Entry  Mon Jan 25 16:30:37 2010, Alberto, Update, ABSL, 166 MHz sideband turned off 
I turned off the modulation at 166MHZ becasue I don't need it if I'm only locking the PRC.
It was introducing extra amplitude modulations of the beam which interfered with the AbsL's PLL photodiode.
I'm going to turn it back on later on.
    Reply  Mon Jan 25 16:46:33 2010, Alberto, Update, ABSL, 166 MHz sideband turned off 


    
        
            Quote:
        
        
            
            I turned off the modulation at 166MHZ becasue I don't need it if I'm only locking the PRC.
    Reply  Tue Jan 26 03:28:56 2010, rana, Update, ABSL, 166 MHz sideband turned off 
 
 You can turn the 166 off if you want. MZ is unhappy after its turned off, but that's just the thermal transient from removing the RF heat.
After a several minutes, the heat goes away and the MZ can be relocked.
Entry  Wed Jan 27 11:02:30 2010, Alberto, Update, ABSL, PRC Cavity Length 2010-01-21_PRCtransmissivityVsFit.png2010-01-21_PRCtransmissivity_EntireFreqRange_VsFit.png
 I fitted the data from scanning the PRC by changing the beat frequency of the auxiliary laser beam with the PSL beam.
The data points
that I've taken so far over the entire frequency range (0-300 MHz) are not continuous. For several reasons the PLL was unable to maintain
lock for such a large range and I had to break it into smaller segments. The measurements to acquire them stretched over a too long period of
Entry  Fri Jan 29 12:06:58 2010, Alberto, Update, ABSL, Measurement running today at lunch time 
I just started a measuremtn that will be running for the next hour or so. Please be careful with the interferometer.
    Reply  Fri Jan 29 13:14:49 2010, Alberto, Update, ABSL, Measurement running today at lunch time 


    
        
            Quote:
        
        
            
            I just started a measuremtn that will be running for the next hour or so. Please be careful with the interferometer.
Entry  Mon Feb 8 14:13:03 2010, Alberto, Update, ABSL, PLL Characterization 2010-02-08_Old_PDH_Box_Filter_TF_gain_knob_0_Boost_OFF.png2010-02-08_PLL_OLG_gain_knob_0_Boost_OFF.png2010-02-08_PLL_Noise_Budget.png
Lately I've been trying to improve the PLL for the AbsL experiment so that it could handle larger frequency steps and thus speed up the cavity scan.
The maximum frequency step that the PLL could handle withouth losing lock is given by the DC gain of the PLL. This is the product of the mixer's
gain factor K [rad/V ], of the laser's calibration C [Hz/V] and of the PLL filter DC gain F(0).
Entry  Mon Feb 8 14:56:17 2010, Alberto, Update, ABSL, Suddenly a much better alignment of PRC 
I just aligned PRM and locked PRC and I noticed that SPOB is much higehr than it used to be. It's now about 1800, vs 1200 than it used to be last week.
Isn't anyone related to that? If so, may I please know how he/she did it?
    Reply  Mon Feb 8 15:01:46 2010, rob, Update, ABSL, Suddenly a much better alignment of PRC 


    
        
            Quote:
        
        
            
            I just aligned PRM and locked PRC and I noticed that SPOB is much higehr than it used to be. It's now about 1800,
    Reply  Mon Feb 8 15:41:51 2010, Alberto, Update, ABSL, Suddenly a much better alignment of PRC 


    
        
            Quote:
        
        
            
            
            
    
    Reply  Tue Feb 9 09:07:06 2010, Alberto, Update, ABSL, PLL Characterization 2010-02-08_PRCtransmissivity_EntireFreqRange_VsFit.png


    
        
            Quote:
        
        
            
            Lately I've been trying to improve the PLL for the AbsL experiment so that it could handle larger frequency steps
Entry  Tue Feb 9 10:10:58 2010, Alberto, Update, ABSL, back to analog 
I want to try to do the measurement with the network analyzer used as local oscillator, instead of the Marconis that I'm using now. Tha could give me
better noise rejection. It would also give me information about the phase.
Also I wouldn't dislike abandoning the GPIB interfaces to acquire data.
Entry  Thu Mar 18 10:46:51 2010, Koji, Update, ABSL, PLL reconstructed 
Last night (Mar 17) I checked the PLL setup as Mott have had some difficulty to get a clean lock of the PLL setting.

