40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 33 of 170  Not logged in ELOG logo
Entry  Wed Aug 3 15:35:19 2016, Aakash, Update, General, Acromag Setup | SURF2016 
    Reply  Wed Aug 3 16:34:59 2016, Lydia, Update, General, Acromag Setup | SURF2016 
Entry  Mon Jul 4 10:30:37 2016, ericq, Update, General, Preliminary vent plans 
    Reply  Tue Jul 5 17:14:02 2016, ericq, Update, General, Vent progress noOsemSide.JPGOSEMside.JPG
       Reply  Tue Jul 5 19:10:41 2016, rana, Update, General, Vent progress jumpEvent20151105.png
          Reply  Tue Jul 5 21:51:35 2016, ericq, Update, General, Vent progress 
             Reply  Tue Jul 5 23:38:42 2016, gautam, Update, General, Vent progress - ETMX SUS Coil driver electronics investigation image.jpeg
                Reply  Wed Jul 6 22:58:01 2016, gautam, Update, General, Vent progress - ETMX SUS Coil driver electronics investigation 
                   Reply  Thu Jul 7 00:25:07 2016, ericq, Update, General, Vent progress - ETMX SUS Coil driver electronics investigation 
                      Reply  Thu Jul 7 10:49:03 2016, gautam, Update, General, Vent progress - ETMX SUS Coil driver electronics investigation UL_glitchMon_Striptool.png
                         Reply  Fri Jul 8 11:35:45 2016, gautam, Update, General, Vent progress - ETMX SUS Coil driver electronics investigation coilGlitchMon.png
                            Reply  Fri Jul 8 11:48:09 2016, Koji, Update, General, Vent progress - ETMX SUS Coil driver electronics investigation 
                               Reply  Fri Jul 8 14:03:26 2016, ericq, Update, General, ETMX removed from suspension zoom.jpg
                                  Reply  Fri Jul 8 16:33:26 2016, ericq, Update, General, ETMX removed from suspension 
                                     Reply  Fri Jul 8 20:44:09 2016, Koji, Update, General, ETMX removed from suspension 6x
                                        Reply  Sun Jul 10 15:38:01 2016, ericq, Update, General, ETMX in guiderod/standoff gluing fixture 6x
                                           Reply  Tue Jul 12 16:08:00 2016, ericq, Update, General, ETMX ruby guided gluing 
                                              Reply  Wed Jul 13 21:13:51 2016, Koji, Update, General, ETMX guide rod gluing / ETMY Magnet gluing 13x
                                                 Reply  Thu Jul 14 22:29:57 2016, ericq , Update, General, ETMX guide rod gluing / ETMY Magnet gluing 
                                                    Reply  Fri Jul 15 16:23:51 2016, ericq , Update, General, Gluing setbacks IMG_2768.JPGIMG_2771.JPG
                                                       Reply  Tue Jul 19 16:39:29 2016, Lydia, Update, General, ETMX magnet gluing/guiderod excess glue removed P7190201.JPGP7190203.JPG
                                                          Reply  Wed Jul 20 13:58:55 2016, Steve, Update, SUS, SUS damping out of vac chamber ETMXrack.jpgfromETMX-satBox.jpgsusDampingSatboxCab.jpgsusDampingSatboxCabl.jpg
                                                          Reply  Thu Jul 21 17:01:59 2016, ericq, Update, General, ETMX magnet gluing/guiderod excess glue removed 
