40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 7 of 341  Not logged in ELOG logo
ID Date Author Typeup Category Subject Text Attachments
  823   Mon Aug 11 12:42:04 2008 josephbConfigurationComputersContinuing saga of c1susvme1Coming back after lunch around 12:30pm, c1susvme1's
status was again red.  After switching off
watchdogs, a reboot (ssh, su, reboot) and
  
  824   Mon Aug 11 13:59:23 2008 josephbConfigurationComputers While poking around the crate, I noticed an
error light on one of the c1susvme2 related
boards was lit, while the corresponding light
  
  825   Mon Aug 11 15:07:49 2008 josephbConfigurationComputersProcyon aka fb40m switched to new switchI've connected Procyon to the Prosafe 24 port
switch with a new, labeled Cat6 cable.  Quick
tests with dataviewer shows that its working.
  
  828   Tue Aug 12 12:21:13 2008 josephbConfigurationCamerasVariation in fit over 140 images for GC650 and GC750Used matlab to calculate Gaussian fits on
145 GC650 images and 142 GC750 images.  These
were individual images (no averaging) looking
  
  831   Wed Aug 13 17:00:59 2008 steveConfigurationSUSBS sat amp removedThe PRM sat amp is broken. Ben is working
on it.
The BS sat amp was removed from the BS sus
  
  836   Thu Aug 14 19:08:14 2008 YoichiConfigurationSUSFree swing measurement going onI started free swinging spectra measurement
of all the suspensions now Aug 14 19:05 (PDT).
The watch dogs are all shutdown. Please do
  
  839   Fri Aug 15 11:52:32 2008 josephbConfigurationCamerasMulti-computer display and recording of digital camera outputThrough the magic of gstreamer, I've been
able to live play on one machine, compress
the image, send it to another machine via
  
  843   Fri Aug 15 19:32:49 2008 steveConfigurationVACpumpdown completeI have just reached vacuum normal. The maglev
peaked at 49.8C body temp with aux fan on
at 3.2 Torr
 pdprm.jpg 
  844   Mon Aug 18 08:07:10 2008 YoichiConfigurationSUSSuspension free swingingI've started a free swinging measurement of
OSEM spectra now. Please leave the watchdogs
untouched.
  
  847   Mon Aug 18 15:32:18 2008 josephbConfigurationCamerasHow to multicast with gstreamer and Gige CamerasIn order to get multicasting to work, one
simply needs to understand the address scheme.
  
  852   Tue Aug 19 13:34:58 2008 josephbConfigurationComputersSwitched c1pem1, c0daqawg, c0daqctrl over to new switchesMoved the Ethernet connections for c1pem1,
c0daqawg, and c0daqctrl over to the Netgear
Prosafe switch in 1Y6, using new cat6 cables.
  
  857   Tue Aug 19 19:14:17 2008 YoichiConfigurationDAQFixed C1:IOO-MC_RFAMPDDCYoichi, Rob

C1:IOO-MC_RFAMPDDC, which is a PD at the
  
  865   Thu Aug 21 10:24:20 2008 steveConfigurationSAFETYlaser safe mode conditionThe MOPA and PSL shutters are closed.
Manual beam blocks are in place.
Enclosure interlock is enabled.
  
  866   Thu Aug 21 16:28:59 2008 steveConfigurationSAFETYsafety glasses required I just opened the MOPA shutter so PA is warming
up.
  
