40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 3 of 339  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
ID Date Author Type Categoryup Subject Text Attachments
  8111   Tue Feb 19 17:14:56 2013 ChloeUpdate QPD CircuitI finished working out the circuit and
figured out where the broken connections
were. This is diagrammed in my notebook (will
  
  8137   Fri Feb 22 13:03:49 2013 ManasaUpdate MC REFL PD murder 
[Yuta, Manasa]
We turned IFO power back to 1.25W
 dead.jpg 
  8139   Fri Feb 22 17:33:38 2013 ChloeUpdate QPD circuit diagramToday I tested the circuitry within the
QPD to make sure I had put it back together
correctly. The output was able to detect
 IMG_0377.JPG 
  8173   Tue Feb 26 17:36:28 2013 ChloeUpdate QPD CircuitI corrected the circuit diagram I constructed
last time - it would read 0 output most of
the time because I made a mistake with the
  
  8185   Wed Feb 27 14:59:01 2013 EvanUpdate Altered MC demodulation phase I took out a short (~12 cm) SMA cable
from the "LO input" path into the
MC demod board in an attempt to maximize
 Q_and_I_before.epsQ_and_I_after.eps 
  8186   Wed Feb 27 17:43:54 2013 RijuUpdate Photodiode transimpedanceHere is the transimpedance for the other
PD used for MC REFL
 TFnewreflpd.pdfNewREFL_z.pdf 
  8187   Wed Feb 27 18:01:46 2013 KojiUpdate Photodiode transimpedanceHow
much is the exact resonant frequency?
And 
  
  8188   Wed Feb 27 18:17:05 2013 RijuUpdate Photodiode transimpedance

    

       
            
  
  8189   Wed Feb 27 18:38:51 2013 RijuUpdate Photodiode transimpedance

    

       
            
  
  8233   Tue Mar 5 17:23:06 2013 ChloeUpdate QPD Adding/Subtracting CircuitToday I finished building the adding/subtracting
circuit for the QPD and tested that the QPD
could see a laser moving across its visual
  
  8295   Thu Mar 14 16:56:16 2013 ChloeUpdate QPD Circuit DesignI have sketched out the circuit design
for the QPD. However, it seems like even
when using a different opamp configuration,
  
  8338   Mon Mar 25 16:51:43 2013 ChloeUpdate Final QPD Circuit DesignThis is the final version of the QPD circuit
I'm going to build. After playing around
with the spatial arrangement, this should
 IMG-20130325-00244.jpg 
  8346   Mon Mar 25 23:27:26 2013 ChloeUpdate QPD CircuitIn order to test the mount vibrations,
I will likely try and make a different circuit
work (with the summing/subtracting on an
  
  8358   Tue Mar 26 17:32:30 2013 ChloeUpdate QPD/ECDL ProgressI built the summing/subtracting circuit
on the breadboard, and hooked this up with
one of the other QPDs I found (image of setup
 IMG-20130326-00245.jpg 
  8381   Mon Apr 1 16:13:50 2013 ChloeUpdate QPDBecause we would like to get started on
testing mount vibrations as soon as possible,
I've been trying to get one of the other
  
  8403   Wed Apr 3 16:03:59 2013 ChloeUpdate QPD Voltage RegulatorsThe voltage regulator on the QPD breadboard
seems to be having problems... yesterday
Eric helped me debug my circuit and discovered
  
  8406   Wed Apr 3 18:27:03 2013 KojiUpdate QPD Voltage RegulatorsBreadboards may not be suitable for a reliable
work. Why don't you switch to any protoboard
and real soldering?
  
  8478   Tue Apr 23 16:31:13 2013 EricConfiguration PD frequency response[Eric, Riju]
Summary: Routing Fibers on AP table
for Photo Diode Frequency Response Measurement
  
  8484   Wed Apr 24 14:24:40 2013 RijuUpdate PD frequency response Here I am attaching the first schematic
diagram of the PD frequency response set-up,
I will keep updating it with relevant informations
 PD_freq_resp.pdf 
  8492   Thu Apr 25 17:56:28 2013 RijuConfiguration PD frequency response [Eric, Riju]
Today we have routed the fibers from
1x16 fiber splitter to POX table for POX11
 IMG_0495.JPG 
  8493   Thu Apr 25 18:58:06 2013 KojiConfiguration PD frequency responseNo.... what I told was to put the roll
next
to the splitter, 
  
  8497   Fri Apr 26 17:08:42 2013 RijuConfiguration PD frequency response

    

       
            
  
  8511   Tue Apr 30 12:25:23 2013 ChloeUpdate QPDAnnalisa and I met yesterday and fixed
the voltage regulator on the breadboard so
the QPD circuit is working. We will meet
  
  8532   Tue May 7 03:08:12 2013 JenneUpdate PRM yaw responsible for RINKoji spent some time earlier this evening
exploring where the excess RIN that we see
in the PRC is coming from. 
 BS_excited.pdfITMX_excited.pdfITMY_excited.pdfPRM_excited.pdf 
  8604   Tue May 21 14:50:52 2013 Max HortonUpdate Importing New CodeThere was an issue with running the new
summary pages, because laldetchar was not
included (the website I used for instructions
  
  8678   Wed Jun 5 14:39:41 2013 Max HortonUpdate Importing New CodeMost dependencies are met.  The next
issue is that matplotlib.basemap is not installed,
because it is not available for our version
  
  8762   Thu Jun 27 05:44:51 2013 ranaUpdate 40MARS wireless network problems

    

       
            
