  13162   Thu Aug 3 10:51:32 2017 ranaUpdateCDSNDS2 server restarted, /frames mounted on megatronsame issue on NODUS; I edited the /etc/fstab
and tried mount -a, but it gives this error:

controls@nodus|~ 1> sudo
  
  13163   Thu Aug 3 11:11:29 2017 gautamUpdateCDSNDS2 server restarted, /frames mounted on nodusI added nodus' eth0 IP (192.168.113.200)
to the list of allowed nfs clients in /etc/exportfs
on fb1, and then ran sudo mount -a on nodus.
  
  13164   Thu Aug 3 19:46:27 2017 JamieUpdateCDSnew daqd restart procedureThis is the daqd restart procedure:

$ ssh
  
  13165   Thu Aug 3 20:15:11 2017 JamieUpdateCDSdataviewer can not raise test pointsFor some reason dataviewer is not able
to raise test points with the new daqd setup,
even though dtt can.  If you raise a
  
  13166   Fri Aug 4 09:07:28 2017 ranaUpdateCDSCDS system essentially NOT fully recoveredTried getting   
  13185   Thu Aug 10 14:25:52 2017 gautamUpdateCDSSlow EPICS channels -> Frames re-enabledI went into /opt/rtcds/caltech/c1/target/daqd,   
  13189   Fri Aug 11 00:10:03 2017 gautamUpdateCDSSlow EPICS channels -> Frames re-enabledSeems
like something has failed after I did this
  
  13192   Fri Aug 11 11:14:24 2017 gautamUpdateCDSSlow EPICS channels -> Frames re-enabledI commented
out the line pertaining to C0EDCU again,
now full frames are being written
  
  13197   Fri Aug 11 18:53:35 2017 gautamUpdateCDSSlow EPICS channels -> Frames re-enabled


  
  13198   Fri Aug 11 19:34:49 2017 JamieUpdateCDSCDS final bits status updateSo it appears we now have full frames and
second, minute, and minute_raw trends.

We are still not able to raise
  
  13205   Mon Aug 14 19:41:46 2017 JamieUpdateCDSfront-end/DAQ network down for kernel upgrade, and timing errorsI'm upgrading the linux kernel for
all the front ends to one that is supposedly
more stable and won't freeze when we
  
  13207   Mon Aug 14 20:12:09 2017 Jamie, GautumUpdateCDSWeird problem with GPS receiverToday we saw a weird issue with the GPS
receiver (EndRun Technologies Tempus LX). 
GPS timing on fb1 (which is handled via IRIG-B
  
  13211   Tue Aug 15 16:32:42 2017 Jamie, GautumUpdateCDSGPS receiver apparently set to correct mode as "UTC"


  
  13212   Wed Aug 16 14:54:13 2017 gautamUpdateCDSPSL monitoring Acromag EPICS server restarted[johannes,
gautam, jamie]


Made a directory 
  
  13215   Wed Aug 16 17:05:53 2017 JamieUpdateCDSfront-end/DAQ network down for kernel upgrade, and timing errorsThe CDS system has now been up moved to
a supposedly more stable real-time-patched
linux kernel (3.2.88-csp) and RCG r4447 (roughly
 2017-08-16-163725_1366x495_scrot.png 
  13216   Wed Aug 16 17:14:02 2017 KojiUpdateCDSfront-end/DAQ network down for kernel upgrade, and timing errorsWhat's the current backup situation?   
  13217   Wed Aug 16 18:01:28 2017 JamieUpdateCDSfront-end/DAQ network down for kernel upgrade, and timing errors


  
  13218   Wed Aug 16 18:06:01 2017 KojiUpdateCDSfront-end/DAQ network down for kernel upgrade, and timing errorsWe also need to copy chiara's root.
What is the best way to get the full image
of the root FS?
  
  13219   Wed Aug 16 18:50:58 2017 JamieUpdateCDSfront-end/DAQ network down for kernel upgrade, and timing errors


 2017-08-16-184910_1394x488_scrot.png 
  13249   Thu Aug 24 17:36:11 2017 gautamUpdateCDSFSS Slow Python maintenanceA couple of weeks ago, I was trying to
modernize the python version of the FSS Slow
temperature control loops, when I accidentally
  
  13262   Mon Aug 28 16:20:00 2017 gautamUpdateCDS40m files backup situationThis elog is meant
to summarize the current backup situation
  
  13263   Mon Aug 28 17:13:57 2017 ericqUpdateCDS40m files backup situationIn addition to bootable full disk backups,
it would be wise to make sure the important
service configuration files from each machine
  
  13273   Wed Aug 30 10:54:26 2017 gautamUpdateCDSslow machine bootfestMC autolocker and FSS loops were stuck
because c1psl
  
  13279   Thu Aug 31 00:46:57 2017 ranaSummaryCDSallegra -> Scientific Linux 7.3I made a
'LiveCD' on a 16 GB USB stick using
this command after the GUIs didn't work
  
