ID Date Authorup Type Category Subject Text Attachments
  16822   Mon May 2 10:00:34 2022 JordanUpdateVACTP3 Forepump tip seal replacement[JC, Jordan]

Jordan recieved the new tip seal
Friday afternoon and I continued the replacement
  
  10279   Sat Jul 26 15:30:15 2014 Joseph AreedaUpdateComputer Scripts / ProgramsNDS2 server propem on megatronThe NDS2 server on megatron was unresponsive
for what i think was the last couple of days.
The NDS the log file (~nds2mgr/logs/nds2-201407151045.log)
  
  5254   Wed Aug 17 12:14:27 2011 Josh SmithOmnistructureComputer Scripts / Programs40m summary page plansJosh Smith, Fabian Magana-Sandoval, Jackie
Lee (Fullerton)
Thanks to Jamie and Jenne for the
  
  1221   Fri Jan 9 17:30:10 2009 KakeruUpdateComputersSnapshots of MEDM screensI wrote a web page which shows snapshots of
MEDM screens generated by Yoich's script
(e-log #1206).
  
  1225   Tue Jan 13 18:59:09 2009 KakeruUpdateLSCAS CCD centering and ASDD demod phaseI tuned the demod-phase for PRCL and SRCL
hand-off, but it have not been optimized
enoughly.
  
  1241   Wed Jan 21 16:18:17 2009 KakeruUpdateLSCAS CCD centering and ASDD demod phaseI tuned the DD demod-pahse for SRM.
It was tuned as the error singnal is to be
0 when the cavity is locked.
  
  1249   Fri Jan 23 12:48:12 2009 KakeruUpdateoplevsarm cavity oplev calibrationI calibrated optlevs of x and y arm cavity,
indipendently from Peter's work.
 ITMX_pitch.png 
  1259   Thu Jan 29 17:24:41 2009 KakeruUpdateoplevsarm cavity oplev calibrationI calibrated optlevs again. My previous work
has a lot of mistakes, so ignore it.
  
  1262   Fri Jan 30 19:38:57 2009 KakeruUpdatePSLISS BadKakeru, Peter

We try to improve ISS bord, but there isn't
  
  1277   Fri Feb 6 09:52:35 2009 KakeruUpdatePSLCurrent shunt transfar functionI attach the transfar function of the current
shunt.
There is a little gap at 10 Hz for
 TF_CS_gain.pngTF_CS_phase.png 
  1278   Fri Feb 6 09:56:11 2009 KakeruUpdatePSLISS servo transfar functionI attache the transfar function of ISS
servo.
The 4th stage and variable gain amplifier
 TF_ISSservo_gain.pngTF_ISSservo_phase.png 
  1279   Fri Feb 6 10:46:40 2009 KakeruUpdatePSLISS servo and noiseI measured the output noise of eache stage
of ISS servo, and calcurated the noise ratio
between input and 
 ISS_servo_TF_noise.png 
  1289   Tue Feb 10 23:36:25 2009 KakeruUpdatePSLPA current and laser outputI changed the PA current and measured laser
output power (monitor PD signal).
The gain of ISS is 13dB
 PA_current_output.png 
  1295   Wed Feb 11 23:51:53 2009 KakeruUpdatePSLPA current and laser outputI attached a plot of ISS monitor PD and MOPA
output to PA current.
The both end of PA current (26.0353[A] and
 PA_current_output.png 
  1299   Thu Feb 12 18:35:10 2009 KakeruConfigurationPSLPA current limitter
I added a PA current limiter.
It is only a voltage devider (composed
  
  1328   Fri Feb 20 01:54:18 2009 KakeruUpdateComputer Scripts / Programstdsdata might have a bugI found a strange jump of value in my data
taken with tdsdata.
I couldn't find same jump in
 jumped_data.png 
  1362   Thu Mar 5 23:18:38 2009 KakeruConfigurationComputerstdsdata doesn't workI found that tdsdata doesn't work.

