14762
|
Mon Jul 15 18:55:05 2019 |
gautam | Update | IOO | Megatron hard-rebooted |
[koji, gautam]
In addition to c1psl needing a reboot, megatron was un-ssh-able (although it was responding to ping). Clue was that the NPRO PZT control voltage was drifting a lot on the StripTool trace. Koji hard-rebooted the machine. Now IMC is locked, and FSS slow servo is also running. |
14761
|
Mon Jul 15 14:53:40 2019 |
Milind | Update | IOO | keyed psl crate, unstick.py |
Mode cleaner was not locked today. Koji came in and concluded that PSL had died. So we keyed it. Then we ran my unstick.py code. Mode cleaner is locked now.
Quote: |
Today, Gautam keyed the C1PSL crate and we got to test my unstick.py code. It seems to be working fine. Remarks:
- Gautam moved the unstick.py code to /opt/rtcds/caltech/c1/scripts/cds. Therefore, the steps to run this code are now:
- cd /opt/rtcds/caltech/c1/scripts/cds
- python unstick.py c1psl (for the c1psl machine)
- There is now a sleepTime global variable in the code which defines the amount of delay between successive channel toggles. We set this to 1ms and it took the code around 3s to run.
- Gautam was curious to see if this would work even if we set the sleepTime parameter to 0 but decided that that could be tested the next time something was keyed.
- I still need to add the signal handling thing to this code.
Following this, we tested my PMC autolocker code. The code ran for about a minute before achieveing lock. Remarks:
- Gautam moved my code (pmc_autolocker.py and autolocker_config.yaml) to /cvs/cds/rtcds/caltech/c1/scripts/PSL/PMC/ . Therefore, the steps to run this code are now:
- cd /cvs/cds/rtcds/caltech/c1/scripts/PSL/PMC/
- python pmc_autolocker.py (check code or use --help to see what the command line arguments do which is only for when you wanna override the details in the .yaml file)
- Gautam suggested that I add some delay between succesive steps of DC output adjust so that it locks quickly. I'll do that ASAP. For now, it works.
|
|
14760
|
Mon Jul 15 14:09:07 2019 |
Milind | Update | Cameras | CNN LSTM for beam tracking |
I've set up network with a CNN encoder (front end) feeding into a single LSTM cell followed by the output layer (see attachment #1). The network requires significantly more memory than the previous ones. It takes around 30s for one epoch of training. Attached are the predicted yaw motion and the fft of the same. The FFT looks rather curious. I still haven't done any tuning and these are only the preliminary results.
Quote: |
Rana also suggested I try LSTMs today. I'll maybe code it up tomorrow. What I have in mind- A conv layer encoder, flatten, followed by an LSTM layer (why not plain RNNs? well LSTMs handle vanishing gradients, so why the hassle).
|
Well, what about the previous conv nets?
What I did:
- Extensive tuning - of learning rate, batch size, dropout ratio, input size using a grid search
- Trained each network for 75 epochs and obtained weights, predicted motion and corresponding FFT, error etc.
What I observed:
- Loss curves look okay, validation loss isn't going up, so I don't think overfitting is the issue
- Training for over (even) 75 epochs seems to be pointless.
What I think is going wrong:
- Input size- relatively large input size: 350 x 350. Here, the input image size seems to be 128 x 128.
- Inadequate pre-processing.
- I have not applied any filters/blurs etc. to the frames.
- I have also not tried dimensionality reduction techniques such as PCA
What I will try now:
- Collect new data: with smaller amplitudes and different frequencies
- Tune the LSTM network for the data I have
- Try new CNN architectures with more aggressive max pooling and fewer parameters
- Ensembling the models (see this and this). Right now, I have multiple models trained either with same architecture and different hyperparameters or with different architectures. As a first pass, I intend to average the predictions of all the models and see if that improves performance.
|
Attachment 1: cnn-lstm.png
|
|
Attachment 2: fft_yaw.pdf
|
|
Attachment 3: yaw_motion.pdf
|
|
14759
|
Mon Jul 15 03:30:47 2019 |
Kruthi | Update | Calibration-Repair | White paper as a Lambertian scatterer |
I made some rough measurements, using the setup I had used for CCD calibration, to get an idea of how good of a Lambertian scatterer the white paper is. Following are the values I got:
Angle (degrees) |
Photodiode reading (V) |
Ps (W) |
BRDF (per str) |
% error |
12 |
0.864 |
2.54E-06 |
0.334 |
20.5 |
24 |
0.926 |
2.72E-06 |
0.439 |
19.0 |
30 |
1.581 |
4.65E-06 |
0.528 |
19.0 |
41 |
0.94 |
2.76E-06 |
0.473 |
19.8 |
49 |
0.545 |
1.60E-06 |
0.423 |
22.5 |
63 |
0.371 |
1.09E-06 |
0.475 |
28 |
Note: All the measurements are just rough ones and are prone to larger errors than estimated.
I also measured the transmittance of the white paper sample being used (it consists of 2 white papers wrapped together). It was around 0.002 |
Attachment 1: BRDF_paper.png
|
|
14758
|
Mon Jul 15 03:15:24 2019 |
Kruthi | Update | Loss Measurement | Imaging scatterometer |
On Friday, Koji helped me find various components required for the scatterometer setup. Like he suggested, I'll first set it up on the SP table and try it out with an usual mirror. Later on, once I know it's working, I'll move the setup to the flow bench near the south arm and measure the BRDF of a spare end test mass. |
14757
|
Sun Jul 14 00:24:29 2019 |
Kruthi | Update | Cameras | CCD Calibration |
On Friday, I took images for different power outputs of LED. I calculated the calibration factor as explained in my previous elog (plots attached).
Vcc (V) |
Photodiode
reading(V) |
Power incident on photodiode (W)
|
Power incident on GigE (W) |
|
Uncertainity in
slope (counts/𝝁s) |
CF (W-sec/counts) |
16 |
0.784 |
2.31E-06 |
3.89E-07 |
180.4029 |
1.02882 |
2.16E-15 |
18 |
0.854 |
2.51E-06 |
4.24E-07 |
207.7314 |
0.7656 |
2.04E-15 |
20 |
0.92 |
2.71E-06 |
4.57E-07 |
209.8902 |
1.358 |
2.18E-15 |
22 |
0.969 |
2.85E-06 |
4.81E-07 |
222.3862 |
1.456 |
2.16E-15 |
25 |
1.026 |
3.02E-06 |
5.09E-07 |
235.2349 |
1.53118 |
2.17E-15 |
|
Average |
2.14E-15 |
To estimate the uncertainity, I assumed an error of at most 20mV (due to stray lights or difference in orientation of GigE and photodiode) for the photodiode reading. Using the uncertainity in slope from the linear fit, I expect an uncertainity of maximum 4%. Note: I haven't accounted for the error in the responsivity value of the photodiode.
