40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 85 of 337  Not logged in ELOG logo
Entry  Tue Sep 7 08:56:00 2010, Alberto, Update, Electronics, Frequency Generation Box Assembly - Phase Noise Measurements 2010-09-03_FreqBoxPhaseNoise_AllOutputsComparison_smooth.png2010-09-03_FreqBoxPhaseNoise_AllOutputsComparison_smooth.pdf
Here are the results of my phase noise measurements on the 7 outputs of the Frequency Generation Box. (BIN=95L applied by DTT). See attached pdf for
a higher definition picture.
Entry  Fri Aug 20 16:41:43 2010, Alberto, Update, Electronics, Frequency Generation Box Assembly Completed 7x
I finished assembling the frequency generation unit for the upgrade. I tested it through to check that the power levels are as expected at the various
connection (see attached png, showing in black the design power values, and in red the measured ones).
Because of some modifications made on the design along the construction, I have to recalculate the SNR along the lines.
Entry  Thu May 8 01:07:24 2008, rana, Summary, LSC, Frequency Noise test: MC Trans Backscatter 
[COLOR=purple][SIZE=4][FONT=Arial]There is a wandering hump in the MC_F spectrum.[/FONT][/SIZE][/COLOR] It can move around on the time 
scale of seconds between 40 and 200 Hz. It has an amplitude ~5-50x above the background spectrum. This seems new; I don't remember it 
from a year ago. It is there in the IFO unlocked as well as the IFO locked as well as the locked + CM mode.
Entry  Sun Dec 7 13:11:57 2014, manasa, Summary, General, Frequency Offset Locking - To Do List FOLtodolist.pdf
Attached is the timeline for Frequency Offset Locking related activities. All activities will be done mostly in morning and early afternoon hours.
    Reply  Fri Dec 12 14:38:39 2014, manasa, Summary, General, Frequency Offset Locking - To Do List (Revised) FOLtodolist.pdf
Unfortunately the order placed for beam samplers last week did not go through. These will be used at the X and Y end tables to dump the unwanted light
appropriately. Since they will not be here until Tuesday, I revised the timeline for FOL related activities accordingly.
Entry  Thu Dec 11 12:39:31 2014, diego, Update, Computer Scripts / Programs, Frequency Offset Locking scripts status 
 I finished the polishing in the scripts/FOL directory, this
is the current status and this post replaces my two previous posts on the subject:

    the Raspberry Pi operates locally: everything
Entry  Tue Jul 14 16:31:46 2009, Clara, Update, PEM, Frequency Response of Microphone (Bonnie) Bonnie_fres_regplot.pdfBonnie_fres_logplot.pdf
So, I actually took these measurements last week, but I didn't get around to making nice plots and things until now. I figured the time while I wait
for the spectrum analyzer to do its thing was a good time.
Having been unable to locate the SR785 and also unsure how to connect it to a computer speaker (and also unable to find a free one), I downloaded
Entry  Wed Nov 7 14:01:31 2007, waldman, Omnistructure, OMC, Frequency and Intensity noise 
One of the biggest problems I had using the PZT to lock was excessive noise.  I did a little noise hunting and found that the problem was the cable running
from the rack to the laser fast input.  As a reminder,  the laser has a 4 MHz / volt fast input.  We require about 300 MHz to go one FSR,  so there is
a Thorlabs HV box between at the NPRO fast input which takes 0-10 V -> 0-150 V.  The 150 V HV range is worth about 600 MHz of NPRO frequency.  
Entry  Fri Oct 4 01:09:33 2013, Manasa, Update, Green Locking, Frequency counter for ALS 
I checked the BK precision 1856D manual. I found that although
this frequency counter can measure upto 3.5GHz, it has 2 separate input channels to measure two range of frequencies.
One input to measure between 0.1Hz to 100 MHz and the other to measure between 80MHz to 3.5GHz. Our beat frequency desirable range is <100MHz
    Reply  Thu Nov 5 03:04:13 2015, gautam, Update, CDS, Frequency counting - systematics and further changes Systematic_error.pdfsystematics_origin.pdf
I've made a few more changes to the frequency counting code - these are mostly details and the algorithm is
essentially unchanged.


