  13379   Thu Oct 12 14:42:45 2017 gautamUpdateCDSslow machine bootfestSteve reported problems getting the X arm
locked. Alignment sliders were inaccessible.
Eurocrate key turning reboots for 
  
  13381   Mon Oct 16 12:13:38 2017 gautamUpdateCDSMegatron maintenanceWall StripTool traces showed that IMC has
not been locked for at least 8 hours when
I came in this morning. Going to the IMC
  
  13385   Tue Oct 17 23:07:52 2017 gautamUpdateCDSFEs unresponsiveWhile working on the IFO tonight, I noticed
that the blinky status lights on c1iscex
and c1iscey were frozen (but those on the
  
  13386   Wed Oct 18 01:41:32 2017 jamieUpdateCDSFEs unresponsive


  
  13387   Wed Oct 18 02:09:32 2017 gautamUpdateCDSFEs unresponsiveI was looking at the ASDC channel on dataviewer,
and toggling various settings like whitening
gain. At some point, the signal just froze.
  
  13388   Wed Oct 18 09:21:22 2017 jamieUpdateCDSFEs unresponsive


  
  13394   Wed Oct 18 23:11:53 2017 gautamUpdateCDSFEs unresponsiveThis happened again just now - it was roughly
this time when this happened last night as
well.
  
  13396   Fri Oct 20 16:30:17 2017 gautamUpdateCDSFB1 installed on shelves[steve, jamie, gautam]

The machine that now serves as
out Frame Builder, FB1, was sitting on top
  
  13398   Tue Oct 24 16:22:53 2017 gautamUpdateCDSToy DARM model setup in c1tst[alex, gautam]

Alex is going to have an undergrad
work on a calibration optimization project
 TOY_DARM.pngTOY_DARM_SIMULINK.png 
  13399   Tue Oct 24 16:43:11 2017 SteveUpdateCDSslow machine bootfest[ Gautam , Steve ]

c1susaux
  
  13404   Sat Oct 28 00:36:26 2017 gautamUpdateCDS40m files backup situation - ddrescueNone of the 3 dd backups I made were bootable
- at boot, selecting the drive put me into
grub rescue mode, which seemed to suggest
 415E2F09-3962-432C-B901-DBCB5CE1F6B6.jpegBFF8F8B5-1836-4188-BDF1-DDC0F5B45B41.jpeg 
  13408   Mon Oct 30 11:15:02 2017 gautamUpdateCDSslow machine bootfest + vacuum snafuEurocrate key turning reboots today morning
for c1psl
  
  13410   Mon Nov 6 11:15:43 2017 gautamUpdateCDSslow machine bootfest + IFO re-alignmentEurocrate key turning reboots today morning
for
  
  13420   Wed Nov 8 17:04:21 2017 gautamUpdateCDSgds-2.17.15 [not] installedI wanted to use the foton.py utility for
my NB tool, and I remember Chris telling
me that it was shipping as standard with
  
  13422   Thu Nov 9 15:33:08 2017 johannesUpdateCDSrevisiting Acromag


  
  13436   Tue Nov 21 11:21:26 2017 gautamUpdateCDSRFM network downI noticed yesterday evening that I wasn't
able to engage the single arm locking servos
- turned out that they weren't getting
 RFMerrors.png 
  13477   Thu Dec 14 19:41:00 2017 gautamUpdateCDSCDS recovery, NFS woes[Koji, Jamie(remote), gautam]

Summary:
The CDS system seems to be back up and functioning.
 CDS_14Dec2017.pngCDS_errors.png 
  13479   Fri Dec 15 00:26:40 2017 johannesUpdateCDSRe: CDS recovery, NFS woes


Quote:


  
  13480   Fri Dec 15 01:53:37 2017 jamieUpdateCDSCDS recovery, NFS woes


Quote:


  
  13481   Fri Dec 15 11:19:11 2017 gautamUpdateCDSCDS recovery, NFS woesLooking at the dmesg on c1iscex for example,
at least part of the problem seems to be
associated with FB1 (192.168.113.201, see
 NFS.pngMCautolocker.png 
  13518   Tue Jan 9 11:52:29 2018 gautamUpdateCDSslow machine bootfestEurocrate key turning reboots today morning
for and
  
  13522   Wed Jan 10 12:24:52 2018 gautamUpdateCDSslow machine bootfestMC autolocker got stuck (judging by wall
StripTool traces, it has been this way for
~7 hours) because 
  
  13536   Thu Jan 11 21:09:33 2018 gautamUpdateCDSrevisiting Acromag We'd like to setup the recording of
the PSL diagnostic connector Acromag channels
in a more robust way - the objective is to
  
  13558   Fri Jan 19 11:13:21 2018 gautamUpdateCDSslow machine bootfestc1psl, c1susaux,
and
  
  13620   Thu Feb 8 00:01:08 2018 gautamUpdateCDSVertex FEs all crashedI was poking around at the LSC rack to
try and set up a temporary arrangement whereby
I take the signals from the DAC differentially
 CDSrecovery_20180207.png 
  13643   Tue Feb 20 21:14:59 2018 gautamUpdateCDSRFM network errorsI wanted to lock the single arm POX/POY
config to do some tests on the BeatMouth.
But I was unable to.
  