  
  8782   Fri Jun 28 11:33:32 2013 SteveUpdate 40MARS wireless network problem

    

       
            
  
  8795   Wed Jul 3 11:07:17 2013 AlexSummary Photodetector Characterization [Alex, Koji]
We characterized Koji's BBPD
MOD for REFL165 (see attachment).
 BBPD_PCB.pdftransimpedance_measurement.pdf 
  8806   Mon Jul 8 16:27:49 2013 AlexUpdate Planned rack additionsAlex and Eric
For the photodetector frequency response
automation project, we plan to add modules
 Annotated_Rack_1y1.pdf 
  8829   Thu Jul 11 12:00:50 2013 AlexUpdate Planned rack additions[Eric, Alex]
We mounted our Laser Module and Laser
Power Source in rack 1y1. We plan to add
 Annotated_Rack_1y1_-_update.pdf 
  8832   Thu Jul 11 23:50:57 2013 gautamConfiguration PZT Driver Board-changes made Summary:

 ASC_schematic.pdfDAC_Max_output.JPG 
  8850   Mon Jul 15 16:51:37 2013 AlexConfiguration Planned AS Table addition [Eric, Alex]
We are planning to add our reference
PD to the southern third of the AS Table
 AS_Table_Ref_PD_Addition.pdf 
  8855   Tue Jul 16 10:16:23 2013 KojiUpdate Beatbox XARM whitening modifiedThe
X arm whitening filters of the beatbox were
modified.
 Beatbox_mod.pdfALS_whitening.pdfBeatbox_input_dependence.pdf 
  9368   Tue Nov 12 21:50:01 2013 ranaUpdate zita network configured 
 I installed 'nfs-client' on
zita (the StripTool terminal). It now has
  
  10657   Fri Oct 31 11:46:15 2014 manasaUpdate Rattling HEPA : Eventually stopsThe PSL HEPA stopped
working while it was running
  
  11392   Tue Jul 7 17:22:16 2015 JessicaSummary Time Delay in ALS CablesI measured the transfer functions in the
delay line cables, and then calculated the
time delay from that.
 cableA_fit.jpgcableA_resid.jpgcableB_fit.jpgcableB_resid.jpg 
  12352   Fri Jul 29 03:44:04 2016 AakashSummary About Acromag | SURF 2016I tried to recompile the modbusApp binary
for linux-arm acrhitecture since I suspected
someting wrong with it. But still the problem
  
  12825   Mon Feb 13 17:19:41 2017 yinziConfiguration configuring ethernet for raspberry piGautam and I were able to get the Raspberry
Pi up and running today, including being
able to ssh into it from the control room.
 Screen_Shot_2017-02-13_at_5.11.52_PM.png 
  12949   Fri Apr 21 13:59:47 2017 Eric GustafsonSummary 1064 nm Semiconductor Laser Fiber Distribution System and Mirror Tomography1064 nm Semiconductor Laser Fiber
Distribution System and Mirror Tomography

Below threshold these Semiconductor
  
  13686   Mon Mar 19 07:37:00 2018 Angelina PanSummary Proposed QPD Optical ArrangementI am currently working on an optical arrangement
consisting of a QPD that measures the fluctuations
of an incoming HeNe laser beam that
 angelinaCode.py.tar.bz2 
  13699   Thu Mar 22 17:47:16 2018 Angelina PanSummary Proposed QPD Optical Arrangement   IMG_0869.jpg 
  13915   Mon Jun 4 19:41:01 2018 keerthanaUpdate Finesse code for cavity scanThe cavity scan data obtained from the
Finesse simulation is attached here. Fig1
indicates the cavity scan data in the absence
 Fig1.pngFig2.png 
  13928   Thu Jun 7 20:19:53 2018 poojaUpdate  Just to inform, I'm working in optimus
to develop python code to train the neural
network since it requires a lot of memory.
  
  13956   Wed Jun 13 18:08:36 2018 keerthanaUpdate Finesse code for cavity scanThe unit mentioned in the x-axis was wrong.
So I have remade the graphs. The point where
frequency equals to zero is actually the
 finesse1.pdffinesse2.pdf 
  13994   Thu Jun 21 09:33:02 2018 JonUpdate AUX Mode Scans of YARM, PRC cavities[Jon, Keerthana, Sandrina]

Yesterday we carried out preliminary
proof-of-concept measurements using
 YARM_AUX_RF-offset_scan.pdftemp_broadband_refl33.pdf 
  14005   Fri Jun 22 10:42:52 2018 poojaUpdate Developing neural networksAim: To find a model that trains the simulated
data of Gaussian beam spot moving in a vertical
direction by the application of a sinusoidal
 NN_fig.zip 
  14045   Sun Jul 8 22:27:25 2018 keerthanaUpdate AUX diagram(Analisa, Keerthana, Sandrine)

So far we tried four different
techniques to scan the AUX laser. They are,
 PLL-single_demodulation.pdfPLL-double_demodulation.pdf 
  14058   Thu Jul 12 15:15:47 2018 SandrineUpdate Beat Note Measurements for Cavity Scans(Gautam, Sandrine)

We calculated the expected power
of the beat note for Annalisa's Y arm
  
  14111   Sat Jul 28 22:16:49 2018 John MartynUpdate Characterization of Transimpedance AmplifierKevin and I meaured the transfer function
of the photodiode circuit using the Jenne
laser and agilent in the 40m lab. The attached
 PD_TF1.pdfPD_TF2.pdfPD_and_TIA_Transfer_Function_Measurements.zip 
ELOG V3.1.3-