  5456   Mon Sep 19 11:49:32 2011 JenneHowToGeneralPlan for this week: SUS inversion


   
        
            
  
  5461   Mon Sep 19 15:41:48 2011 JenneUpdateSUSSUS diag stuff... just so I remember what I'm doingThe following optics were kicked:
ETMX
Mon Sep 19 15:39:44 PDT 2011
  
  5471   Mon Sep 19 22:47:44 2011 JenneUpdateSUSSUS diag stuff... just so I remember what I'm doing The last person out tonight should
run the following scripts:
In Matlab: 
  
  5476   Tue Sep 20 04:12:26 2011 JenneUpdateSUSJenne's Scripts started

    

       
            
  
  5477   Tue Sep 20 09:44:44 2011 JenneUpdateSUSJenne's Scripts started

    

       
            
  
  5479   Tue Sep 20 14:53:13 2011 JenneUpdateSUSJenne's Scripts started


   
        
            
  
  5480   Tue Sep 20 15:23:16 2011 JenneUpdateSUSfree swinging test in vacuum conditionThis is using data for the SRM from:  20
Sept 2011 03:20:00 PDT = 1000549215
You can see that there are still
 SRM.png 
  5485   Tue Sep 20 16:45:09 2011 JenneUpdateSUSSUS diag stuff... just so I remember what I'm doingHas the Q been checked?  Still
in progress...
  
  5548   Mon Sep 26 17:49:21 2011 JenneUpdateComputersWe now have BURT restore for slow channelsKoji and Suresh found that there have not been any autoburt snapshots   
  5550   Mon Sep 26 18:59:11 2011 JenneUpdateAdaptive FilteringPlan for making MC_F


   
        
            
  
  5552   Mon Sep 26 22:40:41 2011 JenneUpdateComputersWe now have BURT restore for slow channels[Jenne, Koji]

After much Perl-learning and a few iterations,
  
  5556   Tue Sep 27 11:43:59 2011 JenneUpdateelogElog has been dying a lot lately...WTF?   
  5557   Tue Sep 27 11:52:33 2011 JenneUpdateAdaptive FilteringPlan for making MC_F

    
        
  
  5558   Tue Sep 27 15:33:03 2011 JenneUpdateComputersMaking models, wreaking havoc[Jenne, Mirko, Den]
We have entered into an adventure
in model compiling.  What follows is
  
  5560   Wed Sep 28 00:06:21 2011 JenneUpdateSUSWatchdog rearmed

    

       
            
  
  5564   Wed Sep 28 13:30:01 2011 JenneUpdatePSLPMC was unlockedRelocked the PMC.  MC came back immediately.   
  5565   Wed Sep 28 14:15:40 2011 JenneUpdateComputersEdits to c1pem, c1oaf[Mirko, Jenne]
Mirko edited c1pem to have some new
BLRMS channels.
  
  5571   Wed Sep 28 22:25:25 2011 JenneUpdateComputersTorturing control computers. Fine again now


   
        
            
  
  5572   Wed Sep 28 22:30:01 2011 JenneUpdateAdaptive FilteringOAF is disabledI am leaving the
OAF disabled, so there should be nothing
  
  5575   Thu Sep 29 11:25:55 2011 JenneUpdateAdaptive FilteringTried new c-code, Fail.[Mirko, Jenne]
Mirko edited the c-code to use Den's
stuff that he put in the elog last night. 
  
  5576   Thu Sep 29 12:56:27 2011 JenneUpdateAdaptive FilteringMeditations on the OAF[Mirko, Den, Jenne]
We're modifying the c1oaf model,
and we got to talking about the "Fx"
  
  5600   Mon Oct 3 13:04:12 2011 JenneUpdateSUSAUXEX, AUXEY rebooted


   
        
            
  
  5601   Mon Oct 3 14:05:41 2011 JenneUpdateSUSFailing to set SUS summary screen valuesI assume it's because the burt restore
didn't work for the SUS summary screen, but
all of the values for the ifo suspensions
  
  5602   Mon Oct 3 16:18:05 2011 JenneUpdateAdaptive FilteringMeditations on the OAF


   
        
            
  
  5603   Mon Oct 3 17:06:27 2011 JenneHowToComputer Scripts / ProgramsKissel Button Generator


   
        
            
  
  5604   Mon Oct 3 17:27:23 2011 JenneUpdateSUSFailing to set SUS summary screen values

    

       
            
  
  5608   Mon Oct 3 21:20:30 2011 JenneUpdateCDSc1lsc and c1sus didn't run[Jenne, Mirko, Kiwamu, Koji, and Jamie
by phone]
We just got off the phone with Jamie. 
  
