40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 5 of 341  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  724   Wed Jul 23 16:31:02 2008 AlbertoConfigurationComputersMegatron connectedJoe, Rana, Alberto,

we found out the password for Megatron so
  
  725   Wed Jul 23 17:19:48 2008 AlbertoConfigurationComputersMegatron connectedWe changed the IP address. Ther new one is
131.215.113.95.
  
  798   Tue Aug 5 10:56:05 2008 AlbertoConfigurationGeneralITMX chamber opened and mirror releasedD-Mass, Steve, Rana, Koji, Yoichi, Alberto,
We opened the ITMX chamber to check the optics
after last week earthquake. In particular,
  
  800   Tue Aug 5 17:56:23 2008 AlbertoConfigurationGeneralSRM and PRM inspectionYoichi, Koji, Rana, Steve, Alberto

Today we opened the [B]BSC[/B] to inspect
 IMG_1434.JPGIMG_1456.JPG 
  805   Wed Aug 6 19:01:15 2008 AlbertoUpdateGeneralITMX and SRM OSEM post-earthquake diagnosticKoji, Yoichi, Alberto

Today we reset the OSEMs on ITMX and SRM
  
  916   Wed Sep 3 18:45:01 2008 AlbertoConfiguration PD3 gainAlberto, Yoichi,

We found that the PD3 servo was unstable
  
  940   Wed Sep 10 19:53:53 2008 AlbertoUpdateGeneralabs length experimentUpdate of the last days work on the experiment
to measure the absolute length of the cavities.
  
  944   Fri Sep 12 11:09:20 2008 AlbertoUpdateGeneralabs cavity length experimentI'm leaving the lab for a couple of hours.
I shut the NPRO. The interferometer is available
to anyone.
  
  945   Sat Sep 13 23:13:01 2008 AlbertoUpdateGeneralabs cavity length experimentThe Y arm was locked all time today but, suddenly,
this afternoon it lost lock and since then
I've been unable to restore it. I tried unsuccessfully
  
  946   Sun Sep 14 18:30:32 2008 AlbertoUpdateGeneralABSL: measured X armToday I measured the X arm FSR.
Hi moved the fast PD (Thor Labs PDA255) from
the Y end table to the X end table. I had
  
  947   Sun Sep 14 19:29:07 2008 AlbertoUpdateGeneralABSL: measured X arm[quote]Today I measured the X arm FSR.
Hi moved the fast PD (Thor Labs PDA255) from
the Y end table to the X end table. I had
  
  956   Wed Sep 17 13:58:36 2008 AlbertoUpdateGeneralABSL: results from the X armToday I repeated the measurement of the FSR
on the X arm cavity. The noise in the transmitted
power that made the measures fluctuate was
 Sept17_XarmFSRmeasurement_report.ps 
  960   Wed Sep 17 19:13:47 2008 AlbertoUpdateGeneralABSL: statusI installed the setup for measuring TEM01/10
on the X end table. 
I'm leaving. I shut the laser, flipped down
  
  979   Mon Sep 22 20:00:35 2008 AlbertoUpdateGeneralABSL: running measurementI'm leaving the X arm locked on the TEm01
mode while a measurement is running. Just
please wait for 40 minute if you need the
  
  987   Wed Sep 24 17:57:04 2008 AlbertoUpdateGeneralABSL: FSS Slow Actuator ControlRana, Alberto

Today when I started working with the PLL
  
  1015   Wed Oct 1 12:05:58 2008 AlbertoConfigurationComputers"StochMon" added to the Alarm HandlerJohn, Alberto,

we added the four channels of the RF Amplitude
  
  1016   Wed Oct 1 12:09:25 2008 AlbertoConfigurationComputers"StochMon" added to the Alarm Handler[quote]John, Alberto,

we added the four channels of the RF Amplitude
  
  1022   Fri Oct 3 12:15:21 2008 AlbertoConfigurationIOOC1iool0 rebootedThis morning, in order to update the threshold
values of the alarm handler for the StochMon,
I rebooted the C1iool0 computer following
  