  880   Mon Aug 25 14:42:09 2008 EricConfigurationCamerasETMX Digital CameraI changed the lens on the camera looking at
the ETMX to a 16mm, 1:1.4 zoom lens.  This
is in preparation to measure a couple parameters
  
  883   Mon Aug 25 21:15:23 2008 ranaConfigurationLSCaux NPRO off[FONT=Comic Sans MS][COLOR=purple]Looks like
no one has used the Lightwave NPRO on the
AS table after Koji left, so I turned it
  
  884   Tue Aug 26 09:04:59 2008 ranaConfigurationPSLPMC Servo Board: Out for RepairsI've started modifying our PMC board to bring
it up to the 21st century - [B][COLOR=blue]leave
the screen alone[/COLOR][/B] or else you
  
  887   Tue Aug 26 15:06:16 2008 steveConfigurationVACrga scanPumpdown 66 PRM-maglev vac normal -day 11
short form: pd66PRM-m-d11
 RGA-0808260125.png 
  893   Thu Aug 28 18:56:14 2008 ranaConfigurationPSLbeam block distortedThere was a beam block after the Mach Zender.
Who or what put this there?
  
  896   Fri Aug 29 10:20:32 2008 YoichiConfigurationPSLbeam block distorted[quote]There was a beam block after the Mach
Zender. Who or what put this there?
  
  897   Fri Aug 29 11:01:49 2008 josephbConfigurationComputersAttempt to change a channel gain in ICS-110BAs noted earlier by Rana, I was playing around
with the /cvs/cds/caltech/chans/daq/C1IOOF.ini
file with help from Rob.  I had made a backup
  
  899   Fri Aug 29 12:41:26 2008 josephb, EricConfigurationComputersMore front ends moved to new networkUsed Cat6 cables to finish moving all the
front ends in 1Y4 and 1Y5 over to the new
GigE network switches, specifically to the
  
  902   Fri Aug 29 16:35:18 2008 YoichiConfigurationPSLbeam block distorted[quote]There was a beam block after the Mach
Zender. Who or what put this there?
  
  903   Fri Aug 29 17:39:25 2008 ranaConfigurationPSLPMC: ADC ChannelsThe attached PNG shows the PMC error and controls
signals with no calibration.
 mcf.png 
  906   Sat Aug 30 13:28:01 2008 ranaConfigurationPSLPMC: List of changesThis is a list of changes made to the PMC
board while we had it out for modifying the
notch:
  
  908   Mon Sep 1 19:23:17 2008 YoichiConfigurationPSLFSS on an auxiliary loopSummary: The FSS is now temporarily disabled.
Naturally, the MC won't lock. I will fix
it tomorrow morning.
  
  910   Tue Sep 2 09:58:42 2008 YoichiConfigurationPSLFSS on an auxiliary loop[quote]Summary: The FSS is now temporarily
disabled. Naturally, the MC won't lock. I
will fix it tomorrow morning.
  
  913   Tue Sep 2 22:43:16 2008 YoichiConfigurationPSLUpdated FSS open loop TFSince the LO level of the FSS servo was too
low, I replaced the RF oscillator board with
a combination of
 OPLTF.png 
  915   Wed Sep 3 18:43:19 2008 YoichiConfigurationElectronicsTwo more active probesI found two active probes, an HP41800A and
a Tektronix P6201.
Thanks John for telling me you saw them before.
 Tektronix-P6201-active-probe.pdf 
  916   Wed Sep 3 18:45:01 2008 AlbertoConfiguration PD3 gainAlberto, Yoichi,

We found that the PD3 servo was unstable
  
  922   Thu Sep 4 11:33:25 2008 josephb, Eric, JenneConfigurationComputersAttempt to increase gain for C1:PSL-ISS_INMONPD_F via 110BWe were attempting to increase the gain on
the channel C1:PSL-ISS_INMONPD_F in preparation
to do a scan of the PMC at very low input
  
  925   Thu Sep 4 16:24:56 2008 ranaConfigurationComputersAttempt to increase gain for C1:PSL-ISS_INMONPD_F via 110B[quote]We were attempting to increase the
gain on the channel C1:PSL-ISS_INMONPD_F
in preparation to do a scan of the PMC at
  
  930   Thu Sep 4 18:02:34 2008 rana, josephbConfigurationPEMAccelerometer gains increased by 10[COLOR=chocolate][SIZE=3]We increased the
Accelerometer gains by 10 by modifying the
C1ADCU_PEM.ini file.[/SIZE][/COLOR]
 acc.png 
  932   Fri Sep 5 09:56:14 2008 josephb, EricConfigurationComputersFunny channels, reboots, and ethernet connections1) Apparently the I00-ICS type channels had
gotten into a funny state last night, where
they were showing just noise, exactly when
  
