  14743   Wed Jul 10 14:55:32 2019 KojiUpdateGeneralProjector lightbulb blown outIn fact the projector is still working.
The lamp timer showed ~8200hrs. I just reset
the timer, but not sure it was the cause
  
  14742   Wed Jul 10 10:04:09 2019 gautamUpdateSUSTip-Tilt moved from South clean cabinet to bake lab cleanroomArnaud and I moved one of the two spare
TT suspensions from the south clean cabinet
to the bake lab clean room. The main purpose
  
  14741   Tue Jul 9 22:13:26 2019 MilindUpdateCamerasConvolutional neural networks for beam trackingI received access today. After some incredible
hassle, I was able to set up my repository
and code on the remote system. Following
 predicted_motion_first.pdfpcdev5_time.png 
  14740   Tue Jul 9 18:42:15 2019 gautamUpdateALSEX green doubling oven temperature controller power was disconnectedThere was no green light even though the
EX NPRO was on. I checked the doubling oven
temperature controller and found that its
  
  14739   Tue Jul 9 18:17:48 2019 gautamUpdateGeneralProjector lightbulb blown outLast documented
replacement in Nov 2018, so ~7 months, which
I believe is par for the course. I am disconnecting
  
  14738   Tue Jul 9 18:06:05 2019 gautamUpdateLSCY-arm ASS in a workable stateThe Y-arm ASS was tuned to be in a workable
state. Basically, I followed Koji's recipe.
 ditherFreqs.pdftransRenorm.png 
  14737   Tue Jul 9 10:37:42 2019 MilindUpdateIOOkeyed psl crate, unstick.py, pmc autolocker code- working Today, Gautam keyed the C1PSL crate and
we got to test my unstick.py code. It seems
to be working fine. Remarks:
  
  14736   Tue Jul 9 08:33:31 2019 gautamSummarySUSETMX PIT bias voltage changed by ~1VAfter this activity, the DC bias voltage
required on ETMX to restore good X arm cavity
alignment has changed by ~1.3 V. Assuming
  
  14735   Mon Jul 8 21:42:39 2019 ranaUpdateCamerasGhost image due to beamsplitteryou have to use a BS with a larger
wedge angle (5 arcmin ~ 1 mrad) so that
the beams don't overlap on the camera
  
  14734   Mon Jul 8 17:52:30 2019 MilindUpdateCamerasConvolutional neural networks for beam trackingAfter the two earthquakes, I collected
some data by dithering the optic and recording
the QPD readings. Today, I set up scripts
 Motion.pdf 
  14733   Mon Jul 8 17:33:10 2019 KruthiUpdateLoss MeasurementOptical scattering measurementsI came across a paper (see reference) where
they have used DAOPHOT, an astronomical software
tool developed by NOAO, to study the point
  
  14732   Sun Jul 7 21:59:28 2019 KruthiUpdateCamerasGhost image due to beamsplitterThe beam splitter (BS1-1064-33-2037-45S) that
is currently being used has an antireflection
coating on the second surface and a wedge
 ghosting_schematic.pngBeamsplitter_spec.pdf 
  14731   Sun Jul 7 17:54:34 2019 MilindUpdateComputer Scripts / ProgramsPMC autolockerI modified the autolocker code I wrote
to read from a .yaml configuration file instead
of commandline arguements (that option still
  
  14730   Fri Jul 5 23:28:52 2019 rana, kruthiSummarySUSETMX unstuck by shaking the stackWe unstuck ETMX by shaking the stack. Most
effective was to apply large periodic human
sized force to the north STACIS mounts.
  
