40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 34 of 337  Not logged in ELOG logo
IDup Date Author Type Category Subject Text Attachments
  1665   Wed Jun 10 09:06:12 2009 steveUpdatePEMparticle counts and turbulanceI moved the mobile HEPA filter from ITMX's
north door to ITMX-ISCT and covered it up
with a merostate tent to accommodate the
 parturbulnc.jpg 
  1666   Wed Jun 10 09:28:14 2009 steveUpdatePSLPMCThe PMC alarm was on this morning. It was
relocked at lower HV
The FSS_RMTEMP jumped 0.5 C so The
 pmctemphv.jpg 
  1667   Thu Jun 11 03:15:15 2009 AlbertoUpdateLSCDD Handoff attemptsPete, Alberto,
tonight we worked on the tuning of
the double demod phases for the handoff of
  
  1668   Thu Jun 11 14:54:18 2009 josephb, albertoUpdateComputersWireless networkAfter poking around for a few minutes several
facts became clear:
1) At least one GPIB interface has
  
  1669   Thu Jun 11 22:14:10 2009 AlbertoUpdateLSCDD Handoff for the Short DOFs completedThis afternoon I tuned the handoff script
for the SRC, after that Rob eralier during
the day had already adjusted that for PRC.
  
  1670   Fri Jun 12 02:01:03 2009 robUpdateComputer Scripts / ProgramsDRM matrix diagonalizationI started two scripts, senseDRM
and loadDRMImatrixData.m, which Peter
will bang on until they're correct. 
  
  1671   Fri Jun 12 09:56:38 2009 steveConfigurationVACnew maglev installedJoe and Steve
 
The retrofitted Osaka 390 was installed
 m390pd.jpg 
  1672   Fri Jun 12 15:34:49 2009 steveConfigurationVACmaglev is running


   
        
            
  
  1673   Mon Jun 15 15:17:33 2009 josephb, SteveConfigurationVACVacuum control and monitor screensWe updated the vacuum control and monitor
screens  (C0VAC_MONITOR.adl and C0VAC_CONTROL.adl). 
We also updated the /cvs/cds/caltech/target/c1vac1/Vac.db
  
  1674   Mon Jun 15 16:31:36 2009 steveConfigurationVACRGA is scanning new Maglev


   
        
            
  
  1675   Tue Jun 16 02:09:31 2009 robUpdateLockingDD handoff finally workingI had trouble getting the SRC handoff from
SD to DD to work.  I tried different
gains, flipping the PD7 & 8 demod phases
  
  1676   Tue Jun 16 03:43:04 2009 robUpdateLockingsame troublesLock is still being lost, right at the
end of the process when trying to reduce
the CARM offset to zero.
  
  1677   Tue Jun 16 09:02:30 2009 steveConfigurationVACnew maglev RGA scanThe maglev fore line pressure is 3e-6 torr
at CC2 after 4 days of pumping. Varian turbo
V-70 is pumping on it through V4 and VM2
 nmagd4scan.jpgnmagd4.jpg 
  1678   Tue Jun 16 14:02:16 2009 robUpdateLockinglockedThe IFO is locked, at the operating point
(zero CARM offset).  The problem with
reducing the residual CARM offset in the
  
  1679   Tue Jun 16 16:10:01 2009 peteUpdateLockinginput matrix experimentsLast night Rob ran senseDRM and loadDRMImatrixData
and came up with the following for the input
matrix:
  
  1680   Tue Jun 16 17:38:35 2009 robUpdateLockingDeWhites ONWith the common mode servo bandwidth above
30kHz and the BOOST on (1), I was able to
switch on the test mass dewhitening. 
  
