Wed Jun 18 19:30:28 2014 |
Jenne | Update | Computer Scripts / Programs | Rossa having a better day |
I have modified the /etc/default/grub file, so that we're loading up the previous linux kernel version on reboot. Now Rossa boots up (at least one time so far) without any fancy button-pushing.
(Note, if things go south again, we have to push "shift" starting after the Dell screen is gone. Holding it down while the Dell screen is still up doesn't seem to make it register that you want the grub menu).
The grub file USED to look like:
GRUB_DEFAULT=0
GRUB_HIDDEN_TIMEOUT=0
GRUB_HIDDEN_TIMEOUT_QUIET=true
GRUB_TIMEOUT=10
GRUB_DISTRIBUTOR=`lsb_release -i -s 2> /dev/null || echo Debian`
GRUB_CMDLINE_LINUX_DEFAULT="quiet splash"
GRUB_CMDLINE_LINUX=""
but now it looks like:
GRUB_DEFAULT=2
GRUB_HIDDEN_TIMEOUT=0
GRUB_HIDDEN_TIMEOUT_QUIET=false
GRUB_TIMEOUT=10
GRUB_DISTRIBUTOR=`lsb_release -i -s 2> /dev/null || echo Debian`
GRUB_CMDLINE_LINUX_DEFAULT="quiet splash"
GRUB_CMDLINE_LINUX=""
Note that the first line, GRUB_DEFAULT has changed from 0 (first item in grub menu, if you successfully hit shift and get to it) to 2 (the third item in the list). I think that the GRUB_HIDDEN_TIMEOUT_QUIET=false is supposed to force it to show the countdown time when you can push shift, but I didn't see any difference there.
To edit this file, you must use "sudo [text editor] grub ". I like emacs, so I used "sudo emacs grub ". After an edit, before a reboot, you must run "sudo update-grub ". Then you can reboot (sudo shutdown -r now is what I use), and hopefully it will boot as you directed.
Right now, the 0th (first) entry in the grub menu is "Ubuntu, with Linux 2.6.32-61-generic". The 2nd (third) entry is "Ubuntu, with Linux 2.6.32-58-generic". If we install a new kernel version, the 61 version will bump down in the list, and we'll be booting that, which I assume will fail. We should not update Rossa until we're ready to go to Ubuntu 12, and when we do, we must ensure that the grub file first line reads GRUB_DEFAULT=0. (As a side note, the 1st (really 2nd) entry in the grub menu is "Ubuntu, with Linux 2.6.32-61-generic (recovery mode)", which we don't want. The 58 version has a recovery mode as the next line item, since it alternates version-N, version-N recovery mode, version-(N-1), version-(N-1) recovery mode, etc.) |
10073
|
Thu Jun 19 14:52:20 2014 |
not ericq | Update | Computer Scripts / Programs | control room bashrc change |
Quote: |
Some time ago, Rana changed the PS1 prompt codes on the control room computers. However, the exit codes of commands weren't being displayed, and there was some lingering color changing after the line. Hence, I changed it to look like this:
PS1='\[\033[0;35m\]\u'
PS1="$PS1\[\033[0;30m\]@"
PS1="$PS1\[\033[0;33m\]\h"
PS1="$PS1\[\033[0;97m\]|"
PS1="$PS1\[\033[0;92m\]\W"
PS1="$PS1\[\033[0;31m\] \${?##0}"
PS1="$PS1\[\033[0;97m\]>\[\033[0m\] "
The \${?##0} means: display the exit code if it is not zero (which means success). Thus, it only displays the exit code when its something other than what is expected.
|
 It's a very good plan to always inspect the exit code of your command. Well done. |
10074
|
Thu Jun 19 16:49:15 2014 |
rana | Update | Computer Scripts / Programs | autolocker running again |
We've noticed that the caget/caput and cdsutils take a long time to return the command prompt. The following two ping commands indicate that it may be related to routing or our new BIND9 DNS setup on chiara.
controls@ottavia|~ > ping -c 5 -D c1sus
PING c1sus.martian (192.168.113.85) 56(84) bytes of data.
[1403221338.383403] 64 bytes from 192.168.113.85: icmp_req=1 ttl=64 time=0.114 ms
[1403221343.386211] 64 bytes from 192.168.113.85: icmp_req=2 ttl=64 time=0.059 ms
[1403221348.387666] 64 bytes from 192.168.113.85: icmp_req=3 ttl=64 time=0.060 ms
[1403221353.389736] 64 bytes from 192.168.113.85: icmp_req=4 ttl=64 time=0.059 ms
[1403221354.390713] 64 bytes from 192.168.113.85: icmp_req=5 ttl=64 time=0.060 ms
--- c1sus.martian ping statistics ---
5 packets transmitted, 5 received, 0% packet loss, time 20007ms
rtt min/avg/max/mdev = 0.059/0.070/0.114/0.023 ms
controls@ottavia|~ > ping -c 5 -D 192.168.113.85
PING 192.168.113.85 (192.168.113.85) 56(84) bytes of data.
[1403221463.737857] 64 bytes from 192.168.113.85: icmp_req=1 ttl=64 time=0.078 ms
[1403221464.737353] 64 bytes from 192.168.113.85: icmp_req=2 ttl=64 time=0.059 ms
[1403221465.737318] 64 bytes from 192.168.113.85: icmp_req=3 ttl=64 time=0.050 ms
[1403221466.737316] 64 bytes from 192.168.113.85: icmp_req=4 ttl=64 time=0.052 ms
[1403221467.737321] 64 bytes from 192.168.113.85: icmp_req=5 ttl=64 time=0.050 ms
--- 192.168.113.85 ping statistics ---
5 packets transmitted, 5 received, 0% packet loss, time 3999ms
rtt min/avg/max/mdev = 0.050/0.057/0.078/0.014 ms
|
10077
|
Thu Jun 19 22:04:23 2014 |
ericq | Update | Computer Scripts / Programs | caget/caput now return in reasonable time |
I think I've fixed the caget/caput issue. Rana's observation that pinging the IP directly was faster than pinging the hostname set me on a path of googling which informed making the following changes to the DNS setup on chiara (specifically, informed by this thread: http://www.dslreports.com/forum/r11836974-BIND-slow-to-reply-over-LAN-Solved)
/etc/bind/named.conf.local has these lines:
zone "martian" IN {
type master;
file "/etc/bind/zones/martian.db";
};
zone "113.168.192.in-addr.arpa" {
type master;
file "/etc/bind/zones/rev.113.168.192.in-addr.arpa";
};
The first zone command links hostnames like c1lsc to an IP like 192.168.113.62, but apparently in the second, we need to do the inverse. So, for each line in martian.db like
c1lsc A 192.168.113.62
I added a line in rev.113.168.192.in-addr.arpa like so:
62 IN PTR c1lsc.martian
This seems kind of silly, but now if you do the host command from a workstation, it can find the hostname associated with an IP.
controls@pianosa|~ > host 192.168.113.62
62.113.168.192.in-addr.arpa domain name pointer scipe12.martian.113.168.192.in-addr.arpa.
