40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 60 of 341  Not logged in ELOG logo
ID Date Author Typeup Category Subject Text Attachments
  10324   Fri Aug 1 18:48:46 2014 AkhilSummaryElectronicsPZT Calibration 
 The PZT actuation on the laser
frequency in MHz/V ( assuming the previous
  
  10343   Thu Aug 7 11:57:59 2014 KojiSummaryIOOMC servo analysisLISO Fit for the IMC open loop TF. The
data and liso source for the fitting were
attached in the ZIP file.
 MC_OLTF_Fit.pdfIMC_OLTF.zipMC_OLTF_estimated.pdf 
  10350   Fri Aug 8 11:22:35 2014 steveSummarySUSoplev laser summary 
         
        2005             
  
  10351   Fri Aug 8 12:39:19 2014 ericqSummaryIOOMC servo analysisI have measured the current boosted MC
CLG below 100kHz with an SR785. Swept sine
only could get me down to 10kHz, but I was
 mcLoopAug8.zipMCloopAug8.pdf 
  10354   Fri Aug 8 15:57:29 2014 ericqSummaryIOOMC servo analysis I did some further measurements,
to try and see what corresponds to what.
In the end I performed four measurements:
 OLTFs.pdfCLTFs.pdfmcLoopAug8.zip 
  10356   Fri Aug 8 18:08:12 2014 KojiSummaryIOOMC servo analysisThe closed gain I meant is the AO path:
Use IN2 to excite the MC loop and measure
IN1 using MON2(?). 
  
  10359   Sat Aug 9 14:35:28 2014 KojiSummaryIOOMC servo analysisEric's OLTF turned out consistent with
the AO path TF that has been measured by
me on Jul 31 (entry
 MC_OLTF_Fit.pdfliso.zipMC_CLTF_Fit.pdfMC_CLTF_new.pdfMC_OLTF_new.pdf 
  10362   Mon Aug 11 10:23:39 2014 steveSummarySUSoplev laser summary updated

    

       
            
  
  10363   Mon Aug 11 21:03:48 2014 ericq, ranaSummaryIOOMC demod measurementWe measured
the TF of the MC Demod board today. 
  
  10364   Mon Aug 11 22:07:31 2014 KojiSummaryIOOMC demod measurementSCLF-5!? It's surprising as the cut off
of the OLTF is just above 1Hz. cf
this entry
  
  10365   Mon Aug 11 23:32:54 2014 ericqSummaryIOOMC demod measurementHere's the magnitude plot of the board
TF. As mentioned above, this was done with
Marconi+Scope, so we were not able to get
 MCDemod.pdfdemodLP.txt 
  10396   Thu Aug 14 22:58:59 2014 rana, jenneSummaryGreen LockingALS DIFF tuning We've been having trouble tuning
the ALS DIFF matrix. Trying to see if the
MC2 EXC can be cancelled in ALS DARM by adjusting
 sweep.pdf 
  10397   Thu Aug 14 23:19:49 2014 ranaSummaryLSCETM Violin fundamental filters moved to LSC We used to do violin mode and test
mass body mode notches in the SUS-LSC filter
modules. Now we want them balanced in the
 01.png03.png 
  10406   Mon Aug 18 09:42:50 2014 KojiSummaryIOOMCREFL PD charcterizationRiju did the
measurement of the MCREFL PD.
I found data files in her directory
 MCREFLPD_transimpedance.pdfMCREFLPD_transimpedance_zoom.pdf 
  10421   Thu Aug 21 22:10:52 2014 ranaSummaryComputer Scripts / Programsnetwork movements To help development of the data visualization
project, we've assigned the .101 and .102
IP to DataVis. This is being used by the
  
  10424   Fri Aug 22 15:11:55 2014 andres, nicolasSummaryIOOMC WFS activity1. Before doing anything, we centered the
IOO QPDs.
2. With the WFS enabled, we offloaded
  
  10425   Fri Aug 22 15:58:02 2014 SteveSummaryIOOMC WFS activity 
 
 GoyphaseSet.png 
  10442   Tue Sep 2 22:54:27 2014 KojiSummaryLSCphase tracker UGFFYI and FMI
Phase tracker UGF is  Q_AMP
* G * 2 PI / 360 where Q_AMP is
  
  10454   Thu Sep 4 18:30:13 2014 GabrieleSummaryASCOptimal Gouy phase for POP QPD Jenne asked me to simulate the signals
on POP QPD when moving different mirrors,
as a function of the Gouy phase where the
 pop_qpd_dc.pngfortymeters.mistfortymeters_pop_qpd.mistpop_qpd.m 
  10455   Fri Sep 5 00:56:00 2014 ranaSummaryOptical LeversITM OLs recentered: violations foundI re-centered the ITMX & ITMY Optical
lever beams today since they were off. First
I aligned the beam into the vacuum so that
  
  10492   Wed Sep 10 22:17:29 2014 KojiSummaryLSCX/Y green beat mode overlap measurement[Koji Manasa]
We made quantitative inspection of
the X/Y green beat setup on the PSL table.
  
