Entry  Thu Jun 12 11:03:11 2014, Koji, Frogs, General, World Cup Soccer 2014 world_cup.jpg
    Reply  Thu Jun 12 12:30:50 2014, den, Frogs, General, World Cup Soccer 2014 world-cup-2014-mascots.jpg
Entry  Wed Jun 11 14:41:11 2014, Jenne, Update, SUS, Burt restored c1scxepics 
Entry  Fri Oct 18 15:18:49 2013, Steve, Update, PEM, particle count peak or ... PEMcount?.pngPemCountPeak?No.png
    Reply  Tue Oct 22 10:12:33 2013, Steve, Update, PEM, south arm AC intake duct checked PEM0.5micron60d.pngsouthArmIntakeNorth.jpgSouthArmMidIntakeWipe.jpg
       Reply  Wed Jun 11 08:57:49 2014, Steve, Update, PEM, air cond maintenance tomorrow morning 
Entry  Tue Jun 10 12:49:46 2014, Akhil, Update, Computer Scripts / Programs, Interfacing UFC-6000 with Raspberry Pi completed Interfacing_Script.zip
Entry  Mon Jun 9 23:08:58 2014, Jenne, Update, IOO, MC board checkout 
Entry  Mon Jun 9 20:07:53 2014, nicolas, HowTo, Computer Scripts / Programs, Latex (math) in the elog 
Entry  Mon Jun 9 19:02:34 2014, Evan, Eric, Update, Computer Scripts / Programs, SVN is back 
Entry  Mon Jun 9 10:55:48 2014, Nichin, Summary, Electronics, BBPD D1002969-v8 transimpedence measurement PD_transimpedence_measurement.pngresults.pdfcode_and_data.zip
    Reply  Mon Jun 9 16:55:31 2014, Koji, Summary, Electronics, BBPD D1002969-v8 transimpedence measurement 
Entry  Mon Jun 9 09:51:11 2014, Sai Akhil, Update, Electronics, Frequency Error Measurement of UFC-6000 RF Frequency Counter Data_and_Script_Files.zipError_Measurement_FC.pdfError_freq.jpg
Entry  Fri Jun 6 14:56:09 2014, ericq, Update, elog, Aaaaaand we're back! 
Entry  Thu May 29 02:16:02 2014, ericq, Update, LSC, High Bandwidth power recycled Yarm.  quickOLTFs.pdf
    Reply  Thu May 29 14:40:17 2014, Koji, Update, LSC, High Bandwidth power recycled Yarm.  
       Reply  Thu May 29 15:33:55 2014, ericq, Update, LSC, High Bandwidth power recycled Yarm.  
Entry  Tue May 27 21:48:31 2014, Jenne, Update, LSC, X green broadband PD not working???!? ALS_outofloop_27May2013_2.pdf
    Reply  Wed May 28 17:51:48 2014, manasa, Update, LSC, X green broadband PD NOT working 
       Reply  Wed May 28 19:15:38 2014, Koji, Update, LSC, X green broadband PD NOT working 
Entry  Wed May 21 22:15:37 2014, ericq, Update, PSL, PMC relocked 
    Reply  Mon May 26 20:10:14 2014, ericq, Update, PSL, PMC relocked 
       Reply  Wed May 28 14:13:06 2014, manasa, Update, IOO, MC relocked 
Entry  Sat May 24 22:56:57 2014, Jenne, Update, Electronics, Amplifier removed from BeatX path 
    Reply  Mon May 26 07:59:23 2014, Koji, Update, Electronics, Amplifier removed from BeatX path 
       Reply  Tue May 27 11:58:45 2014, Jenne, Update, Electronics, Amplifier removed from BeatX path ALS_outofloop_27May2013.pdf
Entry  Fri May 23 11:58:28 2014, manasa, Update, Green Locking, Y arm green alignment tuned 
Entry  Tue May 20 11:48:22 2014, Steve, Update, SUS, beam dumps added to ETMX_ISCT razorbeamdumps.jpgrazorbeamdumpss.jpg
    Reply  Wed May 21 09:35:33 2014, Steve, Update, SUS, razor beam dumps ETMX_ISCT 9rbdETMY.jpg
       Reply  Thu May 22 11:21:06 2014, Steve, Update, SUS, ETMX oplev ETMXoplev.png
Entry  Tue May 20 02:12:35 2014, Jenne, Update, LSC, ALS X noise investigation ALS_outofloop_19May2013.pdfXbeatSaturate.png
    Reply  Wed May 21 13:20:34 2014, manasa, Update, LSC, ALS X noise from angular motion of mirrors ALSX_OLYerrITM.png
