  103   Wed Nov 14 17:50:00 2007 tobinUpdatePSLISSHere's the current wiring between the ISS
and its PDs:
  
  104   Thu Nov 15 04:18:11 2007 JohnSummaryPSLPMC cavity pole measurementsIn connection with our work on the ISS I attempted
to measure the PMC cavity pole.
 Peaks.jpg 
  105   Thu Nov 15 17:09:37 2007 pkpUpdateOMCVertical Transfer functions with no cables attached.[Norna Pinkesh]

The cables connecting all the electronics
 VerticaltransferfuncnocablesattachedNov152007.pdf 
  106   Thu Nov 15 18:06:06 2007 tobinUpdateComputersalex: linux1 root file system hard disk's dyingI just noticed that Alex made [url=http://www.ldas-sw.ligo.caltech.edu/ilog/pub/ilog.cgi?group=40m&date_to_view=11/14/2007&anchor_to_scroll_to=2007:11:14:20:00:29-aivanov]an
entry in the old ilog[/url] yesterday, saying:
"[color=red][b]Looks like linux1 root filesystem
  
  107   Thu Nov 15 18:23:55 2007 JohnHowToComputersSwap CAPS and CTRL on a Windows 2000/XP machineI've swapped ctrl and caps on the four control
room Windows machines. Right ctrl is unchanged.
  
  108   Thu Nov 15 18:36:48 2007 JohnSummary PSL table workI've rotated the lambda/2 plate to 340deg
(from 6 deg) and blocked one arm of the Mach-Zender.
Undo both if you need to.
  
  109   Thu Nov 15 18:37:06 2007 tobinUpdateComputerspossible replacement for linux1's diskIt looks like the existing disk in linux1
is a Seagate ST380013A (this can be found
either via the smartctl utility or by looking
  
  110   Fri Nov 16 11:27:18 2007 tobinUpdateComputersscript fixI added a tidbit of code to "LIGOio.pm" that
fixes a [url=http://lhocds.ligo-wa.caltech.edu:8000/40m/EZCA]problem
with ezcastep on Linux[/url].  Scripts such
  
  111   Fri Nov 16 14:11:26 2007 tobinUpdateComputersop140Alan called to say that Phil Ehrens will be
coming by to take [b]op140[/b] off our hands.
  
  112   Fri Nov 16 14:31:43 2007 tobinUpdateComputersop140 disksPhil Ehrens stopped by and took op140's disks.  DSC_0173.JPG 
  113   Fri Nov 16 18:46:49 2007 steveBureaucracyPSL MOPA was turned off & onThe "Mohana" boys scouts and their parents
visited the 40m lab today.
The laser was turned off for their safety.
  
  114   Mon Nov 19 14:19:25 2007 steveOmnistructurePEMjackhammerThe construction personal successfully jackhemmered
a fence around the "Drever's parking slot"
There is no parking space available close
 jackhammer.jpgjackhammer2.jpg 
  115   Mon Nov 19 14:32:10 2007 steveBureaucracySAFETYgrad student safety trainingJohn Miller and Alberto Stochino has received
the 40m safety bible.
 They still have to read the laser operation
  
  116   Tue Nov 20 10:11:33 2007 JohnSummaryPSLPMC pole measurementsWe measured the PMC pole in the following
way.
 FittedPMCPeak.jpg 
  117   Tue Nov 20 11:10:07 2007 tobinUpdateComputersepics access from matlabI installed "[url=http://www.slac.stanford.edu/~strauman/labca/]labca[/url]",
which allows [b]direct access to EPICS channels
from within Matlab[/b].  It comes with both
  
  118   Tue Nov 20 13:06:57 2007 tobinConfigurationComputerslinux1 has new diskAlex put the new hard disk into linux1 along
with a fresh install of linux (CentOS). 
The old disk was too damaged to copy.
  
  119   Tue Nov 20 18:02:54 2007 JohnSummaryComputersPSL_Main screenI've updated the PSL_MAIN screen. The old
version may be found in cvs/cds/caltech/medm/old/medm/psl.
 PSL_Screen.tif 
  120   Tue Nov 20 18:35:20 2007 JohnHowToComputersMatLab in EmacsIf you can't get MatLab to run in emacs try
adding the following to the .emacs file
  
  121   Wed Nov 21 14:31:41 2007 robUpdatePSLFSS twiddle
I `tweaked' the FSS path today.  Here's what
I did:
  
  122   Mon Nov 26 10:17:31 2007 steveOmnistructureSUSetmy sus damping restored20 days plot is showing etmy loosing damping
4 times.
I zoomed in with each event. Three of them
 etmyrms20d.jpgetmyrmseq.jpg 
  124   Tue Nov 27 15:45:08 2007 robConfigurationPSLFSS loop
It's unclear (to me, at least) what was the
end result of the FSS path tweaking before
 FSSsmall.jpg 
  125   Tue Nov 27 15:47:17 2007 robConfigurationIOOMC loopAfter the FSS running pretty quick, I checked
the MC loop.  I used TPA 1&2.
 MCsmall.jpg 
  126   Tue Nov 27 16:18:58 2007 robConfigurationIOOMC loopReduced the common gain to 22dB in the [COLOR=blue]mcup[/COLOR]
script, so that the WFS would not blow the
lock.  The above measure of the OLG was done
  
  127   Tue Nov 27 20:47:00 2007 tobinUpdatePSLFSSRana, Tobin

We looked at the RF PD signal to the FSS
 fss-tf0001.pdf 
  128   Wed Nov 28 04:21:46 2007 ranaUpdatePSLFSS[quote]Rana, Tobin
[SIZE=1]
We looked at the RF PD signal to the FSS
  
  129   Wed Nov 28 08:47:29 2007 steveOmnistructureVACrga is out of orderThe rga is not working since Nov 10
The controller is broken.
pd65-m-d23
 pd65d23.jpg 
  130   Wed Nov 28 12:43:53 2007 AndreyBureaucracy Here was the PDF-file of my presentation
I was  making a report with powerpoint presentation
during that Wednesday's 40-m meeting.
  