    I firstly found that the NPRO beam is not going through the Faraday isolator well. This was fixed by aligning the steering mirrors before
the Faraday.
    Reply  Thu Mar 18 12:27:56 2010, Alberto, Update, ABSL, PLL reconstructed 


    
        
            Quote:
        
        
            
            Last night (Mar 17) I checked the PLL setup as Mott had some difficulty to get a clean lock of the PLL setting.
    Reply  Thu Mar 18 13:40:35 2010, Koji, Update, ABSL, PLL reconstructed 
We use the current PLL just now, but the renewal of the components are not immediate as it will take some time. Even so we need steady steps towards
the better PLL. I appreciate your taking care of it.


    
        
            
    Reply  Thu Mar 18 21:42:26 2010, Koji, Update, ABSL, PLL reconstructed 
I checked the setup further more.

    I replaced the PD from NewFocus 1GHz one to Thorlabs PDA255.
    I macthed the power level of the each beam.

Now
I have significant fraction of beating (30%) and have huge amplitude (~9dBm). 
    Reply  Mon Mar 22 22:11:26 2010, Mott, Update, ABSL, PLL reconstructed IMG_0150.JPG
 
 It looks like the PLL drifted alot over the weekend, and we couldn't get it back to 9 dBm.  We switched back to the new focus wideband
PD to make it easier to find the beat signal.  I replaced all the electronics with the newly fixed UPDH box (#17) and we aligned it to the biggest
    Reply  Mon Mar 22 23:37:32 2010, Mott, Update, ABSL, PLL reconstructed 2010-03-22_23.14.00.jpg2010-03-22_23.24.50.jpg
 
We have managed to lock the PLL to reasonable stability. The RF input is attenuated by 26 dBm and the beat signal locks very close to the carrier
of the marconi (the steps on the markers of the spectrum analyzer are coarse).  We can use the marconi and the local boost of the pdh box to catch
    Reply  Tue Mar 23 18:44:46 2010, Mott, Update, ABSL, PLL reconstructed NPRO_PLL_freqresp.png
 
 After realigning and getting the lock today, I tried to add in the SR785 to measure the transfer function.  As soon as I turn on the
piezo input on the PDH box, however, the lock breaks and I cannot reacquire it.  We are using an SR650 to add in the signal from the network analyzer
Entry  Fri Jun 17 16:05:07 2011, kiwamu, Update, ABSL, LightWave out of MOPA box DSC_3139_small.png
[Suresh / Kiwamu]
 We did the following things :
   - Took the LightWave NPRO out from the MOPA box
    Reply  Mon Jun 20 11:38:49 2011, kiwamu, Update, ABSL, I-P curve of LightWave M126-1064-700 IP_curve.png
The I-P curve of the LightWave NPRO (M126-1064-700), which was taken out from the MOPA box, was measured. It looks healthy.
 The output power can go up to about 1 W, but I guess we
    Reply  Mon Jun 20 13:48:25 2011, Koji, Update, ABSL, I-P curve of LightWave M126-1064-700 
Hmm. Was the current within the operating range? (i.e. Is it a 700mW laser or a 1W one?)
You can obtain the nominal operating current from the old EPICS values (or some elog entries).
Note that NPROs are designed to be healthy only at around the nominal pumping power 
    Reply  Mon Jun 20 16:44:02 2011, steve, Update, ABSL, I-P curve of LightWave M126-1064-700 
 