62.113.168.192.in-addr.arpa domain name pointer c1lsc.martian.113.168.192.in-addr.arpa.
[At this point, note that we have a bunch of duplicate entries in https://wiki-40m.ligo.caltech.edu/Martian_Host_Table with these scipe## hostnames. What are these for?]
Now (edited for brevity):
controls@ottavia|~ > ping -c 5 -D c1sus
PING c1sus.martian (192.168.113.85) 56(84) bytes of data.
<SNIP>
--- c1sus.martian ping statistics ---
5 packets transmitted, 5 received, 0% packet loss, time 3997ms
rtt min/avg/max/mdev = 0.051/0.075/0.114/0.028 ms
controls@ottavia|~ > ping -c 5 -D 192.168.113.85
PING 192.168.113.85 (192.168.113.85) 56(84) bytes of data.
<SNIP>
--- 192.168.113.85 ping statistics ---
5 packets transmitted, 5 received, 0% packet loss, time 3998ms
rtt min/avg/max/mdev = 0.052/0.130/0.380/0.127 ms
controls@pianosa|~ > time caget C1:LSC-XARM_GAIN
C1:LSC-XARM_GAIN 0.015
real 0m0.039s
controls@pianosa|~ > time caput C1:LSC-XARM_GAIN 0.0151
Old : C1:LSC-XARM_GAIN 0.015
New : C1:LSC-XARM_GAIN 0.0151
real 0m0.054s
|
10080
|
Fri Jun 20 11:43:30 2014 |
ericq | Update | Computer Scripts / Programs | Restarting ELOG |
Manasa let me know that the ELOG was down, and that she used the normal restart procedure, but then all entries were gone.
This is because the ELOG has been moved on nodus, so going to the old place and running the restart script starts up the old dysfunctional ELOG installation.
The proper place to restart the ELOG is now nodus:/export/home/elog/start-elog.csh
I'm updating the relevant 40m wiki page now. |
10084
|
Fri Jun 20 19:07:44 2014 |
rana | Update | Computer Scripts / Programs | op340m DNS |
I had forgotten to fix the DNS setup on op340m and so our slow, perl, PID loops for the laser were not running well (and that's why the FSS-FAST has been saturating).
I edited /etc/resolv.conf on there and then did /usr/sbin/reboot as super-user.
op340m:~>more /etc/resolv.conf
domain martian
nameserver 192.168.113.104
nameserver 131.215.125.1
nameserver 131.215.139.100
nameserver 131.215.9.49
op340m:~>date
Fri Jun 20 19:06:37 PDT 2014
The FSSSlowServo.pl now seems to be holding the NPRO PZT to ~6 V. I twiddled the PID settings a little bit to make sure nothing was squirrelly. Seems OK. Time constant of the loop is ~1 minute.
As a reminder, op340m runs our autoburt for all the FE machines, VME IOCs, does the watchdog threshold rampdown, and also the RefCav and NPRO temperature control. |
10095
|
Tue Jun 24 22:46:15 2014 |
ericq | Update | Computer Scripts / Programs | op340m crons |
Quote: |
The FSSSlowServo.pl now seems to be holding the NPRO PZT to ~6 V. I twiddled the PID settings a little bit to make sure nothing was squirrelly. Seems OK. Time constant of the loop is ~1 minute.
As a reminder, op340m runs our autoburt for all the FE machines, VME IOCs, does the watchdog threshold rampdown, and also the RefCav and NPRO temperature control.
|
We had fiddled with the scripts/general/scripto_cron script to try and get the MC auto locker working on ottavia, but in doing so broke op340m's reliance on it to run it's cron jobs, like FSSSlowServo .
I've reverted scripto_cron to its original state, and the FSS slow servo starts up again.
However, scripts like this that we want to always have on seem to be a better fit, to me, for the init system, like we do with daqd and nds on the FB. op340m's inittab looks different than what I'm used to, so I'm not making any changes; this is just a thought.
MC autolocker is still being ran from an Ottavia GUI terminal; I'll try to get it consistently running on megatron, as suggested in ELOG10039, now that caget/caput issues seem to be sorted.
Addendum: I've changed the MC auto locker script to have megatron as its host. Haven't yet gotten it to run automatically; it's running in a detached tmux terminal. I'll finish it up tomorrow. |
10108
|
Fri Jun 27 18:07:38 2014 |
Nichin | Update | Computer Scripts / Programs | Updated script for acquiring data from Agilent 4395A network analyzer |
The updated script for remotely getting data from Agilent 4395A network analyzer is located at /users/nichin
This network analyzer device is located at crocetta.martian (192.168.113.108)
How to run the script:
> python NWAG4395A_modified.py [filename.yml]
- The script accepts sweep parameters and output options via a .yml file that is written following a template that can be found at /users/nichin/NWAG4395template.yml
- The data obtained is stored as a .dat file and the corresponding details regarding the acquired data is in a .par parameter file
- You can choose to get a plot of the data obtained by specifying it in the .yml file. The plots are automatically stored as PDF.
- Plots, data and parameter files are all stored in a new folder that is created with a timestamp in its name.
- NOTE: Plotting options are only available in computers running numpy versions of 1.6.0 or above. The plotting sections of the code worked on Chiara, which has a 1.6.1 numpy, but did not work on Rossa which only had 1.3.0 numpy. Anyway, I have added an extra function that checks the version and skips the plotting part if needed.
Test Run:
I connected a simple 2MHz Low pass filter between the modulation output and signal input of the NA and ran a scan from 0Hz to 20MHz. The script was run from Chiara.
