  288   Thu Jan 31 12:39:14 2008 JohnConfigurationGeneralY arm test mass camerasI've adjusted the test mass cameras on the
y arm to make the beam injected through ETMY
more visible.
  
  290   Fri Feb 1 10:43:05 2008 JohnUpdateEnvironmentConstruction workThe boys next door have some [URL=http://dziban.ligo.caltech.edu:40/40m/?mode=full&reverse=0&reverse=1&npp=20&subtext=hammer]bigger
noisier[/URL] toys.
 DSC_0433.JPG 
  293   Fri Feb 1 17:17:05 2008 JohnSummaryPSLMach-Zender tweakingI helped Rob adjust the alignment of the Mach-Zender
to try and reduce any AM on the laser light.
Our goal was to reduce the large offsets
  
  294   Sat Feb 2 14:11:27 2008 JohnSummaryComputersOPTLEVmaster screenI changed the layout of the optlev master
screen. The old version is  /cvs/cds/caltech/medm/old/C1ASC_OPTLEVmaster080202.adl
  
  296   Mon Feb 4 22:01:57 2008 JohnSummaryLSCFibres auxiliary locking - FibersI managed to couple ~75% of the light transmitted
from the y arm, through the fibre, back to
the SP table. I hoped that this would be
  
  304   Sat Feb 9 13:05:48 2008 JohnSummaryIOOPMC camera/ HEPAI replaced the Gig-E camera on the PMC trans
beam. The PZT was close to railing and I
wanted to adjust it. I just did a quick job,
  
  305   Sat Feb 9 13:32:07 2008 JohnSummarySUSAll watchdogs trippedWhen I arrived this afternoon the watchdogs
had tripped on all optics. I reset them and
enabled the coil currents.
  
  315   Wed Feb 13 20:37:11 2008 JohnUpdateLSCFibre locking - FiberSam and I observed fringes in the light reflected
from the Y arm. These fringes are due to
the sidebands and not the carrier. To improve
  
  324   Tue Feb 19 18:28:41 2008 JohnUpdatePEMMore seismic in Baja CaliforniaSteve spotted more activity from the same
quake. 
  
  328   Thu Feb 21 18:29:28 2008 JohnSummaryGeneralHP Network Analyser AnalyzerThe HP 4195A network analyser may be broken,
measurements below 150MHz are not reliable.
Above 150MHz everything looks normal. This
  
  342   Wed Feb 27 22:05:03 2008 JohnUpdateLSCAuxiliary lockingA summary of the status of the auxiliary arm
locking effort.
  
  348   Fri Feb 29 13:51:17 2008 JohnSummaryLSCPD6 responseI checked the response of PD6 using the AM
laser. It looks happy enough.[IMG]elog:348/1[/IMG]
 PD6Attempt3.jpg 
  359   Wed Mar 5 12:35:09 2008 JohnSummaryComputer Scripts / ProgramsPlot photodiode responses in MatLabA matlab function to plot the responses of
photodiodes. There's still plenty of room
for improvement but it should work for all
 PD6DeltaT.jpgPD6.jpgPDbw.jpg 
  360   Wed Mar 5 12:51:48 2008 JohnSummaryLSCInitial Ligo Arm finesse versus lambdaI've taken the coating recipes for the initial
ligo arm cavity from Rana's web page (ligo.caltech/edu/~rana/mat/)
and plotted the finesse as a function of
 FofLambdaLIGOI.jpg 
  367   Mon Mar 10 20:46:41 2008 JohnConfigurationLSCETMY Trans PD & QPDI've placed a 10% reflector in the path from
ETMY to the trans and quadrant photodiodes.
  
  377   Thu Mar 13 18:20:29 2008 JohnUpdateGeneralNew Focus 4003 EOM 29.489MHzI measured the modulation index as a function
of drive power using an OSA. Agrees well
with spec of 0.2 rad/V.
 4003.jpg 
  396   Sun Mar 23 00:56:42 2008 JohnUpdateLSCMore on 3f We ended our last attempt at 3f locking concerned
about the beam size on PD6. I investigated
tonight. The beam was not obviously overfilling
  
  399   Mon Mar 24 20:15:03 2008 JohnSummaryComputersc1susvme2c1susvme2 isn't behaving itself. It keeps
getting out of sync and/or giving a red status
light.
  
  402   Tue Mar 25 15:56:09 2008 JohnUpdateTreasureAssorted picturesSome pictures scavenged from the D40.  D40.pdf 
  405   Wed Mar 26 22:26:15 2008 JohnUpdateComputersc1susvmeI removed the fan and tweaked the timing cables
to see if they were the source of our problems.
I saw no effect. I'm leaving the fan off
  
  503   Thu May 29 15:58:44 2008 JohnSummaryIOOMC realignmentI repeatedly adjusted the yaw of the upper
mirror on the input periscope and re aligned
the MC. With the PRM aligned I tried to optimise
 MC.png 
  536   Tue Jun 17 22:00:53 2008 JohnHowToPSLProblems turning MZ servo on/offWe were unable to toggle the MZ servo on/off
(Blank/Normal) from MEDM. Pushing on the
Xycom board and cables changed the fault
  