When I star tdsdata, he takes a few ~ 10
  
  1375   Mon Mar 9 14:57:30 2009 KakeruUpdateComputer Scripts / Programstdsdata doesn't workI tested new tdsdata and found it was working
well.
I excited C1:SUS-ITMY_SUSPIT_EXC
 oldtds.pngnewtds.png 
  1398   Thu Mar 12 20:59:04 2009 KakeruUpdateIOOMC drift is terribleAfter Rana went for his dinner, I aligned
periscope to make the MC output 3.2 (Attachment
1).
 MCtrans090312.png 
  1403   Sat Mar 14 22:53:12 2009 KakeruUpdateoplevsarm cavity oplev calibrationI finished a calibration of optical levers.

To calibrate oplevs, I locked appropriate
 oplev.pdf 
  1413   Fri Mar 20 15:37:58 2009 KakeruUpdateoplevsarm cavity oplev calibration
I calibrated several oplevs with OSEM signal
as a confirmation of my fitting method the
  
  1434   Thu Mar 26 09:08:18 2009 KakeruUpdateoplevsarm cavity oplev calibrationI uploaded a document about my oplev calibration.
/cvs/cds/caltech/users/kakeru/oplev_calibration/oplev.pdf
  
  1389   Wed Mar 11 21:03:51 2009 Kakeru and KiwamuUpdateIOOPSL angle QPDKakeru and Kiwamu
We placed a QPD on the PSL bench
for PSL angle monitor.
  
  1386   Wed Mar 11 14:51:01 2009 Kakeru, Joe, RobUpdateIOOMC alignmentThis morning, MC alignment was gone and
MC wasn't lock.
We checked old value of pitch, yaw,
  
  1404   Sun Mar 15 21:50:29 2009 Kakeru, Kiwamu, OsamuUpdateComputersSome computers are rebooted We found c1lsc, c1iscex, c1iscey, c1susvme,
c1asc and c1sosvme are dead.
We  turned off all watchdogs
  
  1270   Tue Feb 3 23:44:44 2009 Kakeru, Peter, YoichiUpdatePSLISS unstabilityWe found that one OP-amp used in ISS servo
oscillated in 10 MHz, 100mV.
Moreover, we found another OP-amp
 TFgain.pngTFphase.png 
  1313   Mon Feb 16 21:49:06 2009 Kakeru, RanaUpdateIOOWFSWe centerd the input of WFS QPD.   
  1358   Thu Mar 5 00:06:32 2009 Kakeru, RanaUpdateIOOWFS centeringWe found that the MC REFL image was no longer
round and that the MCWFS DC quadrant spots
were mostly
 IOO_graph.jpg 
  1376   Mon Mar 9 16:54:52 2009 Kakeru, RanaUpdateComputer Scripts / Programstdsdata doesn't workWe confirmed that new tds(/cvs/cds/caltech/apps/linux/tds_090304/)
works well on linux 64, and replaced it to
/cvs/cds/caltech/apps/linux/tds/
  
  1283   Fri Feb 6 23:23:48 2009 Kakeru, YoichiUpdatePSLISS is fixedYoichi and me found that the transfar function
of the current shunt changed with the current
of PA.
 Current_ShuntTF_gain.pngCurrent_ShuntTF_phase.png 
  1391   Wed Mar 11 23:41:33 2009 Kakeru, YoichiUpdateIOOWFS centering We found the MC reflection was distorted
. And WFC beam went to upward of QPD
We recentered WFC beam and these
  
  10776   Wed Dec 10 21:05:56 2014 KateUpdateSEIGuralp briefly powered down Kate & Jenne
About 2:30 this afternoon, we briefly
powered off the Guralp (C1:PEM-SEIS_GUR1_{X,Y,Z})
  
  3431   Tue Aug 17 23:59:46 2010 KatharineUpdateelogMaglev updateKatharine, Sharmila

Update:  
 repulsiveforce.pngOSEMcalibration.pngOSEMslopes.png 
  3100   Wed Jun 23 11:25:14 2010 Katharine and SharmilaUpdateWIKI-40M UpdateMaglevWeekly update

