40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 53 of 335  Not logged in ELOG logo
ID Date Author Type Category Subject Text Attachments
  14228   Thu Oct 4 00:44:50 2018 yukiConfigurationASCAI board improvement[ Yuki, Gautam ]

I made a cable which connects DAC
port (40 pins) and AI board (25 pins). I
  
  14227   Wed Oct 3 18:15:34 2018 yukiConfigurationASCAI board improvement[ Yuki, Gautam ]

I improved Anti-Imaging board (D000186-Rev.D),
which will be put between DAC port and
 TF_AIboard.pdf 
  14226   Wed Oct 3 14:24:40 2018 yukiConfigurationASCY end table upgrade planInterim Procedure Report:

Purpose

The current setup of AUX Y-arm
  
  14225   Tue Oct 2 23:57:16 2018 gautamUpdatePonderSqueezeSqueezing scenarios[kevin,
gautam]
 PonderSqueeze_NB_LORIN.pdf 
  14224   Tue Oct 2 18:50:53 2018 yukiConfigurationASCPZT mirror calibration[ Yuki, Gautam ]

I calibrated PZT mirrors. The ROUGH
result was attached. (Note that some errors and
 PZTM1calibrationCH2.pdfPZTM1calibrationCH1.pdfPZTM2calibrationCH2.pdfPZTM2calibrationCH1.pdf 
  14223   Mon Oct 1 22:20:42 2018 gautamUpdateSUSPrototyping HV Bias CircuitSummary:

I've been plugging away at
Altium prototyping the high-voltage bias
 CoilDriverBias.pdfcurrentNoise.pdfPSRR.pdf 
  14222   Mon Oct 1 20:39:09 2018 gautamConfigurationASCc1asyWe need to set up a copy of the c1asx   
  14221   Mon Oct 1 13:33:55 2018 yukiConfigurationASCQPD calibration


Quote:


 Pic_QPDcalibration.jpg 
  14220   Mon Oct 1 12:03:41 2018 not yukiConfigurationASCPZT driver board verificationI assume this QPD set is a D1600079/D1600273
combo.

How much was the SUM output during
  
  14219   Sun Sep 30 20:14:51 2018 yukiConfigurationASCQPD calibration[ Yuki, Gautam, Steve ]

Results:
I calibrated a QPD (D1600079, V1009)
 QPDcalibrationXaxis.pdfQPDcalibrationYaxis.pdf 
  14218   Thu Sep 27 14:02:55 2018 yukiConfigurationASCPZT driver board verification[ Yuki, Gautam ]

I fixed the input terminal that
had been off, and made sure PZT driver
 PZTdriverSimulationDiagram.pdfPZTdriverSimulationResult.pdfPZTdriverPerformanceCheck_ResultOUT.pdfPZTdriverPerformanceCheck_ResultMON.pdfPZTdriver.asc 
  14217   Wed Sep 26 10:07:16 2018 SteveUpdateVACwhy reboot c1vac1Precondition: c1vac1 & c1vac2 all LED
warning lights green [ atm3 ], the only error
message is in the gauge readings NO COMM,
 NOcomm.pngReboot_&_sawp.pngc1vac1&2_.jpg 
  14216   Tue Sep 25 18:08:50 2018 yukiConfigurationASCY end table upgrade plan[ Yuki, Gautam ]

We want to remotely control steeing
PZT mirrors so its driver is needed.
  
  14215   Mon Sep 24 15:06:10 2018 gautamUpdateVACc1vac1 reboot + TP1 controller replacement[steve, gautam]

Following the procedure in this
 beforeReboot.pngafterReboot.pngCC1.png 
  14214   Mon Sep 24 11:09:05 2018 yukiConfigurationASCY end table upgrade plan[ Yuki, Steve ]

With Steve's help, we checked
a new lens can be set soon after dichroic
 pic0924_1.jpg 
  14213   Sun Sep 23 20:15:35 2018 KojiSummaryOMCMontecarlo simulation of the phase difference between P and S pols for a modeled HR mirror Link to OMC_Lab
ELOG 308
  
