40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 77 of 341  Not logged in ELOG logo
ID Date Author Typeup Category Subject Text Attachments
  325   Wed Feb 20 11:34:17 2008 steveUpdatePSLlaser head temp is upMOPA head temp is running at 20.3C now
Nomally it is at 18.5C
 htempup.jpg 
  326   Wed Feb 20 16:24:37 2008 steveUpdatePSLthe laser is recovering slowlyHead temp is still 20.5C and decreasing slowly.
Power output 2.9W 
NPRO power 22 mW is increasing as head is
 laserecoverring.jpg 
  327   Thu Feb 21 09:56:26 2008 steveUpdatePSLthe laser is backThe laser and the psl recovered. 
The water chiller temp is 19.98C and head
temp 18.4C
 laserisback.jpg 
  329   Thu Feb 21 19:55:46 2008 ranaUpdateElectronics2 BNC Cables, 1 TeeI'm not sure where [COLOR=purple]Ward and
Miller went to Analyzer school[/COLOR], but
it was probably uncredited.
  
  330   Fri Feb 22 02:51:20 2008 AndreyUpdatePEMAccelerometer ITMX seems to be broken
As people probably know,
 Accelerom-EYMX-Feb22.jpgAccelerom-ITMX-Feb22.jpg 
  331   Fri Feb 22 08:29:07 2008 AlbertoUpdateElectronicsRF Monitor (StocMon)[quote]I put the amplifiers next to the monitor
on the PSL table, layed the power and the
RF SMA cables out to the rack. I'm powering
  
  332   Fri Feb 22 08:33:18 2008 AlbertoUpdateElectronicsRF Monitor (StocMon)[quote]I put the amplifiers next to the monitor
on the PSL table, layed the power and the
RF SMA cables out to the rack. I'm powering
  
  333   Fri Feb 22 11:11:00 2008 robUpdateElectronicsREFLDD problem found
I used a network analyzer that actually works
to find a problem in the REFLDD electronics
  
  334   Fri Feb 22 11:13:15 2008 robUpdateElectronicsRF Monitor (StocMon)[quote] It took some times because the written
procedure to start the chiller is not very
precise.[/quote]
  
  335   Fri Feb 22 14:45:06 2008 steveUpdateMOPAlaser power levels
At the beginning of this 1000 days plot shows
the laser that was running at 22C head temp
 lpower1000d.jpg 
  336   Fri Feb 22 15:16:33 2008 AndreyUpdatePEMITMX Accelerometer is NOT broken
As I wrote in message 330, there was a bad
signal from ITMX accelerometer. I have found
 Accelerom-ITMX-Feb23.jpgAccelerom-ETMX-Feb23.jpg 
  337   Fri Feb 22 16:47:54 2008 robUpdateElectronicsBaloneyWell I guess Rana didn't study too hard at
Professor School, either.  If he'd even bothered
to actually read John's entry, he might have
 bustedHP.mov 
  342   Wed Feb 27 22:05:03 2008 JohnUpdateLSCAuxiliary lockingA summary of the status of the auxiliary arm
locking effort.
  
  344   Thu Feb 28 13:04:59 2008 robUpdateVACrga logging working again[quote]The rga head and controller are running
fine, but the data logging is not.[/quote]
  
  347   Thu Feb 28 19:49:21 2008 robUpdateElectronicsRF Monitor (StocMon)
[quote]
With Ben, we hooked up the RF Monitor box
  
  351   Mon Mar 3 09:25:33 2008 steveUpdateVACrga scan logging is working now[quote][quote]The rga head and controller
are running fine, but the data logging is
not.[/quote]
 rgalogworks.jpgcc1.jpg 
  352   Mon Mar 3 13:58:10 2008 steveUpdateComputers RFM Network are downThe CODAQ_RFNETWORK are down, except C1SUSVME
& AWG
  
  353   Mon Mar 3 19:34:40 2008 ranaUpdateComputers RFM Network are down[quote]The CODAQ_RFNETWORK are down, except
C1SUSVME & AWG[/quote]
All of the FE machines were found to be down
  
  354   Tue Mar 4 00:42:51 2008 ranaUpdateComputersFB0 still down ?The framebuilder is still down. I tried restarting
the daqd task and resetting the RFM
switch like it says in the Wiki but it still
  
  355   Tue Mar 4 10:08:21 2008 robUpdateComputersgreen lights unreliable when c0daqctrl down
So far I've tried powering off the framebuilder,
power-cycling the RAID (it was showing an
  
  361   Wed Mar 5 17:35:24 2008 ranaUpdateIOORFAM during MC lockI used an ezcaservo command to adjust the
offsets for Alberto's StochMon channels.
They [B][COLOR=green]are all
 rfam.pdf 
  362   Thu Mar 6 00:17:37 2008 robUpdateLockingDD handoff workingGot the DD (double demod) handoff scripts
working tonight, with just the DRMI.  So,
now acquisition with the single demod signals
  
  364   Fri Mar 7 17:10:01 2008 Max JonesUpdateComputersNoise Budget workNoise budget has been moved to the svn system.
A checked out copy is in the directory caltech.
From now on, I will try to use the work cycle
  
  366   Mon Mar 10 02:05:08 2008 robUpdateLockingDRMI+2ARMs working better
Some encouraging progress on the locking
front tonight.  After the work on the DRM
  