  1028   Mon Oct 6 12:45:41 2008 AlbertoDAQLSCC1LSC in comaAlberto, Joe,

The C1LSC medm screen is frozen and the C1LSC
  
  1029   Mon Oct 6 16:41:33 2008 AlbertoDAQLSCC1LSC in coma[quote]Alberto, Joe,

The C1LSC medm screen is frozen and the C1LSC
  
  1030   Tue Oct 7 10:49:29 2008 AlbertoUpdateGeneralDisplaced PhotodiodeThis morning I found that the photodidode
of the PLL in the PSL table was not aligned
to the beam anymore. The PD support was not
  
  1031   Tue Oct 7 12:17:57 2008 AlbertoConfigurationComputersTime reset on MEDMYoichi, Alberto

I noticed the MEDM screen time was about
  
  1039   Fri Oct 10 10:20:42 2008 AlbertoOmnistructureComputersFEs are down[quote]
The front-end machines are all down.  Another
cosmic-ray in the RFM, I suppose.  Whoever
  
  1040   Fri Oct 10 13:57:33 2008 AlbertoOmnistructureComputersProblems in locking the X armThis morning for some reason that I didn't
clearly understand I could not lock the Xarm.
The Y arm was not a problem and the Restore
  
  1066   Wed Oct 22 09:42:41 2008 AlbertoDAQComputersc1iool0 rebooted and MC autolocker restartedThis morning I found the MC unlocked. The
MC-Down script didn't work because of network
problems in communicating with scipe7, a.k.a.
  
  1070   Wed Oct 22 20:50:30 2008 AlbertoOmnistructureComputersGPSToday I measured the GPS clock frequency at
the output of CLOCK_MON in a board on the
same crate where the c1iool0 computer is
  
  1072   Thu Oct 23 15:27:19 2008 AlbertoUpdateGeneralAbs lengthHere are the measurements I've got yesterday.
The plot shows the transmitted power after
the X arm while sweeping the frequency of
 TRX_aplot_03_04_05_together.png 
  1073   Thu Oct 23 18:23:47 2008 AlbertoUpdateGeneralAbs length[quote]Here are the measurements I've got
yesterday. The plot shows the transmitted
power after the X arm while sweeping the
 TRX_plot_06_07_08_together.png 
  1074   Thu Oct 23 18:27:04 2008 AlbertoUpdateGeneralAbs length[quote]Here are the measurements I've got
yesterday. The plot shows the transmitted
power after the X arm while sweeping the
 HOM_Frequencies.m 
  1075   Thu Oct 23 18:45:18 2008 AlbertoOmnistructureComputer Scripts / ProgramsPython code for GPIB devices developed for the Absl length experimentI wrote two Python scripts for my measurement
that can be also used/imitated by others:
sweepfrequency. py and HP8590.py. The first
 HP8590.pysweepfrequency.py 
  1076   Thu Oct 23 18:51:19 2008 AlbertoMetaphysicsComputerseLogI checked it and the latest version of the
elog software, the 2.7.5 (we have the 2.6.5)
has, among new nice features, the very good
  
  1084   Fri Oct 24 11:42:48 2008 AlbertoUpdateGeneralAbs length: locking the X arm cavity in TEM01/10I went back to lock the arm cavity in either
TEM01 or TEM10 mode. Attached are the results.
We still have several resonances which we
 TRX_armTEM00-plot_09-10_together.png 
  1086   Fri Oct 24 17:21:13 2008 AlbertoUpdateGeneralAbs length: the right amount of beam clippingI found the reason why the peak at about 6.3MHz
appeared only on the TEM10 mode: the blade
was clipping the beam too much and it was
 24OCT08_levels_of_clipping_comparison.png 
  1087   Fri Oct 24 18:05:01 2008 AlbertoUpdateGeneralAbs length: transverse mode spacing measured for the X armThe ETMX suffers of astigmatism. I measured
the following frequencies for the higher
order modes:
 24OCT08_TEM10-01_comparison(file12-14).png 
  1093   Mon Oct 27 11:16:23 2008 AlbertoConfigurationIOOStochMon CalibrationI implemented the calibration for the four
channels of the StochMon in the ioo EPICS
database. Now the output of those channels,
  
