40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 78 of 344  Not logged in ELOG logo
    Reply  Thu Jan 19 16:36:35 2017, ericq, Update, Computer Scripts / Programs, nodus web apache simlinks too soft 



Quote:



EQ: https://nodus.ligo.caltech.edu:30889/FE is
live
Entry  Wed Mar 1 16:00:41 2017, gautam, Update, Computer Scripts / Programs, Matlab R2016b installed 
Since it would be nice to have the latest version of Matlab, with all its swanky new features (?), available on the control room computers and Optimus,
I downloaded Matlab R2016b and activated it with the Caltech Campus license. I installed it into 
    Reply  Wed Mar 8 18:18:51 2017, johannes, Update, Computer Scripts / Programs, loss script 
I started a loss script on Donatella that will scan the beam spot across ETMY, recording the reflected power from the arm via the networked scope at
the AS port until later tonight (should be done by 9 pm). ITMX is currently strongly misaligned for this, but can be restored with the saved values. I
mostly adapted the mapping scipts for the scope readout but still have to iron out a few kinks, which is why I'm running this test. In particular,
    Reply  Thu Mar 9 22:28:11 2017, johannes, Update, Computer Scripts / Programs, loss script 
loss map script running on Rossa that moves the beam on ETMX. Yarm was misaligned for this, most recent PIT and YAW settings were saved beforehand. This
will take until late at night, I estimate 2-3 am.




    Reply  Fri Mar 10 11:37:25 2017, gautam, Update, Computer Scripts / Programs, loss script 
This was still running at ~9.30am today morning, at which point I manually terminated it after confirming with Johannes that it was okay to do so. Judging
by the StripTool traces in the control room, the mode cleaner remained locked for most of the night, there should be plenty of usable data...

Note that I re-aligned the Y-arm (to experiment further with photo-taking)
    Reply  Fri Mar 10 19:48:56 2017, johannes, Update, Computer Scripts / Programs, loss script 
Loss script running again, on Pianosa this time. Due to an oversight in the code the beam wasn't actually moved across ETMY last night. This time
I confirmed that the correct offset value is written as a demodulation parameter to the correct mirror degree of freedom. Script will probably run through
the night. Yarm is currently misaligned but previous alignment was saved.
    Reply  Sat Mar 11 20:11:58 2017, johannes, Update, Computer Scripts / Programs, loss script 
Yarm script running on Pianosa. Still working on visualization of the ETMX lossmap.




Quote:



Loss script running again,
Entry  Sun Apr 2 23:14:30 2017, rana, Update, Computer Scripts / Programs, nodus update/upgrade/reboot 
I just did remote apt-get update, apt-get upgrade, and then reboot on nodus. ELOG started up by itself.
Entry  Mon May 15 19:21:04 2017, Koji, Update, Computer Scripts / Programs, FSSslow / MCautolocker restarted 
It seems that FSS slow servo stopped working.

I found that megatron was restarted (by Rana, to finish an apt-get upgrade)
on ~18:47 PDT today.
Entry  Thu May 25 16:42:41 2017, jigyasa, Update, Computer Scripts / Programs, Making pylon installation on shared directory 
I have been working on interfacing with the GigE’s. I went through Joe Be’s paper and the previous elogs and verified that the code files
are installed.

I then downloaded and extracted a copy of the Pylon software onto my home directory on Allegra. Gautam helped me find installation instructions
    Reply  Thu May 25 18:37:11 2017, jigyasa, Update, Computer Scripts / Programs, Making pylon installation on shared directory 
Gautam helped me execute the commands mentioned above and Pylon has now been installed on the shared directory. We extracted the pylon installation
from Johannes's directory to the shared drive and executing the command tar –C /opt/rtcds/caltech/c1/scripts/GigE –xzf pylon SDK*.tar.gz
created an unzipped pylon5 folder in /scripts. The ./setup-usb.sh set up the udev rules for the GigE.
Entry  Wed May 31 14:23:42 2017, jigyasa, Update, Computer Scripts / Programs, Establishing the EPICs channels for the GigE 
To set up the EPICs channels for the GigE, Gautam and I followed the steps in the elog by him  8957
.