                                                             Reply  Fri Jul 22 23:03:23 2016, gautam, Update, General, ETMX suspension - progress IMG_2828.JPGIMG_2826.JPGIMG_2821.JPGIMG_2822.JPGIMG_2823.JPG
                                                                Reply  Sun Jul 24 03:43:56 2016, ericq, Update, General, Magnet positioning 
                                                                Reply  Mon Jul 25 13:01:49 2016, ericq, Update, General, ETMX suspension - progress IMG_2829.JPGIMG_2830.JPGIMG_2831.JPGIMG_2832.JPGIMG_2833.JPG
                                                                   Reply  Mon Jul 25 13:47:19 2016, rana, Update, General, ETMX suspension - progress 
                                                                   Reply  Mon Jul 25 17:01:54 2016, Steve, Update, SUS, ETMX suspension - progress ITMYside2011.JPG
                                                                   Reply  Mon Jul 25 20:37:46 2016, gautam, Update, General, ETMX suspension - Side OSEM test osem_test_2016_07_25.png
                                                                      Reply  Tue Jul 26 18:07:57 2016, gautam, Update, General, ETMX suspension - Further OSEM Tests OSEM_spectra.pdf
                                                                         Reply  Thu Jul 28 03:22:28 2016, ericq, Update, General, ETMX magnets re-reglued 
                                                                            Reply  Thu Jul 28 13:49:44 2016, gautam, Update, General, ETMX magnets re-reglued ETMX_sideMagnet.JPGETMX_sideMagnet_zoomed.JPG
                                                                               Reply  Thu Jul 28 17:48:17 2016, gautam, Update, General, ETMY LR magnet broke off 
                                                                                  Reply  Thu Jul 28 22:43:03 2016, rana, Update, General, ETMY UL magnet broke off 
                                                                                  Reply  Wed Aug 3 10:52:03 2016, Steve, Update, General, ETMY soaking dish SD1.jpgSD2.jpgSD3.jpg
                                                                               Reply  Fri Jul 29 03:32:30 2016, ericq, Update, General, ETMX suspended once more 
                                                                                  Reply  Fri Jul 29 13:17:34 2016, Koji, Update, General, Oven 
                                              Reply  Thu Jul 14 01:00:33 2016, Koji, Update, General, ETMX ruby guided gluing ruby.jpg
                                  Reply  Thu Jul 28 16:43:01 2016, Lydia, Update, General, ETMX aluminium standoff groove condition wire_damage_4.jpgwire_damage_zoom.jpgno_wire.jpgcomparison_2.jpg
                            Reply  Fri Jul 8 21:22:38 2016, gautam, Update, General, Vent progress - ETMX SUS Coil driver electronics investigation 
             Reply  Wed Jul 6 09:34:26 2016, Steve, Update, General, PRM sensing voltage LR PRM_LR.png
             Reply  Wed Jul 6 19:36:45 2016, Koji, Update, General, SUS Vmon HPF.png160706_ITMX_VMON2.pdf160706_ITMX_VMON1.pdf
                Reply  Thu Jul 7 15:23:39 2016, ericq, Update, General, SUS Vmon coil_drive.png
                   Reply  Thu Jul 7 16:05:55 2016, Koji, Update, General, SUS Vmon 
       Reply  Thu Jul 7 17:12:50 2016, Johannes, Update, General, Vent progress IMG_2621.JPGIMG_2623.JPGIMG_2628.JPGIMG_2595.JPG
