Entry  Fri Jan 4 08:42:03 2008, steve, Update, SUS, etmy trips again etmy20m.jpgetmy120s.jpgetmysenV.jpg
ETMY sus damping tripped at 6am this morning
It was reset. We should put an accelerometer to the south end to see
the garbage dumping effect.
Entry  Mon Jan 7 09:01:39 2008, steve, Update, SUS, BS sus damping restored bssdl.jpg
The BS sus damping was lost at 8am Sunday morning.
Entry  Tue Jan 8 15:20:17 2008, Pkp, Update, Cameras, GigE update 
[Tobin , Pinkesh]

Finally we got the camera doing something (other than giving out its attributes). The only thing that seems to work so far is a program called AAviewer,
Entry  Wed Jan 9 10:47:15 2008, fricke, Update, Computers, ethernet wiring in office/control room 
The electrical people have been here for three days, installing ethernet cables and drops in the 40m office area, in the old conduits where there was power
and 10base2.  Soon we will have reliable ethernet connections, instead of relying on switches hanging from the ceiling, etc!
Entry  Wed Jan 9 20:36:42 2008, Go, Update, Treasure, Money in lab DSC_0370.JPG
Go's Desk.
Entry  Thu Jan 10 10:38:02 2008, steve, Update, SUS, etmy damping restored etmysus.jpgsustrend16d.jpg
The IST building onstruction has really started yesterday and continuing today with big heavy ground breaking
machinary. The MC is holding lock and the suspentions are hanging on.
Entry  Thu Jan 10 12:08:23 2008, steve, Update, SUS, why did the BS move? bshopped.jpg
 
Entry  Thu Jan 10 13:45:52 2008, Pkp, Update, Cameras, GLIBC Error 
So, I have tried to compile the camera files which are in /cvs/cds/caltech/target/Prosilica/examples for the past 2 days now and have been unable to get
rid of the following error. (specifically ListCameras.cpp, as it doesnt have any other libraries required, which unnecessarily complicates things)
Entry  Thu Jan 10 15:04:04 2008, steve, Update, SUS, illuminator light effect on BS position bssusilum.jpg
The bs chamber illuminator light was turned on this morning and left on.
Earlier on Rana noticed that the bs moved.
I follwed up to see what happened. I turned off oplev servo and tried to recenter on oplev pd
Entry  Fri Jan 11 17:01:51 2008, pkp, Update, Cameras, GigE again  
So, here I detail all the efforts on the GigE so far 

(1) The GiGE camera requires a minimum of 9 kb packet size, which is not available on mafalda or on my laptop ( both of which run Ubuntu and the Camera
Entry  Mon Jan 14 14:41:09 2008, steve, Update, SUS, etmy sus damping restored & mz relocked etmysus&mzhvtrend.jpg
Tree days trend of MZ HV drift is typical these days.
So as the etmy sus inability to hold damping for longer then 2-3 days.
Entry  Tue Jan 15 13:15:27 2008, tobin, Update, Environment, lots of noise 
They're throwing concrete around at the construction site.
Entry  Wed Jan 16 14:06:24 2008, rob, Update, LSC, monday's locking 
rob, tobin, johnnie

We did some locking work monday night, with decent progress.  Working in the PRFPMI style, we managed to get through the part of the script that hands
Entry  Wed Jan 16 14:09:45 2008, rob, Update, LSC, tuesday's locking 

