Entry  Mon Oct 18 11:22:13 2010, Jenne, Update, Computers, Shame on people not elogging! FrameFiles backups not working. 
On the one hand, SHAME ON ALL PEOPLE WHO DON'T ELOG THINGS,
such as the moving of scripts directories (it was a pain to figure out that that's part of why the backup scripts are broken).  On the other hand,
the moving of the scripts directories brought to light a critical problem in the backup scheme. None of the
Entry  Mon Oct 18 15:33:00 2010, josephb, alex, Update, CDS, Possibly broken timing cards 
It looks as though we may have two IO chassis with bad timing cards.
Symptoms are as follows:
We can get our front end models writing data and timestamps out on the RFM network.
Entry  Mon Oct 18 17:16:30 2010, Jenne, Update, SUS, Old PRM, SRM stored, new PRM drag wiped 
[Jenne, Suresh]
We've put the old PRM and SRM (which were living in a foil house on the cleanroom optical table) into Steve's nifty storage containers.  Also,
we removed the SRM which was suspended, and stored it in a nifty container.  All 3 of these optics are currently sitting on one of the cleanroom optical
    Reply  Mon Oct 18 18:00:36 2010, Koji, Update, SUS, Old PRM, SRM stored, new PRM drag wiped 
- Steve is working on the storage shelf for those optics.
- PRMU002 was chosen as it has the best RoC among the three.


    
        
            
Entry  Mon Oct 18 18:33:46 2010, Koji, Summary, COC, Summary of the main mirrors & their phasemap measurement 
I have made a summary web page for the 40m upgrade optics.
https://nodus.ligo.caltech.edu:30889/40m_phasemap/
I made a bunch of RoC calculations along with the phase maps we measured. 
Entry  Mon Oct 18 22:11:32 2010, Joonho Lee, Summary, Electronics, CCD cables for input signal 
Today I checked all the CCD cables which is connected input channels of the VIDEOMUX.
Among total 25 cables for output, 12 cables are type of RG59, 4 cables are type of RG58, and 9 cables are
of unknown type.
Entry  Tue Oct 19 00:24:07 2010, Dmass, Omnistructure, Electronics, Massive restocking of the 40m 
I had a number of delinquent items on the sign out list from the 40m. I returned about half, and ordered replacements for most of the other half.
I put the photodiodes on the SP table, and the 560 on the electronics  bench.
Entry  Tue Oct 19 15:14:51 2010, Jenne, Update, SUS, PRM (little) update 
[Jenne, Suresh]
We've aligned the guiderod and wire standoff to the PRM, each partly.  They have both been aligned to the correct distance above the scribe
lines, but they have not yet been centered forward/backward along the thickness of the optic.  So, we're working on it...
Entry  Tue Oct 19 22:37:28 2010, Koji, Update, PSL, PSL table cleaning up 
I cleaned up the scattered tools, optics, and mounts of the PSL table. I gathered those stuffs at the two coners.
At the end of the work I scanned the table with an IR viewer. (This is mandatory)
I put some beam block plates to kill weak stray beams.
Entry  Tue Oct 19 21:10:27 2010, yuta, Update, CDS, bad filter coefficients for every suspensions! 
(Koji, Yuta)

Summary:
    Reply  Wed Oct 20 01:22:18 2010, yuta, Update, CDS, fixed filters for MCs, but no damping Screenshot.png
(Rana, Yuta)

Summary:
Entry  Wed Oct 20 16:41:41 2010, steve, Omnistructure, General, laser chiller leaving for MIT P1060929.JPG
 
Entry  Wed Oct 20 18:17:35 2010, Suresh, Jenne, Update, SUS, PRM assembly 
We have positioned the guide rod and the wire-stand-off on the optic in the axial direction. 
We have selected six magnets whose magnetic strength is +/-5% of their mean strength (180 Gauss).  The measurement was made as follows:
1) each magnet was placed on its  end, on the top of a beaker held upside down. 
Entry  Wed Oct 20 21:33:11 2010, Kevin, Update, PSL, Quarter Wave Plate Optimization 
[Suresh and Kevin]
We placed the quarter wave plate in front of the 2W laser and moved the half wave plate forward. To make both wave plates fit, we had to rotate
one of the clamps for the laser. We optimized the angles of both wave plates so that the power in the reflection from the PBS was minimized and the transmitted
Entry  Thu Oct 21 10:44:56 2010, steve, Metaphysics, Treasure, 1987 supernova tapes plus....? P1060932.JPG
I'm cleaning out to make room for our new optical cabinet. Are we keeping these? There are  ~20  pieces of 10" od 1" wide tapes and
large number of cassettes.
AJW,  Zucker,  Stuart A and Koji were notified in this matter.
Entry  Thu Oct 21 12:15:02 2010, rana, Update, PEM, 6.9 Mag EQ in Gulf of California 