  13282   Thu Aug 31 18:36:23 2017 gautamUpdateCDSrevisiting Acromag Current
status:


There
is a single Acromag ADC unit installed in
 Acromag_EPICS.png 
  13293   Tue Sep 5 14:41:58 2017 gautamUpdateCDSNDS2 server restarted on megatronI was unable to download data using nds2.
Gabriele had reported similar problems a
week ago but I hadn't followed up on
  
  13297   Tue Sep 5 23:02:37 2017 gautamUpdateCDSslow machine bootfestMC autolocker was not working - PCdrive was railed
at its upper rail for ~2 hours judging by
  
  13312   Fri Sep 15 15:54:28 2017 gautamUpdateCDSFB wiper scriptA wiper script is not yet set up for our
new Frame-Builder. The disk usage is ~80%
  
  13317   Mon Sep 18 17:17:49 2017 gautamUpdateCDSFB wiper scriptAfter trying to debug this issue using
the Perl debugger, I concluded that the problem
is in the part of the code that splits the
  
  13318   Mon Sep 18 17:30:54 2017 ChrisUpdateCDSFB wiper scriptAttached is the version of the wiper script
we use on the CryoLab cymac. It works with
perl v5.20.2. Is this different from what
 wiper.pl 
  13319   Mon Sep 18 17:51:26 2017 gautamUpdateCDSFB wiper scriptIt is a little different - specifically,
the way the splitting of the output of the
"du" command into disk usage and
 perlDiff.png 
  13320   Mon Sep 18 18:40:34 2017 gautamUpdateCDSFB wiper scriptI did a further check on the wiper script
by changing the "percent_keep"
from 85.0 to 75.0, and running the script
  
  13331   Tue Sep 26 13:40:45 2017 gautamUpdateCDSNDS2 server restarted on megatronGabriele reported problems with the nds2
server again. I restarted it again.

  
  13332   Tue Sep 26 15:55:20 2017 gautamUpdateCDS40m files backup situationBackups
of the root filesystems of 
  
  13339   Thu Sep 28 10:33:46 2017 gautamUpdateCDS40m files backup situationAfter consulting with Jamie, we reached
the conclusion that the reason why the root
of FB1 is so huge is because of the way the
  
  13340   Thu Sep 28 11:13:32 2017 jamieUpdateCDS40m files backup situation 




  
  13341   Thu Sep 28 23:32:38 2017 gautamHowToCDSpyawgI've modified the __init.py__
file located at /ligo/apps/linux-x86_64/cdsutils-480/lib/python2.7/site-packages/cdsutils/__init__.py
  
  13342   Thu Sep 28 23:47:38 2017 gautamUpdateCDS40m files backup situationThe nodus
backup too is now complete - however,
  
  13344   Fri Sep 29 09:43:52 2017 jamieHowToCDSpyawg 




  
  13345   Fri Sep 29 11:07:16 2017 gautamUpdateCDS40m files backup situationThe FB1   
  13349   Mon Oct 2 18:08:10 2017 gautamUpdateCDSc1ioo DC errorsI was trying to set up a DAC channel to
interface with the AOM driver on the PSL
table.
 c1ioo_CDS_errors.png 
  13350   Mon Oct 2 18:50:55 2017 jamieUpdateCDSc1ioo DC errors


  
  13351   Mon Oct 2 19:03:49 2017 gautamUpdateCDS[Solved] c1ioo DC errorsThis did the trick - I simply ran

sudo
 CDSoverview.png 
  13355   Tue Oct 3 19:39:10 2017 gautamUpdateCDSslow machine bootfestEurocrate key turning reboots for c1susaux,   
  13356   Wed Oct 4 17:18:15 2017 gautamUpdateCDSFree DAC channels in c1lscThere are at least 5 free DAC channels
(4 if you discount the one channel from these
that I am hijacking) available in the 1Y2
  
  13360   Thu Oct 5 11:46:15 2017 gautamUpdateCDSslow machine bootfestMC Autolocker was umnhappy because c1iool0   
  13361   Thu Oct 5 13:58:26 2017 gautamUpdateCDS40m files backup situationThe 4TB HGST drives have arrived. I've
started the FB1 dd
  
  13364   Fri Oct 6 12:46:17 2017 gautamUpdateCDS40m files backup situationLooks to have worked this time around.

  
  13379   Thu Oct 12 14:42:45 2017 gautamUpdateCDSslow machine bootfestSteve reported problems getting the X arm
locked. Alignment sliders were inaccessible.
Eurocrate key turning reboots for 
  
  13381   Mon Oct 16 12:13:38 2017 gautamUpdateCDSMegatron maintenanceWall StripTool traces showed that IMC has
not been locked for at least 8 hours when
I came in this morning. Going to the IMC
  