 Put the serial numbers into the elog. So we can identify the laser and controller in the future.
The old days the NPRO ( inside the MOPA ) was running ~1.7A  500 mW
Entry  Wed Jun 22 15:24:10 2011, kiwamu, Update, ABSL, got a laser controller for LightWave DSC_3150.JPGDSC_3153.JPG
Peter King came over to the 40m with a laser controller and gave it to us.
We will test it out with the LightWave NPRO, which was used for MOPA.
    Reply  Thu Jun 23 22:59:45 2011, kiwamu, Update, ABSL, I-P curve of LWE IP_curve_small.png
 The I-P curve was measured again,
but this time in a lower current range of 1.0-1.9 [A].
The plot below is the latest I-P curve.
Entry  Fri Jun 24 00:13:24 2011, kiwamu, Update, ABSL, beam profile measurement of LWE beam_profile.png
The beam profile of the LWE (LightWave Electronics) NPRO was measured.
Mode matching telescopes will be designed and setup soon based on the result of the measurements.
 
    Reply  Fri Jun 24 07:49:23 2011, steve, Update, ABSL, I-P curve of LWE with serial numbers 


    
        
            Quote:
        
        
            

            The I-P curve was
Entry  Thu Jun 30 03:26:40 2011, kiwamu, Update, ABSL, status update 
Status update of the absolute length (ABSL) measurement:
 - To accommodate the ABSL stuff, the AS path was relocated on the AP table.
     (In this evening Jenne was able to lock MICH with AS55, so it's working fine.)
    Reply  Thu Jun 30 14:11:55 2011, kiwamu, Update, ABSL, a photo of ABSL setup on the AP table ABSLsetup.png
Here is a picture of the latest ABSL setup at the east part of the AP table.
    Reply  Thu Jun 30 21:00:20 2011, kiwamu, Update, ABSL, fine alignment done 
(Just a quick report)
The fine alignment of the ABSL laser injection was successfully done.
I was able to see the DRMI fringings at the AS camera. The ABSL beam is injected from the AS port, therefore what I saw on the camera was the reflection
    Reply  Tue Jul 5 16:09:54 2011, kiwamu, Update, ABSL, some photos for ABSL setup APtable.pngPSLtable.png
Here I show two photos of the latest ABSL (ABSolute Length measurement) setup. 
Entry  Tue Jul 5 17:38:46 2011, kiwamu, Update, ABSL, ABSL laser frequency-locked RFsetup.png
In this past weekend the ABSL laser was successfully frequency-locked to the
PSL laser with a frequency offset of about 100 MHz.
In the current setup a mixer-based frequency discriminator is used for
Entry  Mon Aug 1 04:08:24 2011, kiwamu, Update, ABSL, Arm length measurement : cavity kick technique ETMY_kick.png
I made some attempts to measure the current length of the arm cavities by
using the mass-kicking technique.
However unfortunately I am running out my energy to complete the measurement,
    Reply  Tue Aug 2 16:55:21 2011, rana, Update, ABSL, Arm length measurement : cavity kick technique L.png


    
        
            Quote:
        
        
            

