  7370   Mon Sep 10 18:42:33 2012 Jenne, Mike J.UpdateCamerasXY beam scan tomorrowWe tweaked the mirror on the AP table to
go through the center of the lens in order
to get a more circular beam, but it seemed
  
  7375   Wed Sep 12 17:02:00 2012 SteveUpdateCamerasbaffle plate hole getting larger

    

       
            
 IMG_1631.JPGIMG_1628.JPG 
  7569   Wed Oct 17 18:41:27 2012 JenneUpdateCamerasCamera looking at ETMY baffleThe camera titled "watec_mobile"
is looking at the front of the black glass
baffle (i.e. the side facing the ITM) on
  
  7576   Thu Oct 18 15:36:57 2012 SteveUpdateCamerasWatec cameras & Tamron lensesI purchased 3x  1/2"
ccd cameras and 3x  F  50
mm lenses for the lab.
 10181201.PDF 
  7685   Wed Nov 7 19:07:45 2012 JenneUpdateCamerasNo beam seen on external camera viewsI have written some scripts which collect
photos, then average them together, and subtract
out an averaged background (as Rana described
 BS_PRM_7Nov2012_SpotImage_pixelsTimes3.pngETMXF_7Nov2012_SpotImage_pixelsTimes3.pngETMYF_7Nov2012_SpotImage_pixelsTimes3.pngITMYF_7Nov2012_SpotImage_pixelsTimes3.pngMC2F_7Nov2012_SpotImage_pixelsTimes3.png 
  7687   Thu Nov 8 09:04:45 2012 SteveUpdateCamerasCanon T3i purchasedCanon
EOS Rebel T3i has been purchased. See
rating
 BH_409130400.pdf 
  7700   Tue Nov 13 00:19:51 2012 JenneUpdateCamerasITMX is just fine

    

       
            
  
  7729   Mon Nov 19 23:14:31 2012 EvanUpdateCamerasETMYF focusAdjusted focus on ETMYF camera so that
the IR beam is in focus.
  
  9443   Thu Dec 5 11:06:43 2013 SteveUpdateCameras viewport video ccd cameras are all covered

    

       
            
 PRMcamera.jpgPRMcameraCover.jpgFaradayCameraCover.jpg 
  10259   Wed Jul 23 10:39:18 2014 SteveUpdateCamerasvideo quad processors replacedQuad
processor 2 & 3 were replaced.
  
  11083   Fri Feb 27 10:25:24 2015 steveUpdateCamerasquad picture problemMUX input 7 to ITMXF camera cable was replaced
by temporary cable labeled as 888

The problem remains to be the same
 quadMUX.jpg 
  11129   Tue Mar 10 19:59:13 2015 KojiFrogsCamerasMessage from the IFO   IMG_1825.JPG 
  11851   Sat Dec 5 12:02:25 2015 yutaroHowToCamerasWhen image capture does not work...Today image capture did not work again,
though it had worked 3 days before. I also
found that red indicator light on the
  
  11852   Sat Dec 5 21:28:33 2015 KojiHowToCamerasWhen image capture does not work...Do we need "make" everytime?
Do you mean just running "modprobe"
didn't work?
  
  11853   Sat Dec 5 21:57:32 2015 yutaroHowToCamerasWhen image capture does not work...I don't know if just running "modprobe"
will work or not, because I didn't try
it...  When the same problem happens
  
  12617   Tue Nov 15 20:26:35 2016 JohannesUpdateCamerasBasler GigE-Camera on Optimus (+Mafalda dead)I powered up the existing ace100gm GigE
cam with the PoE injector and tried to interface
with it as described in elog
 gige_test.png 
  12622   Thu Nov 17 12:14:21 2016 ranaUpdateCamerasBasler GigE-Camera on Optimus (+Mafalda dead)Indeed. I suggest discussing with Joe B.
I believe we should use a dedicated cam network
to get the camera signals from the ends and
  