       Reply  Thu May 22 00:30:40 2014, manasa, Update, LSC, ALS X noise from angular motion of mirrors ALSX_OLPerrITM2.pngALSX_OLYerrITM.pngALSX_OLPerrETM.pngALSX_OLYerrETM2.png
Entry  Wed May 21 13:51:19 2014, Steve, Update, safety, scope battery recall 
Entry  Wed May 21 13:18:47 2014, ericq, Update, CDS, Suspension MEDM Bug 
Entry  Wed May 21 11:11:01 2014, manasa, Update, IOO, MC tuned MC_SUS2days.png
Entry  Wed May 21 05:05:39 2014, Jenne, Update, LSC, REFL 165 vs 33 investigations 
Entry  Tue May 20 16:48:52 2014, ericq, Update, LSC, 3f Stability 3fs.pdfCARMsweepPrcFields.pdf
    Reply  Tue May 20 22:42:28 2014, ericq, Update, LSC, 3f Stability PRCangles.pdf
       Reply  Wed May 21 00:18:40 2014, Jenne, Update, LSC, PRMI locked with REFL33 vs. REFL165 PRMI_outofloop_20May2014.pdf
Entry  Fri May 9 01:36:28 2014, rana, Summary, SUS, Optical Lever QPD Sum trends: they're almost all too weak OLtrend.png
    Reply  Mon May 12 22:42:19 2014, rana, Summary, SUS, Optical Lever QPD Sum trends: they're almost all too weak OL-FB.pngarms_140512.pdf
       Reply  Mon May 12 22:52:59 2014, Jenne, Summary, SUS, Optical Lever Filters are all different OpLevFilters.pdf
       Reply  Tue May 13 13:27:58 2014, Steve, Summary, SUS, Optical Lever Servos setting table OLsums.png
          Reply  Tue May 13 17:03:05 2014, Steve, Summary, SUS, ETMX oplev laser replaced 
             Reply  Tue May 13 17:31:32 2014, Jenne, Summary, SUS, ETMX oplev laser replaced: New oplev gains set OLerr_13May2014.pdfOLfb_13May2014.pdf
                Reply  Tue May 13 22:55:57 2014, Jenne, Summary, SUS, ETMX oplev: cleanup 
             Reply  Wed May 14 10:04:06 2014, Steve, Summary, SUS, oplev laser and temperature TempRules.png
                Reply  Tue May 20 09:12:25 2014, Steve, Summary, SUS, ETMX oplev qpd board ETMXOLQPD121.jpgETMXOLQPDface121.jpgETMXolSUM.png
                   Reply  Tue May 20 15:54:39 2014, rana, Summary, SUS, ETMX oplev qpd board 
Entry  Sat May 17 14:48:06 2014, den, Update, PEM, yend sei isolation kit is set IMG_1405.JPGIMG_1406.JPG
    Reply  Mon May 19 22:44:21 2014, den, Update, PEM, xend sei isolation kit is set 
Entry  Mon May 19 09:19:44 2014, Steve, Update, LSC, happy IFO whenthinksareworking.png
Entry  Sun May 18 14:36:04 2014, den, Update, LSC, offsets in 3f and drmi stable lock on 1f prmi_rin.pdfdrmi_power.pngsrc_ol.pdf
    Reply  Sun May 18 17:57:54 2014, rana, Update, LSC, ETMX transients due to unseated bias cable ETMXbiasCableSeated.pdf
Entry  Fri May 16 20:55:18 2014, Jamie, Frogs, lore, un-full-screening Ubuntu windows with F11 
Entry  Fri May 16 10:54:42 2014, ericq, Update, LSC, X Arm ALS Noise coming in and out 
    Reply  Fri May 16 11:22:23 2014, Steve, Update, LSC, X Arm ALS Noise coming in and out 
Entry  Fri May 16 10:48:32 2014, Steve, Update, LSC, Y arm T- qpd is getting light guard extension tube TRYepox.jpg
Entry  Fri May 16 00:25:53 2014, rana, Update, PSL, PMC realign 
    Reply  Fri May 16 09:46:05 2014, Steve, Update, PSL, pointing monitoring 
Entry  Thu May 15 16:46:35 2014, ericq, Update, LSC, Possible Path to AO path AOtransitionSteps.pdfAOtransitionBodes.pdfAOCarmLoop.zip
Entry  Thu May 15 15:10:02 2014, Steve, Update, PEM, seismic activities  DichDay.pngDitchday8am.jpgAztecsGone.jpg
Entry  Thu May 15 02:32:01 2014, Jenne, Update, LSC, Started engaging the AO path, not getting all the way yet TFSR785_15-05-2014_011008.pdf