We copied the 11 required channels from scripts/GigE/SnapPy/example_camera.db to c1cam.db that we created, however due to conflicts with
Entry  Fri Jun 9 16:37:29 2017, jigyasa, Update, Computer Scripts / Programs, OpenCV installation 
OpenCV 3.1.0 has been installed by following the commands locally on Donatella

git clone https://github.com/Itseez/opencv.git
cd opencv
Entry  Thu Jun 15 18:56:31 2017, jigyasa, Update, Computer Scripts / Programs, MC2 Pitch-Yaw offset 
A python script to randomly vary the MC2 pitch and yaw offset and correspondingly record
the value of MC transmission has been started on Donatella in the control room and should run for a couple of hours
overnight. 
Entry  Mon Jun 19 18:32:18 2017, jigyasa, Update, Computer Scripts / Programs, Software Installation for image analysis 
The IRAF software from the National Optical Astronomy Observatory has been installed locally on Donatella(for testing) following the instructions listed
here at http://www.astronomy.ohio-state.edu/~khan/iraf/iraf_step_by_step_installation_64bit
This is a step towards "aperture photometry" and would help identify point scatterers in the images of the test masses.
    Reply  Mon Jun 19 18:41:12 2017, jigyasa, Update, Computer Scripts / Programs, MC2 Pitch-Yaw offset 
The previous run of the script had produced some dubious results!

The script has been modified and now scans the transmission sum for a longer duration to provide a better estimate on the average transmission.
The pitch and yaw offsets have been set to the values that were randomly generated in the previous run as this would enable comparison with the current
    Reply  Tue Jun 20 17:44:12 2017, jigyasa, Update, Computer Scripts / Programs, MC2 Pitch-Yaw offset 
The script didn't run properly last night, due to an oversight of variable names! It's been started again and has been running for half an hour
now.




Entry  Fri Jun 23 02:43:43 2017, Kaustubh, HowTo, Computer Scripts / Programs, Taking Measurements From AG4395A Test_Files_and_Code.zipBode_Plot_with_Error_Bands.pdf
Summary:

I have written a code(a basic one which needs a lot of improvements, but still does the job) for taking multiple measurements from the AG4395A.
I have also written a separate code for plotting the data taken from the previoius code along with the error bars upto 1 standard deviation.
Entry  Fri Jun 23 02:55:18 2017, Kaustubh, Update, Computer Scripts / Programs, Script Running 
I am leaving a script running on the Pianoso for the night. For this purpose, even the AG4395A is kept on. I'll see the result of the script
in the morning (it should be complete by then). Just check so before fiddling with the Analyzer.

Thank you.
    Reply  Tue Jun 27 18:47:49 2017, jigyasa, Update, Computer Scripts / Programs, MC2 Pitch-Yaw offset 
The values generated from the script were analyzed and a 3D scatter plot in addition to a 2D map were plotted. 

Yesterday, Rana pointed me to another method of collecting and analyzing the data. So I worked on the code today and have left a script (MC2rerun.py) running
on Ottavia which should run overnight.
Entry  Thu Jun 29 00:13:08 2017, Kaustubh, Update, Computer Scripts / Programs, Transfer Function Testing Correlation_Plot.pdf2x100_Test_Files_and_Code_and_Correlation_Files.zip
In continuation to my previous posts, I have been working on evaluating the data on transfer function. Recently, I have calculated the correlation values
between the real and imaginary part of the transfer function. Also I have written the code for plotting the transfer function data stream at each
frequency in the argand plane just for referring to. Also I have done a few calculations and found the errors in magnitude and phase using those in the
    Reply  Thu Jun 29 10:04:18 2017, jigyasa, Update, Computer Scripts / Programs, MC2 Pitch-Yaw offset 
The script is being executed again, now.




Quote:



I worked on the code
Entry  Mon Jul 10 17:13:21 2017, jigyasa, Update, Computer Scripts / Programs, Capture image without pylon GUI 
Over the day, I have been working on a C++ program to interface with Pylon to capture images and reduce dependence on the Pylon GUI. The program uses
the Pylon header files along with opencv headers. While ultimately a wrapper in python may be developed for the program, the current C++ program at, 

/users/jigyasa/GigEcode/Grab/Grab.cpp when compiled as
Entry  Mon Jul 10 21:31:15 2017, Kaustubh, HowTo, Computer Scripts / Programs, Details on Cavity Scan Analysis Attachments.zip
Summary:

The following elog describes the procedure followed for generating a sample simulation for a cavity scan, fitting
an actual cavity scan and calculating the relevant paramaters using the cavity scan and fit data.
Entry  Thu Jul 13 16:10:34 2017, Kaustubh, Summary, Computer Scripts / Programs, Cavity Scan Simulation Code 
The code to produce a cavity scan simulation and then fitting the data and re-evaluating the initiallt set parameters can
be found in this git repo.
Entry  Fri Jul 21 19:44:58 2017, Naomi, Summary, Computer Scripts / Programs, Using PyKat to run Finesse 
I have been working on using PyKat to run Finesse. There appear to be several ways to run an equivalent simulation using Finesse:

