40m QIL Cryo_Lab CTN SUS_Lab CAML OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 339 of 355  Not logged in ELOG logo
    Reply  Thu Feb 14 15:05:18 2008, rob, DAQ, DMF, seisBLRMS 1.1 


> Also, for reasons of aesthetics, I changed the data delay from 6 minutes to 5 minutes.  We'll see if that's enough.
Entry  Thu May 7 23:34:59 2009, rob, Update, SEI, seisBLRMS already lost 
Can't find hostname 'fb40m'
 
it only lasted a few hours
    Reply  Fri Mar 13 19:26:09 2009, Yoichi, Update, DMF, seisBLRMS compiled 
 I compiled seisBLRMS.
The tricks were the following:
(1) Don't add path in a deployed command. 
    Reply  Sun Mar 22 22:47:58 2009, rana, Update, DMF, seisBLRMS compiled but still dying 
Looks like seisBLRMS was restarted ~1 AM Friday morning but only lasted for 5 hours. I just restarted it on megatron;
let's see how it does. I'm not optimistic.
Entry  Sun May 17 23:22:19 2009, rana, Update, Environment, seisBLRMS for the past 3 weeks Untitled.png
Looks like Chris Wipf's fix of using fclose worked for the NDS client.
The attached plot shows the minute trend RMS - we should put the calibration for these into the .m file
so that the EPICS values are in something useful like microns or microns/sec.
    Reply  Fri Jun 26 19:14:04 2009, rana, Update, Environment, seisBLRMS for the past 3 weeks 
[COLOR=chocolate][SIZE=2]Restarted the seisBLRMS.m on mafalda (running a term on op540m). Don't know why it stopped - the
terminal had a 'disabled by EPICS' message even though the EPICS enable button was enabled.[/SIZE][/COLOR]
[SIZE=1][FONT=Comic Sans MS][COLOR=darkgreen]I also changed the delay from 4 to 2 minutes. So now it is calculating a 64 s PSD starting from 2 minutes
Entry  Mon Mar 9 19:33:10 2009, rana, Update, DMF, seisBLRMS in temp condition Untitled.png
The seisBLRMS has been running on megatron via an open terminal ssh'd into there from allegra with matlab running. This
is because I couldn't get the compiled matlab functionality to work.
Even so, this running script has been dying lately because of some bogus 'NDS' error. So for today I
Entry  Fri Mar 21 23:17:47 2008, rana, Configuration, DMF, seisBLRMS restarted 
I updated the seisBLRMS par file with the new channel names of the accelerometers and the seismometer and then
recompiled the code and restarted it according to Rob's elog entry. It went fine and the [SIZE=4][COLOR=chocolate][FONT=Comic Sans MS]seisBLRMS is now
back in
Entry  Sat Aug 7 21:57:56 2010, rana, Summary, DMF, seisBLRMS restarted Untitled.png
The green xterm on op540m which is running the seisBLRMS DMF got stuck somehow ~3 days ago and lost its NDS connection. I closed the matlab session and
restarted it. Seismic trends are now back online.
Entry  Mon Sep 13 02:45:59 2010, rana, Configuration, DMF, seisBLRMS restarts 
I restarted the seisBLRMS DMF monitor by ssh'ing into mafalda and starting up a matlab session. I also have started a StripTool session on rossa by forwarding
the process from op440m.
We need to get the modern EPICS installation onto these linux machines by copying what K. Thorne has done at LLO.
Entry  Fri Feb 1 12:37:39 2008, rob, Update, DMF, seisBLRMS trends seis36hours.pngseis2hours.png