          Reply  Tue Jul 12 23:51:16 2016, Johannes, Update, General, Vent progress - ETMY inspection IMG_2679.JPGIMG_2673.JPG
             Reply  Wed Jul 13 00:38:25 2016, Johannes, Update, General, Vent progress - ETMY attempted repositioning 
                Reply  Tue Jul 19 13:21:42 2016, Johannes, Update, General, Vent progress - ETMY attempted repositioning 
       Reply  Sun Jul 10 17:33:00 2016, ericq, Update, General, Vent progress 
          Reply  Mon Jul 11 15:13:22 2016, gautam, Update, General, Vent progress: in-date First Contact procured image.jpeg
Entry  Thu Jul 21 15:03:13 2016, varun, Update, CDS, DAFI Update festatus.pngmatrices.png
    Reply  Mon Aug 1 20:09:37 2016, rana, Update, CDS, DAFI Update 
Entry  Mon Aug 1 18:50:29 2016, Aakash, Update, General, Acromag Setup | SURF2016 7x
Entry  Sun Jul 31 17:28:38 2016, rana, Omnistructure, General, upclean 
Entry  Fri Jul 29 19:37:43 2016, Praful, Update, Electronics, Mic Amplifier 7x
Entry  Fri Jul 29 03:59:55 2016, ericq, Update, SUS, In air OSEM diagonalization check BS_OSEM_diag.pdf
Entry  Fri Jul 29 03:44:04 2016, Aakash, Summary, , About Acromag | SURF 2016 
Entry  Wed Jul 27 22:42:00 2016, Praful, Update, Electronics, EM172 Amplifier schematic.png
Entry  Tue Jul 26 14:24:38 2016, Koji, Summary, VAC, Purge compressed air system at LHO 12x
    Reply  Tue Jul 26 16:01:32 2016, Steve, Summary, VAC, Purge compressed air system cleanAirSupl.pdfmobileHEPA.jpg
       Reply  Tue Jul 26 17:41:59 2016, Koji, Summary, VAC, Purge compressed air system 
Entry  Tue Jul 26 09:56:34 2016, ericq, Update, CDS, c1susaux restarted 
Entry  Mon Jul 25 10:54:55 2016, Praful, Update, Computer Scripts / Programs, Finished MEDM Tab on Summary Pages 
    Reply  Mon Jul 25 12:22:18 2016, rana, Update, Computer Scripts / Programs, Finished MEDM Tab on Summary Pages 
Entry  Thu Jul 21 05:22:26 2016, Aakash, Update, General, Temperature measurements across the enclosure | SURF 2016 script21jul2016.mfig1.pdffig2.pdffig3.pdf
    Reply  Thu Jul 21 21:38:44 2016, Aakash, Update, General, Temperature measurements across the enclosure | SURF 2016 
       Reply  Fri Jul 22 05:20:26 2016, Aakash, Update, General, Temperature measurements across the enclosure | SURF 2016 coherence.pdftransferfunc.pdftransferfuncdB.pdfscript22jul2016.m
Entry  Fri Jul 22 03:02:37 2016, Koji, Update, COC, FC painting 11x
Entry  Sat Jul 16 00:30:42 2016, varun, Update, CDS, DAFI update: Frequency warping | c1lsc unresponsive 
    Reply  Thu Jul 21 22:02:35 2016, varun, Update, CDS, DAFI update: Frequency warping 07212016.png
Entry  Thu Jul 21 14:27:24 2016, varun, Update, CDS, DAFI Update: Arbitrary Math block dafioverview.pngarbmath.png
Entry  Thu Jul 21 12:03:35 2016, varun, Update, CDS, DAFI update: Humming noise in DAFI output New_Doc_13.pdf
Entry  Wed Jul 20 14:03:01 2016, ericq, Update, SUS, Effect of thicker ruby standoffs 
Entry  Thu Jul 14 23:38:59 2016, varun, Update, CDS, c1lsc FE unresponsive 
    Reply  Fri Jul 15 12:21:28 2016, varun, Update, CDS, c1lsc FE unresponsive 
       Reply  Mon Jul 18 18:44:52 2016, varun, Update, CDS, c1lsc FE recovered CDS_status160718.png
Entry  Mon Jul 18 05:05:05 2016, Aakash, Update, General, Heater for Seismometer Enclosure | SURF 2016 HEATERS.jpegHEATERS.jpeg