           I made some attempts to measure the current length of the arm
Entry  Thu Aug 4 09:42:19 2011, Koji, Update, ABSL, ABSL Laser shutter closed 
The shutter of the ABSL laser is closed for the vent work.
Entry  Fri Mar 8 12:57:57 2013, Annalisa, Update, ABSL, BS installed on ITMY table 
 Sendhil and I installed the S polarized BS on the ITMY table to steer the NPRO beam through the AR wedge and align it to the POY beam. 
We took a shutter from the BSPRM table (which was not used) and a beam dump from the AS table (which was used by the auxiliary laser already removed
and installed on the ITMY).
    Reply  Fri Mar 8 13:42:35 2013, Jenne, Update, ABSL, BS installed on ITMY table 
Re:  POY beam reduction.
We are able to lock the Yarm with the beam / gain as it is.  I had thought we might need to increase the DC gain in the whitening board by
a factor of 2, but so far it's fine.
Entry  Mon Mar 18 12:02:12 2013, Annalisa, Configuration, ABSL, ABSL setup for g-factor measurement of PRC 
Motivations
The ABSL technique has been already used in the past to measure the absolute length of the interferometer's optical cavities
by means of  an auxiliary laser source, as described in LIGO-P1200048-v3 and in Alberto Stochino
Entry  Wed Mar 27 21:53:21 2013, Annalisa, Update, ABSL, Beat note of ATF auxiliary laser 
After measuring the beat note, the "Alberto" NPRO auxiliary laser has been moved from the PSL table to the POY table. Its beam profile is going
to be measured. It's going to be used as green laser on the END table, in place of the broken one.
The auxiliary laser borrowed form ATF lab (which will be used for the ABSL measurement) has been set on the PSL table to make a measurement of
    Reply  Thu Mar 28 23:00:30 2013, Annalisa, Update, ABSL, Beat note of ATF auxiliary laser found 
 
The beat note for the ATF lab laser has been found. 
The measurement has been carried out in the same way as described in elog 8368.
Entry  Fri Apr 26 10:50:07 2013, Annalisa, Update, ABSL, ATF laser on PSL 
The ATF NPRO auxiliary laser has been moved on the PSL table. All the optics for beat note measurement are in place and alignment has been done.
The setup for this measurement is the same as described in elog 8333.
    Reply  Thu May 16 08:32:05 2013, Steve, Update, 40m upgrading, ETMY op table disabled linguaa.jpg
 
All ETMY optical table electronics- lasers-pds turned off, disconnected in order to remove enclosure.
    Reply  Fri May 17 00:32:32 2013, Annalisa, Update, 40m upgrading, ETMY - progress IMG_0536.JPG
[Rana, Annalisa] 
 GREEN
 The alignment for the green has been improved, so that we have much more green power.
    Reply  Fri May 17 15:38:51 2013, Steve, Update, 40m upgrading, ETMY enclosure is on the way back 
 
 It  will arrive around 10 am Monday
morning. 
    Reply  Fri May 17 16:06:14 2013, rana, Update, 40m upgrading, ETMY op table disabled 
 
 TODO:

    We need to replace all of the floppy anodized Al dumps with clean razor blade dumps on stiff mounts. BOTH of the rejected ports of the
    Reply  Fri May 17 18:24:04 2013, Annalisa, Update, 40m upgrading, ETMY - progress 
I aligned the green beam into the Faraday. I needed an HWP to have the right polarization for the light entering the Faraday itself.
I tried to dump as much beams as possible with razor dumps, but eventually I had to use some "temporary solutions" for higher beams,
because I didn't find the right mounts for razor dumps.
    Reply  Thu May 23 00:16:32 2013, Annalisa, Update, 40m upgrading, ETMY - progress TransMonAndOplev.jpg
 [Annalisa, Koji] 
 GREEN 
I aligned back the beam (we lost part of the alignment after we put back the box and after the posts were installed).
    Reply  Fri May 24 02:12:50 2013, Annalisa, Update, 40m upgrading, ETMY - Mode Matching for green ModeMatchingGreen.jpgModeMatchingGreenZoom.jpgXYpath.jpg
 
 Mode Matching calculation for green beam - Yarm
After measuring the beam radius out from the Faraday for the green, I made the calculation to match the green beam mode with the IR mode inside
    Reply  Fri May 24 11:38:00 2013, Koji, Update, 40m upgrading, ETMY - Mode Matching for green 
I got confused. Is the mode calculation in the cavity correct? 
Are you sure the wavelength in the code is 532nm?
The first plot says "the waist radius at ITMY is 2.15mm". This number is already very close to 
    Reply  Fri May 24 12:50:25 2013, Annalisa, Update, 40m upgrading, ETMY - Mode Matching for green 


    
        
            Quote:
        
        
            

           I got confused. Is the mode calculation in the cavity correct? 
ELOG V3.1.3-