Here are DV trends of the output of seisBLRMS over the last ~36 hours (which is how long it's been running), and another of the last 2 hours (which show
the construction crew taking what appears to be a lunch break).  
Entry  Fri Apr 6 16:22:15 2012, Den, Update, Environment, seism box 
I've changed R2 resistor in the seism box for the VERT 1 channel from 464 Ohm to 1051 Ohm to reduce the gain of this channel by a factor of 2. This should
help the GUR1Z signal not to be corrupted inside the AA box, so we can use it in the adaptive filtering.
Entry  Fri Apr 27 13:32:06 2012, Den, Update, PEM, seism channels pem.png
A few weeks ago I found that GUR2_X signal is biased from 0 to 800 counts in average. I decided that the corresponding channel in the readout box is
bad - adds DC voltage to the signal. I stopped using GUR2_XYZ channels of the seism readout box. Now the same thing happened with the GUR1_XYZ channels.
I checked the signals coming out from the seism box with the oscilloscope and they were fine. So the problem is not in the readout box. Then I applied
    Reply  Fri Feb 10 15:52:35 2012, Jenne, Update, PEM, seismic BLRMS loud too 


    
        
            Quote:
        
        
            

            
    Reply  Fri Feb 10 23:58:30 2012, rana, Update, PEM, seismic BLRMS loud too 


    
        
            Quote:
        
        
            

            
    Reply  Mon Feb 13 11:30:51 2012, Jenne, Update, PEM, seismic BLRMS loud too 


    
        
            Quote:
        
        
            
            
            
    
    Reply  Mon Feb 13 12:02:17 2012, Koji, Update, PEM, seismic BLRMS loud too 
I reported the procedure to add slow channels to the FB. I guess you already have done Step.1
http://nodus.ligo.caltech.edu:8080/40m/5991


    
        
            
Entry  Thu May 15 15:10:02 2014, Steve, Update, PEM, seismic activities  DichDay.pngDitchday8am.jpgAztecsGone.jpg
Our only seismometer is at the east end now.
Atm1, Ditch Day morning puzzle. The gardener came after the freshman did leave and cut the grass with the lawn mower.
Atm2, Yesterday afternoon the Aztecs containers moved out.
    Reply  Tue Sep 27 08:49:47 2016, Steve, Update, SUS, seismic activity is up 4.3mSaltonSee.pngITMXstuck.png
The earth quake shook ITMX free for a  short while.

 
    Reply  Tue Nov 1 09:03:08 2016, Steve, Update, SUS, seismic activity is up seismicActivity.png
Salton See is shaking again.

 
Entry  Mon May 7 01:07:58 2012, Den, Update, IOO, seismic in mcf pd-mcf.jpegfb.pngcoh_err_fb.pngmc2_suspos.jpg
I tried to figure out where additional (to seismic) noise enters to MC_F, so the coherence below 1 Hz is low (~0.2-0.5). I've examined noise in the path
PD -> DEMOD -> MC BOARD -> FSS -> PZT Controller -> LASER

    I terminated ADC and measured its noise
    connected MC BOARD OUT to ADC, terminated INPUT1 of the MC BOARD and measured
Entry  Sun May 6 01:41:55 2012, Den, Update, PEM, seismic in x,y arms coh_xyf.png
I locked x,y arms and measured coherence between POS{X,Y}11_I_ERR, MC_F and seismometer signals.
    Reply  Fri Feb 10 11:46:44 2012, steve, Update, IOO, seismic noise back to normal seism4h.pngseis60s.pngoneday.png
The shaking has stopped at 9:32am  The AC was turned back on at 11:30am  We still do not have any explanation
 