  14729   Fri Jul 5 22:21:13 2019 KojiUpdateSUSAnother M7.1 EQIn fact, ETMX was not stuck until the M7.1
EQ today. After that it got stuck, but during
the after shocks, all the OSEMs occasionally
 Screenshot_from_2019-07-05_22-19-57.png 
  14728   Fri Jul 5 21:53:10 2019 KojiUpdateSUSAnother M7.1 EQ- ITM
unstuck now
- IMC briefly locked at TEM00
  
  14727   Fri Jul 5 20:57:04 2019 KojiUpdateSUSAnother M7.1 EQ[Kruthi, Koji]

Koji came to the lab to align the
IMC/IFO, but found the mirrors are dancing
 Screenshot_from_2019-07-05_21-03-06.png 
  14726   Thu Jul 4 18:19:08 2019 MilindUpdateCamerasConvolutional neural networks for beam trackingThe quoted elog has figures which indicate
that the network did not learn (train or
generalize) on the used data. This is a scary
 Motion.pdfError.pdfLearning_curves.pdf 
  14725   Thu Jul 4 10:54:21 2019 KojiSummarySUSSuspension damping recovered, ITMX stuckSo Cal Earthquake. All suspension
watchdogs tripped. 

Tried to recover the OSEM damping. 
  
  14724   Thu Jul 4 10:47:37 2019 MilindUpdateGeneralEarthquake nowThere was a magnitude 6.6 earthquake just
a few minutes ago. I am attaching photographs
of the monitor feeds for reference here.
 after_earthquake2.jpgafter_earthquake.jpg 
  14723   Wed Jul 3 23:53:38 2019 MilindUpdateCamerasdata for nnsTried collecting data today. Was unable
to keep the camera_server code running for
any length of time as it threw segfaults.
  
  14722   Wed Jul 3 11:47:36 2019 gautamUpdateBHDPRC filteringA question was raised as to how much passive
filtering we benefit from if we pick off
the local oscillator beam for BHD from the
 PRCfiltering.pdf 
  14721   Tue Jul 2 19:36:18 2019 aaronUpdateIOOIMC diagnosticsThe latest in my fling with the PMC. Though
PMC trans is back to nominal levels (~0.713
V), we'd still like to understand the
 PDH_error.pdfPMC_Error_Spectrum.pdf 
  14720   Tue Jul 2 17:34:54 2019 gautamUpdateLSCIrides opened up on EY tableIn preparation for the ASS debugging, I decided   
  14719   Tue Jul 2 16:57:09 2019 gautamUpdateCDSc1sus is flakySince the work earlier this morning, the
fast c1sus model has crashed ~5 times. Tried
rebooting vertex FEs using the reboot script
 c1sus_timing.png 
  14718   Tue Jul 2 12:30:53 2019 gautamUpdateElectronicsAcromag crate switched to Sorensens[chub, gautam]

We crossed off another couple of
 1X5Sorensens.pdfCDS_20190702.png 
  14717   Tue Jul 2 12:30:44 2019 MilindUpdateComputer Scripts / ProgramsPMC autolockerJust finished a raw version of the autolocker!!
Tested it once and was able to achieve lock!
This is a python version of the code at /opt/rtcds/caltech/c1/scripts/PSL/PMC/AutoLock.sh.
  
  14716   Mon Jul 1 20:27:44 2019 gautamUpdateASCASX tuningSummary:

To practise the dither alignment
servo tuning, I decided to make the ASX system
 ASX_ditherlines.pdfASX.png 
  14715   Mon Jul 1 20:18:01 2019 MilindUpdateComputer Scripts / ProgramsPMC autolockerI've begun working on this. Steps to
complete:


Convert the autolocker
  
  14714   Mon Jul 1 20:11:34 2019 MilindUpdateCamerasSimulation enhancements Today, I read a lot more about BRDF and
modelling but could not make much headway
regarding the implementation in the simulation.
  
  14713   Mon Jul 1 11:02:05 2019 MilindUpdateIOOPMC and IMC locked again, some MEDM maintenanceMade changes as discussed in this
issue. Further, I need to add signal handling
capabilities to the code. I belive Jon has
  
  14712   Sun Jun 30 23:52:09 2019 KojiUpdateIOOPMC and IMC locked again, some MEDM maintenance> For channels corresponding
to continuous values (such as say exposure
time or the like) changes to abs(1+current_value)
  
  14711   Sun Jun 30 22:21:07 2019 MilindUpdateIOOPMC and IMC locked again, some MEDM maintenanceWrote the script. It currently lives at
/users/milind/NonlinearControl/milind/unstick/unstick.py.
Also pushed it to the repo here.
  
