  15249   Wed Mar 4 16:18:31 2020 gautamUpdateElectronicsMore cabling removedAfter discussing with Koji, I removed the
PZT driver and associated AI card from the
Eurocrate at 1X2. The corresponding backplane
 1X2EuroBefore.JPGIOO.png 
  15248   Wed Mar 4 12:25:11 2020 gautamUpdateCDSBIO1 on c1psl is deadThere was some work done on the Acro crate
this morning. Unclear if this is independent,
but I found that the IMC servo board IN1
  
  15247   Wed Mar 4 11:16:37 2020 gautamUpdatePSLPMC realignmentI realigned the input pointing into the
PMC this morning. Usually, the way I do this
is to minimize any discernible mode structure
 PMCrealignment.png 
  15246   Wed Mar 4 11:10:47 2020 YehonathanUpdateComputersAllegra revivalAllegra had no network cable and no mouse.
We found Allegra'snetwork cable (black)
and connected it.
  
  15245   Tue Mar 3 19:11:48 2020 gautamUpdateLSCSome locking prep
Re-aligned and locked the arm cavities
for IR and green.
Re-set trans
normalization because after the c1iscex
  
  15244   Tue Mar 3 18:11:05 2020 JonSummaryBHDProjected IFO noise budget, post-BHD upgradeRevised noise estimates, correcting a couple
of factor of 2 and factor of pi errors found
in the coil driver noise calculation. Also
 40m_phase_quad.pdf40m_ampl_quad.pdf40m_aligo_comp.pdf 
  15243   Tue Mar 3 17:59:33 2020 YehonathanUpdateElectronicsPSL Shutter and PMC TRANSPD workingI used existing BNC cables running from
the PSL table to the PSL rack and reassigned
them to the PSL Shutter and PMC transmission
  
  15242   Tue Mar 3 17:20:14 2020 gautamUpdateElectronicsMore cabling removedJordan and I removed another 10 kg of cabling
from 1X2. The c1iool0 crate now has all cabling
to it disconnected - but it remains in the
  
  15241   Mon Mar 2 23:49:03 2020 JonSummaryBHDProjected IFO noise budget, post-BHD upgradeUpdated noise budget curves, now computed
using the latest version of pygwinc. This
resolves the inconsistency between the gwinc
 40m_phase_quad.pdf40m_ampl_quad.pdf40m_aligo_comp.pdf 
  15240   Mon Mar 2 19:32:41 2020 gautamUpdateCDSc1rfm errorsHad to reboot both end machines and the
c1rfm model to get the TRX and TRY signals
to the LSC models. Now both arms can be locked
 RFMerrors.png 
  15239   Mon Mar 2 16:35:12 2020 gautamUpdateCDSc1psl test statusChannel   
  15238   Mon Mar 2 16:29:40 2020 gautamUpdateElectronicsc1psl VME crate removed, Acro-crate installed[JV, JWR, YD, GV]


The old c1psl VME crate,
and all the ribbon cables connected to it
 c1psl.pdf 
  15237   Mon Mar 2 16:14:47 2020 gautamUpdateCDSsome target directory cleanup$TARGET_DIR   
  15236   Fri Feb 28 19:37:18 2020 gautamUpdatePSLNew c1psl installed
The new c1psl Acromag crate is
now interfaced to the Eurocrate electronics
in 1X1 (formerly VME c1psl) and 1X2 (formerly
  
  15235   Fri Feb 28 10:04:41 2020 gautamUpdatePSLc1psl setup setupSummary:

There are several problems evident
already.
  