    
        
            Magnitude

           6.9
        
        
            Date-Time

           
            
                Thursday, October 21, 2010 at 17:53:14 UTC
                Thursday,
Entry  Thu Oct 21 01:11:48 2010, rana, Summary, Computers, elog change and rossa tex 
I deleted a bunch of categories from the elogd.cfg file. Not every kind
of locking and activity gets its own activity. All of the things related to length sensing and control should be LSC. If there's a high pollen count its
under PEM. etc., etc., etc.
    Reply  Thu Oct 21 13:05:19 2010, Koji, Summary, Computers, elog change and rossa tex 
This is cool though the projector is flashing the blue screen alternately. 
I gave the dual head video card (ATI RADEON something) to Yuta a month ago. 
Entry  Thu Oct 21 05:51:10 2010, kiwamu, Update, Locking, no green beat note 
 Still I didn't see any beat note signals..
 With a help from Suresh, Yuta and Rana, I tried searching for the green beat note by changing the temperature of the X end NPRO.
The noise level after it goes through an RF amplifier (G=23dB) was about -70dBm at 50MHz.
    Reply  Thu Oct 21 15:59:28 2010, kiwamu, Update, Locking, no green beat note : details bw.png
Last night I tried searching for a beat note signal with two different PD trans impedance gains. 
Although I didn't find a  beat note signal.
 
Entry  Thu Oct 21 18:45:50 2010, Koji, Update, PSL, Found the beat at 1064nm 
[Koji Suresh]
We found the beat at 1064nm. T(PSL)=26.59deg, T(X-end)=31.15deg.
The X-end laser was moved to the PSL table.
    Reply  Thu Oct 21 19:10:39 2010, Aidan, Update, PSL, Found the beat at 1064nm 


       Reply  Fri Oct 22 01:23:13 2010, Koji, Update, PSL, Found the beat at 1064nm 101021_beat.pdf
[Koji / Suresh]
We worked on the 1064 beating a bit more.
- First of all, FSS and FSS SLOW servo were disabled not to have variating Xtal temp for the PSL.
Entry  Fri Oct 22 15:06:43 2010, Jenne, Update, SUS, Arts and Crafts! StatusTable.png
This afternoon I epoxied the guiderod and wire standoff to the new PRM.  I also epoxied the magnets that Suresh picked out to the dumbbell standoffs. 
We'll let them all cure over the weekend, and then I'll glue the magnets to the optic on ~Monday.
Notes about the epoxy: 
Entry  Fri Oct 22 16:59:21 2010, Jenne, Update, Electronics, Epic Takeover 
As the suspension work winds down (we'll be completely done once the ETMs arrive, are suspended, and then are placed in the chambers), I'm going to start
working on the RF system. 
Step 1: Figure out what Alberto has been up to the last few months.
    Reply  Fri Oct 22 18:22:27 2010, Alberto, Update, Electronics, Epic Takeover 


    
        
            Quote:
        
        
            
            As the suspension work winds down (we'll be completely done once the ETMs arrive, are suspended, and then are placed
Entry  Fri Oct 22 19:53:27 2010, yuta, Summary, CDS, conversion failure in digital filters 
(Rana, Joe, Yuta)

We now understand that we never succeeded in converting old fiter files to new filter files.
    Reply  Sat Oct 23 03:36:05 2010, yuta, Update, CDS, fixed filters for C1SUS, C1RMS, C1MCS 
(Joe, Yuta)

Summary:
Entry  Sat Oct 23 14:42:01 2010, yuta, Summary, CDS, damped MC suspensions dam.png
After replacing filters, MC suspensions damped  last night.
Further measurement next time.
Entry  Sun Oct 24 19:55:50 2010, kiwamu, Update, Electronics, lonely RF amplifier on ITMX table 
(Rana, Kiwamu) 



 Last Friday we found a lonely RF amplifier ZHL-3A on the ITMX table. 
Entry  Fri Oct 22 18:15:21 2010, kiwamu, Update, Locking, Green era: found a green beat note finally green_beatnote.jpg
finally we found it !
 