GigE area |
10.36 sq.mm |
PDA area |
61.364 sq.mm |
Responsivity |
0.34 A/W |
Transimpedance gain (at gain = 20dB) |
10^6 V/W +/- 0.1% |
Pixel format used |
Mono 8 bit |
Johannes had reported CF as 0.0858E-15 W-sec/counts for 12 bit images, with measured a laser source. This value and the one I got are off by a factor of 25. Difference in the pixel formats and effect of coherence of the light used might be the possible reasons. |
Attachment 1: CCD_calibration.png
|
|
14756
|
Fri Jul 12 18:54:47 2019 |
Koji | Update | General | Item loan: optical chopper from Cryo Lab |
Optical chopper borrowed from CryoLab to 40m
https://nodus.ligo.caltech.edu:8081/Cryo_Lab/2458 |
14755
|
Fri Jul 12 07:37:48 2019 |
gautam | Update | SUS | M4.9 EQ in Ridgecrest |
All suspension watchdogs were tripped ~90mins ago. I restored the damping. IMC is locked.
ITMX was stuck. I set it free. But notice that the UL Sensor RMS is higher than the other 4? I thought ITMY UL was problematic, but maybe ITMX has also failed, or maybe it's coincidence? Something for IFOtest to figure out I guess. I don't think there is a cable switch between ITMX/ITMY as when I move the ITMX actuators, the ITMX sensors respond and I can also see the optic moving on the camera.
Took me a while to figure out what's going on because we don't have the seis BLRMS - i moved the usual projector striptool traces to the TV screen for better diagnostic ability.
Update 16 July 1515: Even though the RMS is computed from the slow readback channels, for diagnosis, I looked at the spectra of the fast PD monitoring channels (i.e. *_SENSOR_*) for ITMX - looks like the increased UL RMS is coming from enhanced BR-mode coupling and not of any issues with the whitening switching (which seems to work as advertised, see Attachment #3, where the LL traces are meant to be representative of LL, LR, SD and UR channels). |
Attachment 1: 56.png
|
|
Attachment 2: ITMXunstick.png
|
|
Attachment 3: ITMX_UL.pdf
|
|
14754
|
Thu Jul 11 18:15:22 2019 |
gautam | Summary | Electronics | PSL/IOO rack checkout |
I looked at the PSL/IOO racks to check for which boards, if any, require an additional P2 interface, so that we can try and design a generic one for the IMC/CM boards and whatever else may require it. While searching the elog, I saw that Koji and Johannes had already done this, see Koji's elog in this thread. Some remarks:
- D990155 seems to be unused in both PSL and IOO racks. The one in the PSL rack has some LEMO cables plugged in to the front panel, but they go nowhere. So I think that both of these are redundant (in the assessment below, only one was marked redundant).
- In the PSL rack, the "TTFSS Interface", "PSL PMC SERVO", and "DAQ INTERFACE" (which I think is obsolete) cards all have their P2 connectors daisy chained together, going to a cross-connect. Kruthi and I traced this to be going to a cross connect marked "J23-PSLRACK-CCP". In the PSL wiring diagram of which we have a hardcopy in the control room, it looks like these channels are related to the RefCav? So I think this is not required to be interfaced to our new Acromag DAQ system.
Conclusion: Only the IMC Servo and CM boards need their P2 connectors connected to Acromag.It would be helpful to remove the TTFSS Interface board and figure out what exactly the pin-mapping for the backplane connectors are, but I didn't do this today because there is a "High Voltage" line going to the Interface Board and I'm not actually sure of the signal chain for the FSS servo. |
14753
|
Thu Jul 11 17:58:38 2019 |
gautam | Update | Equipment loan | TT suspension --> Downs |
Arnaud has taken 1 TT suspension from the 40m clean lab to Downs for modal testing. Estimated time of return is tomorrow evening. |
14752
|
Thu Jul 11 16:22:54 2019 |
Kruthi | Update | General | Projector lightbulb blown out |
I heard a popping sound in the control room; the projector lightbulb has blown out. |
14750
|
Thu Jul 11 13:09:22 2019 |
gautam | Summary | CDS | P2 interface board |
it will connect to a 15 pin breakout board in the Acromag chassis
Quote: |
It's nice and compact, and the cost of new 15-pin DSUB cables shouldn't be a factor here. What does the 15p cable connect to?
|
|
14749
|
Thu Jul 11 13:08:36 2019 |
Chub | Summary | CDS | P2 interface board |
It's nice and compact, and the cost of new 15-pin DSUB cables shouldn't be a factor here. What does the 15p cable connect to? |
14747
|
Thu Jul 11 12:42:35 2019 |
gautam | Summary | CDS | P2 interface board |
I looked into the design of the P2 interface board. The main difficulty here is geometric - we have to somehow accommodate sufficient number of D-sub connectors in the tight space between the two P-type connectors.
I think the least painful option is to stick with Johannes' design for the P1 connector. For the CM board, the P2 connector only uses 6 pairs of conductors for signals. So we can use a D-15 connector instead of 2 D-37 connectors. Then we can change the PCB shape such that the P1 connector can be accommodated (see Attachment #1). The other alternative would be to have 2 P-type connectors and 3 D-subs on the same PCB, but then we have to be extra careful about the relative positioning of the P-type connectors (otherwise they wont fit onto the Eurocrate). So I opted to still have two separate PCBs.
I took a first pass at the design, the files may be found here. I just auto-routed the connections, this is just an electrical feedthrough so I don't think we need to be too concerned about the PCB trace routing? If this looks okay, we should send out the piece for fab ASAP.
I will work on putting together the EPICS server machine (SuperMicro) this afternoon.
Quote: |
2. D040180 / D1500308 Common Mode Board
CM servo board itself doesn't need any modification. The CM board uses P1 and P2. So we need to manufacture a special connector for CM Board P2. (cf The adapter board for P1 T1800260). See also D1700058.
|
|
Attachment 1: IMG_7728.JPG
|
|
14746
|
Wed Jul 10 22:32:38 2019 |
Milind | Update | Cameras | Convolutional neural networks for beam tracking |
I trained a bunch (around 25 or so - to tune hyperparameters) of networks today. They were all CNNs. They all produced garbage. I also looked at lstm networks with CNN encoders (see this very useful link) and gave some thought to what kind of architecture we want to use and how to go about programming it (in Keras, will use tensorflow if I feel like I need more control). I will code it up tomorrow after some thought and discussion. I am not sure if abandoning CNNs is the right thing to do or if I should continue probing this with more architectures and tuning attempts. Any thoughts?
Right now, after speaking to Stuart (ldas_admin) I've decided on coding up the LSTM thing and then running that on one machine while probing the CNN thing on another.
Update on 10 July, 2019: I'm attaching all the results of training here in case anyone is interested in the future.
Quote: |
I received access today. After some incredible hassle, I was able to set up my repository and code on the remote system. Following this, Gautam wrote to Gabriele to ask him about which GPUs to use and if there was a previously set up environment I could directly use. Gabriele suggested that I use pcdev2 / pcdev3 / pcdev11 as they have good gpus. He also said that I could use source ~gabriele.vajente/virtualenv/bin/activate to use a virtualenv with tensorflow, numpy etc. preinstalled. However, I could not get that working, Therefore I created my own virtual environment with the necessary tensorflow, keras, scipy, numpy etc. libraries and suitable versions. On ssh-ing into the cluster, it can be activated using source /home/millind.vaddiraju/beamtrack/bin/activate. How do I know everything works? Well, I trained a network on it! With the new data. Attached (see attachment #1) is the prediction data for completely new test data. Yeah, its not great, but I got to observe the time it takes for the network to train for 50 epochs-
- On pcdev5 CPU: one epoch took ~1500s which is roughly 25 minutes (see Attachment #2). Gautam suggested that I try to train my networks on Optimus. I think this evidence should be sufficient to decide against that idea.
