUSITMY driftThe suspension drift monitor shows that the
ITMY alignment was shifted after the earthquake.
Looks like only the UL sensor had a step
 ITMY-OSEMs.pngITMY-UL.pngITMY-08-18.pdfITMY-12-08.pdf 
  1190   Fri Dec 12 22:51:23 2008 YoichiUpdatePSLReference cavity ring down measurement againBob made new HV-cables with HV compatible
coaxes. The coax cable is rated for 2kV,
which was as high as Bob
 RC-Ringdown.png 
  1191   Tue Dec 16 19:06:01 2008 YoichiUpdatePSLReference cavity ring down repeated many timesToday, I repeated the reference cavity ring
down measurement many times to see how much
the results vary.
 RC_Ringdown_Estimates.pngCavity_Pole_Histogram.png 
  1196   Fri Dec 19 14:35:58 2008 Yoichi AlbertoUpdateIOOMC WFS and IOO-POS QPD re-centeringFor the past two days, the MC alignment has
kept drifting.
This morning, the MC alignment was so bad
  
  1197   Fri Dec 19 16:38:09 2008 steveUpdateLSCall optlevs centeredAll optlevs were centered after full alignment.

Qpd sums are:
  
  1199   Sun Dec 21 13:00:06 2008 steveUpdateall down cond.vac and laser back onThere was a power outage sometimes early Saturday.

All things are down.
  
  1200   Sun Dec 21 14:18:04 2008 YoichiUpdateComputersRFM network bypass box's power supply is dead I restarted the front-end computers by power
cycling them one-by-one.
After issuing startup commands, most of them
  
  1201   Mon Dec 22 13:48:22 2008 YoichiUpdateComputersRFM network bypass box's power supply is dead As a temporary fix, I cut the cable of the
power supply and connected it to the Sorensen
power supply +5V on the rack.
  
  1202   Tue Dec 23 10:35:40 2008 YoichiUpdateComputersRFM network breakdown mostly fixedRana, Rolf, Alberto, Yoichi

The source of the problem was the RFM bypass
  
  1203   Wed Dec 24 10:33:24 2008 YoichiUpdateComputersSeveral fixes. Test point problem remains.Yesterday, I fixed several remaining problems
from the power failure.
  
  1204   Wed Dec 24 12:46:54 2008 YoichiUpdateComputersTest points are backRob told me how to restart the test point
manager.
It runs on fb40m and actually there is an
  
  1205   Mon Dec 29 18:01:07 2008 AidanUpdateAuxiliary lockingUpdated 40m Upgrade Document T080074-00-R
Added a paragraph to the 40m Upgrade document
describing the fiber stabilization and frequency
  
  1206   Mon Dec 29 21:38:57 2008 YoichiUpdateComputersSnapshots of MEDM screensI wrote scripts to take snapshots of MEDM
screens in the background.
These scripts work even on a computer without
  
ELOG V3.1.3-