  1681   Tue Jun 16 20:03:41 2009 AlbertoUpdateElectronicsRequirements on Wenzel MultiplierFor
the 40m Upgrade, we plan to 
 SummaryOfResult.pdf 
  1682   Wed Jun 17 01:07:50 2009 robConfigurationComputersmatapps on /cvs/cdsI checked out a copy of matapps into /cvs/cds/caltech/apps/lscsoft
so that I could find the matlab function
strassign.m, which is necessary for some
  
  1683   Wed Jun 17 01:09:47 2009 robUpdateComputers/cvs/cds 91% fullIn /cvs/cds/caltech
 
  
  1684   Thu Jun 18 23:08:46 2009 robUpdateLockingspectrumHere's a noise spectrum of the RSE interferometer,
in anti-spring mode, with RF readout. 
I'd say the calibration is "loose."
 DARMnoise_929352240.pngDARMnoise_929352240.pdf 
  1685   Thu Jun 18 23:20:40 2009 robSummaryLSCI-Q ratio with RF detected DARMThis is a ratio of PD1_I to PD1_Q (so a
ratio of the two quadratures of AS166), measured
in an anti-spring state.  It's not flat
 IQratio.jpg 
  1686   Fri Jun 19 13:38:42 2009 AlbertoConfigurationComputerselog rebootedToday I found the elog down, so I rebooted
it following the instructions in the wiki.
  
  1687   Fri Jun 19 13:39:29 2009 AidanUpdateGeneralUpper limit measurement of the scatter from the eLIGO beam dumps. 
 D0900095_ELIGO_35_WATT_AIR_COOLED_BEAM_DUMP_3INCH_P.POL-3.PDFbeam_dump_expt.pngscatter_measurement1.pdfBRDF1.pdfIMG_0308.JPG 
  1688   Fri Jun 19 14:30:47 2009 AlbertoConfigurationComputerselog rebooted


   
        
            
  
  1689   Sun Jun 21 00:08:26 2009 ranaConfigurationComputerselog rebooted 
nodus:log>dmesg
  
  1690   Tue Jun 23 10:06:03 2009 steveUpdateVACnew maglev RGA scan at day6The Maglev is running for 10 days with
V1 closed.  The pressure at the RGA-region
is  at 2e-9 torr on CC4 cold cathode
 newmagscand6.jpgnmagpresd10.jpg 
  1691   Tue Jun 23 15:19:42 2009 steveConfigurationVACV1 is open


   
        
            
 V1_opennmag.jpg 
  1692   Tue Jun 23 23:14:36 2009 ClaraConfigurationPEMAccelerometers relocatedBoth accelerometers have been moved in
an attempt to optimize their positions. The
MC1 accelerometer was moved from one green
  
  1693   Wed Jun 24 09:21:19 2009 steveConfigurationVACIFO RGA scan with Maglev & Cryo


   
        
            
 nmagd1ifo.jpgnmagCryopres.jpg 
  1694   Wed Jun 24 10:53:34 2009 Chris ZimmermanUpdateGeneralWeek 1/2 UpdateI've spent most of the last week doing
background reading; fourier transforms, shm,
e&m, and other physics that I didn't
  
  1695   Wed Jun 24 11:20:40 2009 StephanieUpdateGeneralMultiply Resonant EOM UpdateI have created the attached EOM circuit
with resonances at 11 MHz, 29.5 MHz, and
55 MHz (the magnitude and phase of the voltage
 EOM_CktDiagram.JPGEOM_VoltagePlot.JPG 
  1696   Wed Jun 24 12:04:00 2009 ClaraUpdatePEMaccelerometer clarificationWhen I said "MC1/MC2 accelerometers,"
I meant the entire three-axis accelerometer
set at each point.
  
  1697   Wed Jun 24 12:04:22 2009 ZachUpdateCamerasSURF entryThis week, I've been reading some literature
concerning PLL and familiarizing myself with
LINUX, MATLAB, and high-pass filter circuits. 
  