The C-code block in the simulink model now outputs the number of clock cycles (=1/16384 seconds) rather than the frequency itself. I've
    Reply  Fri Oct 23 18:36:48 2015, gautam, Update, CDS, Frequency counting - workable setup prepared Yscan.pdf
I've made quite a few changes in the software as well as the hardware of the digital frequency counting setup.


The main change on the software side is that the custom C code that counts intervals between successive zero crossings and updates the
frequency output now has a moving average capability - the window size is readily changable (by a macro in the first line of the code, which resides at 
    Reply  Fri Oct 23 19:27:19 2015, Koji, Update, CDS, Frequency counting - workable setup prepared 
It is a nice scan. I'm still thinking about the equivalence of the moving average and the FIR low pass that I have mentioned in the meeting.

Anyways:

I'm confused by the plot. The bottom axis says "green beat frequency".
    Reply  Sat Oct 24 12:34:43 2015, gautam, Update, CDS, Frequency counting - workable setup prepared Yscan.pdfFrequency_readout.pdf
Sorry for the confusion - I did mean Green beat frequency, and I had neglected the factor of 2 in my earlier calculations. However, the fit
parameter "c" in my fit was actually the half-width at half maximum and not the full width at half maximum. After correcting
for both these errors (new fit is Attachment #1, where I have now accounted for the factor of 2, and the X axis is the IR beat frequency), I don't
Entry  Thu Sep 17 19:58:06 2015, gautam, Summary, Computer Scripts / Programs, Frequency counting algorithm 
I made some changes to the c1tst model running on c1iscey in order to test my algorithm for frequency counting. I followed the steps listed in elog 8909
to make, install and start the model. 

I need to debug a few things and run some more diagnostics so I am leaving the model in its edited version (Eric had committed it to the svn
    Reply  Mon Sep 21 18:31:06 2015, gautam, Summary, Computer Scripts / Programs, Frequency counting algorithm 6x
I have been working on setting up a frequency counting module that can give us a readout of the beat frequency, divided
by a factor of 2^14 using the Wenzel frequency dividers as described here. This is a summary
of what I have thus far.
    Reply  Mon Sep 21 23:18:55 2015, ericq, Summary, Computer Scripts / Programs, Frequency counting algorithm 
I definitely think lowpassing the output is the way to go. Since this frequency readback will be used for slow control of the beatnote frequency via
auxillary laser temperature, even lowpassing at tens of Hz is fine. The jitter doesn't mean its useless, though.

If we lowpass at 16Hz, we're effectively averaging over 1024 samples, bringing, for example, a +-2kHz jitter of a 6kHz signal as you post
    Reply  Tue Sep 22 02:11:17 2015, rana, Summary, Computer Scripts / Programs, Frequency counting algorithm 
I was going to suggest using a software PLL, but perhaps averaging gives the same result. The same ADC signal can be fed to multiple blocks with different
averaging times and we can just use whichever ones seems the most useful.
    Reply  Tue Oct 20 17:36:01 2015, gautam, Update, CDS, Frequency counting with moving average 
I'm working on setting up a moving-average in the custom C code block that counts the zero crossings to see if this approach is able to mitigate
the glitchy frequency readout due to mis-counting by one clock cycle between successive zero crossings. I'm storing an array the size of the moving
average window of frequency readouts at each clock cycle, and then taking the arithmetic mean over the window. By keeping a summing variable that updates
    Reply  Tue Sep 29 03:14:04 2015, gautam, Update, CDS, Frequency divider box IMG_0014.JPGIMG_0015.JPG
Earlier today, the front panels for the 1U chassis I obtained to house the Wenzel dividers + RF amplifiers arrived, which meant that finally I had everything
needed to complete the assembly. Pictures of the finished arrangement attached. 