Lab work
  
  3181   Thu Jul 8 17:29:20 2010 Katharine, SharmilaUpdateelog 


 6x 
  3200   Mon Jul 12 21:26:02 2010 Katharine, SharmilaUpdateelogmaglev coilsThe connection between our coil wires and
BNC terminals was pretty awful (soldered
wires broke off 
 P7120276.JPG 
  3234   Fri Jul 16 12:36:00 2010 Katharine, SharmilaUpdateeloglevitationAfter last night's challenge (or inspiration),
we levitated our magnet this morning. 
Since the nice Olympus camera is not currently
 CIMG0649.AVI 
  3256   Wed Jul 21 12:03:14 2010 Katharine, SharmilaUpdateWIKI-40M Updateweekly updateThis past week, we levitated our small
cylindrical magnet (with the flag made from
heat shrink).  Though the levitated
  
  3111   Wed Jun 23 23:55:03 2010 Katharine, Sharmila, Rana, Steve and KiwamuUpdateVACwiped the BSSome unused
optics in the BS chamber were removed. 
  
  5470   Mon Sep 19 21:19:25 2011 KatrinUpdateGreen LockingBroadband photodiode characterizationAnother Hamasutu S3399 photodiode was tested
with the electronic circuit as described
in LIGO-D-1002969-v.
 current_noise_S3399.pdfidet_S3399.pdfS3399_response.pdfcurrent_noise_S3399_v2.pdfidet_S3399_v2.pdf 
  5511   Thu Sep 22 01:05:28 2011 KatrinUpdateGreen LockingNew modulation frequency (Y arm)[Kiwamu / Katrin]
 
On Wednesday, the green light was
  
  5531   Fri Sep 23 17:31:14 2011 KatrinUpdateGreen LockingStray light reduction (Y)I inserted several beam blocks and iris
on the Y arm Green table. There was/is lots
of stray light because a lot of the mirrors
  
  5585   Fri Sep 30 15:22:17 2011 KatrinUpdateGreen LockingWhat happened on green YARM? 
This is a kind
  
  5619   Tue Oct 4 20:34:20 2011 KatrinUpdateGreen Locking7kHz Peak in servo input YARM[Kiwamu, Katrin]
As reported earlier an oscillation
around 7kHz is an the PDH error signal. The
 servoinput.pngservoinput2.png 
  5623   Wed Oct 5 18:31:02 2011 KatrinUpdateGreen LockingExchanged mirror on YARM tableOn the Green YARM end table the second
mirror behind the laser has been exchanged.
Reason: The light is impinging on
  
  5631   Fri Oct 7 17:35:26 2011 KatrinUpdateGreen LockingPower on green YARM tableAfter all realignment is finished, here
are the powers at several positions:
 
 DSC_3496_power.JPG 
  5646   Mon Oct 10 18:53:04 2011 KatrinUpdateGreen LockingMirrors whose angle of incidence is not 45°The angle of incidence of light is for
some mirrors on the YARM end table different
from 45° even though the mirrors are
  
  5657   Wed Oct 12 18:54:02 2011 KatrinUpdateGreen Locking60 Hz oscillation due to broken BNC cableThere was a 60 Hz and 120 Hz oscillation
on the green PDH photo diode output. After
a long search, I could identify that
  
  5658   Wed Oct 12 19:58:32 2011 KatrinUpdateGreen LockingPower splitter is unbalancedThe mini circuit power splitter ZFRSC-42S+
used at the YARM has no balanced output as
it should have according to the data sheet.
  
  5661   Thu Oct 13 20:25:32 2011 KatrinUpdateGreen LockingLPF transfer function YARMIt is a 4th order filter with
cut of frequency of 120 kHz.
 
 designLPF.pngLC_LPF.TIF 
ELOG V3.1.3-