The expected plot was obtained and is attached here.
Further work:
I now have to work on setting up the RF switch in rack 1Y1 to select between required PDs and also on the code that chooses which channel is being selected.
There is also a problem of 2 8x1 RF switches being present, instead of one 16x1. Alex's code for RF switching does not take this into account.
RXA: I've deleted your plot because it didn't meet the minimal Bode plot standards. Please look up "Bode Plot" using Google/Wikipedia and try to follow some good example. Bode plot should contain Phase as well as magnitude. Also, the axes must be labeled with some physical units. |
10111
|
Mon Jun 30 00:18:15 2014 |
Nichin | Update | Computer Scripts / Programs | Updated script for acquiring data from Agilent 4395A network analyzer |
Quote: |
RXA: I've deleted your plot because it didn't meet the minimal Bode plot standards. Please look up "Bode Plot" using Google/Wikipedia and try to follow some good example. Bode plot should contain Phase as well as magnitude. Also, the axes must be labeled with some physical units.
|
Sorry Rana for not giving much attention to the plot. I will definitely change the way they are being plotted.
I was more focused on getting the data acquisition to work. Also, the current script gets only the magnitude and not the phase... I still have to work on that. |
10116
|
Tue Jul 1 13:57:33 2014 |
ericq | Update | Computer Scripts / Programs | MC Autolocker on Megatron |
Just a quick update on the status of the auto locker:
The auto locker now runs and respawns automatically on megatron, through ubuntu's "upstart" init system, instead of cron.
- The autolocker script itself is:
/opt/rtcds/caltech/c1/scripts/MC/AutoLockMC.csh
- The startup script called by the upstart system is:
/opt/rtcds/caltech/c1/scripts/MC/AutoLockMC.init
- The upstart configuration is:
/etc/init/MCautolocker.conf
- The auto locker is started by executing this command on megatron:
sudo initctl start MCautolocker
This was pretty simple to set up, once I figured out how to provide the necessary environment variables in AutoLockMC.init |
10117
|
Tue Jul 1 18:06:13 2014 |
nichin | Update | Computer Scripts / Programs | Network Analyzer NWAG4395A data acquisition |
EDIT: The script and template file have been moved to /opt/rtcds/caltech/c1/scripts/general/netgpibdata/
___________________________________________________________________________________________________________
The NEW and IMPROVED script for remotely getting data from Agilent 4395A network analyzer is located at /users/nichin
This script is quite different from the one in Elog 10108 and fetches us both magnitude and phase. There is an added feature of setting the IF Bandwidth.
The network analyzer is located at crocetta.martian (192.168.113.108)
How to run the script:
> python NWAG4395A_data_acq.py [filename.yml]
- The script accepts sweep parameters and output options via a .yml file that is written following a template that can be found at /users/nichin/NWAG4395A_parameters.yml
- The data obtained is stored as a .dat file and the corresponding details regarding the acquired data is in a .par parameter file
- Separate .dat and .par files are created for phase and magnitude of voltage data.
- You can choose to get a plot of the data obtained by specifying it in the .yml file. The plots are automatically stored as PDF.
- Plots, data and parameter files are all stored in a new folder that is created with a timestamp in its name.
- NOTE: Plotting options are only available in computers running numpy versions of 1.6.0 or above.(Currently only Ottavia and Chiara)
Test Run:
I connected a simple 2MHz Low pass filter between the modulation output and signal input of the NA and ran a scan from 100KHz to 20MHz. The script was run from Ottavia.
The expected plot was obtained and is attached here.
Current work:
Setting up the RF switch in rack 1Y1 to select between required PDs and scripts to tell it which channel to choose over the Ethernet.
|
10122
|
Wed Jul 2 15:35:34 2014 |
ericq | Update | Computer Scripts / Programs | Local Chiara backups |
Koji has provided a 2TB USB3 external hard drive that will get daily backups of chiara:/home/cds , the idea being that if the internal HD at /dev/sdb1 fails, we can physically open the external up, and swap the hard drive into chiara.
We're running an rsync job on it right now, which should be done in a few hours. (USB3 is fast!)
I've also written a backup script at scripts/backup/rsync_chiara.backup which keeps its books in scripts/backup/rsync_chiara.backup.log
I'm adding a entry to the root crontab on chiara to execute the script every day at 7am.
|
10177
|
Thu Jul 10 17:33:26 2014 |
jamie | Omnistructure | Computer Scripts / Programs | ubuntu12 software installed, gds 2.16.3.2 |
Rana wanted the latest GDS installed (for newest DTT), so I made an ubuntu 12 install directory into which I installed
- gds-2.16.3.2
- root_v5.34.03
I installed this stuff in
/ligo/apps/ubuntu12
which is the "official" location for stuff compiled specifically for ubuntu12.
Given that the workstations are diverging in OS (some ubuntu10, some ubuntu12), we're going to have to start supporting different software packages for the different versions, thus the new ubuntu12 directory. This will be a pain in the butt, and will certainly lead to different versions of things for different machines, different features, etc. We should really try to keep things at the same OS.
In any event, if you want to enable the GDS on an ubuntu 12 machine, source the ubuntu12 ligoapps-user-env.sh file:
controls@ottavia|~ > . /ligo/apps/ubuntu12/ligoapps-user-env.sh |
10178
|
Thu Jul 10 17:53:19 2014 |
Akhil | Configuration | Computer Scripts / Programs | EPICS installed on Raspberry Pi |
I finished the installation of EPICS base on Raspberry Pi (domenica: /opt/epics). I tested it by creating a test SoftIoc (controls@domenica~/freqCountIOC/simple.db) and was able to read from the channel on Chiara.
Now I am looking into how to call my C code that talks to Raspberry Pi through a .db script and write it into the assigned channel.
For installation I had to make these declarations in the environment (~/.bash_aliases):
export EPICS_EXT=${EPICS_ROOT}/extensions
export EPICS_EXT_BIN=${EPICS_EXT}/bin/${EPICS_HOST_ARCH}
export EPICS_EXT_LIB=${EPICS_EXT}/lib/${EPICS_HOST_ARCH}
if [ "" = "${LD_LIBRARY_PATH}" ]; then
export LD_LIBRARY_PATH=${EPICS_EXT_LIB}
else
export LD_LIBRARY_PATH=${LD_LIBRARY_PATH}:${EPICS_BASE_LIB}
fi
export PATH=${PATH}:${EPICS_EXT_BIN}
|
10197
|
Mon Jul 14 17:51:34 2014 |
Nichin | Update | Computer Scripts / Programs | MEDM for PDFR system |
A
Successfully completed the rudimentary GUI for PDFR system. (users/nichin/PDFR)
Pressing any of the buttons above runs the script that does the following:
1) Change RF mux channel to the required one.