  1097   Tue Oct 28 11:10:18 2008 AlbertoUpdateLSCHigher Order Mode resonances in the X arms[quote]Recently we had been having some trouble
locking the full IFO in the [COLOR=green][I][FONT=Verdana]spring[/FONT][/I][/COLOR]
configuration (SRC on [COLOR=blue]+166[/COLOR]).
 HOM_resonances_Xarm.png 
  1109   Mon Nov 3 19:18:47 2008 AlbertoConfigurationGeneralnew elogPhil Ehrens kindly poured our elog's content
in a CD that now is here at the 40m.
I've been trying to install the 2.7.5 version
  
  1114   Tue Nov 4 17:58:42 2008 AlbertoDAQPSLMC temperature sensorI added a channel for the temperature sensor
on the MC1/MC3 chamber: C1:PSL-MC_TEMP_SEN.
To do that I had to reboot the frame builder.
  
  1115   Wed Nov 5 12:41:36 2008 AlbertoUpdateLSCAbsolute Length and g-factor measurements conclusions[SIZE=4][B][COLOR=green]Absolute Length and
g-Factor Measurement for the 40m Arm Cavities,
Summary of Results[/COLOR][/B][/SIZE]
 2008-11-04_file_02-05.pngHOM_resonances_Xarm.pngHOM_resonances_Yarm.png 
  1124   Fri Nov 7 18:38:19 2008 AlbertoDAQPSLMC temperature sensor hooked upAlberto, Rana,
we found that the computer handling the signals
from ICS-110B was C1IOVME so we restarted
  
  1132   Thu Nov 13 11:33:25 2008 AlbertoHowToTreasureMaking (good) Matlab figuresJust a little summary of some useful ways
to change plot settings in Matlab that I
wanted to share and remember for the future:
  
  1133   Thu Nov 13 15:50:44 2008 AlbertoConfigurationGeneralGPS 10MHz clockThe schematic of the 1Y7 rack that Alan pointed
out (see attachment) don't represent anymore
the actual rack.
 rackstuff.pdf 
  1139   Mon Nov 17 11:01:15 2008 AlbertoHowToElectronicsCalibrating the Frequency Standard of the MarconiI locked the [COLOR=purple][I]SRS Rubidium
Frequency Standard FS275[/I][/COLOR] to the
the 1pps from the GPS. The specs from the
 2023ASeriesOperatingManual.pdfSRS_FS275_Rubidium_Frequency_Standard.pdf 
  1145   Tue Nov 18 19:44:53 2008 AlbertoUpdateGeneralX Arm Cavity "Negative" FSRs MeasuredPrevious measurements on the X arm cavity
revealed a shift of the frequencies of the
cavity resonances from where one would expect
 2008-11-17_Linear_Fit.pdf 
  1146   Wed Nov 19 10:32:11 2008 AlbertoConfigurationElectronicsAll the Marconi Set to the Rubidium Frequency StandardI placed the SRS Rubidium FS275 over the PSL
rack, next to the frequency counter. This
one and the Marconi on the PSL rack have
  
  1169   Wed Dec 3 11:58:10 2008 AlbertoUpdatePSLMC AlignmentRana, Alberto,

more details on the MC alignment we did yesterday.
  
  1192   Thu Dec 18 12:52:00 2008 AlbertoConfigurationSUSMode Cleaner Cavity AlignmentThis morning I found the MC locked to the
10 mode. When I locked it on the 00 mode,
it was unstable and eventually it always
  
  1194   Fri Dec 19 11:18:52 2008 AlbertoConfigurationGeneralMode Cleaner Temperature MonitorI reduced from 10 to 5 the gain of the SR560
that Caryn has set up after the lock-in amplifier
nest to the PSL rack because the overload
  
  1244   Thu Jan 22 11:54:09 2009 AlbertoConfigurationPSLMach Zehnder Output Beam QPDI rotated by 180 degrees the 10% beam splitter
that it is used to fold the beam coming from
the Mach Zehnder (directed to the MC) on
  
  1252   Sat Jan 24 11:50:24 2009 AlbertoConfigurationElectronicsPhotodiode Filters' Transfer FunctionsI found an elog entry by Jenne with the measurement
of the transfer functions of the filters
of some of our photodetectors. Since it might
  
ELOG V3.1.3-