40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 65 of 344  Not logged in ELOG logo
IDup Date Author Type Category Subject Text Attachments
  3228   Thu Jul 15 15:57:10 2010 KojiConfigurationLSCPRC and SRC length adjustementsTell me whether it is correct or not. Otherwise
I won't be able to sleep tonight.

  
  3229   Thu Jul 15 16:16:51 2010 AlbertoConfigurationLSCPRC and SRC length adjustements


   
        
            
  
  3230   Thu Jul 15 16:57:31 2010 josephb, kiwamuUpdateCDSThe temporarily named c1scx machine getting ready to connect to IO chassisThis is the machine which will be the new
x end front end machine.  Its IP is
192.168.113.86. 
  
  3231   Thu Jul 15 19:13:03 2010 ranaUpdateIOOMC_F checkSometimes I like to plot the spectrum of
MC_F. Its a good diagnosis of whether something
is wrong.
 a.png 
  3232   Thu Jul 15 19:27:04 2010 ranaSummaryPSLRC trend after the insulation removal   Untitled.pnga.pngb.png 
  3233   Thu Jul 15 23:51:47 2010 Mr. MaricHowToSUSLevitate me if you canYou guys must work harder.
 mag_lev.jpg 
  3234   Fri Jul 16 12:36:00 2010 Katharine, SharmilaUpdateeloglevitationAfter last night's challenge (or inspiration),
we levitated our magnet this morning. 
Since the nice Olympus camera is not currently
 CIMG0649.AVI 
  3235   Fri Jul 16 13:05:48 2010 Kyung-haUpdateSUSLate update for 7/13 Tue (Tip Tilts)[Jenne & Kyung-ha]
We suspended the mirror to one of
the main frame with the ECD backplane we
  
  3236   Fri Jul 16 15:39:27 2010 nancyUpdateIOOWavefront Sensors- switched offI tuned the gain of WFS to 0 last night
at about 3am.
I turned it back on now.
  
  3237   Fri Jul 16 15:57:19 2010 josephb,kiwamuUpdateComputersNew X end FE and IO chassis workWe finished setting up the new X end front
end machine (still temporarily called c1scx),
and attached it to its IO chassis. 
  
  3238   Fri Jul 16 16:07:14 2010 josephbUpdateComputersPossible solution for the last ADC After talking with Jenne, I realized the
ADC card in the c1ass machine was currently
going unused.  As we are short an ADC
  
  3239   Fri Jul 16 16:12:31 2010 AlbertoConfigurationComputersc1susvme1/2 rebootedToday I noticed that the FE SYNC counters
of c1susvme1/2 on the RFM network screen
were stuck at 16384. I tried to reboot the
  
  3240   Fri Jul 16 20:25:52 2010 MeganUpdatePSLReference Cavity InsulationRana and I
1) took the temperature sensors off
the reference cavity;
 DSC_2271.JPGDSC_2266.JPG 
  3241   Fri Jul 16 23:53:27 2010 RanaUpdatePSLReference Cavity InsulationFrom the trend, it seems that the Reference
Cavity's temperature servo is working fine
with the new copper foil. I was unable to
  
  3242   Sun Jul 18 20:50:03 2010 ranaConfigurationIOOMC TRANS optics changedTo make the beam on the MC trans camera
bigger, I removed the lens + ND filter that
was in that path.
  
  3243   Mon Jul 19 13:51:09 2010 kiwamuUpdateCDSTIming card at X end[Joe, Kiwamu]
 
 The timing slave in the IO
  
  3244   Mon Jul 19 14:14:03 2010 nancy, kojiUpdateIOOQPD Response Transfer FunctionFriday night myself and Koji measured the
Transfer function of the QPD circuit at MC2
side using a chopper . Following was our
  
  3245   Mon Jul 19 14:16:01 2010 nancy, kojiUpdateIOOQPD Response Transfer Function

    
        
 QPDTF2.png 
  3246   Mon Jul 19 16:11:17 2010 GopalUpdateOptic StacksEigenfrequency Analysis of Full StackExpanding on the single-layer model, I
added the second, third, and fourth layers
to the stack in COMSOL. Eigenfrequency
 Eigenfrequency_1_4Stacks.pngEigenfrequency_2_4Stacks.pngEigenfrequency_3_4Stacks.pngEigenfrequency_6_4Stacks.png 
  3247   Mon Jul 19 21:47:36 2010 ranaSummaryDAQDAQ timing testSince we now have a good measurement of
the phase noise of the Rb clock
Marconi locked to the Rb clock, I wanted
  
  3248   Tue Jul 20 08:04:31 2010 steveConfigurationVACslow vent has startedThe PSL shutter was closed. The beam path 
blocked two places. High voltage power supplies
to IOO and OMC PZT were checked to be off.
  
  3249   Tue Jul 20 11:49:31 2010 JenneUpdateSUSSome Suspensions not damping[Jenne, Koji]
I moseyed into the control room this
morning, to find ITMX and ITMY both with
  
  3250   Tue Jul 20 11:55:15 2010 Sharmila,KatharineUpdateelogMaglevWe plotted the transfer functions for the
maglev control circuit and compared them
with the plots from the spectrum 
 tf.pngP7140292.JPG 
  3251   Tue Jul 20 15:06:48 2010 josephb, bobOmnistructureGeneralNew speakers in ceiling in control roomAfter the crane training, Bob attached
speakers to the ceiling right next to the
projector, for use with presentations.
  