- On my GTX 1060: one epoch took ~30s. Which is 25 minutes (for 50 epochs) to train a network.
- On pcdev11 GPU (Titan X I think): each epoch took ~16s which is a far more reasonable time.
Therefore, I will carry out all training only on this machine from now.
Note to self:
Steps to repeat what you did are:
- ssh in to the cluster using ssh albert.einstein@ssh.ligo.org as described here.
- activate virtualenv as descirbed above
- navigate to code and run it.
Quote: |
I attempted to train a bunch of networks on the new data to test if the code was alright but realised quickly that, training on my local machine is not feasilble at all as training for 10 epochs took roughly 6 minutes. Therefore, I have placed a request for access to the cluster and am waiting for a reply. I will now set up a bunch of experiments to tune hyperparameters for this data and see what the results are.
|
|
|
14745
|
Wed Jul 10 16:53:22 2019 |
gautam | Update | SUS | PRM watchdog condition modified |
[koji, gautam]
We noticed that the PRM watchdog was tripping frequently. This is a period of enhanced seismic activity. The reason PRM in particular trips often is because the SIDE OSEM has 5x increased transimpedance. We implemented a workaround by modifying the watchdog tripping condition to scale the SD channel RMS by a factor of 0.2 (relative to the UL and LL channels). We restarted the modbus process on c1susaux and tested that the new logic works. Here is the relevant snippet of code:
# Disable fast DAC if variation tests too high
# PRM Side is special, see elog 14745
record(calc,"C1:SUS-PRM_LOGIC")
{
field(DESC,"Tests whether RMS too high")
field(SCAN,"1 second")
field(PHAS,"1")
field(PREC,"0")
field(HOPR,"1")
field(LOPR,"0")
field(CALC,"(A<B)&(C<B)&(0.2*D<B)")
field(INPA,"C1:SUS-PRM_ULPD_VAR NPP NMS")
field(INPB,"C1:SUS-PRM_PD_MAX_VAR NPP NMS")
field(INPC,"C1:SUS-PRM_LLPD_VAR NPP NMS")
field(INPD,"C1:SUS-PRM_SDPD_VAR NPP NMS")
}
The db file has a note about this as well so that future debuggers aren't mystified by a factor of 0.2. |
14744
|
Wed Jul 10 14:57:01 2019 |
Koji | Summary | CDS | Channel recipe for iscaux upgrade |
The list of the iscaux channels and pin assignments were posted to google drive.
The spreadsheet can be viewable by the link sent to the 40m ML. It was shared with foteee@gmail for full access.
Summary
- We need
4 ADC modules
5 DAC modules
5 Binary I/O modules
- Be aware that there are bundled multiple digital I/O channels such as "mbboDirect" and "mbbi".
- The full db record of the new channels need to be inferred from the existing channels.
Necessary electronics modification
1. D990694 whitening filter modification (4 modules)
This module shares the fast and slow channels on the top DIN96pin (P1) connector. Also, the whitening selector (done by an analog signal per channel) is assigned over 17pin of the P1 connector, resulting in the necessity of the second DSUB cable. By migrating the fast channels, we can swap the cable from the P1 to P2. Also, the whitening selectors are concentrated on the first Dsub. (See Attachment1 P1)
2. D040180 / D1500308 Common Mode Board
CM servo board itself doesn't need any modification. The CM board uses P1 and P2. So we need to manufacture a special connector for CM Board P2. (cf The adapter board for P1 T1800260). See also D1700058.
3. D990543A1 LSC Photodiode Interface
PD I/F board has the DC mon channels spread over the 16pin limit. P1 21A can be connected to 6A so that we can accommdate it in the first Dsub.
Also the board uses AD797s. This is not necessary. We can replace them to OP27s. I actually don't know what is happening to those bias control, temp mon, enable, and status. These features should be disables at the I/F and the PDs. (See Attachment2 P1) |
Attachment 1: D990694-B.pdf
|
|
Attachment 2: D990543A1.PDF
|
|
14743
|
Wed Jul 10 14:55:32 2019 |
Koji | Update | General | Projector lightbulb blown out |
In fact the projector is still working. The lamp timer showed ~8200hrs. I just reset the timer, but not sure it was the cause of the shutdown. I also set the fan mode to be "High Altitude" to help cooling. |
14742
|
Wed Jul 10 10:04:09 2019 |
gautam | Update | SUS | Tip-Tilt moved from South clean cabinet to bake lab cleanroom |
Arnaud and I moved one of the two spare TT suspensions from the south clean cabinet to the bake lab clean room. The main purpose was to inspect the contents of the packaging. According to the label, this suspension was cleaned to Class A standards, so we tried to be clean while handling it (frocks, gloves, masks etc). We found that the foil wrapping contained one suspension cage, with what looked like all the parts in a semi-assembled state. There were no OSEMs or electronics together with the suspension cage. Pictures were taken and uploaded to gPhoto. Arnaud is going to plan his tests, so in the meantime, this unit has been stored in Cabinet #6 in the bake lab cleanroom. |
14741
|
Tue Jul 9 22:13:26 2019 |
Milind | Update | Cameras | Convolutional neural networks for beam tracking |
I received access today. After some incredible hassle, I was able to set up my repository and code on the remote system. Following this, Gautam wrote to Gabriele to ask him about which GPUs to use and if there was a previously set up environment I could directly use. Gabriele suggested that I use pcdev2 / pcdev3 / pcdev11 as they have good gpus. He also said that I could use source ~gabriele.vajente/virtualenv/bin/activate to use a virtualenv with tensorflow, numpy etc. preinstalled. However, I could not get that working, Therefore I created my own virtual environment with the necessary tensorflow, keras, scipy, numpy etc. libraries and suitable versions. On ssh-ing into the cluster, it can be activated using source /home/millind.vaddiraju/beamtrack/bin/activate. How do I know everything works? Well, I trained a network on it! With the new data. Attached (see attachment #1) is the prediction data for completely new test data. Yeah, its not great, but I got to observe the time it takes for the network to train for 50 epochs-
- On pcdev5 CPU: one epoch took ~1500s which is roughly 25 minutes (see Attachment #2). Gautam suggested that I try to train my networks on Optimus. I think this evidence should be sufficient to decide against that idea.
- On my GTX 1060: one epoch took ~30s. Which is 25 minutes (for 50 epochs) to train a network.
- On pcdev11 GPU (Titan X I think): each epoch took ~16s which is a far more reasonable time.
Therefore, I will carry out all training only on this machine from now.
Note to self:
Steps to repeat what you did are:
- ssh in to the cluster using ssh albert.einstein@ssh.ligo.org as described here.
- activate virtualenv as descirbed above
- navigate to code and run it.