  13646   Wed Feb 21 12:17:04 2018 gautamUpdateCDSLO Power mon channels added to c1lscTo make this setup more permanent, I modified
the c1lsc
  
  13727   Wed Apr 4 16:23:39 2018 gautamUpdateCDSslow machine bootfest[johannes, gautam]

It's been a while - but today,
all slow machines (with the exception of
  
  13729   Thu Apr 5 10:38:38 2018 gautamUpdateCDSCDS puzzleI'm probably doing something stupid
- but I've not been able to figure this
out. In the MC1 and MC3 coil driver filter
 MC1_outputs.pngEllipTFCheck_MC1.pdfMC1_ELP.tgzEllipTFCheck_MC1.pdf 
  13732   Thu Apr 5 19:31:17 2018 gautamUpdateCDSEPICS processes for c1ioo deadI found all the EPICS channels for the
model c1ioo
  
  13733   Fri Apr 6 10:00:29 2018 gautamUpdateCDSCDS puzzle


Quote:


  
  13734   Fri Apr 6 16:07:18 2018 gautamUpdateCDSFrequent EPICS dropoutsKira informed me that she was having trouble
accessing past data for her PID tuning tests.
Looking at the last day of data, 
 EPICS_dropout.png 
  13758   Wed Apr 18 10:44:45 2018 gautamUpdateCDSslow machine bootfestAll slow machines (except c1auxex)
were dead today, so I had to key them all.
 MCautolocker_MEDM_revamp.png 
  13812   Thu May 3 12:19:13 2018 gautamUpdateCDSslow machine bootfestReboot for c1susaux
and 
  
  13898   Wed May 30 16:12:30 2018 Jonathan HanksSummaryCDSLooking at c1oaf issuesWhen c1oaf starts up there are 446 gain
channels that should be set to 0.0 but which
end up at 1.0.  An example channel is
  
  13925   Thu Jun 7 12:20:53 2018 gautamUpdateCDSslow machine bootfestFSS slow wasn't running so PSL PZT
voltage was swinging around a lot. Reason
was that was 
 ITMX_stuck.png 
  13934   Fri Jun 8 14:40:55 2018 c1lscUpdateCDSi am dead   31.png 
  13935   Fri Jun 8 20:15:08 2018 gautamUpdateCDSReboot scriptUnfortunately, this has happened (and seems
like it will happen) enough times that I
set up a script for rebooting the machine
 31.png 
  13942   Mon Jun 11 18:49:06 2018 gautamUpdateCDSc1lsc dead againWhy is this happening so frequently now?
Last few lines of error log:

 36.png 
  13947   Mon Jun 11 23:22:53 2018 gautamUpdateCDSEX wiring confusion [Koji,
gautam]

Per
  
  13958   Wed Jun 13 23:23:44 2018 johannesUpdateCDSEX wiring confusionIt's true.

I went through the wiring of the
c1auxex crate today to disentangle the pin
 c1auxex_channels.pdfXEND_slow_wiring.pdf 
  13961   Thu Jun 14 10:41:00 2018 gautamUpdateCDSEX wiring confusionDo we really have 2 free ADC channels at
EX now? I was under the impression we had
ZERO free, which is why we wanted to put
  
  13965   Thu Jun 14 15:31:18 2018 johannesUpdateCDSEX wiring confusionBad wording, sorry. Should have been channels
in excess of ETMX controls. I'll add
the others to the list as well.
 XEND_slow_wiring.pdfc1auxex_channels.pdf 
  14000   Thu Jun 21 22:13:12 2018 gautamUpdateCDSpianosa upgradepianosa   
  14003   Fri Jun 22 00:59:43 2018 gautamUpdateCDSpianosa functional, but NO DTTMEDM, EPICS and dataviewer seem to work,
but diaggui still doesn't work (it doesn't
work on Rossa either, same problem as reported
  
  14007   Fri Jun 22 15:13:47 2018 gautamUpdateCDSDTT workingSeems like DTT also works now. The trick
seems to be to run 
 Screenshot_from_2018-06-22_15-12-37.png 
  14008   Fri Jun 22 15:22:39 2018 sudoUpdateCDSDTT working


Quote:


  
  14027   Wed Jun 27 21:18:00 2018 gautamUpdateCDSLab maintenance scripts from NODUS---->MEGATRONI moved the N2 check script and the disk
usage checking script from the (sudo) crontab
of 
  
  14028   Thu Jun 28 08:09:51 2018 SteveUpdateCDS vacuum pneumatic N2 pressureThe fardest I can go back on channel C1:
Vac_N2pres is  320 days

C1:Vac-CC1_Hornet Presuure gauge
 320d_N2.png 
  14029   Thu Jun 28 10:28:27 2018 ranaUpdateCDS vacuum pneumatic N2 pressurewe disabled logging the N2 Pressure to
a text file, since it was filling up disk
space. Now it just sends an email to our
  
ELOG V3.1.3-