1: .kat only

Run a .kat file directly from the terminal. For example, if in the directory containing the Finesse kat.ini file, run the command ‘./kat
Entry  Wed Sep 6 01:09:11 2017, johannes, Update, Computer Scripts / Programs, New set of loss measurements XARM_20170905.pdfYARM_20170905.pdf
I stumbled upon a faster way to stream data from the TDS3014 oscilloscopes
to disk, which speeds the loss measurements up by a lot:  ftp://sprite.ssl.berkeley.edu/pub/sharris/MAVEN_LPW_Preamp/109_TDS3014B_control/tds3014b.py
This convenient(!) set of scripts contains a function that parses the scope's native binary format, for which the acquisition of 1 screenful
    Reply  Mon Sep 11 12:56:40 2017, johannes, Update, Computer Scripts / Programs, lossmap attempts 
I was trying to get a lossmap measurement over the weekend but had some trouble first with the IMC and then with the PMC.

For the IMC: It was a bit too misaligned to catch and maintain lock, but I had a hard time improving the alignment by hand. Fortunately, turning
on the WFS quickly once it was locked restored the transmission to nominal levels and made it maintain the lock for longer, but only for several minutes,
    Reply  Mon Sep 18 15:00:15 2017, rana, gautam, Frogs, Computer Scripts / Programs, gateway PWD change 
We implemented the post-SURF-season
nodus password change today.

New password can be found at the usual location.
    Reply  Sun Sep 24 20:47:15 2017, rana, Update, Computer Scripts / Programs, RF TF Uncertainties TFAG4395A_21-09-2017_115547_FourSquare.pdfTFAG4395A_21-09-2017_115547.tgz
I have made several changes to Craig's script for better pythonism. Its more robust with different libraries and syntaxes and makes a tarball by
default (w/o a command line flag). These kinds of general util scripts will be going into a general use folder in the git.ligo.org/40m/ team area so that
it can be used throughout the LSC.
    Reply  Mon Sep 25 17:56:33 2017, johannes, Update, Computer Scripts / Programs, transmitted power during lossmap 
I had to do a reboot + burt restore of c1psl today. It was unresponsive and I couldn't get the PMC to lock. I also had to slightly realign the PMC,
and the IMC was too misaligned for the autolocker to catch lock. Adjusting it manually, it was predominantly MC1 PIT that was off. The YARM locked on a
10 mode and had to be aligned manually as well.
Entry  Thu Dec 7 11:14:37 2017, johannes, HowTo, Computer Scripts / Programs, Lots of red on the FE status screen 22.png
Since we're getting ready to put the replacement slow DAQ for c1auxex in I wanted to bring the IFO back to operating condition after the PMC hasn't
been locked for days. Something seems wrong with the CDS system though, many of the frontent models have red background and don't seem to be responsive.
I followed the instructions laid out in https://wiki-40m.ligo.caltech.edu/Computer_Restart_Procedures.
    Reply  Thu Dec 7 15:02:37 2017, Koji, HowTo, Computer Scripts / Programs, Lots of red on the FE status screen DSC_0552.JPG
Once a realtime machine was rebooted, it did not come back. I suspect that the diskless hosts have a difficulty to boot up.
    Reply  Thu Dec 7 15:46:31 2017, johannes, HowTo, Computer Scripts / Programs, Lots of red on the FE status screen 04.png
[Koji, Johannes]

The issue was partially fixed and the interferometer is in workable condition now.

What -probably- fixed it was restarting the dhcp server on chiara
Entry  Wed Jan 10 14:17:57 2018, johannes, Configuration, Computer Scripts / Programs, autoburt no longer making backups 
I was looking into setting up autoburt for the new c1auxex2 and found that it stopped making automatic backups for all machines after the beginning of
the new year. There is no 2018 folder (it
was the only one missing) in /opt/rtcds/caltech/c1/burt/autoburt/snapshots and the /latest/
    Reply  Wed Jan 10 15:25:43 2018, johannes, Configuration, Computer Scripts / Programs, autoburt making backups again 



Quote:



I manually created the /opt/rtcds/caltech/c1/burt/autoburt/snapshots/2018/ directory. Maybe this
fixes the hickup? Gotta wait about 30 minutes.
Entry  Fri Feb 2 23:28:13 2018, Koji, Update, Computer Scripts / Programs, netgpib data missing / PROLOGIX yellow box (crocetta) not working 
I could not understand why 'netgpibdata' scripts are missing in "scripts/general" folder on pianosa... Where did they go???

