ID Date Author Type Category Subjectup Text Attachments
  11675   Thu Oct 8 21:35:49 2015 ranaUpdateLSCDRFPMI ProgressGive us a lockloss or other kind of time
series plot so we can bask in the glory.
  
  11676   Fri Oct 9 09:22:38 2015 ericqUpdateLSCDRFPMI Progress   oct8_allRF.pdf 
  11677   Fri Oct 9 11:24:06 2015 JenneUpdateLSCDRFPMI ProgressI hope the grappa was already cold, and
ready to drink! 
  
  11725   Mon Nov 2 17:39:01 2015 KojiFrogsGeneralDRFPMI celebrationやったー!Yatta!  yatta.jpg 
  8179   Wed Feb 27 02:44:39 2013 JenneUpdateLockingDRFPMI flashesBefore Yuta left, I asked him to restore
all optics to last saved values, to avoid
hysteresis.
  
  8191   Wed Feb 27 20:10:43 2013 ranaUpdateLockingDRFPMI flashes 
 If its true that there have
been large flashes, then there indeed might
  
  675   Tue Jul 15 12:44:08 2008 JohnSummaryLockingDRFPMI with DC readoutRob, John

Last night, despite suspect alignment, we
  
  11718   Tue Oct 27 03:56:52 2015 ericqUpdateLSCDRFPMI workA handful of DRFPMI locks tonight, longest
one was ~7 minutes. 

EPICS/network latency has been
  
  11722   Thu Oct 29 03:25:49 2015 ericqUpdateLSCDRFPMI work[ericq, Gautam]

The length of DRFPMI lock did not
increase much tonight, but we got a ~80 second sensing
 DRFPMI.pdfDRMIarms.pdf 
  11726   Tue Nov 3 03:12:46 2015 ericqUpdateLSCDRFPMI workTonight was kind of a wash. 

We spent some time retaking
single arm scans with Gautam's frequency
  
  10700   Wed Nov 12 01:30:39 2014 ericqUpdateLSCDRFPMI, PRFPMI HOM resonancesI did some simulations to see if we are
susceptible to HOM resonances as we reduce
the CARM offset. I restricted my search to
 HOMs.zipDRFPMI_HOMscan.pngPRFPMI_HOMscan.png 
  10705   Wed Nov 12 21:18:32 2014 ericqUpdateLSCDRFPMI, PRFPMI HOM resonancesSo, with my last entry, I was guilty of
just throwing stuff into the simulation and
not thinking about physics... so I retreated
 HOMlist.py.zip 
  1670   Fri Jun 12 02:01:03 2009 robUpdateComputer Scripts / ProgramsDRM matrix diagonalizationI started two scripts, senseDRM
and loadDRMImatrixData.m, which Peter
will bang on until they're correct. 
  
  11637   Wed Sep 23 03:08:50 2015 ericqUpdateLSCDRMI + ALS Arms[ericq, Gautam]

We can reliably
 DRMIarms.pdf 
  11638   Wed Sep 23 10:31:49 2015 ericqUpdateLSCDRMI + ALS ArmsLooking good. How many meters of CARM is
'-1 counts'?
  
  11639   Wed Sep 23 12:51:03 2015 JenneUpdateLSCDRMI + ALS ArmsNice!!    
  9049   Thu Aug 22 02:40:12 2013 JenneUpdateLSCDRMI Locked for 1+ minute!!!!!![Jenne, Koji]
The DRMI
 DRMI_First_Lock_1plusMinute_21Aug2013.png 
  9050   Thu Aug 22 07:57:57 2013 LisaUpdateLSCDRMI Locked for 1+ minute!!!!!!  Very nice!!  I was wondering, shouldn't
the driving matrix be such that MICH pushes
  
  9051   Thu Aug 22 10:20:32 2013 kiwamuUpdateLSCDRMI Locked for 1+ minute!!!!!!Wonderful
! I like the video -- the spatial
  
  9052   Thu Aug 22 13:03:40 2013 JenneUpdateLSCDRMI Locked for 1+ minute!!!!!!

    

       
            
  
  9053   Thu Aug 22 13:20:54 2013 KojiUpdateLSCDRMI Locked for 1+ minute!!!!!!Don't go for a hacky solution. We want
to climb a staircase step by step.
Prepare an independent 110MHz demod
  
  9060   Sat Aug 24 00:11:07 2013 KojiUpdateLSCDRMI Locked with improved lock streatchesFriday night  Screenshot-Untitled_Window.png 
  9061   Sun Aug 25 06:07:11 2013 ranaUpdateLSCDRMI Locked with improved lock streatches We're ready
for using the auto configure.
We
can put our scripts for the MICH, PRMI, and
  
  13367   Mon Oct 9 01:29:26 2017 gautamUpdateLSCDRMI Nosie Budget v3.0Summary:

I
spent this weekend doing a more careful investigation
of the DRMI noise.
 7x 
  13368   Mon Oct 9 11:55:01 2017 KojiUpdateLSCDRMI Nosie Budget v3.0My last characterization of the AS55 PD
was on Feb 2013. ELOG
8100
  
  13412   Tue Nov 7 17:45:05 2017 gautamUpdateLSCDRMI Nosie Budget v3.1Some days ago, I had tried to measure the
SRCL->MICH and PRCL->MICH cross couplings
using broadband noise injected between 120-180
 SRCL_MICH_whitenoise_tf.pdfPRCL_MICH_whitenoise_tf.pdfMICH_aux.pdfC1NB_disp_40m_MICH_NB_2017-10-08.pdf 
  13415   Wed Nov 8 09:37:45 2017 ranaUpdateLSCDRMI Nosie Budget v3.1why no oplev trace in the NB ?