    Reply  Fri Oct 22 21:28:27 2010, Aidan, Update, Locking, Green era: found a green beat note finally 
Nice work!
       Reply  Sun Oct 24 18:06:35 2010, kiwamu, Summary, Locking, setup for green beat green_beat_note.png

(notes on signal level)
          Reply  Mon Oct 25 02:14:38 2010, Koji, Summary, Locking, setup for green beat 
- What is the actual photocurrent for the beam1 and beam2? We don't care how much power do you have before the BS, but care how much current do you have
on the PD.
- How much is the visibility? There is mismatching of the beams. i.e. The beam diameter looked quite different. Also the beams are not TEM00 but
Entry  Fri Oct 22 03:37:56 2010, Kevin, Update, PSL, Quarter Wave Plate Measurements 
[Koji and Kevin]
We measured the reflection from the PBS as a function of half wave plate rotation for five different quarter wave plate rotations. Before the measurement
we reduced the laser current to 1 A, locked the PMC, and recorded 1.1 V transmitted through the PMC. During the measurements, the beam was blocked after
    Reply  Sat Oct 23 02:25:49 2010, Kevin, Update, PSL, Quarter Wave Plate Measurements fits.png


    
        
            Quote:
        
        
            
            [Koji and Kevin]
       Reply  Mon Oct 25 02:25:21 2010, Koji, Update, PSL, Quarter Wave Plate Measurements 
Q1. Suppose the laser beam has a certain (i.e. arbitrary) polarization state but contains only TEM00. Also suppose the PSB is perfect (reflect all S
and transmit all P). What results do you expect from your expereiment?

Q2. Suppose the above condition but the PBS is not perfect (i.e. reflects most of S but also small leakage of P to the reflection port.) How
Entry  Mon Oct 25 11:39:06 2010, Jenne, Update, SUS, Magnets glued to PRM StatusTable.png
This morning I glued the magnets to the PRM.  Now we wait, and tomorrow afternoon (at the earliest), Suresh and I can balance the PRM.
Entry  Mon Oct 25 20:20:59 2010, yuta, Joe, Update, CDS, DAQ channel number etc 
[U][B]Summary:[/B][/U]
  We split the old SDSEN filters to SDSEN, SDSIDE, SDCOIL last week.
  Along with this change, the TP channel number changed unfortunately.
Entry  Mon Oct 25 23:10:06 2010, Koji, Update, IOO, MC is now flashing 
[Suresh / Koji]
The MC mirrors are aligned. Now the flashing of the resonances are visible
on the MC2 CCD
Entry  Tue Oct 26 00:45:08 2010, rana, Update, PSL, New NPRO Diagnostic Wiring Untitled.png

I copy section 6.2 into here to share with you all what the diagnostic
Entry  Tue Oct 26 01:53:21 2010, Joonho Lee, Update, Electronics, Fuction Generator removed. 
Today I worked on how to measure cable impedance directly.
In order to measure the impedance in RF range, I used a function generator which could generate 50MHz signal
and was initially connected to the table on the right of the decks.
Entry  Sun Oct 24 19:23:41 2010, rana, Configuration, elog, ELOG 2.8.0 
[SIZE=4][COLOR=blue][FONT=Comic Sans MS][B]I stopped the ELOG and restarted us on 2.8.0.[/B][/FONT][/COLOR][/SIZE]

To make sure nothing got lost, I killed the old process, copied over the logbooks/, themes/, and elogd.cfg to the new 2.8.0/ directory before starting
    Reply  Mon Oct 25 02:23:47 2010, Koji, Configuration, elog, ELOG 2.8.0 
When I push the reply button, the raw html shows up in the edit window and have to use HTML to write the entry.
Does this happen only to me??? 
Entry  Wed Oct 13 18:01:43 2010, yuta, HowTo, CDS, editting all the similar medm screens 
(Joe, Yuta)