    Reply  Fri Feb 10 15:47:38 2012, rana, Update, PEM, seismic noise back to normal 
 
 Kiwamu and Steve maybe don't know about how to trend seismic noise. If you just take the mean of the time series, you don't prove that the
seismic noise got any higher. The STS has a nominally zero DC output, so the long period level shifts that you see tell you just that there was a DC offset.
Entry  Wed Nov 16 23:50:40 2011, Den, Update, Adaptive Filtering, seismic noise injection datespsd.jpgdatescoh.jpginjectionpsd.jpginjectioncoh.jpg
[Micro, Den]
Analyzing coherence of seismic noise and mode cleaner length we've figured out that at some days the coherence below 1 Hz is still present. For
example, at Nov 13 we can see some coherence compared to most other dates when we are not able to see coherence as shown on the figure. On the top plot
Entry  Mon Nov 28 18:53:35 2011, Den, Summary, WienerFiltering, seismic noise substraction 9x
There is still a problem why GUR, STS signals are poorly coherent to MC_L.  But at least we can see coherence at 2-5 Hz. It might be useful to do
something with adaptive filtering because it does not work at all for a long time. We start with Wiener filtering. I still doubt that static filtering
is useful. Adaptive filter output is linear to its coefficients, so why not to provide adaptive filter with a zero approximation equal to calculated Wiener
Entry  Tue Nov 14 16:02:43 2017, Kira, Summary, PEM, seismometer can testing time_const.png
I made a model for our seismometer can using actual data so that we know approximately what the time constant should be when we test it out. I used the
appendix in Megan Kelley's report to
make a relation for the temperature in terms of time.
    Reply  Tue Nov 21 16:00:05 2017, Kira, Update, PEM, seismometer can testing cooling_fit.pngIMG_20171121_164835.jpg
I performed a test with the can last week with one layer of insulation to see how well it worked. First, I soldered two heaters together in series so
that the total resistance was 48.6 ohms. I placed the heaters on the sides of the can and secured them. Then I wrapped the sides and top of the can
in insulation and sealed the edges with tape, only leavng the handles open. I didn't insulate the bottom. I connected the two ends of the heater directly
    Reply  Wed Nov 22 12:13:15 2017, Kira, Update, PEM, seismometer can testing cooling_fit_1.png
Updated some values, most importantly, the k-factor. I had assumed that it was in the correct units already, but when converting it to 0.046 W/(m^2*K)
from 0.26 BTU/(h*ft^2*F), I got the following plot. The time constant is still a bit larger than what we'd expect, but it's much better with these
adjustments.
    Reply  Wed Nov 22 14:47:03 2017, Kira, Update, PEM, seismometer can testing 
For the insulation, I have decided to use this one (Buna-N/PVC Foam Insulation
Sheets). We will need 3 of the 1 inch plain backing ones (9349K4) to wrap a few layers around it. I'll try two layers for now, since the insulation
seems to be doing quite well according to initial testing.
    Reply  Tue Nov 28 16:02:32 2017, rana, Update, PEM, seismometer can testing 
I've ordered 4 of these from McMaster. Should be delivered to the 40m by noon tomorrow.




Quote:



For the insulation, I have decided to use this
    Reply  Tue Apr 17 09:57:09 2018, Steve, Update, General, seismometer interfaces BS_Tril_Intrf-1X5.jpgGurs_Intf-1X1.jpg
 




Quote:



I've been looking into recovering the seismic BLRMs for the BS Trillium seismometer. It looks like
    Reply  Wed Apr 18 20:33:19 2018, Kevin, Update, General, seismometer interfaces front.jpgback.jpgconnectors.jpg
Steve, the pictures you posted are not the AA board I was referring to. The attached pictures show the board which is sitting beneath the GPS time server.
Entry  Mon Apr 15 16:10:52 2013, Den, Update, PEM, seismometer isolation kit  
 We got granite bases today from the manufacturer. We plan to set them up on Wednesday, 8 am. Please note, there will be an installation
mess at Xend, Yend and corner during ~4 hours. Let us know if you have any objections to do this at this particular time. 
Installation locations are specified in elog 8270, scheme attached is valid except
    Reply  Thu Apr 18 15:08:14 2013, Steve, Update, PEM, seismometer isolation kit in place grouting1.jpggrouting2.jpggrouting3.jpggrouting4.png


    
        
            Quote:
        
        
            

            We got granite bases today from the manufacturer. We plan to set them up on Wednesday, 8 am. Please note, there will be an installation
    Reply  Tue Apr 23 16:17:45 2013, Den, Update, PEM, seismometer isolation kit in place Base.pdf.pdfConnectorPlate.pdf


    
        
            Quote:
        
        
            

