40m QIL Cryo_Lab CTN SUS_Lab CAML OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 7 of 354  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  1803   Wed Jul 29 11:58:57 2009 AlbertoUpdatePSLMC not lockingThis morning I found the Mode Cleaner unlocked.
I check the sliders for the mirrors
bias and they have not changed. Also the
  
  1817   Mon Aug 3 01:08:20 2009 AlbertoUpdatePSLMC unlockedFriday afternoon the mode cleaner got unlocked.
Then some adjustment of the MC1 bias sliders
locked it again. The driftmon showed the
  
  1818   Mon Aug 3 12:57:09 2009 AlbertoUpdatePSLMC unlocked


   
        
            
  
  1832   Wed Aug 5 09:25:57 2009 AlbertoDAQComputersfb40m is upFB40m up and running again after restarting
the DAQ.
  
  1837   Wed Aug 5 15:57:05 2009 AlbertoConfigurationComputersPMC MEDM screen changedI added a clock to the PMC medm screen.
I made a backup of the original file
in the same directory and named it *.bk20090805
  
  1841   Thu Aug 6 09:22:17 2009 AlbertoDAQGeneralcan't get trends


   
        
            
  
  1853   Fri Aug 7 11:39:13 2009 AlbertoUpdatePSLMZ AlignmentFor the last couple of days we've been
trying to find the cause that is preventing
us to get more than 0.85 for the arm power.
After
  
  1855   Fri Aug 7 14:31:39 2009 AlbertoUpdatePSLDAQ REstartedFor some reason a few minutes ago the FB
DAQ crashed and I had to restarted.
  
  1877   Mon Aug 10 16:41:31 2009 AlbertoConfigurationPSLPMC VisibilityAlberto, Rana
lately we've been trying to better
understand what's preventing the arm power
  
  1893   Wed Aug 12 15:02:33 2009 AlbertoConfigurationComputerselog restartedIn the last hour or so the elog crashed.
I  have restarted it.
  
  1936   Mon Aug 24 10:43:27 2009 AlbertoOmnistructureComputersRFM Network FailureThis morning I found that all the front
end computers down. A failure of the RFM
network drove all the computers down.
  
  1944   Tue Aug 25 21:26:12 2009 AlbertoUpdateComputerselog restartedI just found the elog down and I restarted
it.
  
  1945   Tue Aug 25 21:36:28 2009 AlbertoUpdatePSLreference cavity temp box temporarly out of order 
 Is that the reason of the PSL
craziness tonight? See attachment.
 2009-08-25_PSLtrend.png 
  1949   Wed Aug 26 15:42:17 2009 AlbertoUpdatePSLreference cavity temp box temporarly out of order

    
        
  
  1951   Wed Aug 26 16:11:41 2009 AlbertoUpdatePSLreference cavity temp box temporarly out of orderIt turned out that half an hour was too
long. In less than that the reference cavity
temperature passed the critical point when
  
  1953   Wed Aug 26 16:35:03 2009 AlbertoConfigurationPSLPSL reference cavity temperature box modificationsBasically, in addition to the replacement
of the resistors with metal film ones, Peter
replaced the chip that provides a voltage
  
  1966   Thu Sep 3 23:41:32 2009 AlbertoConfigurationLSCPOX (PD3) alignedToday I aligned the beam to PD3 (POX) since
Steve had moved it.
The DC power read 1.3mV when the
  
  1969   Mon Sep 7 23:18:01 2009 AlbertoUpdateLockingSome locking attemptsTried
to lock the interferometer but arm power
didn't get over 65.
  
  1972   Tue Sep 8 12:26:16 2009 AlbertoUpdatePSLConnection of the RC heater's power supply replacedI
have replaced the temporary clamps that were
connecting the RC heater to its power supply
  
  2044   Fri Oct 2 17:00:06 2009 AlbertoUpdateGeneral40m Update - Requirements on the 5x Frequency MultiplierHere's the gist of the requirements on
the 5x frequency multiplier for the upgrade
(see attachemnt - despite the preview down
 DesignOfTheMultiplier1-14-15.pdf 
  2049   Mon Oct 5 09:31:05 2009 AlbertoFrogsPSLPSL laser accidentally turned offAlberto, Steve,
While I was moving a cart near by
the PSL table I pushed the red emergency
  
  2053   Mon Oct 5 14:37:29 2009 AlbertoUpdateABSLAbsolute Length Meaasurement NPRO is onIn the revival of the experiement length
measurement for the recycling cavities, I
turned the auxiliary NPRO back on. The shutter
  
  2108   Sun Oct 18 15:46:08 2009 AlbertoConfigurationGeneralAntique, unused QPD removed from the AS table Inspecting the AS table to make an inventory
of the photodiodes in use around the interferometer,
I found a mysterious photodetector hiding
  
  2129   Wed Oct 21 15:07:45 2009 AlbertoUpdateWIKI-40M UpdatePhotodiodes' configuration for the UpgradeI uploaded on the Wiki (here)
the results of an inventory over our current
PDs, a list of the new ones that we're going
  
  2131   Wed Oct 21 17:12:30 2009 AlbertoUpdateelogBrowser context menu enabled on the Elog under HTM editing modeOn behalf of Steve and of the rest of the
not-native-English community at the 40m willing
to have their browser's spell checker working
  
