40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 339 of 344  Not logged in ELOG logo
ID Date Author Typeup Category Subject Text Attachments
  16934   Tue Jun 21 18:41:46 2022 TomislavUpdateASCSimulation plotIn the attachment please find a comparison
of error signals of simulation and reality.
For C1:IOO-WFS1/2_PIT_IN1 excess signal ('belly')
 sens_output_comparison.png 
  16935   Tue Jun 21 21:17:16 2022 yutaUpdateBHDRTS models for BHD added but PCIE error remaining[Anchal, Yuta]

RTS
models for BHD homodyne phase control (c1hpc)
 Screenshot_2022-06-21_20-12-55_C1HPC.pngScreenshot_2022-06-21_20-14-56_C1SU2.pngScreenshot_2022-06-21_20-13-38_C1LSC.pngScreenshot_2022-06-21_20-34-44_RED.png 
  16937   Tue Jun 21 22:22:37 2022 TomislavUpdateASCPlotsIn the attachment please find a comparison
of error signals of simulation and reality
after including air turbulence as input noise.
 sens_output_comparison_with_air_turbulence.png 
  16938   Wed Jun 22 14:44:03 2022 AnchalUpdateBHDFixed DC error in c1su2, added new library model for suspensionsThe 0x2000 error in c1su2 happens whenever
we make it and install it as the default
data acquisition rates are too much in the
  
  16940   Wed Jun 22 18:55:31 2022 yutaUpdateLSCDaily alignment work; POY trouble solved[Koji, Yuta]

I found that Yarm cannot be locked
 Screenshot_2022-06-22_17-17-42_XYaligned.pngScreenshot_2022-06-22_18-58-26_Transmission.png 
  16941   Wed Jun 22 19:41:13 2022 KojiUpdateLSCDaily alignment work; POY trouble solvedBefore the final measurement of the DC
values for the transmissions, I aligned the
PMC. This made the PMC trans increased from
  
  16942   Thu Jun 23 15:05:01 2022 Water MonitorUpdateUpgradeWater Bottle Refill22:05:02 UTC Jordan refilled his water
bottle at the water dispenser in the control
room.
  
  16943   Fri Jun 24 12:13:16 2022 JCUpdateIOOWFS issues[Yuta, JC]

It seems that early this morning
MC got very misaligned. Yuta was able to
 WFS.png 
  16944   Fri Jun 24 13:29:37 2022 YehonathanUpdateGeneralOSEMs from KAGRAThe box was given to Juan Gamez (SURF)




  
  16945   Fri Jun 24 17:16:59 2022 PacoUpdateALSXAUX cable in control room[JC, Paco]

We took the long BNC cable that
ran from ETMX to ETMY and ran it from ETMX
  
  16946   Sat Jun 25 14:29:48 2022 AnchalUpdateIOOWFS issuesThis issue is very weird and still unresolved.
Without WFS loops, we'll have to realign
IMC often and we might loose IMC alignment
  
  16947   Sat Jun 25 20:23:59 2022 KojiUpdateIOOWFS issuesI could run the WFS servo (6dofs) for more
than 15min by flipping the sign for the MC2
Pit and WFS1 Yaw. (See attachments)
 Screen_Shot_2022-06-25_at_20.23.21.pngScreen_Shot_2022-06-25_at_20.29.24.png 
  16948   Sat Jun 25 22:18:41 2022 TomislavUpdateASCSimulation and reality comparisonsIn the attachment please find plots comparing
controller output, local damping output,
and error signals.
 sens_output_comparison_23_6_new.pngcontr_out_comparison_23_6_new.pnglocal_damp_out_comp_23_6_new.png 
  16949   Mon Jun 27 12:32:45 2022 yutaUpdateIOOWFS issues fixed    
  16950   Mon Jun 27 13:25:50 2022 CiciUpdateGeneralCharacterizing the Transfer Loop[Deeksha, Cici]

We first took data of a simple
low pass filter, and attempted to perform
 TF_measurement_b.pngtransfer_function_mag_fit.pngtransfer_function_phase_fit.pngcontrol_flow.png 
  16951   Mon Jun 27 13:39:40 2022 DeekshaUpdateElectronicsSetting up the MokuLab[Cici, Deeksha]

On Friday Cici and I set up the
Mokulab to take readings of our loop. The
 WhatsApp_Image_2022-06-24_at_5.21.28_PM.jpeg 
  16952   Mon Jun 27 18:54:27 2022 yutaUpdateLSCModulation depths measurement using Yarm cavity scan[Yehonathan, Yuta]
EDITED
by YM on 22:11 June 27, 2022 to correct for
 YarmModIndex.png 
  16953   Tue Jun 28 09:03:58 2022 JCUpdateGeneralOrganizing and CleaningThe plan for
the tools in 40m