2) Frequency sweep on the network analyzer. The common sweep parameters are in a file named param_NWAG4395A.yml . PD specific parameters are in param_[PD name].yml in their respective folders
3) The transimpedance is calculated and the plot is saved as PDF in the respective folder for the PD. Each set of measurement data and plot is in a timestamped subfolder.
Further work:
To take transimpedance readings for each PD and create a canonical set of data that can be used to compare with data obtained for every measurement run. |
10210
|
Wed Jul 16 01:27:01 2014 |
Nichin | HowTo | Computer Scripts / Programs | HP8591E spectrum analyzer remote scan |
The script for running continuous scans on HP 8591E spectrum analyzer is located at scripts/general/netgpibdata/HP8591E_contdScan.py
Give the file HP8591E_param.yml as an argument when running the script. This contains the sweep parameters: Start and stop frequencies along with the place where the plot is stored as a PDF.
The default PDF is located on the Desktop and is named HP8591E_View.pdf Open this using okular and then run the script. (Okular pdf viewer automatically reloads the PDF as and when a new one is created)
What the script does:
1) Set the start and stop frequencies as given in the .yml file
2) Take a data trace and plot it in a PDF.
3) Repeat taking traces and update the PDF. Untill Ctrl+C is pressed (PDF refresh rate: approximately every 3 seconds )
4) Exit smoothly after the keyboard interrupt.
Other details:
This spectrum analyzer is connected to a GPIB - Ethernet controller that is configured as santuzza.martian (192.168.113.109)
I have currently stolen the wireless modem from the spectrum analyzer inside the lab (vanna.martian) and using it for this one. *poker face*
To improve:
Get the plot to show where the two biggest peaks are located. Currently it recognizes only the biggest one.
Possibly have makers on the two peaks.
PFA a sample pdf |
10217
|
Wed Jul 16 17:06:41 2014 |
Nichin | Update | Computer Scripts / Programs | HP8591E spectrum analyzer remote scan |
Updated script does the following:
1) Gets the highest 2 peaks
2) Puts a marker on the peaks. Now it looks very similar to the spectrum analyzer display.
3) The refresh rate is still 3 seconds. It might become better if the analyzer was hooked up to a wired martian LAN port rather than the wireless module I am using now.
PFA a sample pdf |
10236
|
Fri Jul 18 15:21:12 2014 |
ericq | Update | Computer Scripts / Programs | Local Chiara backups |
Quote: |
I've also written a backup script at scripts/backup/rsync_chiara.backup which keeps its books in scripts/backup/rsync_chiara.backup.log
I'm adding a entry to the root crontab on chiara to execute the script every day at 7am.
|
I had some syntax errors in the script that prevented the script from doing the right thing. The backup is now up to date, and the cronjob should work. |
10279
|
Sat Jul 26 15:30:15 2014 |
Joseph Areeda | Update | Computer Scripts / Programs | NDS2 server propem on megatron |
The NDS2 server on megatron was unresponsive for what i think was the last couple of days.
The NDS the log file (~nds2mgr/logs/nds2-201407151045.log) started reporting "Stage: parser output queue is full." at 2014.7.24 14:47:54 also there are 16 connections still not closed with LindmeierLaptop.cacr.caltech.edu (131.215.146.102) with 15 of them in CLOSE_WAIT.
To identify these zombie sockets we use "netstat -an | grep 31200"
The server was in a condition that /etc/init.d/nds2 stop didn't work and the process had to be manually kill -9'ed and then about 3 or 4 minutes later the zombie sockets were gone at /etc/init.d/nds2 start was used to restart the server.
The LindemejerLaptop was using pynds to get a bunch of channels at once to test drive a streaming visualization code for glitches. It's unclear whether this bumped into a server limitation. We have seen similar states in ldvw that seem to be the result of errors which result in client-server connections not being closed properly, leaving data in an output buffer causing Linux to wait for the other side to empty the buffer. |
10288
|
Tue Jul 29 18:58:57 2014 |
Nichin | Update | Computer Scripts / Programs | PDFR update and Test run |
The PDFR system's interface and scripts have been updated to include quite a few more features.
On the interface side, there are buttons to open the previous plot for each PD and also a single button to run the scans on all PDs sequentially. The previous plot buttons actually open a softlink that is updated each time a measurement is taken.
Running a scan now pops up a terminal window to show messages that help understand whats going on.

In the background, the script now takes in the transfer function of the demodulator board in ZPK format and calibrates it out of each measurement. The parameters are given .dat files making it easier to replace the transfer function. (Remember my last elog which showed that the fitting of transfer functions were not really great and that I am going to use it anyway to get the script updated.) Also, the script now takes the delay in the RF cables and calibrates out that as well. So we no longer have the huge phase variations and the phase related to transimpedance are visible.
A test run was conducted today. Plots attached.
NOTE: The test can be conducted only on REFL 11,33,55,165 , AS55, and POX11.
POY11 has an optical fiber routed from this system, but there is no space to actually illuminate this PD. So it is currently not included in our system, even though there is a button for this.
POP22 has a fiber illuminating it, but its a unknown broadband PD. I do not know it's DC transimpedance or other values. Its just of matter of updating a few files that feed it's parameters into PDFR.
However, for the above PDs, the demodulator boards have been fit to a transfer function and the script is ready to go as soon as the above problems are fixed.
Conclusion: The plots look noisy. But, the transimpedance now resembles the one on 40-m wiki for all the PDs, both the shape and values.
There will be some errors that are induced because of improper demodulator TF fitting. This has to be taken care of eventually.
Work remaining: Create a canonical set of plots for each PD and set them as the baseline. These canonical plots will be plotted along with each measurement for easy comparison.