Say, you want to edit all the similar medm screens named C1SUS_NAME_XXX.adl.
    Reply  Thu Oct 14 00:54:12 2010, rana, HowTo, CDS, Bad PSL Quad, so I edited the SUS MEDM screens Untitled.png
We found today that there was some (unforgivably
un-elogged) PSL-POS & PSL-ANG work today. 
The wedge splitter at the end of the PSL table is so terribly dogged that it actually moves around irreversibly if you touch the post a
    Reply  Tue Oct 26 12:45:20 2010, yuta, HowTo, CDS, making a new master file for medm screens 
(Joe, Yuta)

 In elog #3708, we showed how to edit all the similar medm screens easiliy.
Entry  Tue Oct 26 15:57:10 2010, Jenne, Update, SUS, One magnet broken, reglued 
[Jenne, Suresh, Thanh (Bram's Grad Student)]
When we removed the grippers from the magnets on the PRM, one of the face magnets broke off.  This time, the dumbbell remained glued to the
optic, while the magnet came off.  (Usually the magnet and dumbbell will stay attached, and both come off together).  I had 3 spare magnet-dumbbells,
Entry  Tue Oct 26 16:02:55 2010, yuta, HowTo, CDS, things to do after making a new Simulink model 
(Joe,Yuta)

Things to do after making a new Simulink model.
Entry  Tue Oct 26 17:31:17 2010, yuta, Update, CDS, fixed OPLEV stuff and MCL filters optlevMC2.png
(Joe, Yuta)

Background:
    Reply  Tue Oct 26 21:27:02 2010, Jenne, Update, CDS, fixed OPLEV stuff and MCL filters 
Since MC2_TRANS is, in fact, MC2 Transmission, and not an oplev at all (it's not red, and it's not a lever, although it does use a QPD), I propose that
the name be changed to something sensical, since calling it an oplev is completely non-sensical.  The name change should happen sooner rather than
later, to avoid confusion.
Entry  Wed Oct 27 02:26:15 2010, kiwamu, Update, IOO, MC locked  
(Rana, Koji, Suresh, Yuta, Thanh, Kiwamu)
 MC was 
Entry  Wed Oct 27 09:02:29 2010, steve, Update, Electronics, HP4195A is NOT fixed 
www.avalontest.com has fixed the 25MHz oscillation.  Contact: Jim Burnham 760-536-0191
Actually, NOT FIXED.
Entry  Tue Oct 26 22:57:37 2010, Jenne, Configuration, Computers, Why doesn't DTT work?!? 
DTT has only SUS and "X02" channels under C1 in the drop down channel selection menu.  Basically, we can't measure any fast channels with
DTT.  I keep getting the error: "Unable to select testpoints."  Sadface.
Similar things are true for DataViewer.  The same limited number of fast channels, and no data found:
    Reply  Wed Oct 27 10:53:03 2010, josephb, Configuration, Computers, Why doesn't DTT work?!? 
Test points for the SUS channels should be there.  They have been working previously this week.  Possibly break down points include awgtpman,
mx_streams, and the fb itself.  I'll look into that.
As far as other fast channels, there are no other fast front ends running than the suspensions ones we have.  Until additional channels get
Entry  Wed Oct 27 11:34:40 2010, josephb, Update, CDS, Modified rc.local for front end machines 
What was the problem:
On reboot, c1sus was in a strange state.  The epics IOC was running, along with tpman, but there were no loaded front ends.
People had to manually run sudo insmod c1SYSfe.ko.
Entry  Wed Oct 27 11:52:45 2010, josephb, Update, elog, Elog needed to be restarted 
I had to restart the elog on Nodus because it was no longer responding.
Entry  Wed Oct 27 12:32:53 2010, josephb, Update, CDS, fb rebooted to try and fix testpoints 
Problem:
Test points were unavailable last night, even after reboots of c1sus and even restarting the daqd process on the frame builder.
Cause:
Entry  Wed Oct 27 15:38:19 2010, josephb, yuta, Update, CDS, IO chassis with bad timing was taken back to Downs 
Problem:
The front end timing was not working properly for 2 of the IO chassis.  They were not being synced to the 1 PPS signal. 
This prevented the use of RFM for communication between front ends because time stamps on the transmitted data did not match the cycle on the receiving
Entry  Wed Oct 27 16:15:35 2010, Suresh, Update, SUS, Re-glued magnet to the PRM 
Thanh and I re-glued the magnet to the PRM following the procedure outlined by Jenne
The PRM in the gluing fixture has been placed in the little foil house and left to cure for a day.
If all goes well the balancing the PRM will be done tomorrow.
Entry  Wed Oct 27 17:06:48 2010, josephb, Update, CDS, Moved c1iscey chassis and host interface board to c1ioo 
Problem:
Need a working IO chassis connected to c1ioo in order to bring the MC_L into the digital realm, and then
via RFM transmit to the c1sus machine.
Entry  Wed Oct 27 21:33:42 2010, Suresh, Update, Locking, Green from the far end re-obtained 
 