As of right now, there are 4 tool
  
  16954   Tue Jun 28 14:24:23 2022 yutaUpdateBHDBHD DC PD signals now also sent to c1lsc to circumvent IPC error[JC, Yuta]

To circumvent IPC error sending
BHD DC PD signals from c1sus2 to c1lsc, DB9
 C1LSC.JPGC1SUS2.JPGScreenshot_2022-06-28_16-03-16_BHDDCPDcopied.png 
  16957   Tue Jun 28 17:07:47 2022 AnchalUpdateCalibrationAdded Beatnote channels in demodulation of c1calI added today demodulation of C1:LSC-BEATX/Y_FINE_I/Q
in the c1cal demodulation where different
degrees of freedom can be dithered. For McCal
  
  16958   Tue Jun 28 18:19:09 2022 TomislavUpdateElectronicsElectronics noiseI measured electronics noise of WFSs and
QPD (of the WFS/QPD, whitening, ADC...) by
closing PSL and measuring the error signal.
 electronics_noise_spectra.pngerror_signal.png 
  16960   Tue Jun 28 22:27:11 2022 YehonathanUpdateBHDMeasurement of input and output electronics noise{Yuta, Yehonathan}

For MICH noise budgeting we measure
the input electronics noise which includes
 input_noise_spectrum.pdfoutput_noise_spectrum.pdf 
  16961   Tue Jun 28 23:10:34 2022 YehonathanUpdateBHDMeasurement of AS55 demod board conversion factor{Yuta, Yehonathan}

We measured the AS55 demod board
conversion from the amplitude of a 55MHz
  
  16963   Wed Jun 29 18:53:38 2022 ranaUpdateElectronicsElectronics noisethis is just the CDS error signal, but
is not the electronics noise. You have to
go into the lab and measure the noise at
  
  16965   Thu Jun 30 18:06:22 2022 PacoUpdateALSOptimum ALS recovery - part I[Paco]

In the morning I took some time
to align the AUX beams in the XEND table.
 als_ool_06_2022.png 
  16969   Fri Jul 1 12:49:52 2022 KojiUpdateIOOMC2 seemed misaligned / fixedI found the IMC was largely misaligned
and was not locking. The WFS feedback signals
were saturated and MC2 was still largely
 C1-MULTI_FBDB3F_TIMESERIES-1340668818-86400.pngC1-LOCKED_MC_5E4267_TIMESERIES-1340668818-86400.png 
  16972   Tue Jul 5 20:05:06 2022 TomislavUpdateElectronicsWhitening electronics noiseFor whitening electronics noise for WFS1,
I get (attachment). This doesn't seem
right, right?
 whitening_noises.png 
  16973   Wed Jul 6 15:28:18 2022 TegaUpdateSUSOutput matrix diagonalisation : F2P coil balancinggit repo : https://git.ligo.org/40m/scripts/-/tree/main/SUS/OutMatCalc

local dir: 
  
  16974   Wed Jul 6 18:51:20 2022 DeekshaUpdateElectronicsMeasuring the Transfer Function of the PZTYesterday, we set up the loop to measure
the PZT of the transfer function - the MokuLab
sends an excitation (note - a swept sine
 pzt_transfer_fn.pngckt_diagram.jpegMokuPhaseMeterTFData_20220706_174753_TF_Data.txt 
  16977   Thu Jul 7 18:18:19 2022 yutaUpdateLSCActuator calibration of ETMX and ETMX(This is a
complete restore of elog 40m/16970
from July 5, 2022 at 14:34)
 Screenshot_2022-07-05_14-52-01_OLTF.pngScreenshot_2022-07-05_14-54-03_TF.pngScreenshot_2022-07-05_14-56-41_Ratio.png 
  16978   Thu Jul 7 18:22:12 2022 yutaUpdateLSCActuator calibration of MC2 using Yarm(This is also
a restore of elog 40m/16971
from Jul 5, 2022 at 17:36)
 TF.pngMC2.png 
  16981   Fri Jul 8 16:18:35 2022 ranaUpdateLSCActuator calibration of MC2 using Yarmalthough I know that Yuta knows this, I
will just put this here to be clear: the
NNN/f^2 calibration is only accurate abouve
  
  16984   Mon Jul 11 11:56:40 2022 he YehonathanUpdateBHDMICH AS55 noise budgetI calculated a noise budget for the MICH
using AS55 as a sensor. The calculation includes
closed-loop TF calculations.
 Control_Diagram.pdfMICH_AS55_Noise_Budget.pdf 
  16986   Mon Jul 11 17:25:43 2022 TegaUpdateVACfixed obsolete reference bug in serial_XGS600 serviceKoji noticed that the FRG sensors were
not updating due to reference to an
obsolete modbusIOC_XGS service, which was
  