I got a little further with the locking (PRFPMI) last night, after discovering that the cable going from the CM board to the MC board was unplugged at
the MC side.  This explains why we weren't able to engage the AO path last night.  Tonight, I got up to the point where DARM is handed off to OMC transmission,
Entry  Wed Jan 16 18:24:41 2008, rana, Update, SUS, ETMY Watchdog A.pdf
Because [COLOR=purple][B]Steve keeps complaining about ETMY[/B][/COLOR], I looked at some minute trend to see if there was something exotic happening at
that time. It looks like there is some tremendous seismic activity to make it happen.
Entry  Thu Jan 17 14:13:20 2008, rob, Update, LSC, Wednesday's locking 
Incremental progress on locking yet again.  This time the handoff of DARM to the OMC worked, and progress halted at handing off control of the common mode
to REFL166.  
Entry  Thu Jan 17 15:11:13 2008, josephb, Update, Cameras, Working on Malfalda 
1) I can statically compile the ListCamera code (which basically just goes out and finds what cameras are connected to the network) on Malfalda and use
that compiled code to run on Linux2 without a problem.  Simply needed to add explicit links to libpthread.a and librt.a.
(i.e. -Bstatic -L /usr/lib/ -lpthread -Bstatic -L /usr/lib -lrt)
Entry  Thu Jan 17 18:22:14 2008, Alberto, Update, Electronics, RF Monitor Band-pass Filter RF166Mhz.pngChebyshevb.pngChebyshev2b.png
After we finalized the schematic for the RF monitor board based on buffered LC resonators, on Richard Abbott's suggestion to avoid the complication brought
in by the fast op-amps, we gave another chance to the a passive configuration of the band-pass filter based on a Chebyshev topology. Rich and Ben gave
me an old but very powerful software tool to design that kind of filters and showed me the way to circumvent many hassles in making RF test boards.
Entry  Thu Jan 17 20:50:55 2008, tobin, Update, General, fiber coupling 
Sam, John, and I matched the beam from an NPRO into a fiber on the SP table today.  In doing so we used our GigE camera for a physics application for perhaps
the first time, viewing the transmitted mode from the fiber during initial alignment.  (I used my laptop running Windows and a 100 megabit switch.)
    Reply  Fri Jan 18 11:53:50 2008, Alberto, Update, Electronics, RF Monitor Band-pass Filter Chebyshevb.png
The response is asymmetric and on the left side of the peak, we have at least 33dB within 33Mhz, which is enough for all the frequencies. We probably don't
need an higher order filter but just low pass filters in series.
Entry  Fri Jan 18 15:31:47 2008, rob, Update, LSC, Thursday's locking DARMnoise080118.png

[I]rob, johnnie, andrey[/I]
Entry  Mon Jan 21 23:30:03 2008, Andrey, Update, Computer Scripts / Programs, Matlab Program for Q-factor measurements (XARM -> ITMX and ETMX) Example-ITMX_POS_40.png

Finally I overcame difficulties with adapting Sonia's Matlab programs for XARM (Sonia's program was for MC),
Entry  Tue Jan 22 02:33:45 2008, rob, Update, LSC, DRMI work 

0) The ETMY oplev needs work/centering
Entry  Tue Jan 22 13:11:03 2008, tobin, Update, ASC, ETMY oplev recentered 
The light wasn't even on the diode.
Entry  Wed Jan 23 09:27:55 2008, steve, Update, , etmy sus damping restored etmysus.jpg
Seismis event trips etmy
Entry  Wed Jan 23 11:41:06 2008, steve, Update, PEM, sulfur smell in 40m 
Led - acid car batteries were overcharged in the machine shop next door
and sulfuric acid smell is coming over to the ifo room.
Entry  Thu Jan 24 11:52:56 2008, steve, Update, PEM, the mud is cleaned up & MOPA shutter is opened 
Safety glasses are required again!

I have just opened the mopa shutter.
Entry  Fri Jan 25 09:22:21 2008, steve, Update, PEM, burned toast award goes to 
DYM for  collaborating with the enemy. 

In order to minimize the number of ants visiting our lab we have to take out side the lab
Entry  Fri Jan 25 15:53:59 2008, Alberto, Update, Electronics, 40 dB from the 3rd order Chebyschev 166MhzElog.png
I managed to tune the 7 knobs in the 3rd order Chebyshev bandpass filter obtaining the tranfer function attached to this entry. We have now 40 dB of attenuation
between 166 Mhz and 133 and 199. With this tuning the insertion loss is rather high. We need a better one.
Entry  Fri Jan 25 21:36:40 2008, rana, Update, CDS, mDV / channel issues 
[COLOR=orange]Fri Jan 25 21:30:00 2008[/COLOR] 

As it turns out, the residual problem with the mDV stuff was not to do with our button pushing episode but instead fallout from the 'turning off of the
Entry  Sat Jan 26 02:34:34 2008, Andrey, Update, Computer Scripts / Programs, Overnight Measuremts in XARM 

I am running the program for measuring RMS of peaks in XARM tonight. I just started it, and it will run for about 9 hours until noon on Saturday. Please
do not disturb the interferometer. Now the XARM is locked, it should stay locked over the night.
Entry  Sat Jan 26 22:00:03 2008, John, Update, General, LSC-TRY_OUT and ETMY-QPD 
In the path from the ETM to the trans PD and QPD at the Y end I have replaced a BS1-1064-10-2037-45P with a polariser. The power falling on these diodes
has been reduced. When the arm is locked in its nominal state the transmitted power is now less than 1.
Entry  Sun Jan 27 21:44:48 2008, rana, Update, CDS, Seismic BLRMS on Matlab seisBLRMS.m
I wrote a matlab script to produce band limited RMS trends from our accelerometers. It mimics the code written
by Ed Daw which makes the seismic FOMs at the sites.
Entry  Mon Jan 28 18:56:47 2008, rana, Update, DMF, seisBLRMS 1.0 
[B]I made all of the updates I aludded to before:[/B]