Quote: |
I attempted to train a bunch of networks on the new data to test if the code was alright but realised quickly that, training on my local machine is not feasilble at all as training for 10 epochs took roughly 6 minutes. Therefore, I have placed a request for access to the cluster and am waiting for a reply. I will now set up a bunch of experiments to tune hyperparameters for this data and see what the results are.
|
|
Attachment 1: predicted_motion_first.pdf
|
|
Attachment 2: pcdev5_time.png
|
|
14740
|
Tue Jul 9 18:42:15 2019 |
gautam | Update | ALS | EX green doubling oven temperature controller power was disconnected |
There was no green light even though the EX NPRO was on. I checked the doubling oven temperature controller and found that its power cable was loose on the rear. I reconnected it, and now there is green light again. |
14739
|
Tue Jul 9 18:17:48 2019 |
gautam | Update | General | Projector lightbulb blown out |
Last documented replacement in Nov 2018, so ~7 months, which I believe is par for the course. I am disconnecting its power supply cable. |
14738
|
Tue Jul 9 18:06:05 2019 |
gautam | Update | LSC | Y-arm ASS in a workable state |
The Y-arm ASS was tuned to be in a workable state. Basically, I followed Koji's recipe.
The SNR of the dither lines in the TRY and YARM control signals were checked - Attachment #1. The dither frequencies are marked with vertical dashed lines (can't figure out how to add 4 cursors in DTT so there's two in each row for a total of 4). A couple of days ago, when I was doing some preliminary checks, I found that the oscillator at 24.91 Hz caused a broadband increase in the TRY noise between DC and ~100 Hz. But today I saw no evidence of such behaviour. So I decided against changing the frequency.
The linearity of the demodulated error signals around the quadratic maxima of the TRY level was checked. I did not, however, investigate in detail the frequency-dependent offset Koji has reported in his elog.
After this work, the TRY level is at 0.95. This is commensurate with the MC trans level being lower by ~7% relative to July 2018. Furthermore, the ASS servo is able to return to TRY~0.95 with a time-constant of ~5 seconds in response to misalignment of the cavity optics. After I investigate the X-arm ASS, I will reset the normalization for TRX and TRY.
Update 645pm: In the spirit of general IFO recovery, I re-centered the ITM and ETM oplev spots, and also the IR beam on the IPPOS QPD to mark the new input pointing alignment (the spot is slightly lower on the AS camera than what I remember). I then tweaked the XARM transmission to maximize it, and re-set the TransMon normalization. I edited the normalization script to comment out the normalizing of the TransMon QPD gains as the QPDs are in some kind of indeterminate state now. Attachment #2 shows the current status, you can also see the normalization being reset. LSC mode disabled for overnight.
Once the XARM ASS is also checked out, I propose moving back to locking the DRMI / PRFPMI configs. |
Attachment 1: ditherFreqs.pdf
|
|
Attachment 2: transRenorm.png
|
|
14737
|
Tue Jul 9 10:37:42 2019 |
Milind | Update | IOO | keyed psl crate, unstick.py, pmc autolocker code- working |
Today, Gautam keyed the C1PSL crate and we got to test my unstick.py code. It seems to be working fine. Remarks:
- Gautam moved the unstick.py code to /opt/rtcds/caltech/c1/scripts/cds. Therefore, the steps to run this code are now:
- cd /opt/rtcds/caltech/c1/scripts/cds
- python unstick.py c1psl (for the c1psl machine)
- There is now a sleepTime global variable in the code which defines the amount of delay between successive channel toggles. We set this to 1ms and it took the code around 3s to run.
- Gautam was curious to see if this would work even if we set the sleepTime parameter to 0 but decided that that could be tested the next time something was keyed.
- I still need to add the signal handling thing to this code.
Following this, we tested my PMC autolocker code. The code ran for about a minute before achieveing lock. Remarks:
- Gautam moved my code (pmc_autolocker.py and autolocker_config.yaml) to /cvs/cds/rtcds/caltech/c1/scripts/PSL/PMC/ . Therefore, the steps to run this code are now:
- cd /cvs/cds/rtcds/caltech/c1/scripts/PSL/PMC/
- python pmc_autolocker.py (check code or use --help to see what the command line arguments do which is only for when you wanna override the details in the .yaml file)
- Gautam suggested that I add some delay between succesive steps of DC output adjust so that it locks quickly. I'll do that ASAP. For now, it works.
|
14736
|
Tue Jul 9 08:33:31 2019 |
gautam | Summary | SUS | ETMX PIT bias voltage changed by ~1V |
After this activity, the DC bias voltage required on ETMX to restore good X arm cavity alignment has changed by ~1.3 V. Assuming a full actuation range of 30 mrad for +/- 10 V, this implies that the pitch alignment of the stack has changed by ~2 mrad? Or maybe the suspension wires shifted in the standoff grooves by a small amount? This is ~x10 larger than the typical change imparted while working on the table, e.g. during a vent.
Main point is that this kind of range requirement should probably be factored in when thinking about the high-voltage coil driver actuation.
Quote: |
We unstuck ETMX by shaking the stack. Most effective was to apply large periodic human sized force to the north STACIS mounts.
|
|
14735
|
Mon Jul 8 21:42:39 2019 |
rana | Update | Cameras | Ghost image due to beamsplitter |
you have to use a BS with a larger wedge angle (5 arcmin ~ 1 mrad) so that the beams don't overlap on the camera |
14734
|
Mon Jul 8 17:52:30 2019 |
Milind | Update | Cameras | Convolutional neural networks for beam tracking |
After the two earthquakes, I collected some data by dithering the optic and recording the QPD readings. Today, I set up scripts to process the data and then train networks on this data. I have pushed all the code to github. I attempted to train a bunch of networks on the new data to test if the code was alright but realised quickly that, training on my local machine is not feasilble at all as training for 10 epochs took roughly 6 minutes. Therefore, I have placed a request for access to the cluster and am waiting for a reply. I will now set up a bunch of experiments to tune hyperparameters for this data and see what the results are.
Trainng networks with memory
I set up a network to handle input volumes (stacks of frames) instead of individual frames. It still uses 2D convolution and not 3D convolution. I am currently training on the new data. However, I was curious to see if it would provide any improved performance over the results I put up in the previous elog. After a bit of hyperparameter tuning, I did get some decent results which I have attached below. However, this is for Pooja's old data which makes them, ah, not so relevant. Also, this testing isn't truly representative because the test data isn't entirely new to the network. I am going to train this network on the new data now with the following objectives (in the following steps):
- Train on data recorded at one frequency, generalize/ test on unseen data of the same frequency, large amplitude of motion
- Train on data recorded at one frequency, generallize/ test on unseen data of a different frequency, large amplitude of motion
- Train on data recorded at one frequency, generalize/ test on unseen data of same/ different frequency, small amplitude of motion
- Train on data at different frequencies and generalize/ test on data with a mixture of frequencies at small amplitudes - Gautam pointed out that the network would truly be superb (good?) if we can just predict the QPD output from the video of the beam spot when nothing is being shaken.
