    Reply  Wed Jan 5 22:14:41 2011, rana, Summary, DAQ, FrameBuilder fails in a new way Screen_shot_2011-01-05_at_10.13.21_PM.png
Just a proof that the DAQ is working - ran DTT on nodus from 3 hours ago.
Entry  Thu Dec 13 22:56:28 2018, gautam, Update, CDS, Frames 
[koji, gautam]

We looked into the /frames situation a bit tonight. Here is a summary:


We have already lost some second trend data since the new FB has been running from ~August 2017.
The minute
Entry  Thu Feb 17 23:41:46 2011, rana, Frogs, DAQ, Frames Directory got the wrong name: Data unreachable 
DTT stopped working for recent data. An 'ls' in the frames/full/ directory reveals:
drwxr-xr-x 2 controls controls 258048 Feb  3 12:26 9807
drwxr-xr-x 2 controls controls 258048 Feb  4 16:13 9808
Entry  Wed Oct 4 17:18:15 2017, gautam, Update, CDS, Free DAC channels in c1lsc 
There are at least 5 free DAC channels (4 if you discount the one channel from these that I am hijacking) available in the 1Y2 electronics rack.

Jamie's nice wiring diagram shows the topology
- the actual DAC card sits in 1Y3 inside the c1lsc expansion chassis (while the c1lsc frontend itself is in 1X4). The output of the DAC goes via SCSI to
Entry  Wed Sep 25 17:07:08 2013, rana, Frogs, Treasure, Free Green Mango Juice in fridge aam_pana_recipe.jpg

its an acquired taste, but its a must since we're sending an interferometer to India
Entry  Tue Sep 6 17:43:01 2011, Suresh, Update, IOO, Free Swing ITMY started 
Free swing of ITMY started at
Tue Sep  6 17:41:43 PDT 2011
 
    Reply  Tue Sep 6 17:56:53 2011, Jenne, Update, IOO, Free Swing ITMY started 


    
        
            Quote:
        
        
            
            Free swing of ITMY started at
    Reply  Thu Dec 10 17:13:36 2009, kiwamu, Update, SUS, Free swiging spectra under the atmospheric pressure summary_freeswing.pdf
The free swinging spectra of ITMs, ETMs, BS, PRM and SRM were measured last night in order to make sure that nothing wrong have happened by the wiping.
I think there are nothing wrong with ITMs, ETMs, BS, PRM and SRM successfully.
For the comparison, Yoichi's figure in his elog entry of
Entry  Thu Sep 29 16:19:29 2016, Lydia, Update, SUS, Free swing eigenmodes 05.pngSUS_eigenmodes.png
[Lydia, Teng]