  557   Tue Jun 24 15:15:09 2008 JohnSummaryLSCLocking effortsRob, Rana, John

In the past week or so we've been working
 mcl080623.png 
  562   Wed Jun 25 01:30:19 2008 JohnSummaryIOOFrequency noise after the MCI made some (very) rough estimates of the
contribution made to the noise after the
mode cleaner by three sources.
 MC2noise080623.png 
  568   Wed Jun 25 13:56:56 2008 JohnSummaryLockingTuesday night lockingRob, John

Worked to try and reduce the CARM offset
  
  573   Thu Jun 26 12:30:40 2008 JohnSummaryLockingCARM on REFL_DC[COLOR=blue]Idea:[/COLOR]

Try REFL_DC as the error signal for CARM
  
  582   Fri Jun 27 14:36:39 2008 JohnSummaryLocking Rob, Yoichi, John

Some progress last night:
 gettingcloser.png 
  586   Fri Jun 27 19:59:44 2008 JohnUpdateComputersc1iovmeC1susvme2 and C1iovme crashed which sent the
optics swinging and tripped the watchdogs.
  
  588   Sat Jun 28 14:56:44 2008 JohnUpdateComputersini filesIn short, I was editing the ini files yesterday
evening, I didn't e-log it and after some
investigation this afternoon it apears
  
  589   Sat Jun 28 23:23:50 2008 JohnUpdateComputersRebootingAll of the computers are now showing green
lights.
  
  591   Sun Jun 29 11:31:52 2008 JohnSummaryPSLISSI reduced the gain of the ISS (C1: PSL-ISS_VGAGAIN)
from 5dB to 2dB. Any higher and it constantly
saturates.
  
  595   Sun Jun 29 19:53:26 2008 JohnSummaryPSLISS[quote]I reduced the gain of the ISS (C1:
PSL-ISS_VGAGAIN) from 5dB to 2dB. Any higher
and it constantly saturates.[/quote]
  
  596   Sun Jun 29 20:09:40 2008 JohnSummaryIOOmcup and mcdown indicatorsI edited the mcup and mcdown scripts so that
C1IFO_STATE shows when these scripts are
running.
 mcscreen.pngifostate.png 
  598   Mon Jun 30 01:49:06 2008 JohnUpdateIOOMC workI'm in the process of aligning the mode cleaner/
input beam.
  
  601   Mon Jun 30 09:46:15 2008 JohnUpdateIOOMC WFSMC WFS are on. They seem to do some good during
the day.
  
  604   Mon Jun 30 15:08:52 2008 JohnSummaryPSLMZ alignmentI adjusted the alignmnet of the Mach-Zehnder's
two North mirrors (downstream of the EOMs).
 mzalign.png 
  613   Tue Jul 1 12:51:34 2008 JohnSummaryGeneralIFO alignmentRana, Rob, Yoichi, John

The recent computer problems and MZ work
 align080701.png 
  618   Tue Jul 1 21:45:48 2008 JohnUpdatePSLMach Zehnder script and screenI've edited C1: PSL_MACH_ZEHNDER.adl and /cvs/cds/caltech/scripts/PSL/MZ/lockMZ
to reflect the changes described in entry
#616.
  
  625   Wed Jul 2 17:19:03 2008 JohnSummaryComputersop440m - shutdown and restartedAfter 160days op440m was getting a little
slow.
  
  626   Wed Jul 2 18:30:01 2008 JohnUpdateIOOQPD alignmentI aligned the beams on the following QPDs

IP POS
 IOO080702.pngMC080702.png 
  633   Thu Jul 3 16:57:23 2008 JohnSummaryGeneralFSS_RMTEMPThe FSS room temp alarm has been beeping a
lot recently. I altered the FSS_RMTEMP alarm
levels using the
 FSStime.pngFSSalarm.png 
  644   Tue Jul 8 00:14:28 2008 JohnSummaryComputersAlarm handlerRob thought it would be nice to have some
alarms on the cpu loads and FE syncs.
I added all these channels to the alarm handler
  
  648   Tue Jul 8 12:25:54 2008 JohnSummaryPSLISS gain set to 2dB    
  651   Wed Jul 9 12:42:14 2008 JohnUpdateLockingHand off to RF CARMRob, Yoichi, John

Last night we were able to reduce the CARM
 LongLock080709.png 
  653   Wed Jul 9 17:58:19 2008 JohnSummaryGeneralIlluminator alarmsThis morning some time was wasted on alignment
due to the illuminators.
  
  657   Thu Jul 10 23:27:57 2008 JohnMetaphysicsCamerasSecret handshakesRob and I have joined the ranks of the illuminati
and exercised our power.
  
  664   Sun Jul 13 22:39:16 2008 JohnSummaryGeneralEdited medm screens I've edited the FSS and PMC screens so that
red boxes are shown around the appropriate
slider if a gain or offset is not within
  
  665   Mon Jul 14 00:36:19 2008 JohnSummaryPSLSlow sweep of laser temp - PMC PZT responseJohn, Rana

Follow up to # 663
 SlowTsweep.png 
  667   Mon Jul 14 12:43:07 2008 JohnSummaryComputersRestarted fb40m, tpman and c1ass    
  675   Tue Jul 15 12:44:08 2008 JohnSummaryLockingDRFPMI with DC readoutRob, John

Last night, despite suspect alignment, we
  
ELOG V3.1.3-