  10518   Thu Sep 18 10:08:07 2014 steveSummarySUSoplev laser summary updated 




  
  10694   Mon Nov 10 23:14:20 2014 ranaSummarySUSSRM: damping gains & Optical Lever servo Tune-up
     tweaked gains for POS,
PIT, YAW, SIDE by ~10-20% to get nice ringdowns
with Q~5.
    Measured bounce rool
 SRM-BR.pdfSRM_err_141110.pdfSRM-OLG.pdf 
  10706   Wed Nov 12 22:22:11 2014 KojiSummaryIOOEstimation of the angular jitter imposed by the TTs[Koji, Rana, Jenne]
One coil of the TT produce 36nrad/rtHz
at DC.
 03.png 
  10722   Mon Nov 17 20:28:17 2014 ranaSummaryIOOMC servo summing ampI modified the /cvs/cds/caltech/target/c1psl/psl.db
file to adjust the records for the FSS-FAST
signal (to make it go yellow / red at the
  
  10760   Sun Dec 7 13:11:57 2014 manasaSummaryGeneralFrequency Offset Locking - To Do ListAttached is the timeline for Frequency
Offset Locking related activities. All activities
will be done mostly in morning and early
 FOLtodolist.pdf 
  10765   Mon Dec 8 15:54:39 2014 manasaSummaryGeneralDec 8 - Check Frequency Counter module

    

       
            
  
  10766   Mon Dec 8 20:53:51 2014 diegoSummaryGeneralDec 8 - Check Frequency Counter module

    

       
            
  
  10767   Tue Dec 9 00:30:27 2014 manasaSummaryGeneralDec 9 - Elaborate to do list

    

       
            
 FOL_FiberChassis.pdf 
  10770   Tue Dec 9 16:06:46 2014 diegoSummaryGeneralDec 8 - Check Frequency Counter module

    

       
            
  
  10771   Tue Dec 9 16:07:16 2014 manasaSummaryGeneralDec 9 - FC module and fiber chassis

    

       
            
 FCmodule.png 
  10775   Wed Dec 10 16:12:29 2014 manasaSummaryGeneralDec 10 - PSL table

    

       
            
 FiberMod_front.jpgFOL_fiber.jpg 
  10780   Thu Dec 11 12:50:12 2014 manasaSummaryGeneralPSL table optical layout I assembled the telescope to couple
PSL light into the fiber. The maximum coupling
that I could obtain was 
  
  10787   Thu Dec 11 23:34:06 2014 manasaSummaryGeneralPSL table optical layout

    

       
            
  
  10788   Fri Dec 12 02:30:25 2014 JenneSummaryGeneralPSL table optical layout

    

       
            
  
  10791   Fri Dec 12 14:38:39 2014 manasaSummaryGeneralFrequency Offset Locking - To Do List (Revised)Unfortunately the order placed for beam
samplers last week did not go through. These
will be used at the X and Y end tables to
 FOLtodolist.pdf 
  10792   Fri Dec 12 15:19:04 2014 manasaSummaryGeneralDec 12 - PSL table

    

       
            
 PSLtoFiber.pngPSLfiberChassis.pngPSLfiberChassis.png 
  10800   Mon Dec 15 22:40:09 2014 ranaSummaryPSLPMC restored Found that the PMC gain has been
set to 5.3 dB instead of 10 dB since 9 AM
this morning, with no elog entry.
 SadToastFace.jpg 
  10808   Wed Dec 17 11:57:56 2014 manasaSummaryGeneralY arm optical layoutI
was working around the PSL table and Y endtable
today.
 58.png 
  10829   Mon Dec 22 15:46:58 2014 KurosawaSummaryIOOSeven transfer functionsIMC OL TF has been measured from 10K to
10M
 MC_OLTF.pdf 
  10849   Tue Dec 30 20:35:59 2014 ranaSummaryPSLPMC Tune Up
    Calibrated the Phase Adjust
slider for the PMC RF Modulation; did this
by putting the LO and RF Mod out on the TDS
 17.pngPMCcal.ipynb.xzPMC_Osc_Cal.pdf 
  10879   Thu Jan 8 19:02:42 2015 JaxSummaryElectronicsMC demod modificationsHere's a summary of the changes made
to the D990511 serial 115 (formerly
known as REFL 33), as well as a short procedure.
 demodprocessI.pngdemodprocessQ.pngIMG_0247.JPGIMG_0239.JPGIMG_0243.JPG 
  10899   Wed Jan 14 02:11:07 2015 ranaSummaryTreasure2-loop Algebra LoopologyI show here
the matrix formalism to calculate analytically
the loop TF relationships for the IMC w/
 FSSloop.pdfFSSloop.png 
  10952   Wed Jan 28 23:53:24 2015 KojiSummaryASCXarm ASS fixX-Arm
ASS was fixed.
ASS_DITHER_ON.snap was updated so
 12.png 
  10974   Wed Feb 4 18:27:55 2015 KojiSummaryASCXarm ASS fixPlease remember
that Xarm ASS needs FM6 (Bounce filters)
  
  10986   Sat Feb 7 13:34:11 2015 KojiSummaryPSLISS AOM driver checkI wanted to check the status of the ISS.
The AOM driver response was measured on Friday
night.
 AOM_drive.pdfAOM_response.pdf 
  10988   Sun Feb 8 21:54:50 2015 ranaSummaryPSLISS AOM driver checkThis is good
news. It means that the driver probably won't
limit the response of the loop - I expect
  
  11005   Wed Feb 11 18:11:46 2015 KojiSummaryLSC3f modulation cancellation33MHz sidebands can be elliminated by careful
choice of the modulation depths and the relative
phase between the modulation signals.
  
  11029   Sat Feb 14 19:54:04 2015 KojiSummaryLSC3f modulation cancellationOptical
Setup

[Attachment 1]
 beat_setup1.JPGbeat_setup2.JPGelectrical_setup.pdf 
  11031   Sat Feb 14 20:37:51 2015 KojiSummaryLSC3f modulation cancellationExperimental
results

- PD response [Attachment
 beat_pd_response.pdfbeat_nominal.pdf3f_reduction.pdfbeat_3f_reduced.pdf 
ELOG V3.1.3-