Motivated by the strange pitch/yaw coupling behavior we ran into while doing diagonalization, we looked at the oplev pitch and yaw free swing
spectra for all 4 test masses (see attachment 1). We saw the same behavior there: At the peak frequencies for
Entry  Thu Aug 14 19:08:14 2008, Yoichi, Configuration, SUS, Free swing measurement going on 
I started free swinging spectra measurement of all the suspensions now Aug 14 19:05 (PDT).
The watch dogs are all shutdown. Please do not turn them back on until tomorrow morning.
Entry  Thu Sep 5 15:18:41 2013, Jenne, Update, LSC, Free swinging DRMI power buildups DRMI_free_swing_power_buildups.pdf
I have the DRMI free swinging right now, since it's not really locking.  Looking at these time series in the attached pdf, particularly around time=1.15,
it would be super handy to trigger the SRCL degree of freedom on AS110 after the PRMI is triggered on POP22.
Entry  Thu Aug 7 10:07:13 2008, Yoichi, Update, SUS, Free swinging OSEM spectra FreeSwingSpectra.pdf
Looks like there are more extra peaks in the SRM than other optics.
Maybe because it is closer to the door ?
    Reply  Thu Aug 7 10:27:59 2008, rana, Update, SUS, Free swinging OSEM spectra 
Sometimes we see extra peaks in the OSEM spectra coming from a beat between the regular eigenmodes.
This probably comes from the OSEM shadow sensor not being entirely linear - the nonlinearity is
greatly increased if the magnet is not perfectly centered in the LED beam. So the beats are
Entry  Tue Dec 8 03:53:49 2009, kiwamu, Update, SUS, Free swinging spectra of ETMX  ETMX_air.png
In this night, I checked the free swinging spectra of ETMX to make sure nothing wrong with ETMX by the wiping.
Compared with the past (Aug.6 2008), the spectra of ETMX doesn't show significant change.
Successfully 
Entry  Thu Aug 2 11:09:52 2012, Eric, Summary, LSC, Free-Swinging Michelson Measurements free_swing_MICH.png
To take the free swinging Michelson measurements for the interferometer calibration Jamie aligned the beam splitter with ITMX and ITMY. I recorded the
GPS time (1027827100 and for several hundred seconds later) when the Michelson was aligned in order to look at the correct data. I then copied the python
script nds-test.py from Jamie, and modified it to take and plot data from C1:LSC-AS55_Q_ERR_DQ offline. I used dataviewer to verify that C1:LSC-AS55_Q_ERR_DQ
Entry  Fri Aug 19 01:15:22 2011, Suresh, Update, SUS, FreeSwing all optics 
I ran "freeswing all" at Fri Aug 19 01:09:28 PDT 2011 (997776583)  and "opticshutdown"  as well.
 
Entry  Thu Sep 24 17:01:37 2015, ericq, Update, Computer Scripts / Programs, Freeing up some space on /cvs/cds 
I noticed that Chiara's backup HD (which has a capacity of 1.8TB, vs the main drives 2TB) was near to getting full, meaning that we would soon be
without a local backup. 

I freed up ~200GB of space by compressing the autoburt snapshots from 2012, 2013, 2014. Nothing is deleted, I've just compressed text files
Entry  Wed Sep 7 00:44:51 2011, Jenne, Update, SUS, Freeswing all 
I just started a freeswing all, as a final check before we pump:

Wed Sep  7 00:43:21 PDT 2011
    Reply  Tue May 24 15:21:13 2022, Anchal, Update, BHD, Freeswing tests of new SOS started 
I modified the script freeSwing.py to use damping loop output switches
to free the optic instead of watchdog or coil output filters. This ensures that the free swing test is being done at the nominal position of the optic.
I started tests for LO1, LO2, As2, As4, PR2, PR3, and SR2 in a tmux session names freeSwing on rossa.
    Reply  Sat Dec 5 20:44:35 2020, gautam, Update, ASC, Freq Gen Box re-installed 6x
This work is now complete. The box was characterized and re-installed in 1X2. I am able to (briefly) lock the IMC and see PDH fringes in POX and POY
so the lowest order checks pass.

Even though I did not deliberately change anything in the 29.5 MHz path, and I confirmed that the level at the output is the expected 13 dBm,
    Reply  Fri Dec 4 22:41:56 2020, gautam, Update, ASC, Freq Gen Box revamp 
This turned out to be a much more involved project than I expected. The layout is complete now, but I found several potentially damaged sections of cabling
(the stiff cables don't have proper strain relief near the connectors). I will make fresh cables tomorrow before re-installing the unit in the rack.
Several changes have been made to the layout so I will post more complete details after characterization and testing.
    Reply  Wed Feb 2 10:44:26 2011, Koji, Summary, Green Locking, Freq fluctuation measured by the freq divider and Rana's analog PFD 110201_green_freq_fluctuation.pdf
The freq fluctuation of the beat note has been measured with the following condition

    The IR beam only locked to the MC. The green beam locked to the arm
    Both of the IR and green locked to the x-arm