I hope this looks alright? Rana also suggested I try LSTMs today. I'll maybe code it up tomorrow. What I have in mind- A conv layer encoder, flatten, followed by an LSTM layer (why not plain RNNs? well LSTMs handle vanishing gradients, so why the hassle).
Quote: |
The quoted elog has figures which indicate that the network did not learn (train or generalize) on the used data. This is a scary thing as (in my experience) it indicates that something is fundamentally wrong with either the data or model and learning will not happen despite how hyperparameters are tuned. To check this, I ran the training experiment for nearly 25 hyperparameter settings (results here)with the old data and was able to successfully overfit the data. Why is this progress? Well, we know that we are on the right track and the task is to reduce overfitting. Whether, that will happen through more hyperparameter tuning, data collection or augmentation remains to be seen. See attachments for more details.
Why is the fit so perfect at the start and bad later? Well, that's because the first 90% of the test data is the training data I overfit to and the latter the validation data that the network has not generalized well to.
|
|
Attachment 1: Motion.pdf
|
|
14733
|
Mon Jul 8 17:33:10 2019 |
Kruthi | Update | Loss Measurement | Optical scattering measurements |
I came across a paper (see reference) where they have used DAOPHOT, an astronomical software tool developed by NOAO, to study the point scatterers in LIGO test masses using images of varying exposure times. I'm going through the paper now. I think using this we can analyze the MC2 images and make some interesting observations.
Reference: L.Glover et al., Optical scattering measurements and implications on thermal noise in Gravitational Wave detectors test-mass coatings Physics Letters A. 382. (2018) |
14732
|
Sun Jul 7 21:59:28 2019 |
Kruthi | Update | Cameras | Ghost image due to beamsplitter |
The beam splitter (BS1-1064-33-2037-45S) that is currently being used has an antireflection coating on the second surface and a wedge of less than 5 arcmin; yet it leads to ghosting as shown in the figure attached (courtesy: Thorlabs). I'm also attaching its spec sheet I dug up on internet for future reference.
I came across pellicle beamsplitters, that are primarily used to eliminate ghost images. Pellicle beamsplitters have a few microns thick nitrocellulose layer and superimpose the secondary reflection on the first one. Thus the ghost image is eliminated.
Should we go ahead and order them? (https://www.thorlabs.com/newgrouppage9.cfm?objectgroup_id=898
https://www.edmundoptics.eu/c/beamsplitters/622/#28438=28438_s%3AUGVsbGljbGU1&27614=27614_d%3A%5B46.18%20TO%2077.73%5D) |
Attachment 1: ghosting_schematic.png
|
|
Attachment 2: Beamsplitter_spec.pdf
|
|
14731
|
Sun Jul 7 17:54:34 2019 |
Milind | Update | Computer Scripts / Programs | PMC autolocker |
I modified the autolocker code I wrote to read from a .yaml configuration file instead of commandline arguements (that option still exists if one wishes to override what the .yaml file contains). I have pushed the code to github. I started reading about MCMC and will put up details of the remaining part of the work ASAP.
Quote: |
P.P.S. He also said that it would not do to have command line arguments as the main source from which parameters are procured and that .yml files ought to be used instead. I will make that change asap.
|
|
14730
|
Fri Jul 5 23:28:52 2019 |
rana, kruthi | Summary | SUS | ETMX unstuck by shaking the stack |
We unstuck ETMX by shaking the stack. Most effective was to apply large periodic human sized force to the north STACIS mounts.
At first, we noticed that the face OSEMs showed nearly zero variation.
We tried unsticking it through the usual ways of putting large excitations through AWG into the pit/yaw/side DOFs. This produced only ~0.2 microns of motion as seen by the OSEMs.
After the stack shake, we used the IFO ALIGN sliders to get the oplev beam back on the QPD.
The ETMX sensor trends observed before and after the earthquake are attached.
** plots deleted; SOMEONE, tried to take raster images and turn them into PDF as if this would somehow satisfy our vetor graphics requirement. Boo. lpots must be actual vector graphics PDF |
14729
|
Fri Jul 5 22:21:13 2019 |
Koji | Update | SUS | Another M7.1 EQ |
In fact, ETMX was not stuck until the M7.1 EQ today. After that it got stuck, but during the after shocks, all the OSEMs occasionally showed full swing of the light levels. So I believe the magnets are OK. |
Attachment 1: Screenshot_from_2019-07-05_22-19-57.png
|
|
14728
|
Fri Jul 5 21:53:10 2019 |
Koji | Update | SUS | Another M7.1 EQ |
- ITM unstuck now
- IMC briefly locked at TEM00
A series of aftershocks came. I could unstick ITMX by turning on the damping during one of the aftershocks.
Between the aftershocks, MC1~3 were aligned to the previous dof values. This allowed the IMC flashing. Once I got the lock of a low order TEM mode, it was easy to recover the alignment to have a weak TEM00.
Now at least temporarily the full alignment of the IMC was recovered. |
14727
|
Fri Jul 5 20:57:04 2019 |
Koji | Update | SUS | Another M7.1 EQ |
[Kruthi, Koji]
Koji came to the lab to align the IMC/IFO, but found the mirrors are dancing around. Kruthi told me that there was M7.1 EQ at Ridgecrest. Looks like there are aftershocks of this EQ going on. So we need to wait for an hour to start the alignment work.
ITMX and ETMX are stuck. |
Attachment 1: Screenshot_from_2019-07-05_21-03-06.png
|
|
14726
|
Thu Jul 4 18:19:08 2019 |
Milind | Update | Cameras | Convolutional neural networks for beam tracking |
The quoted elog has figures which indicate that the network did not learn (train or generalize) on the used data. This is a scary thing as (in my experience) it indicates that something is fundamentally wrong with either the data or model and learning will not happen despite how hyperparameters are tuned. To check this, I ran the training experiment for nearly 25 hyperparameter settings (results here)with the old data and was able to successfully overfit the data. Why is this progress? Well, we know that we are on the right track and the task is to reduce overfitting. Whether, that will happen through more hyperparameter tuning, data collection or augmentation remains to be seen. See attachments for more details.
Why is the fit so perfect at the start and bad later? Well, that's because the first 90% of the test data is the training data I overfit to and the latter the validation data that the network has not generalized well to.
Quote: |
And finally, a network is trained!
Result summary (TLDR :-P) : No memory was used. Model trained. Results were garbage. Will tune hyperparameters now. Code pushed to github.
More details of the experiment:
Aim:
- To train a network to check that training occurs and get a feel for what the learning might be like.
- To set up the necessary framework to perform mulitple experiments and record results in a manner facilitating comparison.
- To track beam spot motion.
What I did:
- Set up a network that learns a framewise mapping as described in here.
- Training data: 0.9 x 1791 frames. Validation data: 0.1 x 1791 frames. Test data (only prediction): all the 1791 frames
- Hyperparameters: Attachment #1
- Did no tuning of hyperparameters.
- Compiled and fit the models and saved the results.
What I saw
- Attachment #2: data fed to the network after pre-processing - median blur + crop
- Attachment #3: learning curves.
- Attachment #4: true and predicted motion. Nothing great.
What I think is going wrong-
- No hyperparameter tuning. This was only a first pass but is being reported as it will form the basis of all future experiments.