            
Entry  Sat Aug 11 18:57:07 2012, Den, Update, PEM, seismometer location 
STS-2 - end of X arm
GUR 2 - isolation box
TRILLIUM - 1Y3 (DC power supply uses 1Y3 AC power, please do not close the door completely)
    Reply  Thu Dec 13 01:49:53 2012, rana, Update, PEM, seismometers a.pdf


    
        
            Quote:
        
        
            

           I've installed Guralp readout box back and it turned out that it does not work with voltage provided from the rack (+13.76 0 -14.94). 
    Reply  Thu Dec 13 21:21:34 2012, Den, Update, PEM, seismometers gur.pdfgur_fix.pdf


    
        
            Quote:
        
        
            

            
Entry  Wed Jun 2 18:09:32 2010, steve, Update, PEM, seismometers off of linoleum floor 
Steve for Nancy,
Seismometer interface box ac power was turned off, Guralps disconnected and moved. Ranger locked, moved and released. Nancy will describe the rest
soon.
    Reply  Wed Jun 2 21:21:43 2010, steve, Update, PEM, seismometers off of linoleum floor 


    
        
            Quote:

       
        
            
            Steve for Nancy,
    Reply  Thu Jun 3 22:17:05 2010, rana, Update, PEM, seismometers off of linoleum floor Untitled.pnga.pngUntitled.png
 At ~2350 UTC on June 2, the seismometers were turned off. After the granite slab was repositioned with the new lead, the Ranger was turned on,
but not the Guralps.
Now, after ~24 hours, I have put the Guralps onto the granite and turned them on. During this off time, the input channels should be ADC noise
    Reply  Fri Jun 4 23:52:57 2010, rana, Update, PEM, seismometers off of linoleum floor Untitled.pnghuddlez.png
 
Entry  Wed Nov 18 01:12:15 2009, rana, Update, PEM, seismometers were not saturating during Halloween weekend Untitled.png
 
    Reply  Thu Aug 23 10:08:13 2012, Steve, Update, PEM, seismometers? bajaMag3.pngseisvssus.png


    
        
            Quote:
        
        
            

           It seems as though there is something funny going on around ~1.5 Hz, starting a little over an hour ago.
    Reply  Sun Dec 3 05:25:59 2017, gautam, Configuration, Computers, sendmail installed on nodus  
Pizza mail didn't go out last weekend - looking at logfile, it seems like the "sendmail" service was missing. I installed sendmail following
the instructions here: https://tecadmin.net/install-sendmail-server-on-centos-rhel-server/

Except that to start the sendmail service, I used systemctl and not init.d. i.e. I ran 
    Reply  Sun Dec 3 17:01:08 2017, Koji, Configuration, Computers, sendmail installed on nodus  
An email has come at 5PM on Dec 3rd.

 
Entry  Mon Jan 27 17:49:46 2014, rana, HowTo, Computer Scripts / Programs, sendmail started on nodus: fixing SwiftMail on Dokuwiki 
Since the recent filesystem fracas, the new accounts could not be created on nodus / dokuwiki (for the controls workshop, for example).
I started sendmail on nodus using the command:   sudo /etc/init.d/sendmail start
and the SwiftMail plugin on there is now sending out the confirmation emails again. This will happen each time we reboot nodus, so let's replace
    Reply  Fri Jan 12 12:31:04 2018, gautam, Configuration, Computers, sendmail troubles on nodus  
I'm having trouble getting the sendmail service going on nodus since the Christmas day power failure - for some reason, it seems
like the mail server that sendmail uses to send out emails on nodus (mx1.caltech.iphmx.com,
IP=68.232.148.132) is on a 
    Reply  Fri Jan 12 16:01:27 2018, Koji, Configuration, Computers, sendmail troubles on nodus  
I personally don't like the idea of having sendmail (or something similar like postfix) on a personal server as it requires a lot of maintenance
cost (like security update, configuration, etc). If we can use external mail service (like gmail) via gmail API on python, that would easy our worry, I
thought.
ELOG V3.1.3-