40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 340 of 344  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  6863   Sun Jun 24 23:42:31 2012 yutaUpdateComputer Scripts / ProgramsPMC lockerI made a python script for relocking PMC.
It currently lives in /opt/rtcds/caltech/c1/scripts/PSL/PMC/PMClocker.py.
  
  6868   Mon Jun 25 15:07:49 2012 yutaUpdateIOOMC beam spot trendI adjusted MC WFS offsets using /opt/rtcds/caltech/c1/scripts/MC/WFS/WFS_FilterBank_offsets.
Beam spot positions on MC mirrors
 MCdecenter.png 
  6871   Mon Jun 25 17:48:27 2012 yutaUpdateComputer Scripts / Programsscript for finding IR resonance using ALSI made a python script for finding IR resonance
using ALS. It currently lives in /opt/rtcds/caltech/c1/scripts/ALS/findIRresonance.py.
 findIRresonance20120625.png 
  6873   Tue Jun 26 00:52:18 2012 yutaUpdateComputer Scripts / ProgramsPMC locker

    

       
            
  
  6874   Tue Jun 26 01:30:13 2012 yutaSummaryGreen Lockingsimultaneous hold and release of the arm (aka two arm ALS)To get the feeling of the master of IFO,
I;
 ALSboth20120625_2withAS.png 
  6875   Tue Jun 26 22:37:43 2012 yutaUpdateIOOenergized OMC stages[Koji, Yuta]

We checked that PZTs between SRM and
  
  6876   Wed Jun 27 03:43:52 2012 yutaSummaryIOOhow to improve mode matching to armsFrom the mode scan measurements of the
arms(elog #6859),
~6% of mode-mismatch comes from 2nd-order
 modematchMCtoARM_design.pngmodematchMCtoARM_MMT1MMT2longer.png 
  6884   Wed Jun 27 16:23:12 2012 yutaUpdateIOOAS and REFL on AP table alignedI touched steering mirrors for AS and REFL
at AP table.
AS beam and REFL beam now hits cameras
  
  6885   Wed Jun 27 23:54:21 2012 yutaUpdateComputer Scripts / Programsimage capturing scriptMike J. came tonight and he fixed Sensoray
(elog #6645).
He recompiled it and fixed it.
 AS_1024901004.bmp 
  6886   Thu Jun 28 00:50:48 2012 yutaUpdateLockingPRMI work started, commissioning planMy goal for tonight was to lock PRMI,
 grasp the current situation
by my eye,
 POP_1024903948.bmpREFL_1024903929.bmpAS_1024903921.bmp 
  6889   Thu Jun 28 20:59:28 2012 yutaBureaucracyLockingvent for PRC check, TOMORROW!Koji, Jamie and I talked together and I decided to VENT TOMORROW   
  6891   Fri Jun 29 01:49:36 2012 yutaBureaucracyLockingvent for PRC check, TOMORROW!

    

       
            
  
  6892   Fri Jun 29 02:17:40 2012 yutaUpdateIOOprep for the vent - beam attenuating[Koji, Jamie, Yuta]

We attenuated the incident beam (1.2
  
  6893   Fri Jun 29 03:21:32 2012 yutaUpdateGeneralprep for the vent - others1. Turned off high voltage power supplies
for PZT1/2 (input PZTs) and OMC stage 1/2.
They live in 1Y3 rack and AUX_OMC_NORTH rack.
 MEDMscreenshotswithCOW_20120629.png 
  6896   Fri Jun 29 16:41:41 2012 yutaUpdateGeneralPRM was NOT installed backwards[Koji, Steve, Jamie, Yuta]

So, PRM was NOT flipped......
  
  6899   Sun Jul 1 13:20:09 2012 yutaUpdateIOOMC in low powerI modified autolocker for MC in low power
mode (/opt/rtcds/caltech/c1/scripts/MC/autolockMCmain40m_low_power)
to make it work with the current directory
  
  6900   Sun Jul 1 23:48:15 2012 yutaSummaryGeneralclipping at BS, my plan[Koji, Yuta]

We aligned PRMI and inspected BS chamber.
 PR3.JPGPRM.JPG 
  6903   Mon Jul 2 18:27:25 2012 yutaUpdateGeneralBS and ITMX chambers closed[Koji, Steve, Jamie, Jenne, Yuta]

