40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 80 of 341  Not logged in ELOG logo
ID Date Author Typeup Category Subject Text Attachments
  645   Tue Jul 8 08:16:56 2008 steveUpdatePSLPMC problemThe PMC is unhappy. PMC auto locker is not
working.
DC output slider adjust has to be moved from
 pmc.jpg 
  646   Tue Jul 8 10:20:10 2008 steveUpdatePEMHEPA turned onIt is specially important to run the PSL-HEPA
filters when inside counts is peaking at
30,000 counts
 hepa.jpg 
  647   Tue Jul 8 10:26:30 2008 MashaUpdateAuxiliary lockingsetup updatesYesterday I changed one of the beam splitters
in the Mach Zehnder to one with a more stable
mount as to reduce the system's coupling
  
  650   Tue Jul 8 21:58:22 2008 albertoUpdateGeneralSecondaty beam aligned to the IFO beam againYesterday the alignment of the secondary beam
to the IFO was completely lost and today
I had to realign all the optics before I
  
  651   Wed Jul 9 12:42:14 2008 JohnUpdateLockingHand off to RF CARMRob, Yoichi, John

Last night we were able to reduce the CARM
 LongLock080709.png 
  655   Thu Jul 10 14:59:01 2008 robUpdateLockingRF common mode at zero offset[I]rob, john, yoichi[/I]

[SIZE=3][FONT=Comic Sans MS]Last night we
 lock_control_sequence_worked.pngtrendpowerbuild.png 
  656   Thu Jul 10 19:12:07 2008 AlbertoUpdateGeneralabs cavity length measurement experimentYesterday morning, when I started, I found
the IFO beam on a different position and
the beam spot at the AS port looked very
  
  659   Fri Jul 11 09:29:02 2008 steveUpdatePSLthe PMC still hangs upMorning alarms:

PMC high voltage is railing, it's auto locker
 pmc4d.jpg 
  661   Fri Jul 11 23:55:25 2008 alanUpdateLockingRF common mode at zero offset[quote][I]rob, john, yoichi[/I]

[SIZE=3][FONT=Comic Sans MS]Last night we
  
  662   Sat Jul 12 23:28:31 2008 ranaUpdatePSLPMC needs helpAs everyone has noticed recently, the PMC
seems to have a PZT problem. It often zooms
 Untitled.png 
  668   Mon Jul 14 19:15:43 2008 AlbertoUpdateGeneralabs cavity length measurement experimentLately I've been dealing with the alignment
of the interferometer to have a good beam
spot at the AS port. Today the alignment
  
  669   Mon Jul 14 21:34:10 2008 AlbertoUpdateGeneralabs cavity length measurement experiment[quote]Lately I've been dealing with the alignment
of the interferometer to have a good beam
spot at the AS port. Today the alignment
  
  670   Tue Jul 15 09:47:09 2008 steveUpdatePEMlab temps and particlesAll air condtion units were serviced last
Friday.
AC filters are trying to control our particle
 temps24d.jpg 
  672   Tue Jul 15 10:24:57 2008 steveUpdatePSLPMC temp & pzt voltageThe PMC pzt HV was happy with no HEPA temp
stability.
Can we thermally insulate the pmc ?
 pmctemp.jpg 
  674   Tue Jul 15 12:23:22 2008 JenneUpdateGeneralMC2 Watchdog trippedAlberto, Jenne

Mode Cleaner was unlocked.  We checked, and
  
  677   Wed Jul 16 09:27:17 2008 steveUpdateALARMPSL-FSS_RMTEMP alarm is falseMorning alarm sound is good for people who
does not drink coffee.
Our 40m alarm is on every morning.
 frmtemp2y.jpg 
  679   Wed Jul 16 11:00:15 2008 MashaUpdateAuxiliary lockingimproving ADC input for the mach zehnder setup and completely unrelated happeningsFor most of last week, the SURFs + Jenne were
helping Mike and Ken with "stray light control
for
  
  680   Wed Jul 16 11:26:47 2008 Max JonesUpdate This WeekBaffles. 

I got a battery for the magnetometer today
  
  683   Wed Jul 16 16:59:07 2008 AlbertoUpdateGeneralAligmentI think the two beams are aligned again -
they both pass the Faraday, they match at
the irises and all along the optical path
  
  685   Wed Jul 16 17:51:58 2008 MashaUpdateAuxiliary lockinglong measurementI'm taking a measurement on the SR785 spectrum
analyzer at low frequencies, so I'm going
to leave it by the symmetric port table for
  
  686   Wed Jul 16 22:29:05 2008 MashaUpdateAuxiliary lockinglong measurement[quote]I'm taking a measurement on the SR785
spectrum analyzer at low frequencies, so
I'm going to leave it by the symmetric port
  
  688   Thu Jul 17 08:30:15 2008 steveUpdatePSLPMC relocked manuallyThe PMC pzt HV and the servo gain adj. are
railing at max this morning
 pmc4d.jpg 
  689   Thu Jul 17 12:15:21 2008 EricUpdatePSLSwept PMC PZT voltage rangeI unlocked the PMC and swept over C1:PSL-PMC_RAMP's
full range a couple of times this morning.
 The PMC should now be relocked and returned
  
  691   Thu Jul 17 16:39:58 2008 Max JonesUpdateDAQMagnetometer InstalledToday I installed the magnetometer near the
beam splitter chamber. It is located on the
BSC chamber at head height on the inner part
  