  15234   Fri Feb 28 08:05:22 2020 gautamUpdatePSLc1psl setup setupAnd so it begins.

  
  15233   Thu Feb 27 22:45:40 2020 gautamUpdateALSALS noise highThere was some UNELOGGED work at EX today.
The DFD outputs were also hijacked for loss
measurement. Unclear
 ALSnoise.pdf 
  15232   Thu Feb 27 17:59:02 2020 gautamUpdateLSCSome AO thoughtsWhile my checks of the AO signal path have
thrown up some unanswered questions, I don't
think there's any evidence in those measurements
  
  15231   Thu Feb 27 17:50:36 2020 gautamUpdatePSLc1psl setup setup[many people]

in prep for the install tomorrow,
we did the following:
 20200227_173535.jpg20200227_173454_HDR.jpg20200227_172659.jpg 
  15230   Thu Feb 27 15:50:37 2020 gautamUpdateElectronicsFSS box power cable removedIn 1X1, there is a box labelled "FSS
REF" below a KEPCO HV supply. This box
had a power cable that wasn't actually
  
  15229   Wed Feb 26 23:50:51 2020 gautamUpdateIOOIMC checksIn the style of the KA characterization
of the CM board, the AO path gain EPICS slider
(IN2) of the IMC servo board was stepped
 sliderCal.pdfAO_inputTFs.pdf 
  15228   Wed Feb 26 22:09:52 2020 gautamSummaryBHDProjected IFO noise budget, post-BHD upgradeThe quantum noise curves here are not correct.
c.f. amplitude quadrature noise
budget.
  
  15227   Wed Feb 26 22:05:06 2020 gautamUpdateIOOIMC checksToday, I did the following tests (and so
was touching electronics/cables at/around
1X2):
  
  15226   Wed Feb 26 21:43:48 2020 JonSummaryBHDProjected IFO noise budget, post-BHD upgradeTo supplement the material presented during
the BHD review, I've put together a projected
noise budget for the 40m. Note these are
 40m_phase_quad.pdf40m_aligo_comp.pdf40m_ampl_quad.pdfnoise_budget.tar 
  15225   Wed Feb 26 17:17:17 2020 YehonathanUpdate Arms DC loss measurements{Yehonathan, Gautam}

In order to measure the loss in
the arm cavities in reflection, we use the
 6x 
  15224   Tue Feb 25 19:58:06 2020 HangUpdateIOOMC2 coil balancing[Yehonathan, Hang]

We did some quick DC balancing
of the MC2 coil drivers to reduce the l2a
  
  15223   Tue Feb 25 16:17:57 2020 Gautam, HangUpdateCDS Seems that the GPS is out of sync on donatella.
We could not get any data from diaggui...
  
  15222   Mon Feb 24 08:36:32 2020 ChubUpdateGeneralHVAC repairThe HVAC people replaced a valve and repaired
the pneumatic plumbing on the roof air handler. 
Temperature has been stable during the day
  
  15221   Sun Feb 23 18:15:22 2020 ranaUpdateALSALS OOL noise and PDHto
make the comparisons meaningfully
  
  15220   Fri Feb 21 20:44:18 2020 shrutiUpdateALSALS OOL noise and PDH[Meenakshi, Shruti]

In order to adjust the relative
phase for PDH locking, we used the Siglent
 ALSNoise.pdfIMG_0086.jpg 
  15219   Fri Feb 21 13:02:53 2020 KojiUpdateALSPDH error signals?Check out this elog:
ELOG
4354
  
  15218   Fri Feb 21 10:59:08 2020 shrutiUpdateALSPDH error signals?   IMG_0082.jpgIMG_0083.jpgIMG_0084.jpgIMG_0085.jpg 
  15217   Wed Feb 19 22:20:22 2020 ranaUpdateALSALS OOL noise with arms lockedCould you please put physical units on
the Y-axis and also put labels in the legend
which give a physical description of what
  
  15216   Tue Feb 18 18:14:59 2020 shrutiUpdateALSALS OOL noise with arms lockedWe proceeded with the trying to measure
the ALS out-of-loop noise of the X arm when
the X arm cavity is green-locked using different
 ALSNoise.pdf 
  15215   Sat Feb 15 12:56:24 2020 YehonathanUpdateIOOIMC Transfer function measurement{Yehonathan, Meenakshi}

We measure the IMC transfer function
using SR785.
 IMCFrequencyResponse.pdfIMCRingdownNormalizedRawdata.pdfIMCREFLPDFits.pdf 
  15214   Fri Feb 14 14:52:41 2020 gautamUpdateALSALS OOL noise with arms lockedUnlikely, the alignment was probably just
not good. I restored the alignment and now
the arms can be locked to IR frequency.
  