A well documented manual for the whole system clearly explaining where and how it takes all the parameters into account so that anybody can easy update just the essential information. |
10292
|
Tue Jul 29 21:34:41 2014 |
ericq | Update | Computer Scripts / Programs | SVN bulletin |
A heads up to anyone using SVN with computers on the Martian network:
When we moved the svn repository on nodus to /export, we set it up such that the internet-facing svn URL was unchanged. However, it turns out that the martian network machines (i.e. Stuff mounted on the NFS share) were still pointing to the old svn files in /cvs/cds/caltech/svn, and thus not seeing new revisions made in /export/home/svn. If your martian network svn'd files got weird, this is why.
I'm relocating the root svn URLs on the martian machines' checkouts to point to the nodus https address as I find them, to make them robust against future local movement of the svn files.
Peoples' user files should be fine, this looks like it'll only really affect things such as scripts and medm screens, etc. |
10305
|
Thu Jul 31 12:01:35 2014 |
Nichin | Update | Computer Scripts / Programs | PDFR update |
The Transimpedance plots of PDFR now have a reference plot or baseline plot along with the current measurement, for easy comparision.
Current Work: Getting Matlab's vectfit3 to work simultaneously on the transimpedance readings and print the zeros and poles alongside the plots. |
10313
|
Thu Jul 31 23:19:22 2014 |
Koji | Update | Computer Scripts / Programs | SVN bulletin |
Did this break "netgpibdata"?
I couldn't download data from SR785. Downloading from AG4395A was OK.
The cause seemed the module for SR785
-rw-rw-r-- 1 controls controls 24225 2014-07-30 18:36 SR785.py
I had a local copy of this file and replaced it with mine. Now netgpibdata start working.
The old one is named SR785.py_bak
-rwxr-xr-x 1 controls staff 12944 Jul 31 23:08 SR785.py
The file size is significantly different from the one we had. |
10323
|
Fri Aug 1 15:32:07 2014 |
ericq | Update | Computer Scripts / Programs | Elog and svn backups |
Koji and Evan have both brought up a good point that we may not be backing up the svn and ELOG properly.
I have modified the rsync.backup script that nodus' cron runs every night that backs up /cvs/cds to what I presume are the tape backups at ldas-cit.ligo.caltech.edu.
Specifically, I added two rsync commands that grab the svn and elog directories from /export/home and copy them to their old locations in /cvs/cds/caltech. This way, the old locations are updated, and the tape backups stay current. |
10332
|
Tue Aug 5 17:24:37 2014 |
Nichin | Update | Computer Scripts / Programs | PDFR update |
The PDFR system now has the capability to automatically run vectfit3.mat using a wrapper script named vectorfitzpk.m
This is done via a shell script being called from inside python that inturn runs the matlab script. |
10346
|
Thu Aug 7 13:39:41 2014 |
Nichin | Update | Computer Scripts / Programs | Wrapping up PDFR |
1)The PDFR scripts have all been migrated into /scripts/PDFR/
2) The MEDM screen to run PDFR is /medm/MISC/PDFR.adl
3) A new button has been added on sitemap to open the above medm window.
4) All data and plots generated will sit in /scripts/PDFR/"PD Name"/
5) All features are working after the migration and absolute file paths are being used.
Work Remaining : Manual for others to make changes and keep using my system.
|
10352
|
Fri Aug 8 14:27:18 2014 |
Akhil | Update | Computer Scripts / Programs | FOL Scripts |
The scripts written for interfacing the FC with R Pi, building EPICS database, piping data into EPICS channels,PID loop for FOL are contained in :
/opt/rtcds/caltech/c1/scripts/FOL
The instructions to run these codes on R Pi( controls@domenica) will be available on FOL 40m wiki page.
Also instructions regarding EPICS installation on R Pi and building an EPICS SoftIoc to streamline data from hardware devices into channels will be updated shortly.
|
10381
|
Wed Aug 13 23:58:49 2014 |
rana | HowTo | Computer Scripts / Programs | HP8591E spectrum analyzer remote scan |
Quote: |
The script for running continuous scans on HP 8591E spectrum analyzer is located at scripts/general/netgpibdata/HP8591E_contdScan.py
|
There was no such script in the directory when I looked today, but I found one called HP8591E. Of course, it didn't run because it hadn't been tested from the scripts directory and pointed to some /users/nichin/ stuff.
I modified a couple of lines and then committed it and the default .YML parameter file to the SVN. It runs and produces plots continuously from the scripts directory.
*** also, as you can see, we have mostly recovered the green beat amplitudes after yesterday's FLL attack on the ALS *** |
10421
|
Thu Aug 21 22:10:52 2014 |
rana | Summary | Computer Scripts / Programs | network movements |
To help development of the data visualization project, we've assigned the .101 and .102 IP to DataVis. This is being used by the iMac in the control room via port 8 of the CDS switch near the Blue Plataeu Tournant.
We tried using one of the free ports, but Jamie realized that we had to use one of the already assigned ones due to some 'Smart' switch management software. So for the moment, please leave the iMac alone so that Bill can use it. |
10456
|
Fri Sep 5 03:36:00 2014 |
rana | Update | Computer Scripts / Programs | martian wireless tweak |
I changed the Martian wireless router to use channel 10 instead of something random (as it was). Using the Android app 'Wifi Analyzer' we could see that the usual channels are dominated by FlumeLab and Caltech Beaver.
The range from 9-13 looked clean so we put it up there. Also, the signal strength drops from -45 to -70 dBm as we walk from the BS down to the ends. We need to tweak the router position and orientation to give us another 10 dB so that we can reliably run the laptops at the ends. |
10467
|
Mon Sep 8 08:24:49 2014 |
Steve | Update | Computer Scripts / Programs | preparing vac system to reboot |
Q and Steve will follow elog 10028 entry to prepare the vacuum system for safe reboot |
10468
|
Mon Sep 8 11:10:26 2014 |
ericq | Update | Computer Scripts / Programs | preparing vac system to reboot |
Quote: |
Q and Steve will follow elog 10028 entry to prepare the vacuum system for safe reboot
|
Here's the sequence of the morning so far:
- I aligned the IFO (IR arms with ASS, X green with PZTs, PRM with PRMI locked on REFL33)
- I closed the PSL shutter, and went inside to align PRM and both ITM oplevs (all others were within 10urad of zero in both directions)
- While aligning those oplevs, I noticed the smell of burnt electronics. We tracked it down to the +15V sorensen in the rack nearest the PSL table
- I claim the precipitating event was PSL shutter activity. If I recall correctly, the seismic rainbow traces went bonkers around the same time as the shutter was closed. There is a Guralp interface in the rack powered by the failed sorensen, so this would explain the erratic seismometer signals correlated with the power supply failure. We will look into potential shorts caused by the shutter. (Steve looked up the PMC trans and Guralp DQ channels, and confirmed the temporal coincidence of the events.)