We opened BS and ITMX chambers, took
  
  6910   Tue Jul 3 20:51:06 2012 yutaUpdateIOOMC in vacuum is backMC came back to the state as it was before
the vent.
 ALL_1025408289.bmp 
  6913   Wed Jul 4 20:13:46 2012 yutaBureaucracyLockingPRC commissioning planIssues in PRC:
  1. Power recycling gain is
too low (~ 15 instead of 40, according to
  
  6914   Wed Jul 4 21:11:53 2012 yutaUpdateLockingFPMI in vacuum is backI aligned FPMI and greens. There's no recognizable
difference between before and after the vent.
 ALL_1025495266.pngMEDMscreenshotswithCOW_20120704.png 
  6915   Thu Jul 5 01:20:58 2012 yutaSummaryCDSslow computers, 0x4000 for all DAQ statusALS looks OK. I tried to lock FPMI using
ALS, but I feel like I need 6 hands to do
it with current ALS stability. Now I have
  
  6916   Thu Jul 5 01:34:11 2012 yutaUpdateLockingMI with X arm ALSI tried to lock FPMI using ALS, but I could
not take care of ALS for both arms + MI.
So, I decided to try one arm + MI.
  
  6922   Thu Jul 5 13:38:05 2012 yutaSummaryLockingcavity g-factor from mode scanCavity
g-factor for X arm is 0.3737 +/- 0.002, Y
arm is 0.3765 +/- 0.003.
  
  6925   Fri Jul 6 01:39:56 2012 yutaUpdateLockingMI + Y arm ALS succeed, but not bothMI with X arm length stabilized off resonance
and Y arm length stabilized at resonance
using ALS succeed, but I couldn't bring X
 FPMIALStrial20120706.pngnewALSMEDMscreen.png 
  6926   Fri Jul 6 02:46:03 2012 yutaUpdateLockingY arm ALS handing off to LSCHanding off the servo from ALS to LSC for
one arm is quite easy because servo filters
are pretty much same for ALS and LSC. I demonstrated
 handofftoLSC20120706.png 
  6931   Fri Jul 6 14:10:31 2012 yutaSummaryLSCcalculation of FPMI using ALSFrom calculation, phase fluctuation of
reflected beam from length stabilized arm
is not disturbing MI lock.
  
  6938   Sun Jul 8 00:27:54 2012 yutaSummaryLockingcalibrating phase tracking mode scan dataFSR
for X/Y arm are 3.97 +/- 0.03 MHz and 3.96
+/- 0.02 MHz respectively. This
  
  6940   Sun Jul 8 19:31:53 2012 yutaUpdateLockingcharacterizing LSC arm lock by ALS error signalRMS
of X/Y arm length using POX/POY lock is <160
pm and <120 pm respectively. 
 XarmLengthspectra20120708.pngLSCPOYarmIRlockOLTF.pngYarmLengthspectra20120708.pngLSCPOXarmIRlockOLTF.png 
  6941   Mon Jul 9 05:02:58 2012 yutaUpdateLockingadjusted ALS filters, current RMSI adjusted filters of ALS to give more
phase margin.
RMS
 ALSXarmLengthspectra20120708.pngALSXarmOLTF.pngALSYarmOLTF.pngALSYarmLengthspectra20120708.png 
  6942   Mon Jul 9 05:15:46 2012 yutaUpdateGreen Lockinglocked MI while ALS using ASDCI locked MI while both arm length are stabilized
at IR resonance. This could be done using
DC READOUT,
 FPMIALStrial20120709.png 
  6947   Mon Jul 9 23:18:09 2012 yutaUpdateLSCPRMI got more stable a bitI modified filiters for LSC_MICH and LSC_PRCL.
Although modes we can see at POP and
AS look still bad, error signals are less
 LSCMICHOLTF.pngLSCPRCLOLTF.pngALL_1025928219_PRMIlocked3.pngPRMIbeammotion20120709.png 
  6950   Tue Jul 10 03:16:17 2012 yutaUpdateLSCPRMI got more stable a bitI modified filiters for LSC_MICH and LSC_PRCL
again to cope with power recycling gain fluctuation.
After some more alignment, power recycling
 LSCMICHOLTF.pngLSCPRCLOLTF.pngPRMI20120709_2.png 
  6952   Tue Jul 10 17:47:55 2012 yutaUpdateSUSPRM oplevs fixedI centetered PRM oplev, lowered gain and
PRM oplev servo is not oscillating any more.
It is OK for more than a softball
 PRMoplevpitOLTF.pngPRMoplevyawOLTF.pngPRMOplevSpectra20120710.png 
  6953   Tue Jul 10 21:37:05 2012 yutaUpdateLSCPRMI glitch studyPRMI
glitch certainly comes from power recylcing
gain fluctuation.
 PRMIgilitch20120709.pngPRMIgilitch20120709_closer.png 
  6954   Wed Jul 11 02:25:11 2012 yutaUpdateLSCPRMI beam spot motion might be from PRM/BS motionMy hypothesis from the measurements below,
to explain PRMI beam spot motion is;
 POPDCASDC4.pngFeedback4.pngOLPITYAWandPOPDC4.pngOLPITYAWandPOPDCunlocked.png 
  6955   Wed Jul 11 03:53:41 2012 yutaUpdateLSCBS 3.3 Hz motion on MIIt is not as dramatic as PRMI, but I could
see BS 3.3 Hz motion at AS and REFL when
MI is locked at dark fringe.
 REFLDCASDCMIlocked.png 
  6960   Wed Jul 11 13:36:58 2012 yutaUpdateSUSOSEM and oplev spectra of opticsBelow is angular spectra of every suspended
core optics.
As you can see, there's a peak at
 OLPITYAW.pngSUSPITYAW.png 
  6964   Wed Jul 11 16:19:08 2012 yutaUpdateSUSoplev servo phiologyI heard that Steve did great work on oplev
in Feb 2012.
Here's summary what happened to oplev
  