  16989   Tue Jul 12 09:14:50 2022 ranaUpdateBHDMICH AS55 noise budgetLooking good:


I think the notches you
see in he measured noise are a clue as to
  
  16990   Tue Jul 12 09:25:09 2022 ranaUpdateIOOIMC WFSMC WFS
Demod board needs some attention.
  
  16995   Wed Jul 13 07:16:48 2022 JCUpdateElectronicsChecking Sorensen Power Supplies[JC]

I went around 40m picking up any
Sorensens that were laying around to test
 658C5D39-11BD-4EE3-90E2-34CBBC1DBD3C.jpeg5328312A-7918-44CC-82B7-54B57840A336.jpeg 
  16996   Wed Jul 13 10:54:39 2022 YehonathanUpdateBHDMICH AS55 noise budgetI fixed some mistakes in the budget:

1. The BS pendulum resonance was
corrected from 0.8Hz to 1Hz
 BS_MICH_ACtuation_Calibration.pdfMICH_AS55_Model_Measurement_Comparison.pdfMICH_AS55_Noise_Budget.pdf 
  16999   Wed Jul 13 13:30:48 2022 YehonathanUpdateBHDadd Laser RIN to MICH budgetthe main laser noise coupling for a Michelson
is because of the RIN, not the frequency
noise. You can measure the RIN, in MC trans
  
  17000   Wed Jul 13 17:30:19 2022 KojiUpdateCDSToo huge script_archiveI wanted to check the script archive to
see some old settings. I found that the script archive
  
  17001   Wed Jul 13 18:58:17 2022 KojiUpdateIOOIMC suspecionThis is just my intuition but the IMC servo
seems not so optimized. I can increase the
servo gain by 6~10dB easily. And I couldn't
  
  17003   Thu Jul 14 19:09:51 2022 ranaUpdateGeneralEQ recoveryThere was a EQ in Ridgecrest (approximately
200 km north of Caltech). It was around 6:20
PM local time.
 ETMY-screen.png 
  17004   Thu Jul 14 19:56:15 2022 ranaUpdateIOOmc wfs demodIt looks like Tomislav's measurements
of the WFS demod board noise were actually
of the cable that goes from the whitening
 mcwfs-steps.pdf 
  17005   Fri Jul 15 12:21:58 2022 JCUpdateElectronicsChecking Sorensen Power SuppliesOf the 7 Sorenson Power Supplies I tested,
5 are working fine, 1 cannot output voltage
more than 20 Volts before shorting, and other
 50DF21D7-D61A-4674-B0DA-463378B00ADB.jpegFA4CF579-6C1E-48D5-B152-74F35B4EE90B.jpeg 
  17006   Fri Jul 15 16:20:16 2022 Cici HannaUpdateGeneralFinding UGFI have temporarily abandoned vectfit and
aaa since I've been pretty unsuccessful
with them and I don't need poles/zeroes
 UGF_4042.pngUGF_5650.pngTFSR785_29-06-2022_114042.txtTFSR785_29-06-2022_115650.txt 
  17009   Sat Jul 16 02:44:10 2022 KojiUpdateIOOIMC servo tuningI wasn't sure how the IMC servo was
optimized recently. We used to have the FSS
over all gain (C1:PSL-FSS_MGAIN) of +6dB
 ErrorPSD.pdfOLTF.pdfScreen_Shot_2022-07-16_at_03.59.05.png 
  17010   Mon Jul 18 04:42:54 2022 AnchalUpdateCalibrationError propagation to astrophysical parameters from detector calibration uncertaintyWe can calculate how much detector calibration
uncertainty affects the estimation of astrophysical
parameters using the following method:
 BNSparamsErrorwrtfdError-merged.pdfBBHparamsErrorwrtfdError-merged.pdfBNSparamsEPSwrtCalError.pdfBBHparamsEPSwrtCalError.pdf 
  17011   Mon Jul 18 15:17:51 2022 HangUpdateCalibrationError propagation to astrophysical parameters from detector calibration uncertainty1. In the error propogation equation, it
should be \Delta \Theta = -H^{-1} M \Delta
\Lambda, instead of the fractional error. 
  
  17013   Mon Jul 18 16:49:57 2022 YehonathanUpdateBHDadd Laser RIN to MICH budgetI measured the RIN by taking the spectrum
of C1:MC_TRANS_SUMFILT_OUT and
dividing it by the mean count on that channel
 Laser_RIN.pdfMICH_AS55_Noise_Budget.pdf 
  17014   Mon Jul 18 17:07:12 2022 yutaUpdateLSCx4.12 added to ETMX coil outputs to balance with ETMYTo balance the actuation on ETMX and ETMY,
x4.12
was aded to C1:SUS-ETMX_(UL|UR|LR|LL|SD)COIL
  
ELOG V3.1.3-