Summary of the arrangement:
    Reply  Mon Oct 12 17:04:02 2015, gautam, Update, CDS, Frequency divider box - further tests calibration.pdfsystematics.pdf
I carried out some more tests on the digital frequency counting system today, mainly to see if the actual performance mirrors the expected systematic
errors I had calculated here. 

Setup and measurement details:
    Reply  Wed Oct 14 17:40:50 2015, gautam, Update, CDS, Frequency divider box - further tests time_series_input_signals.pdfcalibration_20151012.pdfsystematics_20151012.pdf
Summary:

I carried out some further diagnostics and found some ways in which I could optimize the zero-crossing-counting algorithm, such that the error
in the measured frequency is now entirely within the expected range (due to a +-1 clock cycle error in the counting). We can now determine frequencies
    Reply  Fri Oct 9 19:54:58 2015, gautam, Update, CDS, Frequency divider box - installation in 1X2 rack IMG_0027.JPGtime_seris_25MHz.pdf
The new ZKL-1R5 RF amplifier that Steve ordered arrived yesterday. I installed this in the frequency divider box and did a quick check using the Fluke
RF signal generator and an oscilloscope to verify that both the X and Y paths were working. 

I've now installed the box in the 1X2 rack where the olf "RF amplifiers for ALS and FOL" box used to sit (I swapped that out as
Entry  Wed Jun 25 01:30:19 2008, John, Summary, IOO, Frequency noise after the MC MC2noise080623.png
I made some (very) rough estimates of the contribution made to the noise after the mode cleaner by three sources.

[COLOR=pink][B]Seismic noise[/B][/COLOR] - how much of the signal is due to the mode cleaner compenstaing for seismic disturbance of CARM.
Entry  Fri Apr 5 11:40:57 2019, Anjali, Update, Frequency noise measurement, Frequency noise measurement of 1 micron source Modified_experimental_setup.JPGChecking_polarisation.pdfChecking_the_polarisation_alignment_of_the_delay_fiber.pdfSetup_to_test_the_polarisation_alignment_of_delay_fiber.JPG

Attachment #1 shows the present experimental setup. The photodiode is now replaced with PDA255. The farther end of the fiber (output of the delayed
arm) is coupled through a collimator and aligned such that the beam from the delayed path fall on the detector along with the undelayed path of MZI. We
tried to measure the frequency noise of the laser with this setup, but we didn’t get anything sensible.

One of the main draw backs
Entry  Sat Apr 6 02:07:40 2019, Anjali, Update, Frequency noise measurement, Frequency noise measurement of 1 micron source 

The alignment of the output beam from the delayed path of MZI to the photodetector was disturbed when we did the polarisation characterisation
yesterday. So, today we tried to align the output beam from the delayed path of MZI to the detector .
We then observed the beat output
from the detector on oscilloscope.We initialy observed a dc shift . We then applied a frequency modulation on the input laser and observed the output
    Reply  Wed Apr 10 00:33:09 2019, Anjali, Update, Frequency noise measurement, Frequency noise measurement of 1 micron source Modulation_frequency_100Hz.jpgModulation_frequency_30Hz.jpgModified_setup.JPG

Attachement #1 shows the input (ch4-green) modulation frequency and the photodiode output (ch1-yellow) when the modulation frequency is
about 100 Hz
Attachement #2 shows the input (ch4-green) modulation frequency and the photodiode output (ch1-yellow) when the modulation
frequency is about 30 Hz
The output frequency is varying in accordance with variation in modulation frequency. It is observed that, for a given
    Reply  Fri Apr 12 01:22:27 2019, Anjali, Update, Frequency noise measurement, Frequency noise measurement of 1 micron source 
The alignement was disturbed after the replcement of the beam splitter. We tried to get the alignment back . But we are not succeeded yet in getting
good interfernce pattern. This is mainly because of poor mode matching of two beams. We will also try with the spooled fiber.