  6965   Thu Jul 12 02:12:42 2012 yutaUpdateSUSBS 3.3 Hz motionI tried to reduce BS 3.3 Hz motion with
local damping. 3.3 Hz probably comes from
the stack, but I want to reduce this because
 BSdam.pngBSOLSUSresonantgain.png 
  6967   Thu Jul 12 13:27:16 2012 yutaUpdateSUSmeasured OLTFs of PRMI optics' SUSPOSI measured openloop transfer functions
of PRM/BS/ITMX/ITMY SUSPOS servo.
They look great. They all have ~50
 PRMSUSPOSOLTF.pngBSSUSPOSOLTF.pngITMXSUSPOSOLTF.pngITMYSUSPOSOLTF.png 
  6972   Thu Jul 12 23:15:34 2012 yutaUpdateLSCPRMI LSC is making PRM motion worseIt looks like PRMI LSC is making PRM motion (and
BS motion) at ~3Hz worse.
 PRMBSPRMIonoff.pngITMXITMYPRMIonoff.pngOplevPRMIonoff.png 
  6974   Fri Jul 13 15:49:38 2012 yutaBureaucracyGeneral40m Priority Action ItemsThese are all priority action items need
to be done before I come back (in mid-September).
  
  7994   Mon Feb 4 19:33:19 2013 yutaSummaryGeneralrough analysis of aligned PRM-PR2 mode scan[Jenne, Yuta]

We redid PRM-PR2 cavity scan because
 3peakdata.png 
  7997   Tue Feb 5 02:04:44 2013 yutaSummaryGeneralrough analysis of aligned PRM-PR2 mode scanI redid PRM-PR2 cavity scan using oscilloscope
to avoid anti-aliasing effect.
Measured 
 PRMPR2scan.png 
  8000   Tue Feb 5 10:09:08 2013 yutaSummaryGeneralrough analysis of aligned PRM-PR2 mode scanstdev of [0.764, 0.751] is 0.007, but what
we need is the error of the averaged number.
Statistical error of the averaged number
  
  8006   Tue Feb 5 19:32:47 2013 yutaSummaryGeneralPR2/PR3 flipping and PRC stabilityWe are considering of flipping PR2 and/or
PR3 to make PRMI stable because PR2/PR3 seems
to be convex.
 PRMI_PR2HR_PR3HR.pngPRMI_PR2AR_PR3HR.pngPRMI_PR2HR_PR3AR.pngPRMI_PR2AR_PR3AR.png 
  8012   Wed Feb 6 15:20:55 2013 yutaSummaryGeneralFWHM was wrongI have to blame Jamie for putting extra
2 randomly.
Measured PRM-PR2 cavity 
  
  8021   Thu Feb 7 10:35:35 2013 yutaUpdateGeneralStore optics in respective cabinetsI'm not the one who opened the ITMX table
yesterday, but thanks for reminding me.
I put POP DC oscilloscope and its
  
  8028   Thu Feb 7 19:25:22 2013 yutaUpdateCDSC1ALS filters reloadedFilters for C1ALS were all gone. So, I
copied /opt/rtcds/caltech/c1/chans/C1GCV.txt
and renamed it as 
  
ELOG V3.1.3-