Calibration
- The output of the freq divider is already calibrated to have the unit of MHz.
    Reply  Wed Feb 2 12:55:34 2011, Koji, Summary, Green Locking, Freq fluctuation measured by the freq divider and Rana's analog PFD 
I found that some flakiness of the beat signals comes from the RF components for the beat detection.
They are touching the racks in an indefinite way. If we move the components the output of the analog PFD 
goes crazy.
Entry  Mon Sep 13 11:40:50 2010, Alberto, Update, Electronics, Frequency Box Documentation Added to the SVN freqBoxSVNdierctoryStructure.png
I uploaded all the material about the RF frequency Generation Box  into the SVN under the path:
https://nodus.ligo.caltech.edu:30889/svn/trunk/docs/upgrade08/RFsystem/frequencyGenerationBox/
I structured the directory as shown in this tree:
    Reply  Tue Sep 14 18:07:41 2010, Alberto, Update, Electronics, Frequency Box Documentation Added to the SVN 
I completed a LIGO document describing design, construction and characterization of the RF System for the 40m upgrade.
It is available on the SVN under https://nodus.ligo.caltech.edu:30889/svn/trunk/docs/upgrade08/RFsystem/RFsystemDocument/
It can also be found on the 40m wiki (http://lhocds.ligo-wa.caltech.edu:8000/40m/Upgrade_09/RF_System#preview), and DCC under the number T1000461.
Entry  Mon Jun 9 09:51:11 2014, Sai Akhil, Update, Electronics, Frequency Error Measurement of UFC-6000 RF Frequency Counter Data_and_Script_Files.zipError_Measurement_FC.pdfError_freq.jpg
 Motivation: 
 
To test the precision of Mini-Circuits Model UFC-6000 RF Frequency Counter which will be used for recording the beat note
for the Frequency Offset Locking Loop(FOLL).
 
 
Setup:
 
Mini
Entry  Thu Sep 9 12:02:03 2010, Alberto, Update, Electronics, Frequency Generation Box - Amplitude Noise Measurements FreqBoxAmplitudeNoiseMeasurementSetup.pngFreqBoxAmplitudeNoise_BusbyBox_AllChannels.png
I measured the amplitude noise of the source outputs and the EOM outputs of the Frequency Generation box.
the setup I used is shown in this diagram:
Entry  Tue Sep 7 08:56:00 2010, Alberto, Update, Electronics, Frequency Generation Box Assembly - Phase Noise Measurements 2010-09-03_FreqBoxPhaseNoise_AllOutputsComparison_smooth.png2010-09-03_FreqBoxPhaseNoise_AllOutputsComparison_smooth.pdf
Here are the results of my phase noise measurements on the 7 outputs of the Frequency Generation Box. (BIN=95L applied by DTT). See attached pdf for
a higher definition picture.
Entry  Fri Aug 20 16:41:43 2010, Alberto, Update, Electronics, Frequency Generation Box Assembly Completed 7x
I finished assembling the frequency generation unit for the upgrade. I tested it through to check that the power levels are as expected at the various
connection (see attached png, showing in black the design power values, and in red the measured ones).
Because of some modifications made on the design along the construction, I have to recalculate the SNR along the lines.
Entry  Thu May 8 01:07:24 2008, rana, Summary, LSC, Frequency Noise test: MC Trans Backscatter 
[COLOR=purple][SIZE=4][FONT=Arial]There is a wandering hump in the MC_F spectrum.[/FONT][/SIZE][/COLOR] It can move around on the time 
scale of seconds between 40 and 200 Hz. It has an amplitude ~5-50x above the background spectrum. This seems new; I don't remember it 
from a year ago. It is there in the IFO unlocked as well as the IFO locked as well as the locked + CM mode.
Entry  Sun Dec 7 13:11:57 2014, manasa, Summary, General, Frequency Offset Locking - To Do List FOLtodolist.pdf
Attached is the timeline for Frequency Offset Locking related activities. All activities will be done mostly in morning and early afternoon hours.
    Reply  Fri Dec 12 14:38:39 2014, manasa, Summary, General, Frequency Offset Locking - To Do List (Revised) FOLtodolist.pdf
Unfortunately the order placed for beam samplers last week did not go through. These will be used at the X and Y end tables to dump the unwanted light
appropriately. Since they will not be here until Tuesday, I revised the timeline for FOL related activities accordingly.
Entry  Thu Dec 11 12:39:31 2014, diego, Update, Computer Scripts / Programs, Frequency Offset Locking scripts status 
 I finished the polishing in the scripts/FOL directory, this
is the current status and this post replaces my two previous posts on the subject:

    the Raspberry Pi operates locally: everything
Entry  Tue Jul 14 16:31:46 2009, Clara, Update, PEM, Frequency Response of Microphone (Bonnie) Bonnie_fres_regplot.pdfBonnie_fres_logplot.pdf
So, I actually took these measurements last week, but I didn't get around to making nice plots and things until now. I figured the time while I wait
for the spectrum analyzer to do its thing was a good time.
Having been unable to locate the SR785 and also unsure how to connect it to a computer speaker (and also unable to find a free one), I downloaded
Entry  Wed Nov 7 14:01:31 2007, waldman, Omnistructure, OMC, Frequency and Intensity noise 
One of the biggest problems I had using the PZT to lock was excessive noise.  I did a little noise hunting and found that the problem was the cable running
from the rack to the laser fast input.  As a reminder,  the laser has a 4 MHz / volt fast input.  We require about 300 MHz to go one FSR,  so there is
a Thorlabs HV box between at the NPRO fast input which takes 0-10 V -> 0-150 V.  The 150 V HV range is worth about 600 MHz of NPRO frequency.  
Entry  Fri Oct 4 01:09:33 2013, Manasa, Update, Green Locking, Frequency counter for ALS 
I checked the BK precision 1856D manual. I found that although
this frequency counter can measure upto 3.5GHz, it has 2 separate input channels to measure two range of frequencies.
One input to measure between 0.1Hz to 100 MHz and the other to measure between 80MHz to 3.5GHz. Our beat frequency desirable range is <100MHz
    Reply  Thu Nov 5 03:04:13 2015, gautam, Update, CDS, Frequency counting - systematics and further changes Systematic_error.pdfsystematics_origin.pdf
I've made a few more changes to the frequency counting code - these are mostly details and the algorithm is
essentially unchanged.


The C-code block in the simulink model now outputs the number of clock cycles (=1/16384 seconds) rather than the frequency itself. I've
    Reply  Fri Oct 23 18:36:48 2015, gautam, Update, CDS, Frequency counting - workable setup prepared Yscan.pdf
I've made quite a few changes in the software as well as the hardware of the digital frequency counting setup.


The main change on the software side is that the custom C code that counts intervals between successive zero crossings and updates the
frequency output now has a moving average capability - the window size is readily changable (by a macro in the first line of the code, which resides at 
    Reply  Fri Oct 23 19:27:19 2015, Koji, Update, CDS, Frequency counting - workable setup prepared 
It is a nice scan. I'm still thinking about the equivalence of the moving average and the FIR low pass that I have mentioned in the meeting.

Anyways:

I'm confused by the plot. The bottom axis says "green beat frequency".
    Reply  Sat Oct 24 12:34:43 2015, gautam, Update, CDS, Frequency counting - workable setup prepared Yscan.pdfFrequency_readout.pdf
Sorry for the confusion - I did mean Green beat frequency, and I had neglected the factor of 2 in my earlier calculations. However, the fit
parameter "c" in my fit was actually the half-width at half maximum and not the full width at half maximum. After correcting
for both these errors (new fit is Attachment #1, where I have now accounted for the factor of 2, and the X axis is the IR beat frequency), I don't
Entry  Thu Sep 17 19:58:06 2015, gautam, Summary, Computer Scripts / Programs, Frequency counting algorithm 
I made some changes to the c1tst model running on c1iscey in order to test my algorithm for frequency counting. I followed the steps listed in elog 8909
to make, install and start the model. 