- Too little data.
- Maybe wrong architecture.
Well, what now?
- Tune hyperparmeters (try to get the network to overfit on the data and then test on that. We'll then know for sure that all we probably need is more data?)
- Currently the network has around 200k parameters. Maybe reduce that.
- Set up a network that takes as input (one example corresponding to one forward pass) a bunch of frames and predicts a vector of position values that can be used as continuous data).
Quote: |
I got to speak to Gabriele about the project today and he suggested that if I am using Rana's memory based approach, then I had better be careful to ensure that the network does not falsely learn to predict a sinusoid at all points in time and that if I use the frame wise approach I try to somehow incorporate the fact that certain magnitudes and frequencies of motion are simply not physically possible. Something that Rana and Gautam emphasized as well.
Quote: |
- Network training for beam spot tracking: I will begin training the convolutional network with the data pre-processed as described above. I will also simultaneously prepare data acquired from the GigE and train networks on that. Note: I planned to experiment with framewize predictions and hence did some of the work described above. However, I will restrict the number of experiments on that and perform more of those that use 3D convolution. Rana also pointed out that it would be interesting to have the network output uncertainity in the predictions. I am not sure how this can be done, but I will look into it.
|
|
|
|
Attachment 1: Motion.pdf
|
|
Attachment 2: Error.pdf
|
|
Attachment 3: Learning_curves.pdf
|
|
14725
|
Thu Jul 4 10:54:21 2019 |
Koji | Summary | SUS | Suspension damping recovered, ITMX stuck |
So Cal Earthquake. All suspension watchdogs tripped.
Tried to recover the OSEM damping.
=> The watchdogs for all suspensions except for ITMX were restored. ITMX seems to be stuck. No further action by me for now. |
14724
|
Thu Jul 4 10:47:37 2019 |
Milind | Update | General | Earthquake now |
There was a magnitude 6.6 earthquake just a few minutes ago. I am attaching photographs of the monitor feeds for reference here. Is there a standard protocol to be followed in this situation? I'm looking through the wiki now.
Further, the IMC seems to be misaligned and is not locking!  As Koji has let me know, I really hope this is not too serious and can be fixed easily. |
Attachment 1: after_earthquake2.jpg
|
|
Attachment 2: after_earthquake.jpg
|
|
14723
|
Wed Jul 3 23:53:38 2019 |
Milind | Update | Cameras | data for nns |
Tried collecting data today. Was unable to keep the camera_server code running for any length of time as it threw segfaults. Will take a shot again tomorrow.
Quote: |
The GigE is focused now (judged by eye) and I have closed the lid. I'm attaching a picture of the MC2 beam spot, captured using GigE at an exposure time of 400µs.
What was the solution to resolving the flaky video streaming during the alignment process????
-> I think, the issue was with either the poor wireless network conection or the GigE-PoE ethernet cable.
Quote: |
Turns out, focusing the GigE is actually a bit tricky. With pylon, everytime I change the exposure or the focus, I'm running into the error I had mentioned earlier in one of my elogs; so I tried using the python scripts to interact with the GigE. But whenever I try to change the focal plane distance by rotating the lens coupler, the ethernet cable connection becomes loose and the camera server needs to be relaunched every now and then. Also, everytime we want to change the distance between the lenses, the telescope needs to be dismantled and refocused again. I'll try to come up with a better telescope design for this.
Yesterday, I had focused the GigE using a low exposure time and small aperture of iris, to make sure that we are actually seeing a sharp image of the beam spot. I'm attaching a picture of the beam spot I had clicked while focusing it, unfortunately, I forgot to take a picture after I had focused it completely. I'm also attaching a picture of the final setup for future reference.
Yesterday night, Rana asked me to lock the MC2. I figured that the PSL shutter was closed; I just opened it and was able to see the beam spot on the analog camera screen.
|
|
|
14722
|
Wed Jul 3 11:47:36 2019 |
gautam | Update | BHD | PRC filtering |
A question was raised as to how much passive filtering we benefit from if we pick off the local oscillator beam for BHD from the PRC. I did some simplified modeling of this. For the expected range of arm cavity round trip losses (20-50 ppm), I think that the 40m CARM pole will be between 75-85 Hz. The corresponding recycling gain will be 40-50, with the current PRM. I assumed 1000 ppm loss inside the PRC. The net result is that, assuming the single pole coupled cavity response, we will get ~8-9 dB of filtering at ~200 Hz of the intensity noise of the input laser field to the interferometer if we pick the LO beam off from the PRC (e.g. PR2 transmission), instead of picking it off before.
The next questions are: (i) can we do a sufficiently good job of achieving the required RIN stability on the LO field for BHD without relying on the passive filtering action of the PRC? and (ii) is the benefit of the PRC filtering ruined in the process of routing the LO field from wherever the pickoff happens to the BHD setup? |
Attachment 1: PRCfiltering.pdf
|
|
14721
|
Tue Jul 2 19:36:18 2019 |
aaron | Update | IOO | IMC diagnostics |
The latest in my fling with the PMC. Though PMC trans is back to nominal levels (~0.713 V), we'd still like to understand the PMC noise.
Last time, I took some spectra with the RF probe (Agilent 41800A). I had already measured the PDH error signal by sweeping the PZT at ~1 Hz. The notebook I used for analysis has been updated in /users/aaron/analysis/PDH_calibrate.ipynb. The analysis was the following:
- fit the PDH error signal, assuming a 35.5MHz modulation frequency. Here are the (approximate) fit parameters:
- Mapping of PZT mon voltage to Hz: 5.92 Hz/V_{PZT_mon}
- P_carrier*P_signal: 0.193 W^2
- HV mon voltage on resonance: 0.910 V
- Error signal far off resonance: 0.249 V
- Transmission: 0.00238
- yikes. The nominal transmission is T=0.003. I let this parameter be free as a check, and to avoid overconstraining the data; is this consistent with measurements of the PMC optics' transmission?
- Length: 0.0210 m
- This is consistent with the nominal PMC length
- Using the fit of the full PDH error signal, I am able to plot error signal vs frequency, and fit the linear portion of the carrier PDH signal. The results of this fit are:
- -9.75e-7 V_PDH per Hz
- 0.105 V error signal at DC
- I then divide the power spectra by the squared slope of the linear fit above (V_PDH^2/Hz^2) to get the spectra in Hz^2/rtHz
- I've plotted both the spectrum I took directly at the mixer I using the agilent probe, as well as the spectrum taken by sending the PMC servo card's mixer mon to an SR560 (G=2) then to the spectrum analyzer
There are a few problems remaining:
- There should be a gain of 100 between the mixer I and the servo board's mixer out. It's not clear to me that this is reflected in the spectra. Moreover, the header files on the spectra I grabbed from the Agilent say that the R (mixer I) channel has 20dB of input attenuation, which is also not reflected. If I have swapped the two spectra and not accounted for either the gain of the servo card or the attenuation of the spectrum analyzer, these two gains would cancel, but I'm not confident that's what's going on.
|
Attachment 1: PDH_error.pdf
|
|
Attachment 2: PMC_Error_Spectrum.pdf
|
|
14720
|
Tue Jul 2 17:34:54 2019 |
gautam | Update | LSC | Irides opened up on EY table |
In preparation for the ASS debugging, I decided to check out the beam path on the EY table. In order to be able to do this, I had to setup the POY locking to trigger on AS110 instead of TRY (as is usual for this kind of debugging). Then I could poke an IR card in the beam path without destroying the lock.