Also, I found that the PROLOGIX GPIB-LAN controller for crocetta (192.168.113.108) is no longer working. I need to reconfigure it with "telnet"...
    Reply  Sat Feb 3 13:03:45 2018, gautam, Update, Computer Scripts / Programs, netgpib data missing / PROLOGIX yellow box (crocetta) not working 
The netgpibdata scripts are now under git version control at /opt/rtcds/caltech/c1/scripts/general/labutils/netgpibdata. I think the idea was to make
this directory a collection of useful utilities that we could then pull at various labs / at the sites.
    Reply  Mon Feb 5 18:04:35 2018, Koji, Update, Computer Scripts / Programs, netgpib data missing / PROLOGIX yellow box (crocetta) not working 
crochetta was reconfigured to have 192.168.113.108. It was confirmed that it can be used with netgpibdata.py

Configuration: I have connected my mac with the unit using an Apple USB-Ethernet adapter. The adapter was configured to have a manual IP of 192.168.113.222/255.255.255.0.
"netfinder.exe" was run to assign the IP addr to the unit. It seemed that NVRAM of the unit evaporated as it had the IP of 0.0.0.0. Once it was
Entry  Tue Apr 24 10:10:43 2018, gautam, Update, Computer Scripts / Programs, Particle swarm hyper parameter optimization ClusterFminScaled.pngClusterID_5.png
I'm copying and pasting Nikhil's email here as he was unable to login to the elog (but should now be able to in order to reply to any comments,
and add more details about this test, motivation, methodology etc).


I did some post-processing after running the grid search. The following
Entry  Mon Apr 30 23:13:12 2018, Kevin, Update, Computer Scripts / Programs, DataViewer leapseconds 
I was trying to plot trends (min, 10 min, and hour) in DataViewer and got the following error message

Connecting....
done
Entry  Thu Jun 7 20:21:15 2018, Koji, Update, Computer Scripts / Programs, /cvs/cds Backup in danger 
Local backup on chiara
seems not working since Nov 19, 2017. 
/opt/rtcds/caltech/c1/scripts/backup/localbackup.log
    Reply  Thu Jun 14 15:21:58 2018, gautam, Update, Computer Scripts / Programs, /cvs/cds Backup in danger 
I think this is because /cvs/cds is getting too big. lsblk reveals:

controls@chiara|~>
lsblk
Entry  Mon Jun 18 10:34:45 2018, johannes, Update, Computer Scripts / Programs, running comsol job on optimus 
I'm running a comsol job on optimus in a tmux session named cryocavs. Should be done in less than 24 hours, judging by past durations.
Entry  Tue Jul 10 16:59:12 2018, Izabella Pastrana, HowTo, Computer Scripts / Programs, Taking Remote TF Measurements with the Agilent 4395A 
I copied the netgpibdata folder onto rossa (under the directory ~/Agilent/), which contains all the necessary scripts and templates
you'll need to remotely set up, run, and download the results of measurements taken on the AG4395A network analyzer. The computer will communicate
with the network analyzer through the GPIB device (plugged into the back of the Agilent, and whose communication protocol is found in the AG4395A.py
Entry  Mon Aug 13 11:44:32 2018, gautam, Update, Computer Scripts / Programs, Patch updates on nodus 
Larry W said that some security issues were flagged on nodus. So I ran

sudo yum upgrade --exclude=elog-3.1.3-2.el7.x86_64

on nodus. The exclude flag
    Reply  Thu Oct 11 13:40:51 2018, yuki, Update, Computer Scripts / Programs, loss measurements 



Quote:



This is the procedure I follow when I take these measurements for the XARM (symmetric under XARM <-> YARM):


Dither-align the interferometer with both arms locked. Freeze outputs when done.
Misalign ETMY + ITMY.
ITMY
    Reply  Fri Oct 12 12:29:34 2018, yuki, Update, Computer Scripts / Programs, loss measurements 
With Gautam's help, Y-arm was locked. Then I ran the script "armloss_dcrefl_asdcpd_scope.py" which gets the signals from oscilloscope.
It ran and got data, but I found some problems.


It seemed that a process which makes arm cavity mislaigned in the script didn't work.
The script "armloss_dcrefl_asdcpd_scope.py"
    Reply  Fri Oct 12 20:20:29 2018, yuki, Update, Computer Scripts / Programs, loss measurements 
I ran the script for measuring arm-loss and calculated rough Y-arm round trip loss temporally. The result was 89.6ppm. (The error should be considered
later.)

The measurement was done as follows:
    Reply  Sat Oct 13 20:11:10 2018, yuki, Update, Computer Scripts / Programs, loss measurements 



Quote:



the script "armloss_AS_calc.py",


"ETM_YAW_L_DEMOD_I_OUTPUT" was little noisy even when the arm was locked.
The reflected beam power when
ELOG V3.1.3-