  14710   Sun Jun 30 22:02:26 2019 MilindUpdateCamerasKeyed c1aux crateI wanted to try out the unstick.py script
on c1aux but kept running into timeout errors.
I was also confronted by a blank GigE screen.
  
  14709   Sun Jun 30 19:47:09 2019 ranaUpdateIOOIMC WFS agendawe are thinking of doing a sprucing up
of the input mode cleaner WFS (sensors +
electronics + feedback loops)
 WFS-Head.pdf 
  14708   Sat Jun 29 03:11:18 2019 KruthiUpdateCamerasCCD CalibrationFinding the gain of the Photodiode:
The three-position rotary switch of the photodiode
being used (PDA520) wasn't working, so
 calibration_setup.jpgCCD_calibration_2.jpegGigE_spectral_response_curve.png152_calibration_plot.png 
  14706   Thu Jun 27 20:48:22 2019 MilindUpdateCamerasConvolutional neural networks for beam trackingAnd
finally, a network is trained!

Result summary (TLDR :-P)
 readme.txtframe0.pdfLearning_curves.pngMotion.png 
  14705   Thu Jun 27 14:28:12 2019 gautamUpdateLSCPOX and POY lockingAfter a more systematic alignment effort,
I was able to get the spots better centered
on the optics (judged by eye from the analog
  
  14704   Wed Jun 26 21:01:26 2019 gautamUpdateLSCPOX and POY lockingNow that the IMC is remaining locked for
extended periods of time, the next problem
to attack is the ASS dither alignment system.
  
  14703   Wed Jun 26 20:45:03 2019 gautamUpdateCamerasField of view optionsFor the beam spot position tracking, I
am wondering if there is any benefit to going
for a wider field of view and getting the
  
  14702   Wed Jun 26 19:12:00 2019 KruthiUpdateCamerasGigEThe GigE is focused now (judged by eye)
and I have closed the lid. I'm attaching
a picture of the MC2 beam spot, captured
 MC2_GigE_image.pdf 
  14701   Wed Jun 26 18:28:24 2019 ranaUpdateIOOPMC and IMC locked again, some MEDM maintenancea
useful piece of code that we should ask one
  
  14700   Wed Jun 26 11:11:40 2019 MilindUpdateIOOPMC and IMC locked again, some MEDM maintenanceAfter helping Aaron key the crate and do
a burt restore, I realized that it would
probably be best to record the steps that
 burtgooey.pdf 
  14699   Wed Jun 26 10:55:13 2019 aaronUpdateIOOPMC and IMC locked again, some MEDM maintenanceThe PMC was locking again after Gautam's
steps above. However, after I added the directional
coupler between the mixer I and the servo
  
  14698   Tue Jun 25 23:52:37 2019 MilindUpdateCamerasSimulation enhancements Yesterday,
Rana asked me to look at Hiro Yamamoto's
  
  14697   Tue Jun 25 22:14:10 2019 MilindUpdateCamerasConvolutional neural networks for beam trackingI discussed this with Gautam and he asked
me to come up with a list of signals that
I would need for my use and then design the
  
  14696   Tue Jun 25 15:32:16 2019 gautamUpdateIOOPMC and IMC locked again, some MEDM maintenanceAaron complained to me earlier that the
PMC could not be locked. Turned out to be
a classic sticky slider problem, I keyed
 PMCctrl.png 
  14695   Tue Jun 25 11:54:47 2019 KruthiUpdateCamerasGigETurns out, focusing the GigE is actually
a bit tricky. With pylon, everytime I change
the exposure or the focus, I'm running
 MC2_GigE.pdfCameras_final_setup.JPG 
  14694   Tue Jun 25 00:25:47 2019 MilindUpdateCamerasConvolutional neural networks for beam trackingIn the previous meeting, Koji pointed out
(once again) that I should determine if the
displacement values and frames are synchronized
 8x 
  14693   Mon Jun 24 15:49:05 2019 aaronUpdateIOOIMC diagnosticsaI went to repeat these measurements using
the mixer out channel from the servo box,
and with a slower sweep for the PDH calibration.
 sweep_config_updated.png 