Quote:


Entry  Fri Apr 26 12:10:08 2019, Anjali, Update, Frequency noise measurement, Frequency noise measurement of 1 micron source Time_domain_data.pdfFrequency_noise_from_data_in_linear_region.pdf
From the earlier results with homodyne measurement,the Vmax and Vmin values observed were comparable with the expected results
. So in the time interval between these two points, the MZI is assumed to be in the linear region and I tried to find the frequency noise based 
on data available in this region.This results is not significantly different from that we got before when we took the complete time series to calculate
Entry  Tue Apr 30 17:27:35 2019, Anjali, Update, Frequency noise measurement, Frequency noise measurement of 1 micron source Homodyne_repeated_measurement.zip
We repeated the homodyne measurement to check whether we are measuring the actual frequency noise of the laser. The idea was to repeat the
experiment when the laser is not locked and when the laser is locked to IMC.The frequency noise of the laser is expected to be reduced at higher frequency 
(the expected value is about 0.1 Hz/rtHz at 100 Hz ) when it is locked to IMC . In this measurement, the fiber beam splitter used is Non PM. Following
Entry  Mon Nov 23 20:32:43 2015, Koji, Update, LSC, Frequency source fixed, IMC LO level adjusted 
The frequency source was fixed. The IMC LO level was adjusted.

IMC is locked => OLTF measured UGF 144kHz PM 30deg.
    Reply  Mon Nov 23 21:48:49 2015, Koji, Update, LSC, Frequency source fixed, IMC LO level adjusted IMG_2136.JPGIMG_2129.JPGIMG_2133.JPG
The trouble we had: the 29.5 MHz source had an output of 6 dBm instead of 13 dBm.

The cause of the issue: A short cable inside had its shield cut and had no connection of the return.


- The frequency source box was dismantled.
Entry  Fri Mar 8 08:40:26 2019, Anjali, Configuration, , Frequency stabilization of 1 micron source Homodyne_setup.png
The schematic of the homodyne configuration is shown below.

Following are the list of components




Item
Quantity
Availability
Part
Entry  Fri Jan 13 00:51:40 2012, Leo Singer, Update, Stewart platform, Frequency-dependent requirements for Stewart platform ground_velocity_spectrum.pngrequirements.png
Below are revised design parameters for the Stewart platform based on ground motion measurements.
The goal is that the actuators should be able to exceed ground motion by a healthy factor (say, two decades in amplitude) across a range from about
.1 Hz to 500 Hz.  I would like to stitch together data from at least two seismometers, an accelerometer, and (if one is available) a microphone, but
Entry  Mon Dec 2 23:01:47 2019, gautam, Update, CDS, Frequent DTT crashes on pianosa DTTerrorLog.tgz
I have been experiencing frequent crashes of
DTT on pianosa in the past few weeks. This is pretty annoying to deal with when trying to characterize the interferometer loops. I
attach the error log dumped to console. The error has to do with some kind of memory corruption. Recall that we aren't using a GDS version that is
Entry  Fri Apr 6 16:07:18 2018, gautam, Update, CDS, Frequent EPICS dropouts EPICS_dropout.png
Kira informed me that she was having trouble accessing past data for her PID tuning tests. Looking at the last day of data, it looks like there are frequent EPICS data dropouts, each up to a few hours. Observations (see Attachment
#1 for evidence):
Entry  Fri Sep 21 19:50:17 2018, Koji, Update, CDS, Frequent time out 33.png49.pngScreenshot_from_2018-09-21_21-52-54.png
Multiple realtime processes on c1sus are suffering from frequent time outs. It eventually knocks out c1sus (process).

Obviously this has started since the fiber swap this
afternoon.
    Reply  Sat Sep 22 00:21:07 2018, Koji, Update, CDS, Frequent time out 23.png
[Gautam, Koji]

We had another crash of c1sus and Gautam did full power cycling of c1sus. It was a sturggle to recover all the frontends, but this solved the
timing issue.
    Reply  Tue Jan 12 03:03:55 2016, ericq, Update, LSC, Frequently making noise 
Gautam will soon follow up with detailed analysis, but here is a brief summary of some of our activities and findings.