Entry  Fri Jul 15 17:44:37 2016, Aakash, Summary, General, Acromag Setup | SURF2016 
Entry  Wed Jul 13 15:35:56 2016, Lydia, Update, General, Vent Progress - ETMY repositioned and removed 
Entry  Tue Jul 12 20:16:15 2016, Lydia, Update, General, ITMX dust 
    Reply  Wed Jul 13 00:01:38 2016, Johannes, Update, General, ITMX dust 
       Reply  Wed Jul 13 03:16:47 2016, Koji, Update, General, ITMX dust 
Entry  Tue Jul 12 18:13:19 2016, Koji, Update, VAC, N2 bottle replaced 
Entry  Tue Jul 12 09:18:12 2016, ericq, Update, General, Slippery substance mystery 
    Reply  Tue Jul 12 09:35:51 2016, Johannes, Update, General, Slippery substance mystery 
Entry  Fri Jul 8 22:26:03 2016, varun, Update, CDS, DAFI Update: Changes in LSC model lsc.pnglsctodaf.pnglsctodaf1.png
    Reply  Sun Jul 10 20:08:44 2016, varun, Update, CDS, DAFI Update: Changes in LSC and PEM models pemtodaf.pngpemindaf.png
Entry  Tue Jul 5 14:12:56 2016, varun, Update, Electronics, Antialiasing Filter Update AA.pdfAAtop.pdfAAbottom.pdfAAbrd.pdfAA.zip
    Reply  Sun Jul 10 18:20:39 2016, rana, Update, Electronics, Antialiasing Filter Update 
Entry  Sun Jul 10 15:54:23 2016, ericq, Update, CDS, All models restarted 
Entry  Fri Jul 8 19:33:16 2016, Praful, Update, Computer Scripts / Programs, MEDM Tab on Summary Pages 
    Reply  Fri Jul 8 21:02:09 2016, Koji, Update, Computer Scripts / Programs, MEDM Tab on Summary Pages 
       Reply  Fri Jul 8 21:15:03 2016, Praful, Update, Computer Scripts / Programs, MEDM Tab on Summary Pages 
Entry  Fri Jul 8 15:44:07 2016, Praful, Update, Electronics, Replacing DIMM on Optimus 
Entry  Fri Jul 8 13:01:23 2016, Aakash, Update, General, Acromag is talking ! | SURF 2016 
Entry  Wed Jul 6 23:01:03 2016, gautam, Update, General, pianosa monitor dead 
    Reply  Thu Jul 7 14:45:26 2016, Koji, Update, General, pianosa monitor dead 
Entry  Thu Jul 7 12:44:52 2016, varun, Update, CDS, DAFI update DAFI.pdf
Entry  Fri Jun 10 16:19:03 2016, ericq, Update, SUS, ETMX watch 
    Reply  Mon Jun 13 10:01:58 2016, Steve, Update, SUS, ETMX jumps noDamping24hrs.pngETMXjumps.png
    Reply  Tue Jun 14 15:55:17 2016, ericq, Update, SUS, ETMX watch ETMX_wander.png
       Reply  Tue Jun 14 16:53:16 2016, rana, Update, SUS, ETMX watch 
       Reply  Thu Jun 16 11:10:17 2016, Steve, Update, SUS, spare ETMX optics preparation to be hanged SOSsus_Page_1.pngSOSsus_Page_2.pngETMXspareTowerFace.jpgETMXspareTowerBack.jpgmagnets-dumbbells.jpg
          Reply  Tue Jun 28 09:14:27 2016, Steve, Update, SUS, ETMX optics preparation to be rehanged nylonFCss.jpg
             Reply  Wed Jun 29 08:20:04 2016, Steve, Update, SUS, First Contact shelf life 
                Reply  Wed Jun 29 14:32:22 2016, Steve, Update, SUS, how to remove epoxy from optics 
                   Reply  Wed Jun 29 16:02:29 2016, Steve, Update, SUS, ETMX beam baffle IMG_1608.JPG
                   Reply  Thu Jun 30 10:03:16 2016, Steve, Update, SUS, how to remove epoxy from optics SOSsoakDish.jpgSOSsoakDish_tv.jpg
                      Reply  Thu Jun 30 14:31:02 2016, Chemistry, Update, SUS, NO mad-scientist.jpg
                      Reply  Tue Jul 5 09:25:31 2016, Steve, Update, SUS, how to remove epoxy from optics SOSsoakingDish.jpgSOSsoakingD.jpg