  937   Mon Sep 8 15:38:57 2008 YoichiConfigurationPSLPOY RF amp is back to its original taskI temporarily fixed the busted ZHL-32A RF
amplifier's power connector by simply soldering
a cable to the internal circuit and pulling
  
  941   Thu Sep 11 11:29:14 2008 josephbConfigurationComputersFinal netgear switch in place in 1Y2I've placed the final (of 4) Netgear prosafe
24 port switch at the very top of 1Y2.  At
that location, there are no holes left to
  
  948   Mon Sep 15 14:00:52 2008 josephbConfigurationComputers1Y9 Hub and C1ascThe 1Y9 switch is now using a labeled Cat6
cable in cable trays to connect to the main
switch in the offices.  In addition, the
  
  949   Tue Sep 16 10:57:45 2008 YoichiConfigurationPEMParticle counter gainSummary:
Since we reduced the integration time of
the particle counter by a factor of 10, we
  
  950   Tue Sep 16 13:04:22 2008 YoichiConfigurationPEMC1:PSL-FSS_RMTEMP alarm level changedAt the request of Steve, I modified the HIGH
value of C1:PSL-FSS_RMTEMP from 21.27 to
23.0.
  
  951   Tue Sep 16 16:47:01 2008 peteConfigurationPSLPrototype FSS reference installedAfter verifying output, I installed the new
prototype 21.5 MHz FSS reference (Wenzel
crystal oscillator and ZHL-2 amp).  Yoichi
  
  952   Wed Sep 17 12:55:28 2008 robConfigurationIOOMC lengthI measured the mode cleaner length last night:

[code]
  
  954   Wed Sep 17 13:43:54 2008 YoichiConfigurationPSLRC sweep going onI'm doing a cavity sweep of the RC. Please
leave the IFO untouched until the meeting
is over.
  
  957   Wed Sep 17 15:22:31 2008 YoichiConfigurationPSLRC sweep going on[quote]I'm doing a cavity sweep of the RC.
Please leave the IFO untouched until the
meeting is over.[/quote]
  
  959   Wed Sep 17 17:58:35 2008 YoichiConfigurationPSLRC sweep going onThe cavity sweep is done. The IFO is free
now.
  
  965   Thu Sep 18 14:36:54 2008 josephbConfigurationComputersName server and EpicsThe problems Rob was experiencing last night
was due to part of the setup (or rather testing
of the setup) of the new nameserver running
  
  973   Fri Sep 19 11:21:45 2008 josephbConfigurationComputersNameserver and RosalbaI tried modifying the nsswitch.conf file to
include going to dns in addition to local
files for everything (services, network,
  
  980   Mon Sep 22 21:30:06 2008 ranaConfigurationPSLbad FSSThe MC refl power was going up and the FSS
PC drive was so large that I had to turn
up the FSS
 DAQ.png 
  982   Mon Sep 22 22:24:19 2008 ranaConfigurationPSLbad FSS[quote]The MC refl power was going up and
the FSS PC drive was so large that I had
to turn up the FSS...[/quote]
  
  986   Tue Sep 23 15:28:06 2008 peteConfigurationPSLnew 21.5 MHz FSS reference installedThe new 21.5 MHz FSS reference is now installed
in the rack with the 7 Sorensen PS.  Both
outputs give 18.7 dBm.  The MC seems happy.
 fss_ref_001.jpgfss_ref_013.jpg 
  988   Wed Sep 24 19:13:06 2008 ranaConfigurationComputer Scripts / Programsupdatedb & locate: megatron & rosalbaI ran [I]updatedb[/I] as root today on megatron
and rosalba just before the meeting. 
It finished at ~14:10 on both machines so
  
ELOG V3.1.3-