  692   Thu Jul 17 20:13:34 2008 YoichiUpdatePSLPMC alignment/mode matching effortI'm working to improve the mode matching of
PMC.
Because I noticed that the beam was hitting
  
  694   Fri Jul 18 16:57:37 2008 JenneUpdateIOOCalibrated MC_FI have calibrated MC_F.  The conversion factor
is 137.49 MHz/count.
 MC_Fcalib.png20080717MC_F-MC_I.pdf 
  695   Fri Jul 18 17:06:20 2008 JenneUpdateComputersComputers down for most of the day, but back up now[Sharon, Alex, Rob, Alberto, Jenne]

Sharon and I have been having trouble with
  
  696   Fri Jul 18 17:12:35 2008 JenneUpdateIOOChecking out the MC Servo Board[Jenne, Max]

One of the things that Rana thinks that might
  
  697   Fri Jul 18 19:15:15 2008 JenneUpdateIOOChecking out the MC Servo Board[quote][Jenne, Max]

I haven't checked to ensure that the MC still
  
  698   Fri Jul 18 19:30:20 2008 MashaUpdateAuxiliary lockingmoving from 40mI will be working in the basement of Bridge
probably starting next week; I moved the
NPRO laser and some of the optics from my
  
  699   Fri Jul 18 19:41:09 2008 YoichiUpdatePSLPMC PZT investigationI measured the HV coming to the PMC PZT by
plugging it off from the PZT and hooking
it up to a DVM.
 Hysteresis.pngStepResponse.png 
  701   Fri Jul 18 23:24:24 2008 robUpdatePSLPMC PZT investigation[quote]I measured the HV coming to the PMC
PZT by plugging it off from the PZT and hooking
it up to a DVM.
  
  702   Sat Jul 19 19:39:44 2008 robUpdatePSLPMC PZT investigation[quote][quote] The 64k is the series resistor
after the PA85, not the modeled resistance
of the PZT itself.[/quote]
  
  704   Mon Jul 21 09:52:05 2008 SharonUpdate Adaptive code changesThanks to Alex, we now save the coefficients
of the adaptive filter every cycle. When
we choose ENABLE: OFF on the MEDM screen,
  
  705   Mon Jul 21 10:00:42 2008 steveUpdatePEMifo room tempFive years of temp trend with 5 C fluctuation.
The campus chilled water supply was upgraded
~ 1 year ago.
 temp5y.jpg 
  706   Mon Jul 21 11:54:00 2008 JenneUpdateGeneralMC Servo BoardI pulled the MC Servo Board again, to check
the components that are on the board, and
compare them with the schematics.  The filters
  
  709   Mon Jul 21 19:48:57 2008 SharonUpdate how tp restart C1ASSHow to restart C1ASS:

1. reboot
  
  711   Tue Jul 22 03:03:22 2008 John, RobUpdatePSLFSS open loop transfer functionWith the common gain slider maxed out the
unity gain frequency is 58kHz.
  
  712   Tue Jul 22 09:24:17 2008 steveUpdatePSLlaser powerLaser power reality of 120 days  power120d.jpg 
  713   Tue Jul 22 11:55:22 2008 ranaUpdatePSLNote from R. Abbott re: the PMCan email from Rich:
[CODE]Your PZT is broken.
  
  714   Tue Jul 22 13:15:14 2008 robUpdatePSLNote from R. Abbott re: the PMC[quote]an email from Rich:
[CODE]Your PZT is broken.
  
  715   Tue Jul 22 13:16:09 2008 John, RobUpdatePSLFSS open loop transfer function[quote]With the common gain slider maxed out
the unity gain frequency is 58kHz.
  
  717   Tue Jul 22 22:11:58 2008 YoichiUpdateLSCX-arm g factor measurementAlberto, Yoichi

We measured the g factor of the X-arm by
  
  718   Tue Jul 22 22:25:31 2008 ranaUpdateLSCLooptickle for existing 40mJohn and I have adapted the Stefan-Looptickle
model of the 40m upgrade to have the parameters
of the old one.
 nb.png 
  720   Wed Jul 23 10:47:05 2008 SharonUpdate Weekly updateThis week I spent some time with Alex who
updated the adaptive code to save the filter's
coeffs all the time, stop when I open the
  
  721   Wed Jul 23 10:49:37 2008 MaxUpdateComputer Scripts / ProgramsWeekly Progress ReportThis week I installed the magnetometer. The
channels seem to be reading correctly. I'm
back to working on noise budget and have
  
  723   Wed Jul 23 13:52:26 2008 SharonUpdate MEDM changesThere is a new MEDM screen now when you go
from c1ass>top>pem.
Instead of having 12 "mini filters" screens
 matrix 
  726   Wed Jul 23 18:42:18 2008 JenneUpdatePSLAlignment of AOM[Rana, Yoichi, Jenne]

Short Version:  We are selecting the wrong
  
  728   Wed Jul 23 22:34:07 2008 YoichiUpdateLSCArm cavity g-factor measurementI tried the same thing as the X-arm to the
Y-arm.
I'm puzzled. I found exactly the same behavior
  
  730   Thu Jul 24 01:27:00 2008 KojiUpdateLSCArm cavity g-factor measurement[quote]I locked the Y-arm and mis-aligned
the end mirror in Yaw until the transmission
power gets half.
  
ELOG V3.1.3-