  14212   Sun Sep 23 19:32:23 2018 yukiConfigurationASCY end table upgrade plan[ Yuki, Gautam ]

The setup I designed before has
abrupt gouy phase shift between two steering
 Pic_NewSetup0923_AUXYgreen.jpegModeMatchingSolution_Result.pdfModeMatchingSolution_Magnified_0923.jpgpic0923_1.jpgpic0923_2.jpg 
  14211   Sun Sep 23 17:38:48 2018 yukiUpdateASCAlignment of AUX Y end green beam was recovered[ Yuki, Koji, Gautam ]

An alignment of AUX Y end green
beam was bad. With Koji and Gautam's
  
  14210   Sat Sep 22 00:21:07 2018 KojiUpdateCDSFrequent time out[Gautam, Koji]

We had another crash of c1sus and
Gautam did full power cycling of c1sus. It
 23.png 
  14208   Fri Sep 21 19:50:17 2018 KojiUpdateCDSFrequent time outMultiple realtime processes on c1sus are
suffering from frequent time outs. It eventually
knocks out c1sus (process).
 33.png49.pngScreenshot_from_2018-09-21_21-52-54.png 
  14207   Fri Sep 21 16:51:43 2018 gautamUpdateVACc1vac1 is unresponsiveSteve pointed out that some of the vacuum
MEDM screen fields were reporting "NO
COMM". Koji confirmed that this is a
  
  14206   Fri Sep 21 16:46:38 2018 gautamUpdateCDSNew PCIe fiber installed and routed[steve,
koji, gautam]
 PCIeFiber.pngIMG_5878.JPG 
  14205   Fri Sep 21 09:59:09 2018 yukiConfigurationASCY end table upgrade plan[Yuki, Gautam]

Attachments #1 is the current setup
of AUX Y Green locking and it has
 Pic_CurrentSetup_AUXYgreen.jpegModeMatchingSolution_Current.pdfModeMatchingSolution_Current_Magnified.pdfModeMatchingSolution_Optimized.pdfModeMatchingSolution_Optimized_Magnified.pdf 
  14203   Thu Sep 20 16:19:04 2018 gautamUpdateCDSNew PCIe fiber install postponed to tomorrow[steve,
gautam]
  
  14202   Thu Sep 20 11:29:04 2018 gautamUpdateCDSNew PCIe fiber housed[steve,
yuki, gautam]
 PCIeFiberSwap.pngPCIeFiberSwap_FBrebooted.png 
  14201   Thu Sep 20 08:17:14 2018 SteveUpdateSUSlocal 3.4M earth quakeM3.4 Colton shake did not trip sus.

 
 local_3.4M.png 
  14200   Tue Sep 18 17:56:01 2018 not gautamUpdateIOOPMC and IMC relocked, WFS inputs turned offI restarted the LSC models in the usual
way via the c1lsc reboot script. After doing
this I was able to lock the YARM configuration
  
  14199   Tue Sep 18 14:02:37 2018 SteveUpdatesafety safety trainingYuki Miyazaki received 40m specific basic
safety training.

 
  
  14198   Mon Sep 17 12:28:19 2018 gautamUpdateIOOPMC and IMC relocked, WFS inputs turned offThe PMC and IMC were unlocked. Both were
re-locked, and alignment of both cavities
were adjusted so as to maximize MC2 trans
  
  14197   Wed Sep 12 22:22:30 2018 KojiUpdateComputersSSL2.0, SSL3.0 disabledLIGO GC notified us that nodus had SSL2.0
and SSL3.0 enabled. This has been disabled
now.
  
  14196   Mon Sep 10 12:44:48 2018 JonUpdateCDSADC replacement in c1lsc expansion chassisGautam and I restarted the models on c1lsc,
c1ioo, and c1sus. The LSC system is functioning
again. We found that only restarting c1lsc
  
  14195   Fri Sep 7 12:35:14 2018 gautamUpdateCDSADC replacement in c1lsc expansion chassisLooks like the ADC was not to blame, same
symptoms persist.