- We shut off all of the sorensens so that electronics were not being driven asymmetrically.
- Steve and I secured the vacuum system for computer reboots, as referred to in Steve's elog. Some combination of Jenne, Rana and Manasa shut down the control room computers, and turned off the watchdogs.
- Manasa and I moved Chiara inside, next to Mafalda, along with its backup HDs. It has been labeled.
- Booted up control room machines, they came up happy.
- FB and front-ends didn't need reboot, for some lucky reason. Watchdogs came back happily, oplev spots didn't move noticeably.
The IFO is still down, as the PMC won't lock without the rack power, and we haven't pinned down the shorting mechanism. We don't want the replacement sorensen to immediately blow when plugged in. |
10469
|
Mon Sep 8 11:34:47 2014 |
rana | Update | Computer Scripts / Programs | preparing vac system to reboot |
FYI: in that rack, the +15V pulls ~0.5 A more than -15V usually. I think this is due to some RF amplifiers which are powered by this (e.g. the AOM that Manasa set up). The Sorensen's can source ~30A in principle, so we should make sure to set the current limit appropriately so as to not overheat them when there is a short.
Was this power supply not fused for all of its connections? I remember that this was connected to at least one un-fused connection in the past year. |
10470
|
Mon Sep 8 12:11:36 2014 |
manasa | Update | Computer Scripts / Programs | preparing vac system to reboot |
Quote: |
FYI: in that rack, the +15V pulls ~0.5 A more than -15V usually. I think this is due to some RF amplifiers which are powered by this (e.g. the AOM that Manasa set up). The Sorensen's can source ~30A in principle, so we should make sure to set the current limit appropriately so as to not overheat them when there is a short.
Was this power supply not fused for all of its connections? I remember that this was connected to at least one un-fused connection in the past year.
|
+15V supply powers the following (from what I see):
1. PMC and MC boards on the rack.
2. RF amplifiers on the rack for the beat signals from the green beat PDs.
3. Beatbox itself.
The beatbox was the one that had an un-fused connection last year. I re-did it properly to go through a fuse quite sometime ago.
I dont see any other un-fused connections now from the +15V supply right now.
P.S. AOM driver takes a 0 to +28V power supply and not connected to the +15V |
10472
|
Mon Sep 8 15:50:47 2014 |
ericq | Update | Computer Scripts / Programs | +15V PSL Sorensen replaced |
We replaced the +15V sorensen at 1X1, and brought the power supplies back up symmetrically, and everything seems fine. I noted that a quarter turn counter-clockwise took the current limit down by one amp, so I set the knob to just letting 2.8A (the nominal current), and then added one half turn, shooting for ~4A current limit.
In doing so, we had to cut power to the c1psl VME box. It didn't come back happily. We had to do the chiara /etc/hosts things, like we did for c1auxexx, to get it back. |
10473
|
Mon Sep 8 16:23:25 2014 |
Larry | HowTo | Computer Scripts / Programs | accessing 40m data remotely with python |
Attached is an example script showing how to access 40m data remotely. The only two nonstandard python modules you need are the nds2 client module and astropy (used for time conversion). For mac users, both of these are available via macports (nds2-client and, e.g. py27-astropy). Otherwise, check out their websites:
https://www.lsc-group.phys.uwm.edu/daswg/projects/nds-client.html
https://github.com/astropy/astropy
Have fun!
|
10477
|
Tue Sep 9 14:18:40 2014 |
Steve | Update | Computer Scripts / Programs | preparing vac system to reboot |
Quote: |
Quote: |
Q and Steve will follow elog 10028 entry to prepare the vacuum system for safe reboot
|
Here's the sequence of the morning so far:
- I aligned the IFO (IR arms with ASS, X green with PZTs, PRM with PRMI locked on REFL33)
- I closed the PSL shutter, and went inside to align PRM and both ITM oplevs (all others were within 10urad of zero in both directions)
- While aligning those oplevs, I noticed the smell of burnt electronics. We tracked it down to the +15V sorensen in the rack nearest the PSL table
- I claim the precipitating event was PSL shutter activity. If I recall correctly, the seismic rainbow traces went bonkers around the same time as the shutter was closed. There is a Guralp interface in the rack powered by the failed sorensen, so this would explain the erratic seismometer signals correlated with the power supply failure. We will look into potential shorts caused by the shutter. (Steve looked up the PMC trans and Guralp DQ channels, and confirmed the temporal coincidence of the events.)
- We shut off all of the sorensens so that electronics were not being driven asymmetrically.
- Steve and I secured the vacuum system for computer reboots, as referred to in Steve's elog. Some combination of Jenne, Rana and Manasa shut down the control room computers, and turned off the watchdogs.
- Manasa and I moved Chiara inside, next to Mafalda, along with its backup HDs. It has been labeled.
- Booted up control room machines, they came up happy.
- FB and front-ends didn't need reboot, for some lucky reason. Watchdogs came back happily, oplev spots didn't move noticeably.
The IFO is still down, as the PMC won't lock without the rack power, and we haven't pinned down the shorting mechanism. We don't want the replacement sorensen to immediately blow when plugged in.
|
Vacuum safe reboot required one hour of no pumping of the vac envelope. |
10511
|
Tue Sep 16 17:02:41 2014 |
Steve | Update | Computer Scripts / Programs | PSL output shutter is floating |
Quote: |
Quote: |
Q and Steve will follow elog 10028 entry to prepare the vacuum system for safe reboot
|
Here's the sequence of the morning so far:
- I aligned the IFO (IR arms with ASS, X green with PZTs, PRM with PRMI locked on REFL33)
- I closed the PSL shutter, and went inside to align PRM and both ITM oplevs (all others were within 10urad of zero in both directions)
- While aligning those oplevs, I noticed the smell of burnt electronics. We tracked it down to the +15V sorensen in the rack nearest the PSL table
- I claim the precipitating event was PSL shutter activity. If I recall correctly, the seismic rainbow traces went bonkers around the same time as the shutter was closed. There is a Guralp interface in the rack powered by the failed sorensen, so this would explain the erratic seismometer signals correlated with the power supply failure. We will look into potential shorts caused by the shutter. (Steve looked up the PMC trans and Guralp DQ channels, and confirmed the temporal coincidence of the events.)