The mirror which was moved during the mode matching of PSL light to the MC (ref elog #3791) has been repositioned.  We once again have the green light from the NPRO on the X (south) arm available on the PSL table. 
Entry  Wed Oct 27 21:51:29 2010, Suresh, Update, PSL, Attenuation of PSL NPRO removed 
The laser power was attenuated to 40 mW yesterday for ensuring that the power built up within the MC does not damage
the optics.  
This however stopped us from the doubling work and besides also reduced the power available for locking the PMC. 
Entry  Thu Oct 28 02:01:51 2010, Kevin, Update, PSL, Filter for 2W Laser tf.PDFoutside.jpginside.jpg
[Rana and Kevin]
I made a low pass filter for the piezo driver for the 2W laser that is now installed. The filter has a pole at 2.9 Hz. The transfer function is
shown in attachment 1.
Entry  Thu Oct 28 03:39:58 2010, yuta, Update, IOO, got very stable MC locking C1IOO_MC_SERVO20101028.pngMCrocks!.png
(Rana, Suresh, Jenne, Kiwamu, Kevin, Yuta)

Summary:
Entry  Thu Oct 28 03:21:35 2010, Suresh, Update, Locking, Aligned the MC2 transmission photodiode 
Yuta and Suresh
The MC2 transmission is seen on
the QPD 
    Reply  Thu Oct 28 04:23:38 2010, rana, Update, IOO, A2L prep 
To get the angle to length signal before the c1ioo processor gets going, we need a length signal. We can use either the error signal or the control signal.
I recommend using the control signal since its not puny. The 4-pin LEMO inputs to the OSEM ADC that Suresh has wired are differential
so we can, in principle, use either the BNC output of the SERVO plug or the 2-pin LEMO output.
Entry  Thu Oct 28 09:16:17 2010, steve, Update, PEM, welding in the vertex area 
Fire-smoke sensors in the vertex area #2-31, 2-30 east, 2-32 south/MC2 and 2-37 old control room area are turned off to accommodate the welding
activity of folding crane. These sensors will be reactivated at 3:30pm today.
Stay out of the 40m lab: IFO room till 6 pm today.
    Reply  Thu Oct 28 13:01:34 2010, steve, Update, PEM, crane repair guys left for the day 


    
        
            Quote:
        
        
            
            Fire-smoke sensors in the vertex area #2-31, 2-30 east, 2-32 south/MC2 and 2-37 old control room area are turned off
Entry  Thu Oct 28 04:28:50 2010, yuta, Update, Green Locking, checked frequency counter SR620 
(Kiwamu, Yuta)

Background:
    Reply  Thu Oct 28 11:54:31 2010, Koji, Update, Green Locking, checked frequency counter SR620 
ZHL-32A is a high power (well..., actually middle power) amplifier with the max output power of +29dBm (~1W!).
It seems to be overkill.
Your signal is so small so you don't need ZHL-32A, but can use small amp which we may have somewhere in the lab.
       Reply  Thu Oct 28 20:08:26 2010, yuta, Update, Green Locking, revised RF amp cascading 
Background:
  Yesterday, I said I will use ZHL-32A for amplifying beat note signal, but as Koji pointed out, ZHL-32A is for medium high power.
  So I changed my mind to use ZFL-1000LN instead. ZFL-1000LN is a low noise RF amp whose maximum