 Screenshot_from_2018-09-07_12-34-52.png 
  14194   Thu Sep 6 14:21:26 2018 gautamUpdateCDSADC replacement in c1lsc expansion chassisTodd E. came by this morning and gave us
(i) 1x new ADC card and (ii) 1x roll of 100m
(2017 vintage) PCIe fiber. This afternoon,
 CDSoverview.png 
  14193   Wed Sep 5 10:59:23 2018 wgautamUpdateCDSCDS status updateRolf came by today morning. For now, we've
restarted the FE machine and the expansion
chassis (note that the correct order in which
  
  14192   Tue Sep 4 10:14:11 2018 gautamUpdateCDSCDS status updatec1lsc crashed again. I've contacted
Rolf/JHanks for help since I'm out of
ideas on what can be done to fix this
  
  14191   Wed Aug 29 14:51:05 2018 SteveUpdateGeneraltomorrow morningElectrician is coming to fix one of the
fluorenent light fixture holder in the east
arm tomorrow morning at 8am. He will be out
  
  14190   Wed Aug 29 11:46:27 2018 JonUpdateSUSlocal 4.4M earth quakeI freed ITMX and coarsely realigned the
IFO using the OPLEVs. All the alignments
were a bit off from overnight.
  
  14189   Wed Aug 29 09:56:00 2018 SteveUpdateVACMaglev controller needs serviceTP-1 Osaka maglev controller  [ 
model TCO10M,  ser V3F04J07 ] 
needs maintenance. Alarm led  on indicating 
  
  14188   Wed Aug 29 09:20:27 2018 SteveUpdateSUSlocal 4.4M earth quakeAll suspension tripped. Their damping restored.
The MC is locked.

ITMX-UL & side magnets are
 4.4_La_Verne.png3.4_&_4.4M_EQ.png 
  14187   Tue Aug 28 18:39:41 2018 JonUpdateCDSC1LSC, C1AUX rebootsI found c1lsc unresponsive again today.
Following the procedure in elog
#13935, I ran the rebootC1LSC.sh
 CDS_FE_STATUS.png 
  14186   Tue Aug 28 15:29:19 2018 SteveFrogsPEMRat is cutThe rat is cut by mechanical trap and it
was removed from ITMX south west location.

A nagy kover patkanyt a fogo elkapta
 rat#2.png.png 
  14185   Mon Aug 27 09:14:45 2018 SteveUpdatePEMsmall earth quakes Small earth quakes and suspensions. Which
one is the most free and most sensitive:
ITMX
 small_EQs_vs_SUSs.png 
  14184   Fri Aug 24 14:58:30 2018 SteveUpdateSUSETMX trips againThe second big glich trips ETMX sus. There
were small earth quakes around the glitches.
It's damping recovered.
 glitches.png 
  14183   Fri Aug 24 10:51:23 2018 SteveUpdateVACpumpdown 81 at day 38 

 
 d38.png 
  14182   Fri Aug 24 08:04:37 2018 SteveUpdateGeneralsmall earth quake 

 
 small_EQ.png 
  14181   Thu Aug 23 16:10:13 2018 not KojiUpdateIMCMC/PMC troubleGreat, thanks!




  
  14180   Thu Aug 23 16:05:24 2018 KojiUpdateIMCMC/PMC troubleI don't know what had been wrong, but
I could lock the PMC as usual.
The IMC got relocked by AutoLocker.
  
  14179   Thu Aug 23 15:26:54 2018 JonUpdateIMCMC/PMC troubleI tried unsuccessfully to relock the MC
this afternoon.

I came in to find it in a trouble
  
  14178   Thu Aug 23 08:24:38 2018 SteveUpdateSUSETMX trip follow-upGlitch, small amplitude, 350 counts 
&  no trip.

 ETMX-UL_glitch.pngPEM_4d.png 
  14177   Wed Aug 22 12:22:27 2018 ranaSummaryElectronicsInspection of the possible dual backplane interfaces for Acromag DAQI think we don't need to keep Crystal
Ref: we can change this into a regular Wenzel
box with no outside control or monitoring.
  
ELOG V3.1.3-