    Reply  Thu May 15 02:52:51 2014, Jenne, Update, LSC, Started engaging the AO path, not getting all the way yet 
Entry  Tue Jan 7 22:44:45 2014, Jenne, Update, CDS, daqd on fb is segfaulting every ~30 seconds 
    Reply  Tue Jan 7 23:08:01 2014, jamie, Update, CDS, /frames is full, causing daqd to die 
       Reply  Tue Jan 7 23:13:47 2014, jamie, Update, CDS, /frames is full, causing daqd to die 
          Reply  Tue Jan 7 23:50:27 2014, jamie, Update, CDS, /frames space cleared up, daqd stabilized 
             Reply  Tue May 13 17:45:21 2014, rana, Update, CDS, /frames space cleared up, daqd stabilized 
                Reply  Thu May 15 01:42:07 2014, rana, Update, CDS, /frames space cleared up, daqd stabilized 
Entry  Wed May 14 02:37:58 2014, Jenne, Update, LSC, No big locking news 
    Reply  Wed May 14 14:39:31 2014, Jenne, Update, SUS, New buttons on IFO_ALIGN screen Screenshot-Untitled_Window.png
Entry  Tue May 13 03:30:10 2014, Jenne, Update, LSC, Locking activities - no progress ALS_outofloop.pdf
Entry  Tue May 13 00:46:58 2014, rana, HowTo, PSL, PMC relocking 
Entry  Tue Aug 7 16:11:23 2012, steve, Update, SUS, optical table box wall proposal IMG_1479.JPGIMG_1478.JPG
    Reply  Tue Aug 7 16:21:16 2012, rana, Update, SUS, optical table box wall proposal 
    Reply  Mon May 12 14:42:25 2014, steve, Update, endtable upgrade, optical table enclosure wall proposal and table at ETMY Hilite70.jpgETMY-ISCT.jpgRoscoThermashield.pdf
Entry  Mon May 12 10:42:01 2014, rana, Update, SUS, some Arm maintenance 
Entry  Fri May 9 11:23:11 2014, steve, Update, Green Locking, decreased X green light power  
    Reply  Fri May 9 21:18:51 2014, Koji, Update, Green Locking, Reverted X green light power  
Entry  Fri May 9 14:01:24 2014, Jenne, Update, LSC, CM board boost turn-on checkout 17x
Entry  Thu May 8 17:00:56 2014, rana, Q, Summary, LSC, REFL_DC handoff didn't work last night 
    Reply  Fri May 9 04:51:13 2014, ericq, Summary, LSC, REFL_DC handoff didn't work last night 
Entry  Fri May 9 04:09:39 2014, Jenne, Update, LSC, CM board boost turn-on checkout 
Entry  Thu May 8 14:37:02 2014, Jenne, Update, ASC, POP ASC QPD power 
Entry  Wed Nov 13 18:32:04 2013, Nic, Evan, Update, ISS, SR560 ISS loop psl_aom_overhead.jpgaom_driver.jpgloop_on_settings.jpgfxn_gen.jpg40m_iss.pdf
    Reply  Wed Nov 13 19:41:55 2013, Jenne, Update, ISS, ISS AOM 
    Reply  Wed Nov 13 20:02:12 2013, Nic, Evan, Update, ISS, SR560 ISS loop ISS_560_rot.pdfISS_560cal.pdf
       Reply  Fri Nov 15 10:31:45 2013, Steve, Update, ISS, SR560 ISS loop connection ISS.png
       Reply  Thu May 8 02:03:51 2014, rana, Update, ISS, ISS: fuse was blown, repaired, loop back on ISS.pdf
Entry  Thu May 8 00:40:39 2014, ericq, Update, LSC, BNC vs. 2pin LEMO for AO AOcablesWide.pdf
Entry  Wed May 7 23:09:06 2014, rana, jamie, Summary, Computer Scripts / Programs, Ottavia back on network 
Entry  Wed May 7 04:01:44 2014, rana, jenne, Update, LSC, PRFPMI: Common Mode servo using REFL_DC ON, CARM offset still non-zero 
Entry  Tue May 6 19:38:13 2014, Jenne, Update, LSC, Set up for PRFPMI CM locking 
Entry  Fri May 2 03:51:29 2014, rana, Update, LSC, farther into CM MCkicked.png
    Reply  Sun May 4 22:28:54 2014, ericq, Update, LSC, farther into CM OLTF.png
       Reply  Tue May 6 03:17:15 2014, rana, Update, LSC, farther into CM 
          Reply  Tue May 6 17:58:44 2014, ericq, Update, LSC, farther into CM AOTFs.pdf