- We shut off all of the sorensens so that electronics were not being driven asymmetrically.
- Steve and I secured the vacuum system for computer reboots, as referred to in Steve's elog. Some combination of Jenne, Rana and Manasa shut down the control room computers, and turned off the watchdogs.
- Manasa and I moved Chiara inside, next to Mafalda, along with its backup HDs. It has been labeled.
- Booted up control room machines, they came up happy.
- FB and front-ends didn't need reboot, for some lucky reason. Watchdogs came back happily, oplev spots didn't move noticeably.
The IFO is still down, as the PMC won't lock without the rack power, and we haven't pinned down the shorting mechanism. We don't want the replacement sorensen to immediately blow when plugged in.
|
The Uniblitz shutter is insulated at the optical table. I only realized it when it was in my hand. The 3"x2" base plate is black DELRIN !
In the future we must label black Delrin base plate where it is used. Now we have white Delrin and light bran PEEK base plates for the same function. |
10540
|
Thu Sep 25 15:41:15 2014 |
ericq | Update | Computer Scripts / Programs | Rossa having a better day |
I think I found out why rossa was mad.
An apt-get update on the 18th downloaded kernel 2.6.32-65-generic, so 2.6.32-58-generic, which what was previously chosen as a working kernel, had moved down in the grub ordering.
It turns out the grub configuration accepts strings, so I changed it to GRUB_DEFAULT="Ubuntu, with Linux 2.6.32-58-generic", ran sudo update-grub, and Rossa now seems to boot happily. |
10543
|
Fri Sep 26 11:44:55 2014 |
nicolas | Frogs | Computer Scripts / Programs | Loaded larry's fake filter into C1:ALS-OFFSETTER2 |
Larry and Nicolas
Larry's transfer function measurements suddenly started returning 0dB 0degrees when before there was some fake filter in the C1:ALS-OFFSETTER2 filter bank.
We looked in the filter bank and his filter was gone. So I created a new filter called LARRYP in FM2. We also disabled the output so he could drive the filter bank and test his TF code. |
10604
|
Mon Oct 13 21:59:47 2014 |
rana | Update | Computer Scripts / Programs | Which side of optical spring are we on? (No progress) |
Since no one was here, I started the Ubuntu 10 - 12 upgrade on Rossa. It didn't run at first because it wanted to remove 'update-manager-kde' even though it was on the blacklist. I removed it from the command line and now its running. Allegra, OTOH, refuses to upgrade. Someone please ask Diego to wipe it and then install Ubuntu 12 LTS on there in the morning...its a good way to learn the Martian CDS setup. |
10605
|
Tue Oct 14 17:38:31 2014 |
ericq | Update | Computer Scripts / Programs | Rossa and Allegra wiped, Ubuntu 12.04 installed |
When I came in, Rossa was booted to Ubuntu 10. I tried rebooting to select 12, but couldn't ever successfully boot again. Since Diego was setting up Allegra from scratch, I've wiped and done the same with Rossa. |
10606
|
Tue Oct 14 23:44:42 2014 |
diego | Update | Computer Scripts / Programs | Rossa and Allegra wiped, Ubuntu 12.04 installed |
Allegra and Rossa wiped and updated to Ubuntu 12.04.5 by me and Ericq; the following procedure was followed:
1) create "controls" user with uid=1001, gid=1001
2) setup network configuration (IP, Mask, Gateway, DNS), .bashrc, /etc/resolv.conf
3) add synaptic package manager (Ubuntu Software Center used by default)
4) add package nfs-common (and possibly libnfs1) to mount nfs volumes; mount nfs volume adding the line "chiara:/home/cds/ /cvs/cds/ nfs rw,bg 0 0" in /etc/fstab
5) add package firmware-linux-nonfree, needed for graphics hardware recognition (ATI Radeon HD 2400 Pro): due to kernel and xorg-server versions of 12.04.5, and because ATI dropped support for legacy cards in their proprietary driver fglrx the only solution is to keep Gallium drivers
6) add packages libmotif3 grace, needed by dataviewer
7) add repository from https://www.lsc-group.phys.uwm.edu/daswg/download/repositories.html (Debian Squeeze); install lcssoft-archive-keyring as first package or apt-get will complain
8) add package lscsoft-metaio libjpeg62, needed by diaggui/awggui (Ericq: used lalmetaio on rossa)
9) add packages python-numpy python-matplotlib python-scipy ipython
10) change ownership of /opt/ to controls:controls
11) add csh package
12) add t1-xfree86-nonfree ttf-xfree86-nonfree xfonts-75dpi xfonts-100dpi, needed by diaggui/awggui (needs reboot)
13) add openssh-server
Ubuntu creates the first user during installation with uid=1000 and gid=1000; if needed, they could be changed afterwards using a second user account and the following procedure (twice, if the second users gets the 1001 uid and gid):
sudo usermod -u <NEWUID> <LOGIN>
sudo groupmod -g <NEWGID> <GROUP>
sudo find /home/ -user <OLDUID> -exec chown -h <NEWUID> {} \;
sudo find /home/ -group <OLDGID> -exec chgrp -h <NEWGID> {} \;
sudo usermod -g <NEWGID> <LOGIN> |
10611
|
Wed Oct 15 17:18:10 2014 |
Jenne | Update | Computer Scripts / Programs | Dataviewer fix with Ubuntu 12.04 |
I have modified the Dataviewer launcher (which runs when you either click the icon or type "dataviewer" in the terminal).
A semi-old problem was that it would open in the file /users/Templates, but our dataviewer templates start in /users/Templates/Dataviewer_Templates. Now this is the folder that dataviewer opens into. This was not related to the upgrade to Ubuntu 12, but will be overwritten any time someone does a checkout of the /ligo/apps/launchers folder.