  15213   Fri Feb 14 14:02:13 2020 shrutiUpdateALSALS OOL noise with arms locked[Meenakshi, Shruti]

Even though we were not able to
lock the the IR beat (by enabling LSC) during
 819472_10.pdf225642_10.pdf693500_10.pdf 
  15212   Fri Feb 14 00:53:50 2020 gautamUpdateALSFast ALS - more setupIn the process of setting up some cabling
at 1Y2, I must've bumped a cable to the
c1lsc expansion chassis. Anyways, the c1lsc
 CMSlow_ALSnoise.pdfOLTFmeas.pdf 
  15211   Thu Feb 13 21:30:55 2020 shrutiUpdateALSALS OOL noise with arms locked[Meenakshi, Gautam, Shruti]

Summary:

- We initially aligned the arm
 20200213_ALS.pdf 
  15210   Thu Feb 13 02:07:26 2020 gautamUpdateLSCAO path transfer function measurementSummary:

I measured the transfer function
of the AO path, and think that there are
 AOpathTF.pdfIMCinLoop.pdf 
  15209   Thu Feb 13 01:47:39 2020 gautamUpdateALSFast ALS - delay line prepA few years ago, Koji and I setup a delay
line phase shifter, which can be used to
impart a (switchable) delay to a signal path.
 delaySlider.pngdelayLineLosses.pdfdelayLineCal.pdf 
  15208   Wed Feb 12 12:13:37 2020 gautamUpdateLSCAO path attemptsSummary:


​The
PRFPMI can be controlled by a mix of ALS
 CARM_OLTF.pdfPRFPMI_errSigs.pdf 
  15207   Tue Feb 11 19:11:35 2020 shrutiUpdateComputer Scripts / ProgramsMATLAB on donatellaTried to open MATLAB on Donatella and found
the error:


MATLAB is selecting
  
  15206   Tue Feb 11 16:39:00 2020 shrutiUpdateALSAM/PMThe results of the AM/PM measurements:


Attachment 1: Traces
of 9 AM TFs overlaid on top of each other,
 AM.pdfPM.pdfRatio_all.pdfRatios_FM_PM.pdfRatio_all_new.pdf 
  15205   Mon Feb 10 15:55:46 2020 JordanUpdatePSLPMCTRANSPD[Gautam, Jordan]

Gautam showed me how the PMCTRANSPD
signal was reading zero, and he suspected
 ADC1.jpg 
  15204   Mon Feb 10 15:54:47 2020 JordanUpdatePSLCompleted Acromag WiringAll spare channels on the PSL acromag chassis
are connected with ~12in of spare wiring
for future use.
  
  15203   Mon Feb 10 15:04:42 2020 JordanUpdateGeneralHDMI Routing for new tv Ran HDMI to the new tv mounted on the north
wall of control room.
  
  15202   Mon Feb 10 10:07:20 2020 gautamUpdatePSLPMC re-lockedI found the PMC unlocked this morning.
It was re-locked using the usual procedure.
I feel like this has been happening more
 PMCunlock.png 
  15201   Mon Feb 10 09:40:54 2020 Larry WallaceSummaryGeneralSolidWorks Computer Upgrade and Printer repairOn February 5, 2020, the Dell engineering
workstation located in the 40M lab, was
replaced with a newer Engineering workstation,
  
  15200   Fri Feb 7 19:39:10 2020 KojiUpdateLSCMore high BW POY experimentsThis measurement tells you how the gain
balance between the SLOW_CM and AO paths
should be. Basically, what you need is to
  
ELOG V3.1.3-