  12937   Mon Apr 10 16:00:26 2017 rebeccaUpdateCamerasPylon installation warningWhen trying to install an older version
of Pylon packaged for Debian that Joe B.
had sent, it gave the warning that the package
  
  12938   Mon Apr 10 18:42:09 2017 johannesUpdateCamerasPylon installation warningIt looks like we may not need to use this
old Pylon version after all. Gautam and I
looked into installing SnapPy with the makefile
  
  12953   Thu Apr 27 17:55:33 2017 SteveUpdateCameraswhich camera to use for IR scatterring picturesYesterday I failed to take good pictures
of ETMY  resonant arm of 1064 nm with
Cannon Rebel T3i in RAW 22-27Mp & JPG
 P4270081RAWolym.jpgImg0344.jpg 
  12956   Fri Apr 28 18:01:56 2017 rebeccaUpdateCamerasAttempting to Load Camera ClientUsing /ligo/apps/linux-x86-64/camera/bin/camera_client.py
-c  /opt/rtcds/caltech/c1/scripts/GigE/SnapPy/L1-CAM-MC1.ini,
the Python script was able to run without
  
  12958   Fri Apr 28 22:50:35 2017 johannesUpdateCamerasAttempting to Load Camera ClientYou'll likely have to run camera_server.py
using the same ini file first before you
can use the client. Since the pylon installation
  
  12959   Sun Apr 30 13:24:00 2017 ranaUpdateCamerasAttempting to Load Camera ClientWe ought to put the camera software on
the shared disk; I don't think there's
any speed reasons that it needs to be local.
  
  12961   Mon May 1 17:14:58 2017 SteveUpdateCamerasETMY & MC2 ccd cameras removedMC2 ccd camera is replaced by Olympus 570
zoom temporarly.

So as the ETMY ccd camera is replaced
  
  12973   Fri May 5 08:41:42 2017 SteveUpdateCamerasMC2 resonant picturesOlympus SP570 UZ - without  IR blocker,
set up as Atm.3  Camera distance to
MC  face ~85 cm,  IOO-MC_TRANS_SUM
 P5040028MC2c.jpgIMG_3682.JPGIMG_3688.JPG 
  12989   Fri May 12 18:45:04 2017 rebeccaUpdateCamerasMC2 Pics with OlympusRaw and JPG formats of the pictures are
saved on the Mac in the control room and
at this link:
  
  12996   Wed May 17 11:10:31 2017 SteveUpdateCamerasMC2 CCD video camera back in placeOlympus camera is removed and our old CCD
camera is back to monitor the face of MC2

  
  13020   Tue May 30 17:45:35 2017 jigyasaSummaryCamerasGigE configuration To verify the Pylon Installation on the
shared drive, I tried connecting the Basler
acA640-100gm to the PoE connector and running
 GigEconfiguration.pdf 
  13024   Wed May 31 18:17:28 2017 jigyasaSummaryCamerasGigE configuration This evening I was able to obtain some
images with the same lens on the GigE. 
The problem earlier, as Johannes pointed
 PictureswithPylon.pdf 
  13025   Wed May 31 19:18:53 2017 jigyasaSummaryCamerasGigE configuration And here's another picture of Kaustubh,
my fellow SURF, captured in all his glory
by Rana! :)
 Image__2017-05-31__18-49-37.bmp 
  13027   Thu Jun 1 15:33:39 2017 jigyasaUpdateCamerasGigE installation in the IFO areaI tried to
capture some images with the GigE inside
the Interferometer area in the 40m today.
 HOMMC2.pdf 
  13029   Thu Jun 1 16:14:55 2017 jigyasaUpdateCamerasGigE installation in the IFO areaThanks to Steve and Gautam, the IMC was
locked.

I was able to capture images with
 MC2.pdf 
  13031   Thu Jun 1 20:16:11 2017 ranaUpdateCamerasGigE installation in the IFO areaGood installation. I think the images are
still out of focus, so try to resolve into
some small dots at the low exposure setting.
  