Two Marconis were beat together in various ways, we figured the noise added by turning on external modulation didn't make us happy. 
I
locked the AUX X laser to the PSL via PZT. I'm more likely to believe we're seeing real broadband laser noise in this configuration; locking the
    Reply  Tue Jan 12 19:38:31 2016, gautam, Update, LSC, Frequently making noise 2016_01_AUXLaser.tar.gzOLGs.pdfvariedCurrent.pdfvariedTemp.pdfPLL_setup.pdf
EDITS 15Jan:


Schematic of test setup added (Attachment #5). Note that the UGF measurements were made with the
LPF and gain on the 'wrong' SR560, in a way defeating the purpose of having 2 SR560s in the setup. I only realised this after taking the measuements.
Entry  Sun Jun 26 16:02:12 2011, kiwamu, Update, IOO, Friday MC activity 
[Rana / Kiwamu]
 Last Friday we did several things for MC :
   - aligned the incident beam to MC
Entry  Sun Feb 16 17:40:11 2014, Koji, Update, LSC, Friday Night ALS 
I wanted to try common/differential ALS Friday evening. I tried ALS using the LSC servo but this was not successfull.
The usual ALS servo in the ALS model works without problem. So this might be coming from the shape of the servo filter.
The ALS one has 1:1000 filter but the LSC one has 10:3000. Or is there any problem in the signal transfer between 
Entry  Tue Sep 4 11:32:58 2012, Jenne, Update, Locking, Friday in-vac work 
Elog re: Friday's work
Adjusted PZT2 so we're hitting the center of PR2. 
Noticed that the beam centering target is too low by a few mm, since the OSEM set screw holes that it mounts to are lower than the center line
Entry  Sat Jun 25 06:09:38 2011, kiwamu, Update, LSC, Friday locking 
I was able to measure the sensing matrix in the PRMI configuration.
The results will be posted later.
Entry  Sat Aug 15 05:08:55 2009, Yoichi, Update, Locking, Friday night locking 
Summary: DD hand off fails for DRFPMI.

Tonight, I did a lot of house keeping work.
Entry  Sun Nov 4 23:55:24 2007, rana, Update, IOO, Friday's In-Vac work 
On Friday morning when closing up we noticed that we could not get the MC to flash any modes.
We tracked this down to a misalignment of MC3. Rob went in and noticed that the stops were 
still touching. Even after backing those off the beam from MC3 was hitting the east edge of
    Reply  Mon Nov 5 07:29:35 2007, rana, Update, IOO, Friday's In-Vac work 
Liyuan recently did some of his pencil beam scatterometer measurements measuring not the
[URL=http://en.wikipedia.org/wiki/Bidirectional_reflectance_distribution_function]BRDF[/URL] but instead the total integrated power radiated from each
surface point
Entry  Tue Jan 25 22:49:13 2011, Koji, Update, CDS, Front End multiple crash 
STATUS: 

    Rebooted c1lsc and c1sus. Restarted fb many times.
    c1sus seems working. 
    All of the suspensions
are damped / Xarm is locked by the green
    Thermal control for the green is working
    
    Reply  Wed Jan 26 10:58:48 2011, josephb, Update, CDS, Front End multiple crash 
Looking at dmesg on c1lsc, it looks like the model is starting, but then eventually times out due to a long ADC wait. 

[  114.778001] c1lsc: cycle 45 time 23368; adcWait 14; write1 0; write2 0; longest write2 0
    Reply  Wed Jan 26 12:03:45 2011, Koji, Update, CDS, Front End multiple crash 
This is definitely a nice magic to know as the rebooting causes too much hustles.
Also, you and I should spend an hour in the afternoon to add the suspension swtches to the burt requests.


    
        
            
Entry  Mon Nov 1 15:35:41 2010, josephb, Update, CDS, Front end USR and CPU times now recorded by DAQ 
Problem:
We have no record of how long the CPUs are taking to perform a cycle's worth of computation
Solution:
ELOG V3.1.3-