There are two irides in the beam path immediately between the vacuum window and the harmonic separator that splits off the IR and green beams. I found that the beam was in fact getting clipped on both of them. It was also somewhat off center on a 2" beamsplitter that sends half of the light to the QPD (currently decommissioned). The purpose of these irides are (I think) to eliminate some ghost reflections of the green beam and also the Oplev beam. I opened up the irides until I felt that there wasn't any more clipping of the IR beam, but the appropriate ghost beams were still getting caught.
I also re-aligned the beam onto the TRY Thorlabs PD so as to better center it on the active area. In summary, the result of this work was that the TRY level went from ~0.6 to ~0.93. There may still be some scope for optimizing this - I tried running the Y-arm ASS scripts, and already, the loops don't run away any more. I'll do the systematic analysis of the servo anyways. But given that the IMC Trans lev el used to be ~15,500 counts and is now ~14,500 counts, I think ~7% drop in TRY level is in line with what we "expect" (assuming the pre-power-degradation TRY level was 1.000).
Note that these irides were installed (I think) by Yuki, and so cannot explain the ASS anomalies of July 2018 (i.e. it does not exonerate in-vacuum clipping of the beam, as Koji had already verified that the in-air path was clean back then). |
14719
|
Tue Jul 2 16:57:09 2019 |
gautam | Update | CDS | c1sus is flaky |
Since the work earlier this morning, the fast c1sus model has crashed ~5 times. Tried rebooting vertex FEs using the reboot script a few times, but the problem is persisting. I'm opting to do the full hard reboot of the 3 vertex FEs to resolve this problem.
Judging by Attachment #1, the processes have been stable overnight. |
Attachment 1: c1sus_timing.png
|
|
14718
|
Tue Jul 2 12:30:53 2019 |
gautam | Update | Electronics | Acromag crate switched to Sorensens |
[chub, gautam]
We crossed off another couple of bullets today.
It took me ~1 hour to realize that c1susaux requries the running of sudo /sbin/ifup eth0 to be run in order to see the martian network - why???
Activity:
- Stopped the c1susaux machine:
- Moved alignment sliders of ITMX and ITMY to 0 as a precaution.
- Shutdown the c1susaux machine so that it doesn't become unhappy with the missing Acromags when we power the unit down.
- Dialled down supply voltages on the +/- 15 V and +/- 20 V DC Sorensens. Current draw became 0 A on the front panel indicators.
- Chub tapped some new terminal blocks for +15 V DC and +20 V DC
- This required some additional daisy chaining, which is why we dialled down the Sorensens.
- New cables were made using the "standard" LIGO color scheme, which isn't really applicable in this case because we are using +15 V DC (orange sheath wire) and + 20 V DC (yellow sheath wire) whereas the closest LIGO standard voltages are +18 V DC and +24 V DC.
- A test cable, presumably meant to be used in the electronics area (orange for +15 V DC) was destroyed for this work as we opted for speed rather than making a new cable.
- Disconnected bench power supplies that were powering the Acromags, and connected the new cables.
- I opted to use 5 A fuses in the terminal blocks for these supplies as the current draw is pretty significant.
- Dialled the Sorensens back up to the nominal voltages:
- Attachment #1 shows the front panels of the Sorensens before and after this work.
- The current limit on the +20 V DC Sorensen had to be raised, because the Acromag box draws ~2.3 A on its own, whereas the previous current draw was 2.8 A.
- Brought the c1susaux machine back online. Took me a while to get to the bottom of why I wasn't able to see c1susaux on the martian, but eventually, I figured out the whole sbin/ifup thingy.
I don't understand the exact chain of causation, but during this work, the fast c1sus model crashed. I had to go through a few iterations of the scripted vertex machine rebooting, but things seem to be back in a normal state now, see Attachment #2. Should probably run the IFO test suite to make sure everything is a-okay, but for now, I am able to lock the IMC so I'm moving on.
The main task remaining here is to take new pictures of everything and upload to the wiki. Also, need to update the Sorensen labels to reflect their current values, some of them are outdated.
Quote: |
- Take photos of the new setup, cabling.
Remove the old c1susaux crate from the rack to free up space, possibly put the PSL monitoring acromag chassis there.
Test that the OSEM PD whitening switching is working for all 8 vertex optics.(verified as of 5/3/19 5pm)
New 15V and 24V power cables with standard LIGO connectors need to be run from the Sorensenn supplies in 1X5. The chassis is currently powered by bench supplies sitting on a cart behind the rack.
All 24 new DB-37 signal cables need to be labeled.
New 96-pin DIN connectors need to be put on two ribbon cables (1Y5_80 B, 1Y5_81) in the 1X4 rack. We had to break these connectors to remove them from the back of the eurcrates.
General cleanup of any cables, etc. left around the rack. We cleaned up most things this evening.
Rename the host computer c1susaux2 --> c1susaux, and update the DNS lookup tables on chiara.
|
|
Attachment 1: 1X5Sorensens.pdf
|
|
Attachment 2: CDS_20190702.png
|
|
14717
|
Tue Jul 2 12:30:44 2019 |
Milind | Update | Computer Scripts / Programs | PMC autolocker |
Just finished a raw version of the autolocker!! Tested it once and was able to achieve lock! This is a python version of the code at /opt/rtcds/caltech/c1/scripts/PSL/PMC/AutoLock.sh.
The current code lives in my users directory. Gautam asked me to put the completed autolocker at /opt/rtcds/caltech/c1/scripts/PSL/PMC/ and that I needn't necessarily put it on git. However, I had previously added it to my Non-linear control repo. Not sure if I should take it off? The current script still lacks some checks like those that enable it to stop after a certain time of attempting to lock or those that handle interrupt signals. Will do that in some time.
P.S. As Koji says, Victory! :-P
P.P.S. Rana pointed out that this is not the objective and what we actually wanna do is run a search over the parameter space of the locking process. I will document my ideas about this process as soon as I do a little more reading. He also said that it would not do to have command line arguments as the main source from which parameters are procured and that .yml files ought to be used instead. I will make that change asap.
Quote: |
I've begun working on this. Steps to complete:
- Convert the autolocker to python. Test that it works.
- Run the script with different settings of the servo gain adjust and DC output adjust parameters and obtain a plot of the average time of lock to determine what the best settings of the aforementioned parameters are.
Quote: |
As Rana asked me to in the last meeting, I dug through the elogs to determine what had become of the previous autolockers. I stumbled upon this elog by Rana from before Gautam cleaned up the medm screen. Out of curiosity, I ran the autolocker script using the instructions in Rana's elog. I did this a total of 5 times and could lock the PMC 3 times fairly quickly. I attempted to decipher the details of the code but did not make much headway owing to my unfamiliarity with the language. From what I could make out from the medm screen while the autolocker was running, it appeared to be the same method as that in this elog. I will take a look at it again tomorrow. However, I intend to spend most of tomorrow working on preprocessing the data, developing the CNN script and then the simulation.