[LIST]
    Reply  Tue Jan 29 14:56:39 2008, rob, Update, DMF, seisBLRMS 1.0 

The [COLOR=red]seisBLRMS[/COLOR] 1.0 program crashed at ~7:20 pm last night, so we didn't get data from overnight.  It crashed when framecaching failed.
 I added
Entry  Wed Jan 30 13:09:55 2008, Andrey, Update, SUS, New results for XARM (pdf) New_Results_XARM.pdfAccel-Seismic_10AM.pdf

See attachments: pdf-presentation with plots in "true" axes Q_ETMX and Q_ITMX, and seismic backgound measurement.
Entry  Wed Jan 30 20:39:31 2008, rob, Update, DMF, seisBLRMS 


In order to reduce the probability of [COLOR=red]seisBLRMS[/COLOR] crashing due to unavailability of data, I edited [COLOR=red]seisBLRMS.m[/COLOR] so that
Entry  Fri Feb 1 10:43:05 2008, John, Update, Environment, Construction work DSC_0433.JPG
The boys next door have some [URL=http://dziban.ligo.caltech.edu:40/40m/?mode=full&reverse=0&reverse=1&npp=20&subtext=hammer]bigger noisier[/URL] toys.
Entry  Fri Feb 1 12:37:39 2008, rob, Update, DMF, seisBLRMS trends seis36hours.pngseis2hours.png

Here are DV trends of the output of seisBLRMS over the last ~36 hours (which is how long it's been running), and another of the last 2 hours (which show
the construction crew taking what appears to be a lunch break).  
Entry  Sun Feb 3 05:02:41 2008, rana, Update, PEM, Seism 4 day Screenshot.png
 
Entry  Wed Feb 6 09:17:31 2008, steve, Update, PEM, IST building construction continoues seismic8d.jpgseisioo.jpg
The bulldosers at work
Entry  Fri Feb 8 17:09:52 2008, Max Jones, Update, Computers, Changes to NoiseBudget 
Today I altered the following files 

caltech/NB/matlab/utilities/get_dtt_dataset
Entry  Mon Feb 11 14:24:19 2008, steve, Update, PEM, more earthquakes eqfeb11.jpg
ITMX and ITMY sus damping restored after Baja earthquake 5.1 mag at 10:29 this morning.

The ground preparation for The ITS building is almost finished.
Entry  Tue Feb 12 16:39:52 2008, rob, Update, Locking, report 

Did some locking work on DRFPMI on sunday and (with John) on monday nights.  So far progress has not been terribly encouraging.  
Entry  Wed Feb 13 11:41:00 2008, Alberto, Update, Electronics, Some characterization of the RF Monitor Box (StocMon) CircuitCharacterization.pngalberto.spectrum3.png
I'm attaching a table with some measurements and the power spectrum from the pd to help evaluate the numbers.

The box output ranges from 0.5V to 2.1V. The coefficient between power and voltage is negative so higher voltage means lower power.
Entry  Wed Feb 13 20:37:11 2008, John, Update, LSC, Fibre locking - Fiber 
Sam and I observed fringes in the light reflected from the Y arm. These fringes are due to the sidebands and not the carrier. To improve matters we plan
to reduce the RF AM and increase our modulation index.
Entry  Thu Feb 14 17:21:53 2008, Max Jones, Update, Computers, Noise budget code changes 
In cvs/cds/caltech/NB/matlab/utilities/LSCmodel.m at line 146
I have hardwired in changes to struct lsc. Please see code. 
    Reply  Fri Feb 15 10:28:44 2008, rana, Update, Computers, Noise budget code changes 
[quote]In cvs/cds/caltech/NB/matlab/utilities/LSCmodel.m at line 146
I have hardwired in changes to struct lsc. Please see code. [/quote]
The IFOin variable (which I admit is not documented) should refer to a file called
Entry  Fri Feb 15 22:16:04 2008, Andrey, Update, Computers, MATLAB is not working: "Licence checkout failed" 

For some unknown to me reason, 
Entry  Mon Feb 18 12:04:39 2008, Alberto, Update, Electronics, RF Monitor (StocMon) DSC_0443.JPG
I put the amplifiers next to the monitor on the PSL table, layed the power and the RF SMA cables out to the rack. I'm powering the box and the amplifiers
with the power supply, waiting for someone to show me tomorrow how to connect it to the Sorensen (Steve, Ben?).