  1698   Wed Jun 24 12:09:24 2009 ClaraUpdatePEMWeek 1(ish)I spent the week reading up on filter algorithm
theory, particularly Wiener filtering. I
have also learned how to get data from specific
  
  1699   Wed Jun 24 14:43:19 2009 robUpdateComputerstdsresp on linux => pzresp 
tdsresp is broken on our linux control
room machines.  I made a little perl
  
  1700   Wed Jun 24 17:08:16 2009 steveBureaucracySAFETYsurf student safetyThe 40m lab specific safety training is
done. The participants were
Stephanie Erickson, Clara Bennett,
  
  1701   Thu Jun 25 10:28:58 2009 steveHowToVACCryopump is regeneratedThe Cryopump's VC1 valve to IFO was closed
yesterday.
The compressor 
Helium pressure was 235 PSI. The cold head
 Creg.jpg 
  1702   Thu Jun 25 17:27:42 2009 ranaUpdateComputerstdsresp on linux I downloaded the tdsresp.pl from LLO and put
it into the various TDS/bin paths. Also updated
the LLO specific path stuff. It runs.
  
  1703   Thu Jun 25 21:00:30 2009 ClaraUpdatePEMMC1 Accelerator set moved again; new XLR cablesI moved the MC1 set of accelerators. Might
have bumped things. If things aren't working,
look around the MC1 chamber.
  
  1704   Fri Jun 26 15:22:28 2009 ClaraUpdatePEMXLR cables tested and labeledWe now have two 80-foot, female-to-female
XLR cables for our pretty new microphones,
one yellow and one purple. They have been
 NC3FXX-EMC.pdfCat11_p35.pdf 
  1705   Fri Jun 26 18:00:36 2009 JenneUpdatePEMNew PEM channels for the fancy-pants new microphones[ Jenne, Clara ]
We made new channels for the microphones
which came in this week, by editing C1ADCU_PEM.ini
  
  1706   Fri Jun 26 19:14:04 2009 ranaUpdateEnvironmentseisBLRMS for the past 3 weeks[COLOR=chocolate][SIZE=2]Restarted the seisBLRMS.m
on mafalda (running a term on op540m). Don't
know why it stopped - the
  
  1707   Sat Jun 27 02:48:09 2009 ClaraUpdatePEMI moved accelerometers and made some pretty picturesI have been working on finding the best
spots to put the accelerometer sets in order
to best subtract out noise (seismometers
 6x 
  1708   Sat Jun 27 03:16:16 2009 ClaraUpdatePEMExciting microphone things!So, I'm double-posting, but I figured the
last post was long enough as it was, and
this is about something different. After
 mic_voltage_out.pngvoltage_dividers.pngvoltage_divider_sketch.png 
  1709   Tue Jun 30 23:09:40 2009 AlbertoUpdateLockingchronicles of some locking attemptsTonight I tried to lock the interferometer.
At the first attempts the arm power didn't
go above about 4. The mode cleaner seemed
  
  1710   Wed Jul 1 10:56:42 2009 Chris ZimmermanUpdateGeneralWeek 2/3 UpdateI spent the last week working a lot with
the differences between a basic Michelson
readout and the new one as a displacement
  
  1711   Wed Jul 1 11:00:52 2009 StephanieUpdateGeneralMultiply Resonant EOM UpdateSince last week, I have come up with a
new circuit, which is shown in the attached
figure. The magnitude (solid) and phase (dashed)
 EOMCKT.pngPR1_VoltagePlot.pdf 
  1712   Wed Jul 1 11:04:27 2009 ZachUpdateCamerasGigE Phase CameraThis past week, I have building a sine
wave rectifier and trying to write a simple
program that displays a ccd image to familiarize
 trigger.jpgfig1b.pdf 
  1713   Thu Jul 2 05:27:12 2009 ClaraUpdatePEMVoltage Divider OopsI tested the voltage dividers and was getting
up to about 3V. I retested the mic w/o the
voltage divider in place, and, lo and behold,
 voltage_divider_diagram.png 
  1714   Thu Jul 2 06:31:35 2009 ClaraUpdatePEMFirst mic in place and connectedI clamped Bonnie (microphone) to the top
of a chamber near the vertex of the arms
and placed Clyde (pre-amp) on the table right
 bonnieandclyde.JPG 
ELOG V3.1.3-