  131   Wed Nov 28 16:18:15 2007 AlbertoMetaphysicsEnvironmentso clean you can eat on itI tidied up the desks in the lab, brought
the Spectrum Analyzers back to the Salumeria
(you don't want to know about that), sorted
 DSC_0180.JPGDSC_0181.JPG 
  132   Wed Nov 28 16:46:28 2007 ranaConfigurationComputersscientific linux 5.0I tried installing Scientific Linux on Tiramisu.
The installation process was so bad (really)
that I quit after 15 minutes. Its back to
  
  133   Wed Nov 28 17:15:26 2007 ranaConfigurationSUSETMY damping / watchdogsSteve has noted that ETMY was often tripping
its watchdog. I saw this again today.
  
  134   Wed Nov 28 17:41:34 2007 robUpdatePSLFSS againI investigated the FSS a bit more today. 
I looked at the signals coming out of the
FSS frequency reference, and saw that both
  
  135   Wed Nov 28 19:02:41 2007 AndreyBureaucracyWIKI-40M UpdateNew WIKI-40M page describing Matlab Suspension Modeling
I created the WIKI-40m page with some details
about my today's talk on the 40-m lab meeting.
  
  136   Wed Nov 28 19:44:18 2007 tobinUpdatePSLHEPAI found the HEPA turned off completely.  I
turned it on.
  
  137   Wed Nov 28 21:51:52 2007 tobinConfigurationPSLISSI replaced the front-end differential receivers
for the ISS's "inner-loop" sensor and monitor
diode inputs with lower-noise [url=http://focus.ti.com/docs/prod/folders/print/ths4131.html]THS4131[/url]'s
  
  138   Thu Nov 29 10:36:47 2007 albertoConfigurationComputer Scripts / ProgramsAgilent 82357B GPIB to USB Interface Installation ProcedeureTo run the Agilent Automation-Ready CD provided
with the interface is only the first step
of the installation. Apparently there should
  
  139   Thu Nov 29 11:10:54 2007 robOmnistructureVACRGAlogger sleepingWithout the RGA controller responding, the
RGAlogger script just hangs.  Rather than
fix it, I just put it to sleep by commenting
  
  140   Thu Nov 29 14:29:22 2007 tobinConfigurationComputerslinux1 httpd/conlogger fixedI think I fixed the [url=http://linux1/cgi-bin/conlog_web.pl]conlogger
web interface on linux1[/url].
  
  141   Thu Nov 29 15:17:53 2007 robConfigurationPSLISS
I put some ISS beam on the diode on the PSL
table.  In the previous layout, this was
  
  142   Thu Nov 29 18:10:13 2007 AlbertoHowToComputer Scripts / ProgramsGPIB ScriptsI've spent a lot of time trying to configurate
the GPIB-USB interface for the HP4195. After
installing 1) the Agilent libraries, 2) the
  
  143   Thu Nov 29 19:35:14 2007 ranaHowToComputer Scripts / ProgramsGPIB Scripts[quote]I've spent a lot of time trying to
configurate the GPIB-USB interface for the
HP4195. After installing 1) the Agilent libraries,
  
  144   Fri Nov 30 11:22:22 2007 ajwSummaryCDSGEO DV => LIGO DV[quote][URL=http://www.aei.mpg.de/~hewitson/]Martin
Hewitson[/URL] of [B]GEO600[/B] fame has
modified the cool GEO DV
  
  145   Fri Nov 30 11:44:57 2007 robConfigurationElectronicsETMX oplevIn the interests of getting the Xarm alignment
script working again, I reset the local damping
gains for the test masses to their previous
  
  146   Fri Nov 30 13:46:50 2007 robConfigurationElectronicsETMX oplev dead again[quote]In the interests of getting the Xarm
alignment script working again, I reset the
local damping gains for the test masses to
  
  147   Fri Nov 30 19:11:05 2007 ranaConfigurationElectronicsETMX oplev dead againI removed the ETMX HeNe and put in on a test
table and it fired up fine. In its
previous location the light on the HeNe power
  
  148   Fri Nov 30 19:29:14 2007 ranaConfigurationSUSnew screenAndrey is working on a new screen to show
us the drift of the optics by alarming on
their osem values. [COLOR=darkred]You can
  
  149   Fri Nov 30 19:46:58 2007 ranaConfigurationComputersEPICS Time Bad againThe time on the EPICS screens is off by 10
minutes again. Por Que?
  
  150   Fri Nov 30 20:13:57 2007 dmassSummaryGeneralHeNe UniPhase LaserData for the Uniphase 1.9 mW HeNe laser (labeled:
"051507 From ISCT-BS") SN: 1284131 Model:
1103P
 Matlabcode.zipUniPhaseWaist.jpg 
  151   Fri Nov 30 20:17:26 2007 AndreyConfigurationPEMAccelerometers and alum.plates for themAll 6 accelerometers which were located near
the ITMX are turned off and disconnected
from the power cords.
 Scheme_Aluminum_Piece-inches.pdf 
  152   Fri Nov 30 21:27:24 2007 ranaDAQPEMweather / stacis / c1pem1I was trying to add some Seis BLRMS channels
to the c1pem1 processor so that we could
have DMT trends.
  
  153   Sun Dec 2 17:37:33 2007 ranaOmnistructureComputersNetwork Cabling in the OfficeWe all know that we've spent many integrated
man hours trying to figure out why our network
connections
  
ELOG V3.1.3-