          Reply  Thu Jul 7 09:13:54 2016, Steve, Update, SUS, SOS gluing fixture SOSgluingFixRarmWend.jpgSOSgluingFixRarm.jpgSOSgluingFixLarm45.jpgSOSgluingFixLarm.jpgSOSgluingFixture.jpg
Entry  Wed Jul 6 17:17:22 2016, Praful, Update, Computer Scripts / Programs, New Tabs and Working Summary Pages 
    Reply  Wed Jul 6 21:05:36 2016, Koji, Update, Computer Scripts / Programs, New Tabs and Working Summary Pages cron_mail.txt.zip
       Reply  Wed Jul 6 21:09:09 2016, not Koji, Update, Computer Scripts / Programs, New Tabs and Working Summary Pages 
          Reply  Wed Jul 6 21:16:17 2016, Max Isi, Update, Computer Scripts / Programs, New Tabs and Working Summary Pages 
             Reply  Wed Jul 6 21:50:21 2016, Koji, Update, Computer Scripts / Programs, New Tabs and Working Summary Pages 
Entry  Wed Jul 6 16:40:09 2016, Aakash, Update, General, Seismometer Enclosure Development | SURF 2016 AD592CNZ_avg.pngAD592CNZ_diff.png
    Reply  Wed Jul 6 20:51:00 2016, Koji, Update, General, Seismometer Enclosure Development | SURF 2016 
Entry  Wed Jul 6 11:02:41 2016, Praful, Update, Computer Scripts / Programs, VMon Tab on Summary Pages 
Entry  Wed Jul 6 10:58:29 2016, Varun, Update, CDS, DAFI review 
Entry  Tue Jul 5 18:44:39 2016, Praful, Update, Computer Scripts / Programs, Working 40m Summary Pages 
Entry  Fri Jul 1 01:52:54 2016, Aakash, Update, General, Seismometer Enclosure Development | SURF 2016 DSC_0677.pngDSC_0678.png
Entry  Wed Jun 29 16:05:47 2016, ericq, Update, SUS, ETMX suspension readiness 
Entry  Tue May 17 05:50:43 2016, Varun Kelkar, Update, General, SURF 2016 
    Reply  Wed May 18 17:42:52 2016, Varun, Update, General, SURF 2016 
       Reply  Fri May 20 00:06:19 2016, Varun, Update, General, SURF 2016 
          Reply  Mon May 23 17:47:51 2016, Varun, Update, General, SURF 2016 cav_tr-eps-converted-to.pdfcav_tr_out-eps-converted-to.pdferr-eps-converted-to.pdferr_out-eps-converted-to.pdf
             Reply  Wed May 25 14:29:31 2016, Varun, Update, General, SURF 2016 
                Reply  Thu May 26 18:10:48 2016, Varun, Update, General, SURF 2016 input.pngoutput.png
    Reply  Wed May 25 11:51:40 2016, Steve, Update, safety, SURF 2016 safety 
       Reply  Tue May 31 16:52:58 2016, Steve, Update, safety, NONO nono.jpg
       Reply  Wed Jun 8 10:20:14 2016, Steve, Update, safety, SURF 2016 safety 
          Reply  Wed Jun 29 15:34:00 2016, Steve, Update, safety, SURF 2016 safety 
Entry  Wed Jun 29 00:09:36 2016, Aakash, Update, General, Things from past | SURF 2016 
Entry  Tue Jun 28 22:54:43 2016, Aakash, Update, General, Seismometer Enclosure Development | SURF 2016 plot1.pngplot2_corrected.png
Entry  Tue Jun 28 20:43:23 2016, Koji, Summary, COC, First Contact cleaning practice 7x
Entry  Tue Jun 28 17:11:27 2016, Praful, Update, General, EM172 Microphones 
Entry  Tue Jun 28 16:10:49 2016, Praful, Update, General, Bluebird Microphones 
Entry  Tue Jun 28 16:09:41 2016, Praful, Update, General, 40m Summary Pages 
Entry  Mon Jun 27 15:47:17 2016, Steve, Update, General, QPR clean room gloves 
Entry  Wed Dec 23 16:15:47 2015, rana, Omnistructure, ALARM, fire alarm 
    Reply  Mon Jun 27 15:26:03 2016, Steve, Omnistructure, ALARM, fire alarm test fireAlarmTest.png
ELOG V3.1.3-