  5612   Tue Oct 4 14:41:47 2011 JenneUpdateIOOMC Trans channels are digital 0I relocked the PMC (why is it unlocking
so much lately??), and then noticed that
even though the MC is locked, MC Trans Sum,
  
  5625   Thu Oct 6 15:37:26 2011 JenneUpdateGreen LockingY-green Mech Shutter Button[Katrin, Jenne]
We were poking around and tried to
make a button for the Y-green shutter, just
  
  5626   Thu Oct 6 15:40:57 2011 JenneUpdateLSCArm absl length data taken[Katrin, Jenne]
We took the data for the new absolute
length measurement of both arms, after the
  
  5653   Tue Oct 11 21:23:51 2011 JenneUpdateLSCArm absl lengths

    

       
            
  
  5705   Wed Oct 19 18:16:53 2011 JenneUpdatePSLPMC found unlockedI just relocked the PMC.  I don't
know why it was unlocked.
  
  5707   Wed Oct 19 19:43:16 2011 JenneUpdatePSLPMC found unlocked

    
        
  
  5714   Thu Oct 20 18:01:17 2011 JenneUpdateComputer Scripts / ProgramsWhere should the "Update Snapshots" of screens live?While trying to implement the regular yellow
shell script button in MEDM for my new OAF
screen, I noticed that the update snapshot
  
  5756   Fri Oct 28 14:56:02 2011 JenneUpdateCDSCSS/BOY installed on pianosa


   
        
            
  
  5757   Fri Oct 28 15:33:06 2011 JenneUpdateComputersNifty screen generatorSuresh showed me a cool script that Mirko
made, but didn't elog
  
  5772   Mon Oct 31 19:39:00 2011 JenneUpdateAdaptive FilteringScreens, code, computers[Mirko, Jenne]
I finished (mostly? maybe?) the OAF
screens.  They're pretty awesome. 
  
  5778   Tue Nov 1 18:45:48 2011 JenneUpdateComputersAllegra's screensI was trying to give Allegra a second head,
and it didn't quite work.  It's still
in progress.  Steve, you might not like
  
  5792   Wed Nov 2 22:02:39 2011 JenneUpdatePhotosNew screen snapshot script written!After lots of trial and error, and a little
inspiration from Koji, I have written a new
script that will run when you select "update
  
  5793   Thu Nov 3 13:00:52 2011 JenneUpdatePhotosFormatting of MEDM screen names

    

       
            
  
  5812   Fri Nov 4 15:26:54 2011 JenneUpdateLSCLSC model recompiledI moved the place where we take the OAF
Degree of Freedom signals from - now it's
the error point rather than the feedback
  
  5828   Mon Nov 7 11:50:42 2011 JenneUpdateelogRestarted elogElog restart script killed the elog, but
didn't restart it.  Restarted by hand.
  
  5830   Mon Nov 7 14:50:19 2011 JenneUpdateComputersISCEX is having a bad dayI clicked on the FE status screen, just
to check on things, and everything on the
c1iscex section was 
  
  5832   Mon Nov 7 15:15:21 2011 JenneUpdateLSCLSC model recompiled

    
        
  
  5835   Mon Nov 7 16:42:56 2011 JenneUpdateAdaptive FilteringBLRMS's to monitor OAF channelsI copied Mirko's PEM BLRMS block, and made
it a library part.  I don't know where
such things should live, so I just left it
  
  5848   Wed Nov 9 14:23:35 2011 JenneUpdateAdaptive FilteringOAF MC Delay MeasurementAs described in elog
2063 and the mevans
document, we need to measure the TF of
 OAF-MCL-Delay-9Nov2011.pdf 
  5853   Wed Nov 9 17:41:17 2011 JenneUpdateComputersETMX restoredJamie did computer magic.  I burt
restored scxepics, and restored ETMX damping.
  
  5861   Thu Nov 10 11:52:00 2011 JenneUpdateCDSRFM signal transferringI am not so happy with the control signals
that are coming into the OAF via the RFM/Dolphin/shmem. 
The MCL/MCF signal travels via RFM
 OAF_rfm_signals_MCL.pdfOAF_rfm_signals_MICH.pdfOAF_rfm_signals_PRCL.pdfOAF_rfm_signals_GUR1X.pdf 
  5862   Thu Nov 10 12:28:31 2011 JenneUpdateSUSMC2 is being a little wild...WFS to blameMirko and  Den are measuring MC_F,
which they will report about later, but I
noticed that MC2 is totally crazy right now. 
 WFSscreenshot.png 
  5865   Thu Nov 10 19:41:24 2011 JenneUpdateSUSMusings on SUS dewhitening, and MC ELP28'sThe
following will be a stream-of-consciousness,
approximately chronological story of my last
  