Quote: |
- I shall also begin working on a script to autolock the PMC based on what Rana showed me on Monday. I will also take a look at the the contents of this elog and try to pick up from there. I hope to make significant progress by the next lab meeting.
|
|
|
|
14716
|
Mon Jul 1 20:27:44 2019 |
gautam | Update | ASC | ASX tuning |
Summary:
To practise the dither alignment servo tuning, I decided to make the ASX system work again (mainly because it has fewer DoFs and so I thought it'd be easier to manage). Setup is: dither PZT mirrors on EX table-->demodulate green transmission at the dither frequencies-->Servo the error signals to 0 by an integrator.
Details:
- Started by checking the dither lines are showing up with good SNR in GTRX. They are, see Attachment #1. The dither lines are at 18.23 Hz, 27.13 Hz, 53.49 Hz and 41.68 Hz, and all of them show up with SNR ~100.
- Hand-aligned the beam till I got a maximum of GTRX ~ 0.35. This is lower than the usual ~0.5 I am used to - possibilities are (i) in the process of plugging in the BNC cable to the rear of the EX laser for my PLL investigations, I disturbed the alignment into the SHG crystal ever so slightly and I now have less green light going into the cavity or (ii) there is an iris on the EX table just before the green beam goes into the vacuum on which it is getting clipped. IIRC, I had centered the GTRX camera view such that the spot was well centered in the field of view, but now I see substantial mis-centering in pitch. So the cavity alignment for IR could also be sub-optimal (although I saw TRX ~1.15). Anyways, I decided to push on.
- Introduced a deliberate offset in a given DoF, e.g. M1 PIT. Then I looked at the demodulated error signals (filtered through an RLP0.5 filter post demodulation, so the 2f component should be attenuated by 100 dB at least), and tuned the demod phase until most of the signal appeared in the I-phase, which is what is used for servoing. The Q-phase signals were ~x10 lower than their I-phase counterparts after the tuning.
- Checked the linearity of the error signal in response to misalignment of a given DoF. I judged it to be sufficiently linear for all four DoFs about the quadratic part of the GTRX variation.
- Tweaked the overall servo gains to have the error signals be driven to 0 in ~10 seconds.
- There was quite significant cross-coupling between the DoFs - why should this be? I can understand the PIT->YAW coupling because of imperfect mounting of the PZT mounted mirror in a rotational sense, but I don't really understand the M1->M2 coupling.
- Nevertheless, the servo appears to work - see Attachment #2.
The adjusted demod phases, servo gains were saved to the .snap file which gets called when we run the "DITHER ON" script. Also updated the StripTool template.
I plan to repeat similar characterization on the IR dither alignment servos. I think the tuning of the ASS settings can be done independently of figuring out the mystery of why the TRY level is so low. |
Attachment 1: ASX_ditherlines.pdf
|
|
Attachment 2: ASX.png
|
|
14715
|
Mon Jul 1 20:18:01 2019 |
Milind | Update | Computer Scripts / Programs | PMC autolocker |
I've begun working on this. Steps to complete:
- Convert the autolocker to python. Test that it works.
- Run the script with different settings of the servo gain adjust and DC output adjust parameters and obtain a plot of the average time of lock to determine what the best settings of the aforementioned parameters are.
Quote: |
As Rana asked me to in the last meeting, I dug through the elogs to determine what had become of the previous autolockers. I stumbled upon this elog by Rana from before Gautam cleaned up the medm screen. Out of curiosity, I ran the autolocker script using the instructions in Rana's elog. I did this a total of 5 times and could lock the PMC 3 times fairly quickly. I attempted to decipher the details of the code but did not make much headway owing to my unfamiliarity with the language. From what I could make out from the medm screen while the autolocker was running, it appeared to be the same method as that in this elog. I will take a look at it again tomorrow. However, I intend to spend most of tomorrow working on preprocessing the data, developing the CNN script and then the simulation.
Quote: |
- I shall also begin working on a script to autolock the PMC based on what Rana showed me on Monday. I will also take a look at the the contents of this elog and try to pick up from there. I hope to make significant progress by the next lab meeting.
|
|
|
14714
|
Mon Jul 1 20:11:34 2019 |
Milind | Update | Cameras | Simulation enhancements |
Today, I read a lot more about BRDF and modelling but could not make much headway regarding the implementation in the simulation. I've stopped for now and I'll take a crack at it tomorrow again.
Quote: |
Yesterday, Rana asked me to look at Hiro Yamamoto's docs on the DCC to improve the simulation. I'm performing a first pass (=> Just skimming through to see if they're relevant, I will go through them more carefully soon!) and putting up stuff here for future reference. @Kruthi's help much appreciated!
|
|
14713
|
Mon Jul 1 11:02:05 2019 |
Milind | Update | IOO | PMC and IMC locked again, some MEDM maintenance |
Made changes as discussed in this issue. Further, I need to add signal handling capabilities to the code. I belive Jon has pointed me to some code. I will take a look at that ASAP.
Quote: |
> For channels corresponding to continuous values (such as say exposure time or the like) changes to abs(1+current_value)
Why abs? Is the current_value is like -5.4321 (for example for the alignment slider), this returns +4.4321 and the suspension will suffer from huge motion (well it will be returned to the original value soon though).
|
|
14712
|
Sun Jun 30 23:52:09 2019 |
Koji | Update | IOO | PMC and IMC locked again, some MEDM maintenance |
> For channels corresponding to continuous values (such as say exposure time or the like) changes to abs(1+current_value)
Why abs? Is the current_value is like -5.4321 (for example for the alignment slider), this returns +4.4321 and the suspension will suffer from huge motion (well it will be returned to the original value soon though). |
14711
|
Sun Jun 30 22:21:07 2019 |
Milind | Update | IOO | PMC and IMC locked again, some MEDM maintenance |
Wrote the script. It currently lives at /users/milind/NonlinearControl/milind/unstick/unstick.py. Also pushed it to the repo here. It does the following:
- When run as python unstick.py c1aux (for instance) from the terminal, it parses the autoBurt.req file at /cvs/cds/caltech/target/c1aux/autoBurt.req and obtains the channels.
- Iterates through the channels and changes it to "some value"
- For channels corresponding to buttons on MEDM screen (Enable/Disable etc.) toggles between 0 and 1
- For channels corresponding to continuous values (such as say exposure time or the like) changes to abs(1+current_value)
- Resets to original value and then moves to the next channel
I tried print statements instead of actually writing to the channels as Gautam asked me to do that with supervision. Is this good enough?
Quote: |
a useful piece of code that we should ask one of this summer's SURFs to write:
- read in a BURT .req file which is usually used to make the autosnap / restore.
- change ALL of the values to some value (slightly different from its current value)
- restore it to its current value
this will solve the sticky slider problem and do it in a systematic way. We can run it from the command line: e.g. 'unsticky.py c1psl c1ioo c1lsc'
Quote: |
Aaron complained to me earlier that the PMC could not be locked. Turned out to be a classic sticky slider problem,
|
|
|