40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 338 of 341  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
Entry  Wed Apr 13 00:56:07 2016, gautam, Update, endtable upgrade, X endtable repopulation 
    Reply  Wed Apr 13 11:00:28 2016, Steve, Update, endtable upgrade, X endtable repopulation 
    Reply  Wed Apr 13 18:25:07 2016, gautam, Update, endtable upgrade, Lightwave health check 
    Reply  Fri Apr 15 18:38:12 2016, gautam, Update, endtable upgrade, Lightwave health check - NO IMPROVEMENT 
    Reply  Tue Apr 19 18:37:29 2016, gautam, Update, endtable upgrade, Laser swap + optical layout IR_modematch_19April2016_2.pdf
    Reply  Thu Apr 21 14:25:52 2016, gautam, Update, endtable upgrade, Green light recovered IMG_6567.JPGIMG_6568.JPGCVI_reflectivity.jpeg
    Reply  Tue Apr 26 15:22:35 2016, Steve, Update, endtable upgrade, Cleaning ETMX vacuum dirty window ETMX-Tvp.jpgETMX-TvpDetail.jpg
    Reply  Tue Apr 26 23:19:42 2016, gautam, Update, endtable upgrade, Green aligned to arm - high order mode flashes seen IMG_2219.JPGIMG_2220.JPG
    Reply  Wed Apr 27 15:04:47 2016, Steve, Update, endtable upgrade, Cleaning ETMX vacuum dirty window 1cETMX-Tcmp.jpg
    Reply  Thu Apr 28 00:41:08 2016, gautam, Update, endtable upgrade, more progress - Transmon PD installed 
    Reply  Fri Apr 29 00:55:46 2016, gautam, Update, endtable upgrade, green PDH locked to Xarm 
    Reply  Fri Apr 29 16:05:23 2016, gautam, Update, endtable upgrade, Cleaning ETMX vacuum dirty window IMG_0755.JPG
    Reply  Mon May 2 19:14:18 2016, gautam, Update, endtable upgrade, Optical layout almost complete ETMX_wedge.pdf
    Reply  Thu May 5 03:05:37 2016, gautam, Update, endtable upgrade, ALS status update ALS_noiseSpec_5May2016_2.pdfCoherence_5May2016.pdfimage.jpeg
    Reply  Thu May 5 14:05:01 2016, rana, Update, endtable upgrade, ALS status update 
    Reply  Thu May 5 21:28:44 2016, gautam, Update, endtable upgrade, Innolight PZT capacitance 
    Reply  Thu May 19 16:29:20 2016, Steve, Update, endtable upgrade, Optical layout almost complete ETMX_4x3_closed.jpgsealedETMXenclosure.jpg
    Reply  Fri Sep 30 19:53:07 2016, gautam, Update, endtable upgrade, X end IR pickoff fiber coupled 
    Reply  Wed Oct 5 16:28:10 2016, gautam, Update, endtable upgrade, EX laser power monitor PD installed 
Entry  Tue Apr 22 22:19:02 2008, rob, Metaphysics, lore, jiggling sliders 
Entry  Sun Nov 2 20:21:58 2008, rana, Configuration, lore, HP 5550dtn (Grazia) set up on allegra 
    Reply  Thu Jan 8 16:49:37 2009, rana, Configuration, lore, HP 5550dtn (Grazia) set up on allegra 
Entry  Wed May 13 02:53:12 2009, rob, Summary, lore, Channel Hopping: That ancient enemy (MC problems) 
    Reply  Wed May 13 14:43:29 2009, rob, Summary, lore, Channel Hopping: That ancient enemy (MC problems) MC3sidemon.png
Entry  Fri Oct 23 15:02:00 2009, rob, Update, lore, marconi phase 
    Reply  Sat Oct 24 04:57:33 2009, rana, Update, lore, marconi phase 
Entry  Mon Dec 14 15:18:18 2009, Jenne, Update, lore, armLoss script ran....results confidential 
    Reply  Wed Feb 3 09:01:42 2010, rob, Update, lore, IFO isn't playing nice tonight 
Entry  Fri Feb 12 14:19:28 2010, rana, steve, HowTo, lore, International Fax 
Entry  Wed Oct 6 14:49:54 2010, rana, Summary, lore, Steve on the sea jacques.jpg
Entry  Mon Jul 11 14:03:37 2011, steve, HowTo, lore, how to visit your old lab P1080069.JPG
Entry  Sun May 27 17:19:27 2012, rana, Summary, lore, Strawberries 20120527_145826.jpg
Entry  Mon Jul 22 03:10:41 2013, rana, Summary, lore, Angel of the Y End Table? asdasd.jpg
    Reply  Mon Jul 22 06:58:17 2013, Lisa, Summary, lore, Angel of the Y End Table? image.jpg
Entry  Fri May 16 20:55:18 2014, Jamie, Frogs, lore, un-full-screening Ubuntu windows with F11 
Entry  Wed Mar 29 09:24:28 2017, Steve, Update, lore, summery pages 
Entry  Thu Oct 2 16:44:28 2008, steve, Summary, oplevs, optical levers 
Entry  Thu Jan 22 12:08:59 2009, pete, Update, oplevs, oplev calibration 
Entry  Thu Jan 22 23:36:50 2009, pete, HowTo, oplevs, arm cavity oplev calibration ETMYpitpower.pngETMYpitcal.png
    Reply  Fri Jan 23 12:48:12 2009, Kakeru, Update, oplevs, arm cavity oplev calibration ITMX_pitch.png
Entry  Fri Jan 23 16:33:27 2009, pete, Update, oplevs, x-arm oplev calibrations 
    Reply  Thu Jan 29 17:24:41 2009, Kakeru, Update, oplevs, arm cavity oplev calibration 
Entry  Mon Mar 9 17:11:38 2009, Alberto, Configuration, oplevs, optical levers centering 
    Reply  Sat Mar 14 22:53:12 2009, Kakeru, Update, oplevs, arm cavity oplev calibration oplev.pdf
    Reply  Fri Mar 20 15:37:58 2009, Kakeru, Update, oplevs, arm cavity oplev calibration 
    Reply  Thu Mar 26 09:08:18 2009, Kakeru, Update, oplevs, arm cavity oplev calibration 
Entry  Fri May 8 04:46:01 2009, rana, yoichi, Summary, oplevs, BS/PRM/SRM table bad! a.png
Entry  Tue May 12 17:26:56 2009, pete, Update, oplevs, etmy oplev quad was bad bad_oplev_quad.pdf
    Reply  Wed May 13 03:05:13 2009, pete, Update, oplevs, etmy oplev quad was bad 
Entry  Tue Jun 2 23:55:45 2009, Alberto, Update, oplevs, oplevs centerd 
ELOG V3.1.3-