  
  13416   Wed Nov 8 09:59:12 2017 gautamUpdateLSCDRMI Nosie Budget v3.1The Oplev trace is missing for now, as
I have not re-measured the A2L coupling since
modifying the Oplev loop shape (specifically
  
  1285   Mon Feb 9 16:05:01 2009 YoichiUpdateLSCDRMI OKAfter the ISS work, I aligned the IFO and
confirmed that DRMI locks with good SPOB
and AS166 values.
  
  7383   Fri Sep 14 00:56:13 2012 JenneUpdateGeneralDRMI aligned[Rana, Jenne]
We
aligned the DRMI, and have concluded that
  
  7405   Wed Sep 19 01:08:48 2012 JenneUpdateGeneralDRMI aligned againThe DRMI was aligned once again tonight. 
Here's a video: http://youtu.be/Cy8nHL9yMeM 
(Can someone please tell me / remind me how
 DRMI_aligned_19Sept2012_ETMYwasHighNeedToFix.png 
  7415   Thu Sep 20 01:28:14 2012 JenneUpdateGeneralDRMI aligned again, but with good arms[Jenne, Manasa]
Using the alignment of the PZTs and
BS from pre-dinner, where the beam was hitting
  
  7417   Thu Sep 20 08:34:46 2012 ManasaUpdateGeneralDRMI aligned again, but with good arms

    

       
            
  
  7419   Thu Sep 20 11:39:40 2012 ManasaUpdateGeneralDRMI aligned again, but with good arms 
 QPD at IPPOS has been centered
by removing the filter at the QPD.
  
  6508   Sat Apr 7 06:58:34 2012 kiwamuUpdateLSCDRMI lock : lost good alignmentSomehow I lost the good alignment, where
the lock can be frequently acquired and hence
I didn't go further ahead.
  
  862   Wed Aug 20 13:23:32 2008 robUpdateLockingDRMI locked
I was able to lock the DRMI this afternoon.
 All the optical levers have been centered.
  
  10661   Sat Nov 1 16:06:32 2014 KojiConfigurationLSCDRMI lockedContinued from ELOG
10659 

 6x 
  5627   Fri Oct 7 04:42:24 2011 kiwamuUpdateLSCDRMI locked and some plansDRMI has been
locked using the same RFPD selection as the
  
  5629   Fri Oct 7 11:53:47 2011 KojiUpdateLSCDRMI locked and some plans- REFL165 PD to be fixed (shows constant
high voltage at the DC out)
- Make POP22/110 PD
  
  11571   Fri Sep 4 04:05:51 2015 ericqUpdateLSCDRMI locked on 1F and 3FThanks to some expertly timed coffee from
Ignacio, I have been able to achieve indefnite
locks of the DRMI, first on a 1F/3F
  
  11578   Fri Sep 4 20:06:23 2015 ranaUpdateLSCDRMI locked on 1F and 3FNice going. I think the LLO / LHO scheme
is to acquire on 1F and then cdsutils avg
to get the 3F offsets. The thinking is that
  
  12619   Wed Nov 16 03:10:01 2016 gautamUpdateLSCDRMI locked on 1f and 3f signalsAfter much trial and error with whitening
gains, demod phases and overall loop gains,
I was finally able to lock the DRMI
  
  12620   Wed Nov 16 08:14:43 2016 SteveUpdateLSCDRMI locked on 1f and 3f signalsNice job.




 5hrs.png 
  12630   Mon Nov 21 14:02:32 2016 gautamUpdateLSCDRMI locked on 3f signals, arms held on ALSOver the weekend, I was successful in locking
the DRMI with the arms held on ALS. The locks
were fairly robust, lasting order of minutes,
 DRMIArms_Nov20.pdf 
  6489   Thu Apr 5 07:19:16 2012 kiwamuUpdateLSCDRMI locking I
tried locking the DRMI to the signal-extraction
condition with the new trigger by AS110.
 DRMI_2012Apr4_edit.png 
  10498   Fri Sep 12 00:40:23 2014 JenneUpdateLSCDRMI locking Tonight I worked on DRMI locking.
 
I think the reason the May2014 DRMI
  
  10500   Fri Sep 12 11:25:42 2014 KojiUpdateLSCDRMI lockingThis is great.
And I got confused. Is REFL11 going
through the CM board? 
  
  10501   Fri Sep 12 12:00:59 2014 ericqUpdateLSCDRMI lockingREFL11 I, as seen in digital land, is connected
to the slow output of the CM board. I tuned
the demod angle of the REFL11 demodulator
  
  10502   Fri Sep 12 14:11:17 2014 ericqUpdateLSCDRMI lockingWe
need to get an interferometric estimation
of the SRC length error / SRC sideband splitting,
 7x 
  10514   Wed Sep 17 15:40:00 2014 ericqUpdateLSCDRMI lockingI have not had any success the past two
days in getting an interferometric measurement
of the SRC length. 
 dcAngleDiff_srcL.pdfdrfpmiVertexSensing.zip 