A problem that is related to the Ubuntu 12 situation, which we had been seeing on Ottavia and Pianosa for a few weeks, was that the variable NDSSERVER was set to fb:8088, which is required for cdsutils to work. However, dataviewer wants this variable to be set to just fb. So, locally in the dataviewer launcher script, I set NDSSERVER=fb. NB: I do not export this variable, because I don't want to screw up the cdsutils. This may need to be undone if we ever upgrade our Dataviewer. |
10628
|
Tue Oct 21 17:44:28 2014 |
jamie | Omnistructure | Computer Scripts / Programs | new version of cdsutils (351) installed |
I just installed cdsutils r351 at /ligo/apps/linux-x86_64/cdsutils. It should be available on all workstations.
It includes a bunch of bug fixes and feature improvements, including the step stuff that Rana was complaining about. |
10655
|
Thu Oct 30 16:25:22 2014 |
ericq | Omnistructure | Computer Scripts / Programs | new version of cdsutils (361) installed |
Quote: |
I just installed cdsutils r351 at /ligo/apps/linux-x86_64/cdsutils. It should be available on all workstations.
It includes a bunch of bug fixes and feature improvements, including the step stuff that Rana was complaining about.
|
Cdsutils r361 installed, for the "avg" updates. aLOG
|
10667
|
Tue Nov 4 19:17:53 2014 |
ericq | Update | Computer Scripts / Programs | Anaconda + CDSutils |
I've fallen down the rabbit hole of trying to reconcile our desire for newer versions of the Numpy and Scipy python packages with the use of our handy cdsutils tools.
I've set up an installation of Anaconda python in /ligo/apps/anaconda . Installing pyepics, nds2, and cdsutils was straightforward, but there were a myriad of odd python packages that cdsutils depends on, that are typically installed at the OS level (python-gst, gobject, glib) which I just manually copied over to the anaconda directories. Also, the version of readline that anaconda ships with is somewhat borked (dark voodoo fix was found here: github link. The issue mentioned there wasn't why I needed the fix. Somehow libreadline was causing pyepics initialization to fail).
I was initially hoping this kind of exercise would be useful, as having a separate python environment that we control buffers us from the system installation and allows us to use whatever version of packages we want, but the amount of hackery I did to get to get cdsutils to work probably didn't result in the most robust solution. (Maybe there was a better way!)
In any case, I have not changed any of our machines' default paths or environment variables. Instead, I have simply created an alias that points to Anaconda python: "apython "
Example:
controls@pianosa|scriptTesting > cat foo.py
import scipy as sp
import sys
from ezca import Ezca
ez=Ezca()
print 'Python Version: '+ sys.version
print 'ez.read test:' + str(ez.read('LSC-TRY_OUT16'))
print 'Scipy Version: '+sp.__version__
controls@pianosa|scriptTesting > python foo.py
Python Version: 2.7.3 (default, Feb 27 2014, 19:58:35)
[GCC 4.6.3]
ez.read test:0.0154613731429
Scipy Version: 0.9.0
controls@pianosa|scriptTesting > apython foo.py
Python Version: 2.7.8 |Continuum Analytics, Inc.| (default, Aug 21 2014, 18:22:21)
[GCC 4.4.7 20120313 (Red Hat 4.4.7-1)]
ez.read test:0.00307549210265
Scipy Version: 0.14.0
Thus, Diego should now be able to complete his script that needs the newer Scipy, as well as CDSutils.
Final note: I've tested z (read|write|avg) with $PATH modified to have /ligo/apps/anaconda/bin at the start, and they seem to work. If things seem to hold up, maybe we can replace the default command-line python, but its not strictly necessary. |
10688
|
Sat Nov 8 11:31:51 2014 |
rana | Update | Computer Scripts / Programs | Anaconda + CDSutils |
Quote: |
I've fallen down the rabbit hole of trying to reconcile our desire for newer versions of the Numpy and Scipy python packages with the use of our handy cdsutils tools.
|
Avoid rabbit holes! What I did at LLO which works is to install an Anaconda in some shared directory and then just make an alias which puts that directory at the head of the path when running the more advanced SciPy installs. It works fine and cannot interfere with our usual operation since its only sourced when running peak find. |
10697
|
Tue Nov 11 19:46:35 2014 |
diego | Update | Computer Scripts / Programs | Status of the new nodus |
The new nodus machine is being brought to life; until installation is finished and everything is fine, the old nodus will be unharmed. For future reference:
New Nodus hardware:
Case: SuperMicro SC825MTQ-R700U
M/B: SuperMicro X8DTU-F
CPU: 2x Intel Xeon X5650
RAM: 3x Kingston KVR1333D3S8R9S (2GB)
3x Samsung M393B5673EH1-CH9 (2GB)
Total 12 GB
HDD: Seagate ST3400832AS (400GB)
Current software situation and current issues :
1) Ubuntu Server 12.04.5 is installed and updated
2) The usual 'controls' user is present, with UID=1001 and GID=1001
3) Packages installed: nfs-common, rpcbind, ntp, dokuwiki, apache2, php5, openssh-server, elog-2.8.0-2 [from source], make, gcc, libssl-dev [dependencies for elog], subversion
4) Network: interface eth0 is set up (static IP and configuration in /etc/network/interfaces); eth1 is recognized and added, but not configured yet
5) DNS: configuration is in /etc/resolvconf/resolv.conf.d/base (since /etc/resolv.conf is overwritten by the resolvconf program using the 'base' database)
6) ntp is installed and (presumably) configured, but ntpd misbehaves (namely, all the servers are found, but a
tail /var/log/syslog
shows that no actual synchronization is performed, and the daemon keeps
Listening on routing socket on fd #22 for interface updates
7) dokuwiki apache2 php subversion elog are installed but not configured yet (I need info about their current state, configuration and whereabouts)
8) I copied and merged the old nodus' .bashrc and .cshrc into new nodus' .bashrc, need to know if something has to be added
9) backup frames, backup user dirs and 40m public_html are not set yet, as in #7
Is there something missing?
If there is something missing from here (ligo/cds software, smartmontools/hddtemp and similar, or anything else) tell me and I'll set them up. |
10751
|
Wed Dec 3 21:41:12 2014 |
Jenne | Update | Computer Scripts / Programs | Matlab license updated |
It seems that the old Matlab servers went down a week or so early, so I have updated the Matlab license information in
/cvs/cds/caltech/apps/linux64/matlab/licenses/
per the instructions on https://www.imss.caltech.edu/content/updating-matlab-license-file
EDIT: Q did this also for the control room iMac |