  2174   Wed Nov 4 16:49:32 2009 AlbertoUpdateLSCArm Cavity Finesse MeasurementI'm going to work on the X arm to measure
the arm cavity finesse.
The idea is to measure the cavity
 DSC_0952.JPG 
  2175   Wed Nov 4 18:35:19 2009 AlbertoUpdateLSCArm Cavity Finesse Measurement

    
        
  
  2176   Wed Nov 4 21:46:18 2009 AlbertoUpdateLSCArm Cavity Finesse Measurement

    
        
  
  2177   Wed Nov 4 23:17:51 2009 AlbertoUpdateLSCX Arm Cavity transfer FunctionI measured the transfer function between
MC_TRANS and TRX and I'm attaching the result.
 ArmCavityTF02.png 
  2184   Thu Nov 5 19:25:11 2009 AlbertoUpdateLSCX Arm Cavity transfer Function


   
        
            
 PDA255CalibrationTF03.png 
  2185   Thu Nov 5 22:30:09 2009 AlbertoUpdateLSCX Arm Cavity Transfer FunctionIt seems that just repeating the measurement
was enough to get a good transfer function
of the x arm cavity. Here's what I got.
 XarmTF01.png 
  2186   Thu Nov 5 23:09:34 2009 AlbertoUpdateLSCY Arm Cavity Transfer FunctionAs for the X Arm, this the transfer function
I measured for the Y arm cavity.
 YarmTF01.png 
  2187   Fri Nov 6 00:23:34 2009 AlbertoConfigurationComputersElog just rebootedThe elog just crashed and I rebooted it   
  2188   Fri Nov 6 00:24:06 2009 AlbertoUpdateLSCY Arm Cavity Transfer Function

    
        
 YarmTF02.png 
  2189   Fri Nov 6 00:40:29 2009 AlbertoUpdateLSCEverything put back as it wasI disconnected the setup for the arm cavity
TF measurement. I opened the scitation switch
on the ISS medm screen. I reconnected the
  
  2204   Sun Nov 8 14:18:25 2009 AlbertoUpdateSUSETMY Watchdogs trippedThis afternoon I re-enabled the ETMY coils
after I found that the watchdogs for the mirror had
  
  2205   Sun Nov 8 22:50:29 2009 AlbertoUpdateASCIFO AlignmentTonight I aligned the IFO by running the
scripts one by one.
SRC was far off and I had to align
  
  2208   Mon Nov 9 11:11:19 2009 AlbertoConfigurationLSCMC2 Watchdogs trippedThe MC2 watchdogs tripped. I just restored
them.
I also had to relock the MZ and then
  
  2209   Mon Nov 9 11:14:57 2009 AlbertoUpdateABSLStarted working on the PSL tableI'm working on the PSL table to set up
the PLL setup for the AbsL experiment.
  
  2210   Mon Nov 9 12:09:10 2009 AlbertoOmnistructureEnvironmentBNC Cable Laid Down from South End to East VErtexI laid down the floor a BNC cable from
the Y End table to the BNC Chamber. The cable
runs next to the east wall.
 DSC_0986.JPG 
  2211   Mon Nov 9 13:17:07 2009 AlbertoConfigurationABSLNPRO onI turned the auxialiary NPRO for the AbsL
Experiment on. Its shutter stays closed.
  
  2213   Mon Nov 9 13:26:19 2009 AlbertoOmnistructureEnvironmentTidying up BNC cables rack around the labWe have thousands of miles of BNC cables
in the lab but we still don't find one when
we need it. I decided to solve the problem.
 DSC_0987.JPG 
  2214   Mon Nov 9 14:53:47 2009 AlbertoOmnistructureEnvironmentTidying up BNC cables rack around the labThis would be a good trial once you put
the label "BNC only" on
the wall.
  
  2217   Mon Nov 9 15:11:02 2009 AlbertoUpdateLSCEverything put back as it was


   
        
            
  
  2219   Mon Nov 9 16:32:36 2009 AlbertoFrogsEnvironmentShot of the white board yesterday before erasingYesterday Rana and I needed some room on
the white board in the Control Room. We had
to erase some of the stuff present on the
 DSC_0980.JPGDSC_0980.JPG 
  2220   Mon Nov 9 18:27:30 2009 AlbertoFrogsComputersOMC DCPD Interface Box Disconnected from the power SupplyThis afternoon I inadvertently disconnected
one of the power cables coming from the power
supply on the floor next to the OMC cabinet
  
  2226   Tue Nov 10 13:02:36 2009 AlbertoUpdateLSCX and Y Arm Cavity Poles MeasurementFrom fitting the arm cavity transfer functions
I got the following values for the cavity
pole frequencies.
 SummaryOfFits.pdfCodeAndData.tar 
  2227   Tue Nov 10 17:01:33 2009 AlbertoConfigurationIOOc1ioovme and c1iool0 rebooted This afternoon, while I was trying to add
the StochMon channels to the frames, I rebooted
the c1ioovme and c1iool0.
  
  2228   Tue Nov 10 17:49:20 2009 AlbertoMetaphysicsComputersTest Point Number MappingI found this interesting entry by Rana
in the old (deprecated) elog : here
I wonder if Rolf has ever written
  
  2229   Tue Nov 10 19:19:57 2009 AlbertoUpdateABSLRotated polarizer on the PSL table, along the MC input pick off beam Aligning the beam for the PLL of the AbsL
Experiement I rotated the polarizer along
the path of the MC Input pick off beam (=
  
ELOG V3.1.3-