I need to debug a few things and run some more diagnostics so I am leaving the model in its edited version (Eric had committed it to the svn
    Reply  Mon Sep 21 18:31:06 2015, gautam, Summary, Computer Scripts / Programs, Frequency counting algorithm 6x
I have been working on setting up a frequency counting module that can give us a readout of the beat frequency, divided
by a factor of 2^14 using the Wenzel frequency dividers as described here. This is a summary
of what I have thus far.
    Reply  Mon Sep 21 23:18:55 2015, ericq, Summary, Computer Scripts / Programs, Frequency counting algorithm 
I definitely think lowpassing the output is the way to go. Since this frequency readback will be used for slow control of the beatnote frequency via
auxillary laser temperature, even lowpassing at tens of Hz is fine. The jitter doesn't mean its useless, though.

If we lowpass at 16Hz, we're effectively averaging over 1024 samples, bringing, for example, a +-2kHz jitter of a 6kHz signal as you post
    Reply  Tue Sep 22 02:11:17 2015, rana, Summary, Computer Scripts / Programs, Frequency counting algorithm 
I was going to suggest using a software PLL, but perhaps averaging gives the same result. The same ADC signal can be fed to multiple blocks with different
averaging times and we can just use whichever ones seems the most useful.
    Reply  Tue Oct 20 17:36:01 2015, gautam, Update, CDS, Frequency counting with moving average 
I'm working on setting up a moving-average in the custom C code block that counts the zero crossings to see if this approach is able to mitigate
the glitchy frequency readout due to mis-counting by one clock cycle between successive zero crossings. I'm storing an array the size of the moving
average window of frequency readouts at each clock cycle, and then taking the arithmetic mean over the window. By keeping a summing variable that updates
    Reply  Tue Sep 29 03:14:04 2015, gautam, Update, CDS, Frequency divider box IMG_0014.JPGIMG_0015.JPG
Earlier today, the front panels for the 1U chassis I obtained to house the Wenzel dividers + RF amplifiers arrived, which meant that finally I had everything
needed to complete the assembly. Pictures of the finished arrangement attached. 

Summary of the arrangement:
    Reply  Mon Oct 12 17:04:02 2015, gautam, Update, CDS, Frequency divider box - further tests calibration.pdfsystematics.pdf
I carried out some more tests on the digital frequency counting system today, mainly to see if the actual performance mirrors the expected systematic
errors I had calculated here. 

Setup and measurement details:
    Reply  Wed Oct 14 17:40:50 2015, gautam, Update, CDS, Frequency divider box - further tests time_series_input_signals.pdfcalibration_20151012.pdfsystematics_20151012.pdf
Summary:

I carried out some further diagnostics and found some ways in which I could optimize the zero-crossing-counting algorithm, such that the error
in the measured frequency is now entirely within the expected range (due to a +-1 clock cycle error in the counting). We can now determine frequencies
    Reply  Fri Oct 9 19:54:58 2015, gautam, Update, CDS, Frequency divider box - installation in 1X2 rack IMG_0027.JPGtime_seris_25MHz.pdf
The new ZKL-1R5 RF amplifier that Steve ordered arrived yesterday. I installed this in the frequency divider box and did a quick check using the Fluke
RF signal generator and an oscilloscope to verify that both the X and Y paths were working. 

I've now installed the box in the 1X2 rack where the olf "RF amplifiers for ALS and FOL" box used to sit (I swapped that out as
Entry  Wed Jun 25 01:30:19 2008, John, Summary, IOO, Frequency noise after the MC MC2noise080623.png
I made some (very) rough estimates of the contribution made to the noise after the mode cleaner by three sources.

[COLOR=pink][B]Seismic noise[/B][/COLOR] - how much of the signal is due to the mode cleaner compenstaing for seismic disturbance of CARM.