  3252   Tue Jul 20 17:38:16 2010 GopalConfigurationOptic StacksStack Type ClarificationsSome clarification is warranted regarding
the different shapes of stacks. Corrections
  
  3253   Tue Jul 20 18:29:43 2010 nancyUpdateIOOQPD installed behind the MC2 
Yesterday I installed teh QPD on
the table behind MC2, and observed teh signal
  
  3254   Tue Jul 20 23:52:36 2010 kiwamuUpdateVACupdate: slow vent has startedThe
vent is still going on. At this moment the
pressure inside of the chambers is about
 untitled.png 
  3255   Wed Jul 21 11:57:59 2010 GopalUpdateWIKI-40M Update7.14.10-7.21.10 Weekly UpdateSummary of this week's activities:
7/14: Analytical calculation of Viton
spring constant; updated Viton values in
  
  3256   Wed Jul 21 12:03:14 2010 Katharine, SharmilaUpdateWIKI-40M Updateweekly updateThis past week, we levitated our small
cylindrical magnet (with the flag made from
heat shrink).  Though the levitated
  
  3257   Wed Jul 21 12:20:29 2010 josephb, kiwamuUpdateComputersMegatron temporarily disconnected, c1iscex firewalled, green FE testWe are moving towards a first test of getting
Kiwamu's green locking signals into the new
front end at the new X end, as well as sending
  
  3258   Wed Jul 21 12:20:58 2010 RazibUpdatePhase CameraWeekly updateThis past week I have worked on the following:
1. Setting up the infrastructure
to do noise analysis: We added a temporary
 phase_cam_setup_21_07_2010.jpg 
  3259   Wed Jul 21 12:41:31 2010 kiwamuUpdateVACvent finishedThe vent
has been finished successfully in this morning.
  
  3260   Wed Jul 21 15:43:38 2010 MeganSummaryPSLCopper Layer Thickness on the Reference CavityUsing the equation for thermal resistance
Rthermal = L/(k*A)
where k is the thermal conductivity
  
  3261   Wed Jul 21 17:41:17 2010 GopalConfigurationOptic StacksPictures of StacksNow that venting is complete, this is a
request for anyone who opens any chamber:
1) Please notify me immediately
  
  3262   Wed Jul 21 19:11:18 2010 DmassUpdateGreen LockinglockedWhat did you use to filter the 2f components
from your error signal? A homemade low pass
or what?
  
  3263   Thu Jul 22 01:02:08 2010 ranaUpdateTreasureMonsters, LNVR, and Phase noiseOn
Picasa
  
  3264   Thu Jul 22 03:08:27 2010 KojiUpdateIOOVent and MC lockSummary

- The vacuum chambers have been vented.
  
  3265   Thu Jul 22 07:19:56 2010 AlbertoUpdateTreasureMonsters, LNVR, and Phase noise


   
        
            
  
  3266   Thu Jul 22 08:07:27 2010 steveUpdateVACvent finished

    
        
 30hvent.jpg 
  3267   Thu Jul 22 13:44:47 2010 JennaUpdatePEMGuralp seismometerOne of the Guralps [Gur2] has been taken
to the atf gyro lab, along with the breakout
box.
  
  3268   Thu Jul 22 14:07:20 2010 kiwamuUpdatePSLPSL front end machineIt
looks like something wrong happened around
the PSL front end.  One
 PSL-PMC2010-07-22.png 
  3269   Thu Jul 22 15:59:29 2010 AlbertoUpdatePSLPSL front end machine


   
        
            
  
  3270   Thu Jul 22 18:18:54 2010 AlbertoUpdatePSLProblem Solved


   
        
            
  
  3271   Fri Jul 23 00:13:11 2010 ranaUpdatePSLProblem NOT REALLY SolvedSo...who was working around the PSL rack
this morning and afternoon? Looks like there was
  
  3272   Fri Jul 23 08:15:59 2010 steveUpdatePSLref cavity ion pumpThe ref cavity ion pump was running at
7.7kV instead of 5kV
This Digitel SPC-1 20 l/s ion pump
  
  3273   Fri Jul 23 08:18:03 2010 josephbUpdateCDSNot enough room in IO chassis for RFM card - need to swap PMC to PCIe adaptersThe End IO chassis have small trenton boards,
which apparently only have 5 usuable PCI
slots, even though there are 6 on the board.
  
  3274   Fri Jul 23 10:16:44 2010 josephbUpdateCDSRerouted RFM around c1lsc, took RFM card out of c1lsc I re-routed around the c1lsc machine
this morning.  I turned the crate off,
and disconnected the transmission fiber from
  
  3275   Fri Jul 23 12:33:51 2010 josephbUpdateCDSmegatron, c1iscex, c1sus firewalledKiwamu and I strung an ethernet cable from
the new 1X7 rack to the 1X3 rack. The cable
is labeled c1iscex-daq on both ends. 
  
  3276   Fri Jul 23 14:26:01 2010 GopalUpdateOptic StacksSimple Frequency Response Measurements in COMSOLOver the past couple days, I discovered
a simple, direct method for calculating
frequency responses with a combination
  
  3277   Fri Jul 23 15:32:02 2010 steveUpdatePEMcontrol room AC set point changedThe control room temp is warmer than usual.
The heat exchanger Office Pro 18 set point
was lowered from 70 to 68F yesterday.
  
ELOG V3.1.3-