  13040   Mon Jun 5 12:27:34 2017 jigyasaUpdateCamerasAttempt to run camera server Python codeWhile attempting
to execute the Python/Pylon code for the
camera server, camera_server.py, the compiler
  
  13041   Mon Jun 5 12:50:42 2017 jigyasaUpdateCamerasAttempt to run camera server Python codeI think there
might be a problem with the fact that
the installation of the various components
  
  13042   Mon Jun 5 15:04:33 2017 ranaUpdateCamerasAttempt to run camera server Python codeRight - we want to be compatible with new
version of the code, so instead of moving
the files to where the code wants them you
  
  13043   Mon Jun 5 18:40:12 2017 jigyasaUpdateCamerasAttempt to run camera server Python code[Gautam, Jigyasa]

This
evening, Gautam helped me resolve the
  
  13045   Tue Jun 6 09:14:26 2017 SteveUpdateCamerasGigE installation at MC250mm
1.8 lens with
Basler camera at MC2 face with micro
 MC2.jpg 
  13054   Fri Jun 9 09:13:26 2017 SteveUpdateCamerasGigE camera lens with AR We should move on with getting this
lens from Edmonds #67-717  at 1064
R<3% 
 coating_curve.pdf 
  13070   Fri Jun 16 18:21:40 2017 jigyasaConfigurationCamerasGigE camera IP One of the additional GigE cameras has been
IP configured for use and installation. 

Static IP assigned to the camera-
  
  13074   Tue Jun 20 14:58:08 2017 SteveUpdateCamerasGigE camera at ETMXGigE can be connected to ethernet. AR coated
1064 f50 can arrive any day now.

 ETMXgige.jpg 
  13083   Tue Jun 27 16:18:59 2017 jigyasaUpdateCamerasGigE camera at ETMXThe 50mm lens has arrived. (Delivered yesterday).

Also the GigE has been wired and
conencted to the Martian. Image acquisition
  
  13089   Fri Jun 30 11:08:26 2017 jigyasaUpdateCamerasGigE camera at ETMX
With Steve's help in
 PicturesETMX.pdfdirtyETMXwindow.jpg 
  13091   Fri Jun 30 15:25:19 2017 jigyasaUpdateCamerasGigE camera at ETMXAll thanks to Steve, we cleaned the view
port on the ETMX on which the camera is installed,
and with a little fine tuning of the focus
 Image__2017-06-30__15-10-05.pdf14ms.pdf 
  13092   Fri Jun 30 16:03:54 2017 jigyasaUpdateCamerasGigE camera at ETMX 




 14msexposure.png 
  13098   Thu Jul 6 11:58:28 2017 jigyasaUpdateCamerasHDR images of ETMXI captured a few images of the beam spot
on ETMX at 5ms, 10ms, 14ms, 50ms, 100ms,
500ms, 1000ms exposure and ran them through
 ETMXHDRcolormap.pngETMXHDRimage.png 
  13100   Fri Jul 7 14:34:27 2017 ranaUpdateCamerasHDR images of ETMXi wonder how 'HDR' these images
really are. is there a quantitative way to
check that we are really getting more bits?
  
  13118   Sat Jul 15 01:28:53 2017 jigyasaUpdateCamerasBRDF CalibrationsThis evening,
Gautam helped me with setting up the apparatus
for calibrating the GigE for BRDF measurements.
  
  13119   Sat Jul 15 13:40:59 2017 ranaUpdateCamerasBRDF CalibrationsPower meter only needed to measure power
going into the paper not out. We use the
BRDF of paper to estimate the power going
  
  13120   Sat Jul 15 16:19:00 2017 gautamUpdateCamerasMakeshift PyPylonSome days ago, I stumbled upon
this github page, by a grad student at
KIT who developed this code as he was
 pyPylon_test.png 