  372   Wed Mar 12 23:05:44 2008 ranaUpdateIOOMC WFSthey are bad, somewhat

please fix
  
  375   Thu Mar 13 12:11:58 2008 aivanovUpdateComputer Scripts / Programsrouting PEM -> ASS -> SUS_MCL
on ASS RFM 1 has PEM signals at
  
  376   Thu Mar 13 13:15:09 2008 aivanovUpdateComputer Scripts / Programsnew sfotware intall, backup filesNew:
op440m:40m>ls -alt /cvs/cds/caltech/target/c1susvme[12]/*.o
-rw-r--r--    1 controls staff       57920
  
  377   Thu Mar 13 18:20:29 2008 JohnUpdateGeneralNew Focus 4003 EOM 29.489MHzI measured the modulation index as a function
of drive power using an OSA. Agrees well
with spec of 0.2 rad/V.
 4003.jpg 
  380   Fri Mar 14 15:06:24 2008 robUpdateComputer Scripts / Programsrouting PEM -> ASS -> SUS_MCL[quote]
on ASS RFM 1 has PEM signals at
  
  385   Thu Mar 20 15:28:20 2008 steveUpdateVACtp2 's drypump replacedThe fore pump of tp2 was replaced at fore
line pressure 998m Torr
  
  388   Fri Mar 21 09:02:03 2008 steveUpdateVACtp 2 failedSmall turbo #2 is the forepump of the maglev.
It failed last night, shut down the  maglev
and interlock closed V1
  
  389   Fri Mar 21 11:54:38 2008 robUpdateVACtp 2 failed[quote]Small turbo #2 is the forepump of the
maglev.
It failed last night, shut down the  maglev
  
  396   Sun Mar 23 00:56:42 2008 JohnUpdateLSCMore on 3f We ended our last attempt at 3f locking concerned
about the beam size on PD6. I investigated
tonight. The beam was not obviously overfilling
  
  398   Mon Mar 24 13:03:54 2008 robUpdateElectronicsHP4195A is back

[quote]The swept sine output looks totally
  
  400   Tue Mar 25 10:44:24 2008 robUpdateComputersc1susvme2[quote]c1susvme2 isn't behaving itself. It
keeps getting out of sync and/or giving a
red status light.
  
  401   Tue Mar 25 13:21:25 2008 AndreyUpdateComputersc1susvme2 is not behaving itself again    
  402   Tue Mar 25 15:56:09 2008 JohnUpdateTreasureAssorted picturesSome pictures scavenged from the D40.  D40.pdf 
  403   Tue Mar 25 16:34:47 2008 robUpdateComputersc1susvme2[quote][quote]c1susvme2 isn't behaving itself.
It keeps getting out of sync and/or giving
a red status light.
  
  405   Wed Mar 26 22:26:15 2008 JohnUpdateComputersc1susvmeI removed the fan and tweaked the timing cables
to see if they were the source of our problems.
I saw no effect. I'm leaving the fan off
  
  406   Fri Mar 28 16:18:18 2008 robUpdateComputersc1susvme2 statusc1susvme2 is getting worse and worse.  it
won't run for more than ~45 minutes without
fatally de-syncing.  for now I've turned
  
  408   Mon Mar 31 14:14:16 2008 robUpdateComputersc1susvme2 status[quote]c1susvme2 is getting worse and worse.
 it won't run for more than ~45 minutes without
fatally de-syncing.  for now I've turned
  
  409   Wed Apr 2 15:03:51 2008 steveUpdateGeneralreflectivity of black glass The reflectivity of black glass, shade 12
was supplied by Donald O'Shea
of Emerald Glass Inc., Westlake, OH 44145
 bg12refl.pdfbg12refsetup.pdf 
  416   Mon Apr 7 16:42:56 2008 ranaUpdateComputerseLog intermittentPhil Ehrens restarted Dziban again this morning.
Looks like its still crashing each Monday
around 8 AM.
  
  417   Mon Apr 7 18:58:49 2008 steveUpdateGeneralreflectivity of SS304The reflectivity of stainless steel 304 super
polished # 8 was measured the same way as
elog entry 409
 ss304s8refl.pdf 
  421   Wed Apr 16 10:20:01 2008 AndreyUpdateComputersRosalba and linux3[quote]There is a new computer in the control
room -- its called [B][COLOR=purple]Rosalba[/COLOR][/B],
in keeping with our naming convention. Its
  
  423   Thu Apr 17 15:00:59 2008 steveUpdateVACvac controller computer to be replacedNow that Rosalba is up and running someone
should step forward to volunteer for this
job.
  
  424   Thu Apr 17 20:17:37 2008 AndreyUpdatePEMTwo issues with our weather station
I encountered two difficulties working with
the "Weather Station".
  
  425   Fri Apr 18 16:02:58 2008 alexUpdateSUSend station sus front-end bug fixinstalled and started new susEtmx.o and susEtmy.o
to fix a problem with ETMY optical lever
variables.
  
  426   Fri Apr 18 16:27:04 2008 robUpdateSUSend station sus front-end bug fix[quote]installed and started new susEtmx.o
and susEtmy.o to fix a problem with ETMY
optical lever variables.[/quote]
  
  427   Fri Apr 18 16:48:13 2008 AndreyUpdatePEMRain collector of weather station
Today the rain collector of our weather station
was cleaned. As a result, we checked that
 DSC_0520--before.JPGDSC_0537--after.JPG 
ELOG V3.1.3-